1.The Effect of Deep Breathing Exercise and Incentive Spirometry to Prevent Postoperative Pulmonary Complications after Abdominal Surgery in Geriatric Patients.
Chul LIM ; Hun CHO ; Sung Ho CHANG
Korean Journal of Anesthesiology 1997;33(6):1185-1191
BACKGROUND: The purpose of this clinical study was to evaluate the Incentive Spirometry (IS) and Deep Breathing Exercises (DBE) to prevent postoperative pulmonary complications after abdominal surgery in patients over 60 years of age. METHODS: We prospectively randomized 90 patients into 1 of 3 groups: the control group (30 patients) received no respiratory treatment, the IS group (30 patients) was treated with incentive spirometry 4 times daily and DBE group (30 patients) carried out deep breathing exercises under supervision for 15 min 4 times daily. ABGA was taken at ward, PR (preop.room), RR (recovery room), POD1 day and POD2 day. Roentgenographic changes observed at 24 h. and 48 h. after surgery. Pulmonary complications were defined as the development of 3 or more of 6 new findings: cough, sputum, dyspnea, chest discomfort, temperature greater than 38oC, pulse rate more than 100 beats/min. RESULTS: PaO2 in the DBE group and IS group at PR were significantly increased than the values at ward, and the values of the PaO2 in the DBE group at RR and POD1 day, and those of IS group at PR and POD2 day were significant higher than those of the control group (p<0.05). The frequency of development of pulmonary complications (43.3% in the control group, 20% in the DBE group, 20% in the IS group) and roentgenographic changes were comparable in the 3 groups (26.7%, 16.7%, 20% respectively). The DBE group showed the different incidence of postoperative pulmonary complications between upper and lower abdominal surgery (upper: lower= 35.7: 6.3%). CONCLUSIONS: We concluded that DBE and IS were effective in preventing postoperative pulmonary complications after abdominal surgery and lower abdominal surgery causes lesser postoperative pulmonary complications than upper abdominal surgery.
Breathing Exercises
;
Cough
;
Dyspnea
;
Heart Rate
;
Humans
;
Incidence
;
Motivation*
;
Organization and Administration
;
Prospective Studies
;
Respiration*
;
Spirometry*
;
Sputum
;
Thorax
2.A STUDY ON ACCUARACY AND DIMENSIONAL STABILITY ACCORDING TO IMPRESSION METHODS.
Jae Young LEE ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 1999;37(5):567-580
Accurate reproduction of intraoral tissue is essential in the fabrication of fixed prosthesis. This selection of impression material and method is very important. In this study, vinyl polysiloxane type impression material Panasil was used. Three impression methods ; one-step technique, individual tray technique, and individual tooth tray technique using the vinyl polysiloxane type bite registration material Futar Occlusion, were used to take horizontal and vertical impression. Improved stone models were fabricated. The amount of occlusal surface discrepaneies, interabutment distance discrepancies, amount of marginal defect were evaluated with the X-PLAN360d and photoscanning. The results were as follows. 1. There was no significant difference in occlusal surface according to the directions and techniques of impression taking. 2. There was no significant difference in interabutment distance discrepancies according to the directions and techniques of impression taking 3. There was no significant difference in marginal discrepancies according to the direction of impression taking but there was significant difference between one-step technique and individual tray technique, individual tooth tray technique (P<0.05). Taken together, these results suggest that individual tray technique and individual tooth tray technique are more accurate for impression taking than one-step technique.
Jaw Relation Record
;
Prostheses and Implants
;
Reproduction
;
Siloxanes
;
Tooth
3.A STUDY ON THE EFFECT OF UV LIGHT ABSORBER ON THE COLOR CHANGE OF MAXILLOFACIAL SILICONE.
Yun Seok SONG ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 1999;37(3):343-357
The color change of maxillofacial silicone has been attributed to certain environmental factors such as exposure to the UV component of natural sunlight, wetting and drying of the elastomer, and surface abrasion resulting from the application and removal of cosmetics. The purpose of this study was to evaluate the color change of maxillofacial silicone (Silastic MDX4-4210) according to type of pigment (cadmium yellow, titanium white, cosmetic red), and UV absorber application method after 200, 400, and 600 hours of 350nm UV light irradiation. The results were as follows. 1. According to type of pigments, after 200 hours cosmetic red showed significantly larger color change than cadmium yellow and titanium white, and after 400 and 600 hours color change significantly decreased in the order of cosmetic red, cadmium yellow, and titanium white (p<0.05). 2. In the cadmium yellow group, after 200 hours, the non-treatment group showed significantly larger color change, but after 400 and 600hours, color change significantly decreased in the order of non-treatment, surface application and mixed group (p<0.05). 3. In the titanium white group, there was no significant color change difference between the three groups after 200 and 400 hours, but after 600 hours, the mixed group showed significantly smaller color change than the non-treatment and surface application groups (p<0.05). 4. In the cosmetic red group, there was significant decrease in color change in the order non-treatment, surface application and mixed group (p<0.05). From the results above, the effect of UV light absorber differed according to the type of pigment, but mixing UV light aborber with maxillofacial silicone is thought to give superior resistance against UV light irradiation in the long run.
Cadmium
;
Elastomers
;
Silicones*
;
Sunlight
;
Titanium
;
Ultraviolet Rays*
4.A Study On The Color Stability Of Porcelain For Porcelain Fused To Metal Crown.
