1.The new definition of metabolic dysfunction-associated steatotic liver disease: the role of ultrasound and elastography
Xinrui JIN ; Terry Cheuk-Fung YIP ; Grace Lai-Hung WONG ; Vincent Wai-Sun WONG ; Jimmy Che-To LAI
Ultrasonography 2025;44(3):189-201
In 2023, nonalcoholic fatty liver disease was renamed metabolic dysfunction-associated steatotic liver disease by the American and European liver associations. This new nomenclature recognizes metabolic dysfunction as the central driver of the disease, and the diagnostic criteria now require the presence of hepatic steatosis plus at least one of five cardiometabolic risk factors. B-mode ultrasonography remains the most common and practical method for detecting hepatic steatosis, although newer ultrasound techniques based on attenuation, backscatter, and speed of sound have gained traction as tools to diagnose and quantify hepatic steatosis. Additionally, ultrasound elastography is increasingly used in routine clinical practice to assess liver fibrosis, diagnose cirrhosis, and identify clinically significant portal hypertension.
2.The new definition of metabolic dysfunction-associated steatotic liver disease: the role of ultrasound and elastography
Xinrui JIN ; Terry Cheuk-Fung YIP ; Grace Lai-Hung WONG ; Vincent Wai-Sun WONG ; Jimmy Che-To LAI
Ultrasonography 2025;44(3):189-201
In 2023, nonalcoholic fatty liver disease was renamed metabolic dysfunction-associated steatotic liver disease by the American and European liver associations. This new nomenclature recognizes metabolic dysfunction as the central driver of the disease, and the diagnostic criteria now require the presence of hepatic steatosis plus at least one of five cardiometabolic risk factors. B-mode ultrasonography remains the most common and practical method for detecting hepatic steatosis, although newer ultrasound techniques based on attenuation, backscatter, and speed of sound have gained traction as tools to diagnose and quantify hepatic steatosis. Additionally, ultrasound elastography is increasingly used in routine clinical practice to assess liver fibrosis, diagnose cirrhosis, and identify clinically significant portal hypertension.
3.The new definition of metabolic dysfunction-associated steatotic liver disease: the role of ultrasound and elastography
Xinrui JIN ; Terry Cheuk-Fung YIP ; Grace Lai-Hung WONG ; Vincent Wai-Sun WONG ; Jimmy Che-To LAI
Ultrasonography 2025;44(3):189-201
In 2023, nonalcoholic fatty liver disease was renamed metabolic dysfunction-associated steatotic liver disease by the American and European liver associations. This new nomenclature recognizes metabolic dysfunction as the central driver of the disease, and the diagnostic criteria now require the presence of hepatic steatosis plus at least one of five cardiometabolic risk factors. B-mode ultrasonography remains the most common and practical method for detecting hepatic steatosis, although newer ultrasound techniques based on attenuation, backscatter, and speed of sound have gained traction as tools to diagnose and quantify hepatic steatosis. Additionally, ultrasound elastography is increasingly used in routine clinical practice to assess liver fibrosis, diagnose cirrhosis, and identify clinically significant portal hypertension.
4.The new definition of metabolic dysfunction-associated steatotic liver disease: the role of ultrasound and elastography
Xinrui JIN ; Terry Cheuk-Fung YIP ; Grace Lai-Hung WONG ; Vincent Wai-Sun WONG ; Jimmy Che-To LAI
Ultrasonography 2025;44(3):189-201
In 2023, nonalcoholic fatty liver disease was renamed metabolic dysfunction-associated steatotic liver disease by the American and European liver associations. This new nomenclature recognizes metabolic dysfunction as the central driver of the disease, and the diagnostic criteria now require the presence of hepatic steatosis plus at least one of five cardiometabolic risk factors. B-mode ultrasonography remains the most common and practical method for detecting hepatic steatosis, although newer ultrasound techniques based on attenuation, backscatter, and speed of sound have gained traction as tools to diagnose and quantify hepatic steatosis. Additionally, ultrasound elastography is increasingly used in routine clinical practice to assess liver fibrosis, diagnose cirrhosis, and identify clinically significant portal hypertension.
