1.Research of pulse diagnosis measurement using sensor array in Chinese Medicine
International Journal of Biomedical Engineering 2010;33(4):212-214,219
Objective To develop a new,three dimensional dynamic system for pulse detection.Methods According to bionics,a multi-information sensing mode with a soft surface is designed on the basis of traditional Chinese medical diagnosis in pulse.This mode imitates the touching sense of human finger and with the application of modern computer information processing technique,the pulse information is extracted in the way that is as close as possible to the traditional Chinese medicine pulse diagnosis.Results With the application of new sensor,pulse signal is detected and the effectiveness of the inovative three-dimension data transimition mode is validated since the pulse signal is three-dimensionally re-displayed on the computer screen.Conclusion The method introduced in this paper is proved feasible for detecting pulse information.Expected results are obtained and the method provides a new way and new feature reference for research and teaching in objectifying the diagnosis of traditional Chinese medical sciences.
2.Design of a flexible sensor array for pulse diagnosis in traditional Chinese medicine
Junqi ZHUO ; Lei WANG ; Hong SHA
International Journal of Biomedical Engineering 2015;38(1):15-18,后插4
Objective To acquire high spatial resolution two-dimension pulse pressure distribution for objectifying research of pulse diagnosis in traditional Chinese medicine.Methods A sensor array with flexible packing was designed and implemented.The array was formed on a circle substrate with 37 silicon piezoresistive pressure sensors,which were distributed as equilateral triangles with 1.95 mm pitch.The diameter of the substrate was 15 mm.By using flexible packing,the array had the hardness similar to that of human finger,which made this method closer to the traditional Chinese diagnosis.After differential amplifying,37-way pulse pressure signals were digitalized and reconstructed to obtain the pulse pressure distribution.Results With the application of the sensor array,the pulse pressure signals were measured and transformed into pulse pressure distribution.Conclusions The experimental result contains the relevant characteristics of traditional Chinese pulse diagnosis' description,providing a new way for objective study of traditional Chinese pulse diagnosis and further study.
3.Research progress of low energy laser irradiation in hyperlipidemia treatment
Haichen WANG ; Weichao LIU ; Hong WANG ; Hong SHA
International Journal of Biomedical Engineering 2017;40(1):53-57
Hyperlipidemia is one of the most important risk factors of human atherosclerosis and cardiaccerebral vascular disease.The number of hyperlipidemia in China increased year by year and showed a younger trend.The current treatments for hyperlipidemia include drug therapy,physical exercise,diet prevention,liposuction surgery and low-energy laser therapy,etc.Many researches showed that low intensity laser irradiation has a certain curative effect on hyperlipidemia.The aim of this paper is to provide a new idea and method for the future treatment of dyslipidemia by reviewing the anti-hyperlipidemia methods and mechanism of low energy laser irradiation treatment.
4.Simulation research on gastric emptying measurement experiment by electrical impedance tomography with three-layer electrodes
Lei WANG ; Shu ZHAO ; Juan DENG ; Yan WANG ; Hong SHA
International Journal of Biomedical Engineering 2016;39(2):107-110,后插4
Objective To verify the effectiveness of electrical impedance tomography (EIT) with multi-layer electrodes in gastric emptying measurement by simulation experiments using EIT with three-layer electrodes.Methods Firstly,EIT system with three-layer electrodes and gastric emptying measurement simulation equipment was designed and constructed to simulate gastric emptying process and obtain EIT reconstruction images.Secondly,the region where the electrical characteristic of gastric changes was selected as region of interest.Finally,the relative impedance change rate in region of interest for every image obtained from all three layers was consecutively recorded,then the gastric emptying curve was formed and gastric emptying time was calculated.Results There are obvious differences among the sharp of impedance change curves of interested region for three layers,and the gastric emptying time and process of each layer is also different from one another.It is suggested that the passing path and emptying manner of food in gastric emptying process reflected by EIT images varied from layer to layer.Therefore,the necessity and feasibility of using EIT with three-layer electrodes in gastric emptying measurement study is verified.Conclusions EIT with three-layer electrodes can provide more abundant information of gastric motility function associated with gastric emptying pathology and physiology state.It is likely to be a noninvasive,convenient and effective imaging method for the detection and evaluation research on gastric emptying and gastric motility.
