1.Cementless Total Hip Arthroplasty for Patients with Crowe Type III or IV Developmental Dysplasia of the Hip: Two-Stage Total Hip Arthroplasty Following Skeletal Traction after Soft Tissue Release for Irreducible Hips.
Pil Whan YOON ; Jung Il KIM ; Dong Ok KIM ; Cheol Hwan YU ; Jeong Joon YOO ; Hee Joong KIM ; Kang Sup YOON
Clinics in Orthopedic Surgery 2013;5(3):167-173
BACKGROUND: Total hip arthroplasty (THA) for severe developmental dysplasia of the hip (DDH) is a technically demanding procedure for arthroplasty surgeons, and it is often difficult to reduce the hip joint without soft tissue release due to severe flexion contracture. We performed two-stage THAs in irreducible hips with expected lengthening of the affected limb after THA of over 2.5 cm or with flexion contractures of greater than 30 degrees in order to place the acetabular cup in the true acetabulum and to prevent neurologic deficits associated with acute elongation of the limb. The purpose of this study is to evaluate the outcomes of cementless THA in patients with severe DDH with a special focus on the results of two-stage THA. METHODS: Retrospective clinical and radiological evaluations were done on 17 patients with Crowe type III or IV developmental DDH treated by THA. There were 14 women and 3 men with a mean age of 52.3 years. Follow-ups averaged 52 months. Six cases were treated with two-stage THA followed by surgical hip liberalization and skeletal traction for 2 weeks. RESULTS: The mean Harris hip score improved from 40.9 to 89.1, and mean leg length discrepancy (LLD) in 13 unilateral cases was reduced from 2.95 to 0.8 cm. In the patients who underwent two-stage surgery, no nerve palsy was observed, and the single one-stage patient with incomplete peroneal nerve palsy recovered fully 4 weeks postoperatively. CONCLUSIONS: The short-term clinical and radiographic outcomes of primary cementless THA for patients with Crowe type III or IV DDH were encouraging. Two-stage THA followed by skeletal traction after soft tissue release could provide alternative solutions to the minimization of limb shortenings or LLD without neurologic deficits in highly selected patients.
Adult
;
Aged
;
Arthroplasty, Replacement, Hip/*instrumentation/*methods
;
Female
;
Femur/radiography/surgery
;
Hip/radiography/surgery
;
Hip Dislocation, Congenital/pathology/radiography/*surgery
;
Hip Joint/pathology/radiography/surgery
;
Hip Prosthesis
;
Humans
;
Ilium/radiography/surgery
;
Male
;
Middle Aged
;
Orthopedic Fixation Devices
;
Retrospective Studies
;
Traction
2.Cotyloplasty in Cementless Total Hip Arthroplasty for an Insufficient Acetabulum.
Yong Lae KIM ; Kwang Woo NAM ; Jeong Joon YOO ; Young Min KIM ; Hee Joong KIM
Clinics in Orthopedic Surgery 2010;2(3):148-153
BACKGROUND: Cotyloplasty is a technique that involves making a perforation of the medial wall of a shallow acetabulum and then inserting an acetabular cup with the medial aspect of its dome beyond the Kohler line. The purpose of this study was to evaluate the results of cementless total hip arthroplasty (THA) using cotyloplasty with focusing on the amount of medial cup protrusion. METHODS: Sixteen hips with insufficient acetabulum in sixteen patients were treated by cementless THA using cotyloplasty. The average patient age was 47 years. The diagnoses included dysplastic hip (12) and infection sequelae (4). All the patients were followed up for at least 2 years. Clinically, the Harris hip scores were assessed and radiologically, the amount of cup protrusion, the hip center movement and cup fixation were evaluated. RESULTS: The average Harris hip score improved from 57 to 94 postoperatively. The average proportion of cup surface beyond the Kohler line was 44.1% and the hip centers were medialized by an average of 23 mm. Stable fixation of the acetabular cup was achieved in all the cases except one. In this one case, migration of the cup was detected 2 weeks postoperatively and a reoperation was performed. CONCLUSIONS: Using cotyloplasty, good coverage of the acetabular cup was obtained without a block bone graft, and the hip joint centers were medialized. However, the safety margin for the amount of protrusion should be established.
Acetabulum/*pathology/radiography/*surgery
;
Adult
;
Arthritis, Infectious/complications/pathology
;
*Arthroplasty, Replacement, Hip
;
Female
;
Hip Dislocation, Congenital/pathology/surgery
;
Hip Joint/radiography
;
*Hip Prosthesis
;
Humans
;
Male
;
Middle Aged
3.A method for automatic selection of optimal standard hip stems.
