1.Helical CT Cholangiography with Multiplanar Reformation: Utility in Patients with Extrahepatic Biliary Obstruction.
Heoung Keun KANG ; Jae Kyu KIM ; Hyon De CHUNG ; Woong YOON ; Heoung Kil KIM ; Yun Hyun KIM ; Yong Yeon JEONG
Journal of the Korean Radiological Society 1995;33(6):939-944
PURPOSE: The purpose of this study was to evaluate the utility of the CT cholangiography by using helical CT with multiplanar reformation in patients with extrahepatic biliary obstruction. MATERIALS AND METHODS: Helical CT was performed in 36 patients of extrahepatic biliary obstruction confirmed by operation or invasive cholangiography(percutaneous transhepatic cholangiography or endoscopic retrograde cholagiopancreatography). The cause of obstructions were 18 benign diseases(11 common bile duct stones, four choledochal cysts, three pancreatitis) and 18 malignant diseases(seven common bile duct carcinomas, seven pancreatic head carcinomas, three ampullary carcinomas, one periampullary duodenal carcinoma). After helical scanning through the extrahepatic bile duct, retrospective reconstruction of the helical data was performed. And then, CT cholagiogram was obtained with multiplanar reformation. We evaluated the technical success rate and the accuracy in determinating the level and the cause of the obstruction. We compared findings of the CT cholangiogram with that of operation or invasive cholangiography. RESULTS: In 100%(36/36) of cases, CT cholangiography could be obtained successfully. The accuracy of the CT cholangiography in determinating the level of the obstruction was 100%(11 cases of suprapancreatic duct, 13 cases of intrapancreatic duct, 13 cases of infrapancreatic duct and ampulla), and the accuracy in determinating the cause of the obstruction was 91.7%(all cases of 18 benign diseases, and 15 cases of 18 malignant diseases). CONCLUSION: In evaluating the obstruction of extrahepatic bile ducts, the CT cholangiography by using helical CT with multiplanar reformation is an useful noninvasive method in determinating the level.and the cause of biliary obstruction and therefore could replace t~e invasive cholangiography.
Bile Ducts, Extrahepatic
;
Cholangiography*
;
Choledochal Cyst
;
Common Bile Duct
;
Head
;
Humans
;
Retrospective Studies
;
Tomography, Spiral Computed*
2.Recanalization of Superficial Femoral Artery By Retrograde Approach Via Popliteal Artery.
Heoung Keun KANG ; Jeong Jin SEO ; Jae Kyu KIRN ; Hyung Kil KIM ; Ung YUN
Journal of the Korean Radiological Society 1995;33(3):357-360
PURPOSE: To recanalize the occlusive lesion of superficial femoral artery at origin site by retrograde approach via popliteal artery. MATERIALS AND METHODS: 15 patients, who were poor surgical candidates due to coronary artery disease and who had severe occlusive lesion of superficial femoral artery close to its origin with good distal runoffs to popliteal artery, were selected. Patients were all~men and range of age were from 53 years to 66 years (mean age:63 years). Range of lesion length were from 15cm to 30cm (mean length:22.4cm). Localization of popliteal artery was done with Doppler stethoscope or "road-map" DSA. The method of recanalization were transluminal endarterectomy catheter (TEC), TEC and angioplasty, thrombolysoangioplasty (TLA). RESULT: Retrograde puncture of popliteal artery were done in 15 patients successfully. TEC & PTA was performed in 9 patients, TEC only in 2 patients, and TLA & PTA in 2 patients. During the follow-up period of 5 months to 2 years reocclusion did not occurr in 10 patients except for 1 patient with poor cardiac output in whom it occured 1 day later. Remained 4 patients were lost in follow up. Any neurologic or vascular complication did not occur. CONCLUSION: Retrograde approach of superficial fernoral artery via popliteal artery in patients with difficult vascular intervention by common method provides a useful, alternative recanalization method.
Angioplasty
;
Arteries
;
Cardiac Output
;
Catheters
;
Coronary Artery Disease
;
Endarterectomy
;
Femoral Artery*
;
Follow-Up Studies
;
Humans
;
Popliteal Artery*
;
Punctures
;
Stethoscopes
3.Utility of Multiplanar Reformation Images of Helical CT in the Evaluation of Pancreatic Diseases.