5.Local impedance measurement method for monitoring and evaluation of injured muscle
Xu WU ; Lei WANG ; Yongjun WANG ; Hong SHA
International Journal of Biomedical Engineering 2014;37(1):26-30
Objective To establish a new methodology of evaluating rehabilitation status of local muscle injured by measuring the impedance and phase information.Methods An evaluation method was set up,which take symmetrical parts of injured muscle as control group during the measurement.Impedance and phase values of injured muscle were extracted with local impedance measurement method before and after rehabilitation to evaluate muscle recovery.Results Injured muscle tissue impedance values decreased significantly.In the process of rehabilitation of injured muscle,the impedance and phase values of the injured muscles were gradually approaching that of healthy muscle,and then achieved basically the same as reference values after rehabilitation.Conclusions Local impedance measurement method may provide a new,non-invasive and convenient evaluation method for the recovery of injured muscle tissue,and it has good prospects for clinical application.
6.Simulation and model experiment research of multichannel impedance gastric motility measurement
Lei WANG ; Yunjie TIAN ; Shu ZHAO ; Hong SHA
International Journal of Biomedical Engineering 2015;38(6):357-360,373,后插10
Objective To study the phase correlation of cutaneous multichannel impedance measurements and the contractions, peristalsis of stomach and the conduction properties in space.Methods A spiral gastric body model was rotated to simulate shrinkage and creep of the stomach.In order to verify the feasibility and validity of the multichannel impedance gastric dynamic measurement, experiments with emulation of multichannel impedance gastric motility measuring principle were conducted through three-dimensional simulation on the electrical characteristics of gastric body model in saline tank simulator.Results The emulation results showed that the change of epigastric current density and potential distribution is consistent with the course of moving from top to bottom when lateral edge of model (namely the intumescent location when the stomach is full) after detecting electrodes in sequence.Meanwhile, the measurement voltage wave forms clearly showed the contraction location of stomach after the model rotating for three cycles in a row, and the phase relationship between adjacent measurement channels was also measured.The sixty seconds data acquired by the experiment device proved that voltage wave form of three measurement channels corresponded to the phase relationship of movement status of the gastric body model.Conclusions Cutaneous multichannel wave forms prove a cyclical movement of stomach, and phase difference among the multichannel signals relating to speed of peristaltic wave, position of the measuring electrodes and channel spacing, etc.This study provides simulation and experimental basis for explanation of quantitative study of conduction properties in space and phase relationship between the results of surface multichannel impedance measurements and the contractions, peristalsis of stomach.
7.Investigation and Analysis on the Level of Vitamin A in Children in Beij ing City
Hong WANG ; Changzhao LAN ; Shaojie MA ; Yingwei BI ; Sha LUO
Journal of Modern Laboratory Medicine 2014;(6):139-141,144
Objective To understand the level of vitamin A (VA)in children in Beijing city.Methods 292 children aged from 0~14 years old visited the health clinic from November 2012 to March 2013 in Beijing city were surveyed by a question-naire,and medical history,physical examination,a blood sample was collected from each child,and serum VA was measured with reversed-phase high-performance liquid chromatography(HPLC).Results ①The mean serum VA concentration for the 292 children was (1.09 ± 0.29)μmol/L.②There were 5.8% (17/292)of children affected with subclinical VAD (SVAD),and 38.0% (107/292)had suspected SVAD (SSVAD).③Multivariate logistic regression analysis showed that parents were unware of health implications of VA,low VA intake and recurrent respiratory infection were associated with SVAD or SSVAD.Conclusion Low VA status remains a nutritional problem in children in Beij ing city.Multiple factors need to be considered together for them,such as parents were unware of health implications of VA,low VA intake and re-current respiratory infection.