So Young RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(1):73-84
Dental porcelain should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental porcelain has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 types of porcelain (Vintage, VMK 95, CERAMCO II). The porcelain were divided into groups by 2 types of treatment (Glazing or non-glazing and thermocycling or non-thermocycling). The porcelain wee dyed with methylene blue and distilled water, and then the color stability was evaluated with a spectrophotometer. The results were as follow ; 1. The color change of porcelain increased in the order of VMK 95, Vintage, CERAMCO II. But there was no significant difference. 2. The color change decreased in the glazing group compared to the non-glazing group(p<0.05). 3. The color change increased after thermocycling But there was no significant difference. 4. The color change according to dye method was significantly larger with methylene blue copared to distilled water(P<0.05).
Crowns*
;
Dental Porcelain*
;
Dental Research
;
Dentistry
;
Esthetics
;
Methylene Blue
;
Tooth
;
Water
5.Comparison of retentive force of repair resin by various surface treatment methods in the repair of fractured porcelain fused to metal crown.
Heon Song LIM ; Seong Joo HEO ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 1992;30(1):73-83
No abstract available.
Crowns*
;
Dental Porcelain*
6.Two Cases of Patau Syndrome.
Eun Hee CHO ; Byung Ho LIM ; Ki Bok KIM
Journal of the Korean Pediatric Society 1986;29(2):107-
No abstract available.
7.A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY.
Duck Woo RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(2):242-254
Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth' s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin, Futar' occlusion, Blu-mousse) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by X-PLAN360d to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference. 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less mar ginal discrepancy than groups with 0.5mm-marginal-vent-space(p<0.05). In summary, these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.
Humans
;
Jaw Relation Record
;
Prostheses and Implants
;
Tooth*
8.A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY.
Duck Woo RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(2):242-254
Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth' s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin, Futar' occlusion, Blu-mousse) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by X-PLAN360d to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference. 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less mar ginal discrepancy than groups with 0.5mm-marginal-vent-space(p<0.05). In summary, these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.
Humans
;
Jaw Relation Record
;
Prostheses and Implants
;
Tooth*
9.A STUDY ON THE HEAT GENERATION OF BONE DRILLING BURS ACCORDING TO IRRIGATION DURING IMPLANTATION OF DENTAL IMPLANT.
Eun Soo MOON ; Heun Song LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 1999;37(4):433-453
There are a lot of elements affecting the success of implant prosthesis. The quality of surgical procedure is considered as one of the key factors. To avoid the excess heat generation is an important element of successful osseointegration and it can be achieved by using a gentle surgical technique with a sharp instrument in bone drilling. This study was performed to measure and analyze comparatively the heat transmitted to surrounding bone at a distance of 0.5mm from the periphery of the drill hole in each drilling stage. The results were as follows. In standard system, the temperature of surrounding bone tissue ranged from 29.2degrees Cto 48.3degrees C with irrigation and from 34.6degrees C to 84.3degrees C without irrigation. And in wide system, the temperature of surrounding bone tissue ranged from 29.5degrees C to 52.5degrees C with irrigation and from 34.8degrees C to 87.8degrees C without irrigation. And the temperature ranges exceeded the threshold without irrigation, while showing less than the threshold by the cooling effect of irrigation. In comparing standard system with wide system, although there was no significant difference, 4.3mm pilot and 4.3mm twist drill of wide system showed high value and wide system showed slightly high elevation of temperature in all depth in fixture installation In the finite element analysis, the calculated value by the Fourier's cooling law were applied to the bone drilling surface. And through analysis using different irrigation temperatures at 28degrees C, 15degrees C and 5degrees C, and according to the time. The result was that the cooling water at least below 15degrees C was required to maintain the temperature of surrounding bone less than threshold in bone drilling, the cooling water below 5degrees C was required to gain more sufficient cooling effect, and cooling over 5 seconds was needed after bone drilling for sufficient effect.
Bone and Bones
;
Dental Implants*
;
Finite Element Analysis
;
Hot Temperature*
;
Jurisprudence
;
Osseointegration
;
Prostheses and Implants
;
Water
10.A Study On The Tensile Strength Between Metal Denture Base And Relining Materials.
Joon Seok LEE ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(1):1-11
Relining and rebasing are essential for long-term success and oral health in removable prosthodontics. Major features of failures between metal base and relining resins are adhesive failure due to lack of chemical bonding. The purpose of this study was to find a better metal primer and metal surface treatment method that enhance the bonding strength with relining resin materials. The surfaces of ticonium alloys were treated with 25micrometer sandblasting (Group A), stone wheel (Group B), stone wheel and EZ oxisor (Group C), 75micrometer sandblasting (Group D) and EZ oxisor application after 75micrometer sandblasting (Group E). They were subdivided into no primer application (Group I), MR bond application (Group II) and Metafast bonding liner (Group III). Then specimens were completed though being bonded with relining resins. The specimens were stored in 38degrees C water for 48 hours and tensile strength was measured using the universal testing machine. The results were as follows, 1. Primer application groups showed higher bond strength than no primer application group(p<0.05). 2. In comparison with primer application groups, MR bond group showed higher bond strength than Meta fast bonding liner application group(p<0.05). 3. In comparison with surface treatment methods. Bond strengths of group A and B were significantly different with group C, D, and E, and group C were significantly different with group D, and E in no primer application group(p<0.05). In primer application groups, group A, B, C were significantly different with group D and E(p<0.05). According to results of this study, Metal primer application and metal surface roughening were considered to be advantageous for relining of metal base dentures.
Adhesives
;
Alloys
;
Denture Bases*
;
Dentures*
;
Oral Health
;
Prosthodontics
;
Tensile Strength*
;
Water