5.The new definition of metabolic dysfunction-associated steatotic liver disease: the role of ultrasound and elastography
Xinrui JIN ; Terry Cheuk-Fung YIP ; Grace Lai-Hung WONG ; Vincent Wai-Sun WONG ; Jimmy Che-To LAI
Ultrasonography 2025;44(3):189-201
In 2023, nonalcoholic fatty liver disease was renamed metabolic dysfunction-associated steatotic liver disease by the American and European liver associations. This new nomenclature recognizes metabolic dysfunction as the central driver of the disease, and the diagnostic criteria now require the presence of hepatic steatosis plus at least one of five cardiometabolic risk factors. B-mode ultrasonography remains the most common and practical method for detecting hepatic steatosis, although newer ultrasound techniques based on attenuation, backscatter, and speed of sound have gained traction as tools to diagnose and quantify hepatic steatosis. Additionally, ultrasound elastography is increasingly used in routine clinical practice to assess liver fibrosis, diagnose cirrhosis, and identify clinically significant portal hypertension.
6.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome
7.Expert consensus on the clinical strategies for orthodontic treatment with clear aligners.
Yan WANG ; Hu LONG ; Zhihe ZHAO ; Ding BAI ; Xianglong HAN ; Jun WANG ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxin BAI ; Weiran LI ; Min HU ; Yanheng ZHOU ; Hong AI ; Yuehua LIU ; Yang CAO ; Jun LIN ; Huang LI ; Jie GUO ; Wenli LAI
International Journal of Oral Science 2025;17(1):19-19
Clear aligner treatment is a novel technique in current orthodontic practice. Distinct from traditional fixed orthodontic appliances, clear aligners have different material features and biomechanical characteristics and treatment efficiencies, presenting new clinical challenges. Therefore, a comprehensive and systematic description of the key clinical aspects of clear aligner treatment is essential to enhance treatment efficacy and facilitate the advancement and wide adoption of this new technique. This expert consensus discusses case selection and grading of treatment difficulty, principle of clear aligner therapy, clinical procedures and potential complications, which are crucial to the clinical success of clear aligner treatment.
Humans
;
Consensus
;
Orthodontic Appliance Design
;
Orthodontic Appliances, Removable
;
Tooth Movement Techniques/methods*
;
Malocclusion/therapy*
;
Orthodontics, Corrective/instrumentation*
8.Laser Ablation Inductively Coupled Plasma Mass Spectrometry Analysis of Multilayer Thin Film Thickness of PbS Quantum Dot Photovoltaic Devices
Ding-Wen ZHANG ; Hui-Lai LI ; Fan LI ; Wei GUO ; Lan-Lan JIN ; Sheng-Hong HU
Chinese Journal of Analytical Chemistry 2024;52(10):1609-1618
Accurate determination of the thickness of multi-layered nanofilm materials is of great importance to advance the development of thin film deposition technology and ensure the quality assurance of photovoltaic materials.Laser ablation inductively coupled plasma mass spectrometry(LA-ICP-MS)has been successfully employed for depth profiling of thin film materials,such as metal coatings.However,the accuracy of interface discrimination and thin layer thickness measurement is limited by the mixing effects of elemental signals.In this work,a high-depth resolution method for measuring the thin film thickness of lead sulfide(PbS)colloidal quantum dot(CQD)photovoltaic devices by LA-ICP-MS was introduced.The influence of different laser parameters on the mixing effects of element signals during the ablation process was compared,and the results showed that the laser ablation behavior of multi-layered nanofilm materials were improved and the mixing of element signals were reduced by optimizing parameters such as laser energy density and spot diameter.Meanwhile,a self-developed aerosol rapid wash-out small volume tubular ablation cell was used to effectively improve the aerosol transport efficiency,and the wash-out time of aerosol was(1.60±0.6)s.Compared with commercial cylindrical ablation cells,the depth profile of multi-layer thin film samples was clearer.The depth profile of the interlayer interface showed a significant melting phenomenon during the ablation of the PbS CQD layer,leading to severe mixing of elemental signals at the PbS/ZnO layer interface.Under the conditions such as 2.5 J/cm2 laser energy,32 μm spot diameter,and 1 Hz repetition rate,the average ablation rates of Au,PbS and ZnO layers in PbS CQD photovoltaic devices were(60±2)nm/pulse,(69±5)nm/pulse,and(22±2)nm/pulse,with depth resolution of(26±2)nm,(213±11)nm,and(68±6)nm,respectively.The thickness of PbS CQD photovoltaic device films from the same batch was determined,and the test results exhibited good consistency with scanning electron microscope(SEM)measurement values,with a relative deviation of less than 6%.This method could accurately determine the thickness of nanoscale multilayer thin film samples,which was crucial for improving the performance of photovoltaic devices and controlling product quality.