Ruyu MA ; Wendong XUE ; Kerong DAI ; Chengtao WANG
Journal of Biomedical Engineering 2005;22(6):1256-1258
In a hip replacement case when a standard hip stem is chosen, it is rough to select hip stems before operation, thus some stand-up standard hip stems should be prepared. The operation time is usually prolonged. In order to solve this problem, this paper presents a method to automatically select optimal standard hip stems by computers. Femoral anatomical data of a patient are acquired from X-ray films. Based on these anatomical data and a database of average cross-sections in proximal femurs, proximal femur of the patient can be reconstructed. This proximal femur model makes it possible to optimally select a standard hip stem. Theory analyses indicate that the method, presented in this paper, is practicable.
Arthroplasty, Replacement, Hip
;
instrumentation
;
Computer-Aided Design
;
Hip Joint
;
diagnostic imaging
;
surgery
;
Hip Prosthesis
;
standards
;
Humans
;
Radiography
5.Radiological Assessment of the Sacrofemoral Angle: A Novel Method to Measure the Range of Hip Joint Flexion.
Xian-Zhao WEI ; Xi-Ming XU ; Fei WANG ; Ming LI ; Zi-Min WANG
Chinese Medical Journal 2015;128(17):2318-2321
BACKGROUNDA quantitative and accurate measurement of the range of hip joint flexion (RHF) is necessarily required in the evaluation of disordered or artificial hip joint function. This study aimed to assess a novel method to measure RHF more accurately and objectively.
METHODSLateral radiographs were taken of 31 supine men with hip joints extended or flexed. Relevant angles were measured directly from the radiographs. The change in the sacrofemoral angle (SFA) (the angle formed between the axis of the femur and the line tangent to the upper endplate of S1) from hip joint extension to hip joint flexion, was proposed as the RHF. The validity of this method was assessed via concomitant measurements of changes in the femur-horizontal angle (between the axis of the femur and the horizontal line) and the sacrum-horizontal angle (SHA) (between the line tangent to the upper endplate of S1 and the horizontal line), the difference of which should equal the change in the SFA.
RESULTSThe mean change in the SFA was 112.5 ± 7.4°, and was independent of participant age, height, weight, or body mass index. The mean changes in the femur-horizontal and SHAs were 123.0 ± 6.4° and 11.4 ± 3.0°, respectively. This confirmed that the change of SFA between hip joint extension and hip joint flexion was equal to the difference between the changes in the femur-horizontal and SHAs.
CONCLUSIONSUsing the SFA, to evaluate RHF could prevent compromised measurements due to the movements of pelvis and lumbar spine during hip flexion, and is, therefore, a more accurate and objective method with reasonable reliability and validity.
Adult ; Hip Joint ; diagnostic imaging ; surgery ; Humans ; Male ; Radiography ; Range of Motion, Articular ; physiology ; Sacrum ; diagnostic imaging ; surgery ; Young Adult
6.MR-based Parameters as a Supplement to Radiographs in Managing Developmental Hip Dysplasia.
Hui Taek KIM ; In Bo KIM ; Jong Seo LEE
Clinics in Orthopedic Surgery 2011;3(3):202-210
BACKGROUND: Some dysplastic hips with favorable radiographic parameters fail to develop normally, suggesting that we should consider cartilaginous or soft tissue structures for further information regarding the condition of the hip. The purpose of this study was to provide a clear definition of concentric reduction in developmental dysplasia of the hip (DDH) based on magnetic resonance imaging (MRI), and to determine how radiographic and MR-based parameters could be used together to treat dysplastic hips. METHODS: We studied range of motion (ROM)-MRI of 25 patients with unilateral hip dysplasia (mean age at the time of MR imaging, 44.1 months). Each ROM-MRI consisted of a set of bilateral hip scans in the following positions: neutral; abduction; abduction- internal rotation; abduction-internal rotation-flexion; and adduction. Before MR scanning, the 25 patients received the following primary treatments: closed reduction (n = 15; at a mean age of 14.5 months); and open reduction (n = 10; at a mean age of 10.0 months). The following new parameters appear to be useful in treating DDH: 1) the labral angle, the angle the labrum makes with the acetabulum; 2) the uncorrected labral deformity (ULD), the "residual deformity" (deflection of the labrum) when the affected labrum is freed from pressure in abduction; and 3) the zone of compressive force (ZCF), the region of the acetabulum through which the body weight acts on the femoral head. RESULTS: A concentrically-reduced hip is one in which the labrum points downward in the neutral position, at the same angle as that of the normal side; and in which the ZCF is zone 3, the inner acetabular zone as defined herein. The ULD and the ZCF may be determined precisely as we have done, or the physician may simply observe the changes in the orientation of the labrum and compare the changes qualitatively to the unaffected side, and likewise for the medial joint space. CONCLUSIONS: Detailed analysis of the labrum as permitted by ROM-MRI, together with acetabular index and other parameters measured from radiographs, provides important information for physicians treating childhood hip dysplasia.