Jun Ho KIM ; Hyun Jong KIM ; Heoung Keun KANG ; Yun Hyeon KIM ; Jong Hoon YOON ; Hyeong Kil KIM
Journal of the Korean Radiological Society 1995;33(2):273-278
PURPOSE: The purpose of this study is to assess the clinical utility of multiplanar reformation images of helical CT in the evaluation of pancreatic diseases. MATERIALS AND METHODS: Helical CT scans of the pancreas were obtained in 30 patients with pancreatic diseases. Helical CT was performed with 5mm collimation at 5mm/sec table speed during rapid injection of intravenous contrast agent using power injector. After scanning, helical volume data were reconstructed at 2mm interval and then multiplanar reformation of the pancreas and adjacent structures was done. In both prospective reconstructed axial images and multiplanar reformation images, detection of pancreatic lesion, extent of lesion, and vascular and bile ductal changes were analyzed with a grading system of 1,2, 3. RESULTS: The mean grade of detection of pancreatic lesions was 2.37 in the prospective axial image and 2.83 in multiplanar reformation image, extent of diseases was 2.40 in prospective axial image and 2.97 in multiplanar reformation image, and vascular and bile ductal changes was 2.00 in the prospective axial image and 2.97 in multiplanar reformation image. All the differences were statistically significant (P<0.0001). CONCLUSION: Multiplanar reformation images of helical CT are useful in the evaluation of pancreatic diseases and especially in the demonstratibn of complex anatomic relationships between the pancreas and surrounding structures.
Bile Ducts
;
Humans
;
Pancreas
;
Pancreatic Diseases*
;
Prospective Studies
;
Tomography, Spiral Computed*
4.MR Findings of Congenital Craniocerebral Anomaly: Correlation with Seizures and Developmental Delay.
Heoung Keun KANG ; Jeong Jin SEO ; Hyon De CHUNG ; Yun Hyeon KIM ; Seog Wan KO ; Jong Hun YOON ; Hyun Ju KIRN ; Hyeong Kil KIM
Journal of the Korean Radiological Society 1995;33(1):7-14
PURPOSE: To evaluate characteristic MR findings of craniocerebral anomaly and its relationship with neurologic manifestations. MATERIALS AND METHODS: We retrospectively reviewed MR images of 36 patients with craniocerebral anomaly diagnosed by MRI and clinical courses. We correlated the characteristic MR findings in 41 lesions with neurologic manifestastions focusing on seizures and developmental delay. RESULTS: Twenty-three patients with seizures consisted of 14 patients(60%) with neuronal migration disorders and seven(30%) with phakomatosis, among which 18 patients(78%) had generalized type of seizures. Locations of the lesions were the parietal lobes in 11 patients(52%) and the subependymal or periventricular regions in seven(33%). Two patients with tuberous sclerosis had the lesions in both parietal and subependymal areas. Nine patients had the signs of developmental delay that were seen in the four(44%) with schizencephaly, two (22%) with tuberous sclerosis, two(22%) with heterotopia, and one(ll %) with pachygyria. CONCLUSION: Neuronal migration anomaly was relatively common lesion that presented neurologic manifestations such as seizures and developmental delay. Generalized type of seizures was common. We were able to diagnose these anomalies using the MRI that helped establish therapeutic plans.
Humans
;
Lissencephaly
;
Magnetic Resonance Imaging
;
Malformations of Cortical Development
;
Neurocutaneous Syndromes
;
Neurologic Manifestations
;
Neuronal Migration Disorders
;
Neurons
;
Parietal Lobe
;
Rabeprazole
;
Retrospective Studies
;
Seizures*
;
Tuberous Sclerosis
5.The Usefulness of CT and MR Virtual Colonoscopy in the Evaluation of Experimental Polyp Models.
