1.Secondary Hemochromatosis in a Patient with Aplastic Anemia: An autopsy case report.
Seung Mo HONG ; Ghil Suk YOON ; Young Min KIM ; Hojung LEE ; Gyeong Hoon KANG ; On Ja KIM
Korean Journal of Pathology 1998;32(8):608-612
We report an autopsy case of secondary hemochromatosis associated with multiple frequent blood transfusion for the treatment of aplastic anemia. A 23-year-old man had been diagnosed as having aplastic anemia at the age of 13. He received a whole blood transfusion, about 1280 ml, every month during the past 10 years. Recently he developed diabetes mellitus and a congestive heart failure. The autopsy revealed that multiple organs were affected by secondary hemochromatosis, including the liver, heart, pancreas, spleen, bone marrow, stomach, thyroid gland, adrenal glands, and testes. The lungs and liver showed gross and microscopic findings consistent with a congestive heart failure in addition to hemochromatosis. The details are presented. This is a case of rare secondary hemochromatosis occurring in a young man and presenting the classic histopathologic changes indistinguishable from those of primary hemochromatosis.
Adrenal Glands
;
Anemia
;
Anemia, Aplastic*
;
Autopsy*
;
Blood Transfusion
;
Bone Marrow
;
Diabetes Mellitus
;
Heart
;
Heart Failure
;
Hemochromatosis*
;
Humans
;
Liver
;
Lung
;
Pancreas
;
Spleen
;
Stomach
;
Testis
;
Thyroid Gland
;
Young Adult
2.Health Insurance Claim Review Using Information Technologies.
Young Taek PARK ; Jeong Sik YOON ; Stuart M SPEEDIE ; Hojung YOON ; Jiseon LEE
Healthcare Informatics Research 2012;18(3):215-224
OBJECTIVES: The objective of this paper is to describe the Health Insurance Review and Assessment Service (HIRA)'s payment request (PARE) system that plays the role of the gateway for all health insurance claims submitted to HIRA, and the claim review support (CRS) system that supports the work of claim review experts in South Korea. METHODS: This study describes the two systems' information technology (IT) infrastructures, their roles, and quantitative analysis of their work performance. It also reports the impact of these systems on claims processing by analyzing the health insurance claim data submitted to HIRA from April 1 to June 30, 2011. RESULTS: The PARE system returned to healthcare providers 2.7% of all inpatient claims (97,930) and 0.1% of all outpatient claims (317,007) as un-reviewable claims. The return rate was the highest for the hospital group as 0.49% and the lowest rate was found in clinic group. The CRS system's detection rate of the claims with multiple errors in inpatient and outpatient areas was 23.1% and 2.9%, respectively. The highest rate of error detection occurred at guideline check-up stages in both inpatient and outpatient groups. CONCLUSIONS: The study found that HIRA's two IT systems had a critical role in reducing heavy administrative workloads through automatic data processing. Although the return rate of the problematic claims to providers and the error detection rate by two systems was low, the actual count of the returned claims was large. The role of IT will become increasingly important in reducing the workload of health insurance claims review.
Automatic Data Processing
;
Health Personnel
;
Humans
;
Inpatients
;
Insurance Claim Review
;
Insurance, Health
;
Medical Informatics
;
Outpatients
3.Transcranial Doppler ultrasound analysis of resistive index in rostral and caudal cerebral arteries in dogs.
Minho SEO ; Hojung CHOI ; Kichang LEE ; Mincheol CHOI ; Junghee YOON
Journal of Veterinary Science 2005;6(1):61-66
Transcranial Doppler (TCD) was carried out to determine the resistive index (RI) values of normal canine cerebral arteries and its reproducibility and to evaluate the change of cerebral vascular resistance following diuretics administration. RI values of rostral cerebral artery (RCA) were compared between fontanelle window and temporal window. Normal ranges and reproducibility of the RI values were examined in the rostal cerebral artery (RCA) and caudal cerebral artery (CCA). And after administration of diuretics, TCD-derived RI values were measured at RCA and CCA. Cerebral vascular RI values of RCA and CCA were 0.55 +/- 0.05 and 0.55 +/- 0.03 in the normal dogs, respectively. There was no significant difference of RI between male and female; between fontanelle window and temporal window. Reproducibility of RI measurements between intraobserver and interobserver were relatively high. The RI of RCA and CCA were significantly increased 15 minutes after mannitol administration (p<0.01) and returned to baseline values by 30 minutes, but it did not significantly change after furosemide and saline administration. The results suggest that TCD is a useful test which can obtain reproducible results from any window and has the advantage of detecting subtle changes in cerebral vascular resistance.