Child, Preschool
;
Female
;
Hip Dislocation, Congenital/*diagnosis/physiopathology/radiography/surgery
;
Hip Joint/pathology/physiopathology/radiography
;
Humans
;
Infant
;
*Magnetic Resonance Imaging
;
Male
;
Range of Motion, Articular
7.Are Portable Imaging Intraoperative Radiographs Helpful for Assessing Adequate Acetabular Cup Positioning in Total Hip Arthroplasty?.
Sang Won PARK ; Jong Hoon PARK ; Seung Beom HAN ; Gi Won CHOI ; Dong Ik SONG ; Eun Soo AN
Journal of Korean Medical Science 2009;24(2):315-319
Despite advances in surgical techniques and instrumentation, current intra-operative estimations of acetabular version in total hip arthroplasty are of limited accuracy. In the present study, two experienced orthopedic surgeons compared intra-operatively measured (using portable imaging) anteversions and vertical inclinations of acetabular components with those measured using standardized radiographs post-operatively in 40 patients. Of the all vertical inclinations measured from intra-operative radiographs, 72.5% (n=29) were within +/-2degrees, and 97.5% (n=39) were within +/-5degrees of those determined using post-operative radiographs, and for anteversion, 52.5% (n=21) were within +/-2degrees, and 97.5% (n=39) were within +/-5degrees. Post-operative radiographs demonstrated that 90.0% (n=36) of vertical inclinations and anteversions were within the adequate zone. Obviously, our method has its limitations, but the authors conclude that the method described in this article better allows surgeons to verify acetabular version intra-operatively. In particular, the described method is suitable in cases with a deformed acetabular anatomy and difficult revision surgery.
Acetabulum/radiography/*surgery
;
Adult
;
Aged
;
Aged, 80 and over
;
*Arthroplasty, Replacement, Hip
;
Female
;
Hip Joint/*radiography/surgery
;
Hip Prosthesis
;
Humans
;
Imaging, Three-Dimensional/methods
;
Intraoperative Care/*instrumentation/methods
;
Male
;
Middle Aged
;
Prosthesis Fitting
8.Contemporary Ceramic Total Hip Arthroplasty in Patients with Cerebral Palsy: Does It Work?.
Byung Ho YOON ; Young Kyun LEE ; Yong Chan HA ; Kyung Hoi KOO
Clinics in Orthopedic Surgery 2015;7(1):39-45
BACKGROUND: Adult patients with cerebral palsy (CP), who have advanced degenerative arthritis of the hip, have been treated with resection arthroplasty and arthrodesis. Although total hip arthroplasty (THA) has also been used as one of the alternative options, there are few studies on contemporary bearings used in THA. Therefore, we evaluated the results of the contemporary ceramic-on-ceramic THA in adult patients with CP. METHODS: From January 2005 to December 2007, five adult CP patients (5 hips) underwent THA using contemporary ceramic-on-ceramic bearings. All patients were able to stand or ambulate with intermittent use of assistive devices at home. We retrospectively reviewed the series to determine the results of THA in terms of pain relief, improved function, and durability of prosthesis. RESULTS: There were 3 men and 2 women with a mean age of 35.9 years. All patients had pain relief without decline in mobility postoperatively. One hip was dislocated, which was treated successfully with closed reduction and an abduction brace for 2 months. There was no ceramic fracture, loosening, or osteolysis during the mean follow-up of 6.8 years (range, 5.8 to 8.3 years). CONCLUSIONS: Cementless THA using contemporary ceramic-on-ceramic bearings is a useful option for the treatment of advanced degenerative arthritis of the hip in ambulatory adults with CP.