Asiry HWANG ; Heoung Keun KANG ; Yong Yeon JEONG ; Eun Hye KO ; Jeong Jin SEO ; Yun Hyeon KIM ; Tae Woong CHUNG ; Hyeong Kil KIM ; Gwang Woo JEONG
Journal of the Korean Radiological Society 1999;41(4):739-744
PURPOSE: The purpose of this study was to evaluate the diagnostic accuracy of CT and MR virtual colonoscopy using an experimental model of colonic polyposis. MATERIALS AND METHODS: Eleven pig colons ranging from 15 to 20cm in length were cleansed and a total of 99 variable sized polyps ranging from 3 to 15mm in diameter were created. The polyps were divided into three groups according to size: <5mm(n=23), 5-9mm(n=44), and ?10mm(n=32) in diameter. Each specimen was scanned using spiral CT and MRI. Each CT and MR virtual colonoscopy was independently evaluated by two radiologists blinded to the location, size and numbers of polyps, but aware that polyps were present. Interobserver agreement regarding the detection rate of the polyps during the two types of virtual colonoscopy was measured and the diagnostic accuracy of CT and MR virtual colonoscopy was compared. Results: In both CT and MR virtual colonoscopy, the detection rates determined by the two radiologists coincided in all three groups(p<0.05). The detection rates of polyps less than 5mm, between 5 and 9mm, and 10mm or larger in diameter were 74%(17/23), 89%(39/44), and 100%(32/32), respectively, in CT colonoscopy, and 61%(14/23), 89%(39/44), and 100%(32/32), respectively in MR colonoscopy. In polyps 5mm or larger, the results of the two types of virtual colonscopy coincided but in those less than 5mm in diameter, the results of MR virtual colonoscopy were slightly inferior to those of CT colonoscopy. Conclusion: Both CT and MR virtual colonoscopy provide high detection rates of colonic polyps 5mm or larger in diameter and these techniques can therefore be used to diagnose colonic mass lesions.
Colon
;
Colonic Polyps
;
Colonography, Computed Tomographic*
;
Colonoscopy
;
Magnetic Resonance Imaging
;
Models, Theoretical
;
Polyps*
;
Tomography, Spiral Computed
6.The Usefulness of CT and MR Virtual Colonoscopy in the Evaluation of Experimental Polyp Models.
Asiry HWANG ; Heoung Keun KANG ; Yong Yeon JEONG ; Eun Hye KO ; Jeong Jin SEO ; Yun Hyeon KIM ; Tae Woong CHUNG ; Hyeong Kil KIM ; Gwang Woo JEONG
Journal of the Korean Radiological Society 1999;41(4):739-744
PURPOSE: The purpose of this study was to evaluate the diagnostic accuracy of CT and MR virtual colonoscopy using an experimental model of colonic polyposis. MATERIALS AND METHODS: Eleven pig colons ranging from 15 to 20cm in length were cleansed and a total of 99 variable sized polyps ranging from 3 to 15mm in diameter were created. The polyps were divided into three groups according to size: <5mm(n=23), 5-9mm(n=44), and ?10mm(n=32) in diameter. Each specimen was scanned using spiral CT and MRI. Each CT and MR virtual colonoscopy was independently evaluated by two radiologists blinded to the location, size and numbers of polyps, but aware that polyps were present. Interobserver agreement regarding the detection rate of the polyps during the two types of virtual colonoscopy was measured and the diagnostic accuracy of CT and MR virtual colonoscopy was compared. Results: In both CT and MR virtual colonoscopy, the detection rates determined by the two radiologists coincided in all three groups(p<0.05). The detection rates of polyps less than 5mm, between 5 and 9mm, and 10mm or larger in diameter were 74%(17/23), 89%(39/44), and 100%(32/32), respectively, in CT colonoscopy, and 61%(14/23), 89%(39/44), and 100%(32/32), respectively in MR colonoscopy. In polyps 5mm or larger, the results of the two types of virtual colonscopy coincided but in those less than 5mm in diameter, the results of MR virtual colonoscopy were slightly inferior to those of CT colonoscopy. Conclusion: Both CT and MR virtual colonoscopy provide high detection rates of colonic polyps 5mm or larger in diameter and these techniques can therefore be used to diagnose colonic mass lesions.
Colon
;
Colonic Polyps
;
Colonography, Computed Tomographic*
;
Colonoscopy
;
Magnetic Resonance Imaging
;
Models, Theoretical
;
Polyps*
;
Tomography, Spiral Computed
7.Comparison between Spiral CT and MR Imaging in Evaluation of Focal Hepatic Masses.