9.Study on the Willingness of Users to Continue Using Knowledge Service of Hospital Library
Mengmeng WEI ; Hong HU ; Jin WEI ; Xin LAI
Journal of Medical Informatics 2024;45(2):92-97
Purpose/Significance To identify the influencing factors of users'willingness to use knowledge service of hospital library.Method/Process Based on the technology acceptance model,the theory of expectation confirmation model and perceived risk theory,the model and hypothesis of users'willingness to continue using knowledge service of hospital library are established.A questionnaire is de-signed and made,which is distributed to the staffs of Affiliated Tongji Hospital of Tongji Medical College,Huazhong University of Science and Technology by random sampling method.The structural equation model is used to validate and analyze the conceptual model.Result/Conclusion The findings show that expectation confirmation,perceived usefulness,perceived ease of use,and perceived interac-tivity all have positive effects on satisfaction.Of these,perceived usefulness is the most significant factor.Therefore,the key to ensure that users continue to use the library knowledge service is to enhance the usefulness of the service.
10.Signal mining and analysis for adverse events of avatrombopag based on FAERS
Rui XIONG ; Jin WANG ; Zhen YANG ; Yanmei LUO ; Hong ZHANG ; Yongtao TONG ; Xiaodan LAI
Journal of Army Medical University 2024;46(4):369-376
Objective To mine the adverse drug events(ADE)signal of avatrombopag,an effective drug for thrombocytopenia treatment,based on real world data in order to provide reference for its clinical safety application.Methods The OpenVigil2.1 pharmacovigilance platform was used to obtain the ADE report data of avatrombopag from May 2018 to March 2023 in the database of FDA adverse event reporting system(FAERS).The ADE signals were classified and described by the system organ class(SOC)and preferred term(PT)of the ADE terminology set in the Medical Dictionary for Regulatory Activities(MedDRA),and reporting odds ratio(ROR)and UK Medicines and Healthcare Products Regulatory Agency(MHRA)comprehensive standard were used to detect the positive ADE signals.Results A total of 1 879 ADE reports related to avatrombopag were obtained,24 SOCs were involved,and 28 positive ADE signals were detected at PT level.Among these signals,the strongest ones were renal vein thrombosis,portal vein thrombosis and graft versus host disease,while the reports accounting for the largest numbers were headache,fatigue and asthenia.There were 8 ADE signals discovered newly,that is,seasonal allergy,back disorder,musculoskeletal discomfort,flatulence,hypersomnia,rash macular,emotional disorder,and rhinorrhoea.Conclusion For clinical use of avatrombopag,clinicians should not only concern the risk of thrombosis,but also pay close attention to ADE signals such as seasonal allergy,back disorder,musculoskeletal discomfort,flatulence,hypersomnia,rash macular,emotional disorder,and rhinorrhoea that are not documented in the instructions.

Result Analysis
Print
Save
E-mail