Adult
;
Arthroplasty, Replacement, Hip/*methods
;
Biocompatible Materials
;
Ceramics
;
Cerebral Palsy/*complications
;
Female
;
Hip Joint/*surgery
;
Hip Prosthesis
;
Humans
;
Male
;
Osteoarthritis, Hip/etiology/radiography/*surgery
;
Prosthesis Design
;
Retrospective Studies
;
Treatment Outcome
9.Clinical and radiographic evaluation for total hip arthroplasty in treatment of bony ankylosis of hips.
Wei FENG ; Jian-Guo LIU ; Xin QI ; Dong-Song LI ; Chen YANG ; Shu-Qiang LI ; Li FU
China Journal of Orthopaedics and Traumatology 2012;25(11):899-902
OBJECTIVETo evaluate the clinical and radiographic effects of total hip arthroplasty (THA) in the treatment of bony ankylosis of hips.
METHODSFrom January 2003 to August 2009, 20 patients (30 hips) with bony ankylosis of hips were treated with THA. There were 12 males and 8 females, with an average age of 36 years old. After operation, the follow-up results were evaluated with clinical and radiographic criteria. The clinical follow-up results were evaluated with Harris score, satisfaction of pain relief, limb length discrepancy, ROM of hip and the strength of hip abductor. The X-ray imaging follow-up results were evaluated with acetabula and periprosthetic osteolysis, prosthesis loosening, radiolucent and heterotopic ossification.
RESULTSThe average following-up was 4 years. The mean preoperative Harris score was (40.75 +/- 6.52) as opposed to postoperative Harris score of (86.40 +/- 5.42). Total pain relief was 65% and partial pain relief was 35% around the affected hips. The recovery of abductors strength was satisfactory in 13 cases, with limp symptoms was relieved obviously, and limb shortening decreased to less than 0.5 cm. The postoperative ROM of hip was significantly improved compared with the preoperative ROM. Radiographic analysis showed that heterotopic ossification in 2 cases, and radiolucent around prosthesis in one case. There were no dislocation and revision cases.
CONCLUSIONThe THA can provide satisfactory clinical results in bony ankylosis of hips, which not only correct the deformity and recover the functions of hip, but also relieve the pain of hip to improve quality of life.
Adult ; Ankylosis ; diagnostic imaging ; physiopathology ; surgery ; Arthroplasty, Replacement, Hip ; methods ; Female ; Hip Joint ; physiopathology ; Humans ; Male ; Middle Aged ; Radiography ; Range of Motion, Articular
10.The Result of Revision Total Hip Arthroplasty in Patients with Metallosis Following a Catastrophic Failure of a Polyethylene Liner.
Hong Suk KWAK ; Jeong Joon YOO ; Young Kyun LEE ; Kyung Hoi KOO ; Kang Sup YOON ; Hee Joong KIM
Clinics in Orthopedic Surgery 2015;7(1):46-53
BACKGROUND: Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and infiltration of the metal particles in this catastrophic condition. METHODS: Twenty-three hips of 23 patients were identified because they showed metallosis during revision total hip arthroplasties performed in Seoul National University Hospital between January 1996 and August 2004. They were followed for at least 6.5 years after the index revision total hip arthroplasty. The clinical and radiological results of revision total hip arthroplasties in these patients were evaluated. RESULTS: The median Harris hip score increased from 60 points before revision total hip arthroplasties to 90 points at the final follow-up. Osteolysis was detected at an average of 9.3 years after revision total hip arthroplasties in 13 hips and acetabular cup loosening at average 9.8 years after revision total hip arthroplasties in 9 hips. With radiographic evidence of osteolysis and loosening as the end points, the 15-year survival rates were 28.2% and 56.0%, respectively. CONCLUSIONS: The survival rate of revision total hip arthroplasty in patients with metallosis following a catastrophic failure of a PE liner was low.
Adolescent
;
Adult
;
*Arthroplasty, Replacement, Hip
;
Biocompatible Materials
;
Female
;
Hip Joint/radiography/surgery
;
Hip Prosthesis/*adverse effects
;
Humans
;
Joint Diseases/radiography/*surgery
;
Male
;
Metals/adverse effects
;
Metals, Heavy/*poisoning
;
Middle Aged
;
Osteolysis/etiology/surgery
;
Poisoning/etiology/*surgery
;
Polyethylene/adverse effects
;
Prosthesis Design
;
*Prosthesis Failure/etiology
;
Reoperation
;
Young Adult