8.Intelligent Rotational Behavior Monitor for Experiment Animal
Xin LIU ; You WU ; Yan WANG ; Hong SHA
Chinese Journal of Comparative Medicine 2009;19(3):64-68
Objective to develop a rotation monitoring device to monitor animal rotation during experiments.Methods Use serial port controls,USB and rotary encoder et al.modern computer cience,with the combination of traditionally experimental methods and the software designed in VC language.Results A mini animal rotation monitor was developed,which could continuously monitor animal rotation and intelligently display the rotaion.conclusion Statistic analysis of experimental data proofs the rationality and effectiveness of the apparatus.The rotational behavior monitor can play an importance role in research into the pathogenesis of Parkinson's Disease(PD)and screening the anti-PD drugs.
9.Evaluation of awareness of hypertension prevention and treatment knowledge before and after intensive training in physicians from hospitals at different levels in Xinjiang
Nanfang LI ; Jing HONG ; Junli HU ; Hongmei WANG ; Sha TAO
Chinese Journal of General Practitioners 2010;9(6):394-396
Objective To investigate awareness of hypertension prevention and treatment knowledge in physicians from hospitals at varied levels in Xinjiang. Methods In total, 150 voluntary physicians were selected randomly from hospitals at varied levels in Xinjiang for an anonymous close-book baseline survey on hypertension knowledge with questionnaire. Then, an intensive training on hypertension prevention and treatment based on Guidelines on Prevention and Treatment for Hypertension in China was offered for them.After training, another survey was conducted among them with the same questionnaire to examine improvement in their awareness of hypertension prevention and treatment knowledge and evaluate effectiveness of the training. Results At baseline, 89. 3 percent (134/150) of physicians could correctly know diagnostic criteria for hypertension, 78. 3 percent ( 18/23 ) of them from primary-care hospitals, and 52. 0 percent (78/150) could correctly know level of blood pressure under control, only 34. 8 percent (8/23) of them from primary-care hospitals. Only 67 (44. 7% ) physicians surveyed could know criteria for non-antihypertensive drug treatment, 27 of then from secondary-care hospitals and nine from primary-care ones, significant less in that among those from tertiary-care ones ( 88. 6%, 31/35 ) ( P < 0. 05 ). After training, their awareness of hypertension prevention and treatment knowledge improved significantly ( P <0. 01). Conclusions Awareness of hypertension prevention and treatment knowledge differed considerably in physicians from hospitals at varied levels, poorer in those from primary-care hospitals, and more importance should be attached to them, especially to those from primary-care hospitals.
10.Advanced Development of Multi-information Acquisition System on Pulse Tracings of Traditional Chinese Medicine
Hong SHA ; Shu ZHAO ; Yan WANG ; Chaoshi REN ;
China Journal of Traditional Chinese Medicine and Pharmacy 2005;0(01):-
According to the multi-information characteristic of pulse tracings in traditional Chinese medicine(TCM) and the dynamic analysis and identification technique of sonogram,the multi-information detection system of pulse examination was constructed by combining B-type ultrasound and flexible transducer.It made information integration of supersonic dynamic image,pressure pulse wave,photoelectric capacity pulse wave and electrocardiogram,and though the aggregate analysis of computer information processing technique,established the pulse tracings signature analysis method,formed optimized solving scheme for describing the four attributes("location,velocity,shape and potential") of pulse examination in TCM.From the multi-information data of healthy people's pulse tracings collected by this system,it can be infer that the new method of objectification of pulse examination referred in this article is feasible,and have gain the prospective effect.It provides a new method and characteristic data for the clinical study of objectification of pulse examination and teaching of TCM.