Yong Ho CHO ; Heoung Keun KANG ; Yong Yeon JEONG ; Hyeoung Kil KIM ; Man Won YOON ; Gwang Woo JEONG ; Tae Woong CHUNG
Journal of the Korean Radiological Society 2000;43(5):591-598
PURPOSE: The main aim of this study was to compare spiral CT and MR imaging in the detection and characterization of focal hepatic masses. MATERIALS AND METHODS: Seventy-nine patients with 155 focal hepatic masses confirmed pathologically, or radiologically and clinically [hepatocellular carcinoma(HCC) (n =52), hemangioma (n=36), cysts (n =35), metastasis (n =27), intrahepatic cholangiocarcinoma (n =5)], underwent two- or three-phase spiral CT, and T1-, T2- weighted, and dynamic contrast-enhanced MR imaging. The detection and characterization of focal hepatic masses by these modalities were evaluated and compared. RESULT: The detection rates of spiral CT and MR imaging, respectively, were as follows: HCC, 81%(42/52) and 94%(49/52); hemangioma, 75%(27/36) and 100%(36/36); cysts, 80%(28/35) and 100%(35/35); metastasis, 67%(18/27) and 100%(27/27); and intrahepatic cholangiocarcinoma, 100%(5/5) and 100%(5/5). MR imaging was superior to spiral CT in mass detection of HCC, hemangioma, cysts, and metastasis (p < .05). The characterization rates of spiral CT and MR imaging, respectively, were as follows: HCC, 52%(27/52) and 71%(37/52); hemangioma, 67%(24/36) and 100%(36/36); cysts, 63%(22/35) and 100%(35/35); metastasis, 37%(10/27) and 100%(27/27); and intrahepatic cholangiocarcinoma, 40%(2/5) and 80%(4/5). In the mass characterization of HCC, hemangioma, cysts, and metastasis, MR imaging was superior to spiral CT (p< .05). CONCLUSION: In the detection and characterization of focal hepatic masses, including hepatocellular carcinoma, hemangioma, hepatic cyst and metastasis, MR imaging is superior to spiral CT.
Carcinoma, Hepatocellular
;
Cholangiocarcinoma
;
Hemangioma
;
Humans
;
Magnetic Resonance Imaging*
;
Neoplasm Metastasis
;
Tomography, Spiral Computed*
8.Virtual Endoscopy Using Spiral CT in Patients with Carcinomas of the Hypopharynx and Larynx.
Sang Gook SONG ; Jeong Jin SEO ; Tae Woong CHUNG ; Hyeong Kil KIM ; Gwang Woo JEONG ; Yong Yeon JEONG ; Heoung Keun KANG ; Jae Sik CHO
Journal of the Korean Radiological Society 2000;42(5):715-720
PURPOSE: To compare the usefulness of virtual endoscopy using spiral CT with that of laryngoscopy in the detection and evaluation of laryngeal and pharyngeal carcinomas. MATERIALS AND METHODS: Twenty-four patients with pathologically proven laryngeal and pharyngeal carcinomas underwent laryngoscopy and virtual endoscopy using spiral CT. Eleven of the carcinomas were supraglottic, five were glottic, and eight were hypopharyngeal. Source images obtained by spiral CT were transmitted to an independent workstation and virtual endoscopic images were obtained using Navigator software. These were graded according to their quality (good, fair, bad), and were interpreted by two radiologists who were blinded to the conventional endoscopic findings. These latter were subsequently compared with the virtual endoscopic findings in terms of similarity to laryngoscopic examination and detectability of lesions. RESULTS: The overall image quality of virtual endoscopy was good in 16 cases (67%), fair in eight (33%), and bad in no case. Among the 11 supraglottic carcinomas, image quality was good in seven cases (64%), and fair in four (36%). In four of the five glottic carcinomas (80%) quality was good, and in one case (20%) it was fair, while among the eight hypopharyngeal carcinomas, quality was good in five cases (63%), and fair in three (37%). Overall, detection of the lesion was possible in 23 cases (96%). Due to the small size of the lesion, the CONCLUSION: Virtual endoscopy using spiral CT is a safe and noninvasive method, and also successfully detects laryngeal and pharygenal lesions, with good image quality. For the evaluation of laryngeal and hypopharyngeal carcinoma, its use may complement that of axial CT.
Complement System Proteins
;
Endoscopy*
;
Humans
;
Hypopharynx*
;
Laryngoscopy
;
Larynx*
;
Tomography, Spiral Computed*
9.Korean Nosocomial Infections Surveillance System, Intensive Care Unit Module Report: Summary of Data from July 2011 through June 2012.
