1.Effect of steroid and gonadotropin on the cumulus expansion and oocyte maturation in vitro.
Hoe Soon YU ; Jae Myeoung KIM ; Chung Soon BAIK ; Byung Hee SUH ; Jae LEE
Korean Journal of Obstetrics and Gynecology 1993;36(5):640-647
No abstract available.
Gonadotropins*
;
Oocytes*
2.The effect of denture cleansers on the bond strength and the surface hardness of reline resin to denture base resin.
Kyea Soon KIM ; Hoe Yeol JEONG ; Yu Lee KIM ; Hye Won CHO
The Journal of Korean Academy of Prosthodontics 2003;41(4):493-502
STATEMENT OF PROBLEM: Removable partial denture and complete denture often require denture base relines to improve the fittness against tissue-bearing mucosa because of the gradual change in edentulous ridge contour and resorption of underlyng bony structure. Self-curing hard reline resins offers the immediate and relatively inexpensive means to be recondition the surface of denture base directly. However weak bond between denture base resin and reline material can harbor bacteria, promote staining, or result in complete separation of the two materials. PURPOSE: The purpose of this study was to evaluate the effect of denture cleansers on bond strength and surface hardness of reline resin to denture base resin Denture base resin beams(60.0x15.0x3.0 mm) were made with Lucitone 199. MATERIAL AND METHODS: 10mm section was removed from the center of each specimen. The samples were replaced in the molds and the space of 10mm sections were packed with Tokuso Rebase reline material. The specimens were immersed in denture cleansers(Polident, Cleadent) and were evaluated after 1week, 2weeks, and 4weeks. The bond strength and surface hardness of self-curing hard reline materials to heat-curing denture base resin were measured using an UTM(universal testing machine). RESULTS AND CONCLUSION: 1) There was no significant difference of usage, kind, and denture cleaner by application time on the bonding strength of self-curing hard reline resin to denture base resin. 2) There was no significant difference of usage, kind, and denture cleaner by application time on the surface hardness, but the surface hardness showed decreasing tendency, as the time of immersion was extended 3) The failure modes of the specimens was initially adhesive failure and finally cohesive failure of self-curing hard reline resin.
3.Clinical and Hemodynamic Observation on Constrictive Pericarditis.
Hong Soon LEE ; Jong Hwa KIM ; Woo Hyung LEE ; Yeong Cheol KIM ; Soo Woong YOO ; Hak Choong LEE ; Hoe Sung YU
Korean Circulation Journal 1983;13(1):97-105
A clinical study was done on 16 cases of constrictive pericarditis admitted to National Medical Center, from january, 1970 to October, 1982, were reviewed, conclusion as follows: 1) The patients with constrictive pericarditis generally revealed clinical features of right heart failure but low incidence of its characteristic features. 2) Hemodynamic and echocardiographic examinations were much helpful in confirmation of clinical diagnosis. 3) pericardiectomy was highly succesful in achievement of clinical improvement.
Diagnosis
;
Echocardiography
;
Heart Failure
;
Hemodynamics*
;
Humans
;
Incidence
;
Pericardiectomy
;
Pericarditis, Constrictive*