Animals
;
Cerebral Arteries/drug effects/*ultrasonography
;
Diuretics/pharmacology
;
Dogs/*physiology
;
Feasibility Studies
;
Furosemide/pharmacology
;
Mannitol/pharmacology
;
Reference Values
;
Reproducibility of Results
;
Ultrasonography, Doppler/*veterinary
;
Vascular Resistance/drug effects/*physiology
4.Classification of radiographic lung pattern based on texture analysis and machine learning
Youngmin YOON ; Taesung HWANG ; Hojung CHOI ; Heechun LEE
Journal of Veterinary Science 2019;20(4):e44-
This study evaluated the feasibility of using texture analysis and machine learning to distinguish radiographic lung patterns. A total of 1200 regions of interest (ROIs) including four specific lung patterns (normal, alveolar, bronchial, and unstructured interstitial) were obtained from 512 thoracic radiographs of 252 dogs and 65 cats. Forty-four texture parameters based on eight methods of texture analysis (first-order statistics, spatial gray-level-dependence matrices, gray-level-difference statistics, gray-level run length image statistics, neighborhood gray-tone difference matrices, fractal dimension texture analysis, Fourier power spectrum, and Law's texture energy measures) were used to extract textural features from the ROIs. The texture parameters of each lung pattern were compared and used for training and testing of artificial neural networks. Classification performance was evaluated by calculating accuracy and the area under the receiver operating characteristic curve (AUC). Forty texture parameters showed significant differences between the lung patterns. The accuracy of lung pattern classification was 99.1% in the training dataset and 91.9% in the testing dataset. The AUCs were above 0.98 in the training set and above 0.92 in the testing dataset. Texture analysis and machine learning algorithms may potentially facilitate the evaluation of medical images.
Animals
;
Area Under Curve
;
Cats
;
Classification
;
Dataset
;
Dogs
;
Fourier Analysis
;
Fractals
;
Lung
;
Machine Learning
;
Neural Networks (Computer)
;
Pattern Recognition, Visual
;
Radiography, Thoracic
;
Residence Characteristics
;
ROC Curve
5.Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs.
Jinhwa CHANG ; Sujin KIM ; Joohyun JUNG ; Heechun LEE ; Hojung CHOI ; Dongwoo CHANG ; Youngwon LEE ; Junghee YOON ; Mincheol CHOI
Journal of Veterinary Science 2011;12(4):393-399
The objective of our study was to determine individual and global glomerular filtration rates (GFRs) using dynamic renal computed tomography (CT) in Beagle dogs. Twenty-four healthy Beagle dogs were included in the experiment. Anesthesia was induced in all dogs by using propofol and isoflurane prior to CT examination. A single slice of the kidney was sequentially scanned after a bolus intravenous injection of contrast material (iohexol, 1 mL/kg, 300 mgI/mL). Time attenuation curves were created and contrast clearance per unit volume was calculated using a Patlak plot analysis. The CT-GFR was then determined based on the conversion of contrast clearance per unit volume to contrast clearance per body weight. At the renal hilum, CT-GFR values per unit renal volume (mL/min/mL) of the right and left kidneys were 0.69 +/- 0.04 and 0.57 +/- 0.05, respectively. No significant differences were found between the weight-adjusted CT-GFRs in either kidney at the same renal hilum (p = 0.747). The average global GFR was 4.21 +/- 0.25 mL/min/kg and the whole kidney GFR was 33.43 +/- 9.20 mL/min. CT-GFR techniques could be a practical way to separately measure GFR in each kidney for clinical and research purposes.
Animals
;
Dogs/*physiology
;
Female
;
Glomerular Filtration Rate/*physiology
;
Male
;
Reference Values
;
Tomography, X-Ray Computed/methods/*veterinary
6.Quantification of mitral regurgitation using proximal isovelocity surface area method in dogs.
Hojung CHOI ; Kichang LEE ; Heechun LEE ; Youngwon LEE ; Dongwoo CHANG ; Kidong EOM ; Hwayoung YOUN ; Mincheol CHOI ; Junghee YOON
Journal of Veterinary Science 2004;5(2):163-171
The present study was performed to determine the accuracy and reproducibility of calculating the mitral regurgitant orifice area with the proximal isovelocity surface area (PISA) method in dogs with experimental mitral regurgitation and in canine patients with chronic mitral insufficiency and to evaluate the effect of general anesthesia on mitral regurgitation. Eight adult, Beagle dogs for experimental mitral regurgitation and 11 small breed dogs with spontaneous mitral regurgitation were used. In 8 Beagle dogs, mild mitral regurgitation was created by disrupting mitral chordae or leaflets. Effective regurgitant orifice (ERO) area was measured by the PISA method and compared with the measurements simultaneously obtained by quantitative Doppler echocardiography 4 weeks after creation of mitral regurgitation. The same procedure was performed in 11 patients with isolated mitral regurgitation and in 8 Beagle dogs under two different protocols of general anesthesia. ERO and regurgitant stroke volume (RSV) by the PISA method correlated well with values by the quantitative Doppler technique with a small error in experimental dogs (r = 0.914 and r = 0.839) and 11 patients (r = 0.990 and r = 0.996). The isoflurane anesthetic echocardiography demonstrated a significant decrease of RSV, and there was no significant change in fractional shortening (FS), ERO area, LV end-diastolic and LV end-systolic volume. ERO area showed increasing tendency after ketamine-xylazine administration, but not statistically significant. RSV, LV end-systolic and LV end-diastolic volume increased significantly (p < 0.01), whereas FS significantly decreased (p < 0.01). The PISA method is accurate and reproducible in experimental mitral regurgitation model and in a clinical setting. ERO area is considered and preferred as a hemodynamic-nondependent factor than other traditional measurements.
Anesthesia, Rectal
;
Animals
;
Body Surface Potential Mapping/*veterinary
;
Chordae Tendineae/physiopathology/surgery
;
Dog Diseases/diagnosis/*physiopathology
;
Dogs
;
Echocardiography, Doppler/veterinary
;
Electrocardiography/veterinary
;
Mitral Valve/*physiopathology
;
Mitral Valve Insufficiency/diagnosis/physiopathology/*veterinary