1.A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet Obstruction.
Naminatsu TAKAHARA ; Hiroyuki ISAYAMA ; Yousuke NAKAI ; Shuntaro YOSHIDA ; Tomotaka SAITO ; Suguru MIZUNO ; Hiroshi YAGIOKA ; Hirofumi KOGURE ; Osamu TOGAWA ; Saburo MATSUBARA ; Yukiko ITO ; Natsuyo YAMAMOTO ; Minoru TADA ; Kazuhiko KOIKE
Gut and Liver 2017;11(4):481-488
BACKGROUND/AIMS: Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. METHODS: We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. RESULTS: The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. CONCLUSIONS: A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.
Gastric Outlet Obstruction*
;
Humans
;
Palliative Care
;
Pancreatitis
;
Retrospective Studies
;
Self Expandable Metallic Stents
;
Stents*
;
Tertiary Care Centers
2.Antireflux Metal Stent as a First-Line Metal Stent for Distal Malignant Biliary Obstruction: A Pilot Study.
Tsuyoshi HAMADA ; Hiroyuki ISAYAMA ; Yousuke NAKAI ; Osamu TOGAWA ; Naminatsu TAKAHARA ; Rie UCHINO ; Suguru MIZUNO ; Dai MOHRI ; Hiroshi YAGIOKA ; Hirofumi KOGURE ; Saburo MATSUBARA ; Natsuyo YAMAMOTO ; Yukiko ITO ; Minoru TADA ; Kazuhiko KOIKE
Gut and Liver 2017;11(1):142-148
BACKGROUND/AIMS: In distal malignant biliary obstruction, an antireflux metal stent (ARMS) with a funnel-shaped valve is effective as a reintervention for metal stent occlusion caused by reflux. This study sought to evaluate the feasibility of this ARMS as a first-line metal stent. METHODS: Patients with nonresectable distal malignant biliary obstruction were identified between April and December 2014 at three Japanese tertiary centers. We retrospectively evaluated recurrent biliary obstruction and adverse events after ARMS placement. RESULTS: In total, 20 consecutive patients were included. The most common cause of biliary obstruction was pancreatic cancer (75%). Overall, recurrent biliary obstruction was observed in seven patients (35%), with a median time to recurrent biliary obstruction of 246 days (range, 11 to 246 days). Stent occlusion occurred in five patients (25%), the causes of which were sludge and food impaction in three and two patients, respectively. Stent migration occurred in two patients (10%). The rate of adverse events associated with ARMS was 25%: pancreatitis occurred in three patients, cholecystitis in one and liver abscess in one. No patients experienced non-occlusion cholangitis. CONCLUSIONS: The ARMS as a first-line biliary drainage procedure was feasible. Because the ARMS did not fully prevent stent dysfunction due to reflux, further investigation is warranted.
Arm
;
Asian Continental Ancestry Group
;
Cholangiopancreatography, Endoscopic Retrograde
;
Cholangitis
;
Cholecystitis
;
Drainage
;
Humans
;
Liver Abscess
;
Pancreatic Neoplasms
;
Pancreatitis
;
Pilot Projects*
;
Retrospective Studies
;
Sewage
;
Stents*