Min Hyok JEON ; Tae Hyong KIM ; Sung Ran KIM ; Hee Kyung CHUN ; Su Ha HAN ; Ji Hwan BANG ; Eun Suk PARK ; Sun Young JEONG ; Joong Sik EOM ; Young Keun KIM ; Kil Yeon LEE ; Hee Jung CHOI ; Hyo Youl KIM ; Kyung Mi KIM ; Joohon SUNG ; Young UH ; Hong Bin KIM ; Heoung Soo CHUNG ; Jun Wook KWON ; Jun Hee WOO
Korean Journal of Nosocomial Infection Control 2014;19(2):52-63
BACKGROUND: This article reports annual data of intensive care units (ICU) module of the Korean Nosocomial Infections Surveillance (KONIS) system from July 2011 through June 2012. METHODS: We performed a prospective surveillance of nosocomial urinary tract infections (UTI), bloodstream infections (BSI), and pneumonia (PNEU) at 143 ICUs in 81 hospitals using the KONIS system. Nosocomial infection (NI) rates were calculated as the number of infections per 1,000 patient days or device days. Asymptomatic bacteriuria was excluded on or after October 1, 2011. RESULTS: A total of 3,374 NIs were found during the study period: 1,356 UTIs (1,336 cases were urinary catheter-associated), 1,253 BSIs (1,091 were central line-associated), and 765 PNEUs (481 were ventilator-associated). The rate of urinary catheter-associated UTIs (CAUTIs) was 2.26 cases per 1,000 device-days (95% confidence interval, 2.14-2.39) and urinary catheter utilization ratio was 0.85 (0.849-0.851). The rate of central line-associated BSIs was 3.01 (2.84-3.19) and the utilization ratio was 0.52 (0.519-0.521). The rate of ventilator-associated PNEUs (VAPs) was 1.70 (1.56-1.86) and the utilization ratio was 0.40 (0.399-0.401). Ventilator and urinary catheter utilization ratios were lower in the ICUs of hospitals with 400-699 beds than those in hospitals with 700-899 beds or more than 900 beds. Nevertheless, VAPs and CAUTIs were more common in hospitals with 400-699 beds. CONCLUSION: Nosocomial infection rates were similar to the findings of those of the previous period, July 2010-July 2011. Implementation of proven infection-control strategies are needed, especially in the hospitals having fewer than 700 beds.
Bacteriuria
;
Cross Infection*
;
Humans
;
Intensive Care Units*
;
Pneumonia
;
Prospective Studies
;
Urinary Catheters
;
Urinary Tract Infections
;
Ventilators, Mechanical
10.Korean Nosocomial Infections Surveillance System, Intensive Care Unit Module Report: Data Summary from July 2010 through June 2011.
Min Hyok JEON ; Wan Beom PARK ; Sung Ran KIM ; Hee Kyung CHUN ; Su Ha HAN ; Ji Hwan BANG ; Eun Suk PARK ; Sun Young JEONG ; Joong Sik EOM ; Young Keun KIM ; Hong Bin KIM ; Kil Yeon LEE ; Hee Jung CHOI ; Hyo Youl KIM ; Kyung Mi KIM ; Joo Hon SUNG ; Young UH ; Heoung Soo CHUNG ; Jun Wook KWON ; Jun Hee WOO
Korean Journal of Nosocomial Infection Control 2012;17(1):28-39
BACKGROUND: We present here the annual data of the intensive care unit (ICU) module of the Korean Nosocomial Infections Surveillance System (KONIS) from July 2010 through June 2011. METHODS: We performed a prospective surveillance of nosocomial urinary tract infections (UTI), bloodstream infections (BSI), and pneumonia (PNEU) at 130 ICUs in 72 hospitals using KONIS. Nosocomial infection (NI) rates were calculated as the number of infections per 1,000 patient-days or device-days. RESULTS: A total of 3,757 NIs were found: 1,978 UTIs (1,949 cases were urinary catheter-associated), 1,092 BSIs (with 932 being central line-associated), and 687 PNEUs (410 were ventilator-associated). The rate of urinary catheter-associated UTIs (CAUTIs) was 3.87 cases per 1,000 device-days (95% confidence interval, 3.70-4.05), and the urinary catheter utilization ratio was 0.86 (0.859-0.861). The rate of central line-associated BSIs was 3.01 per 1,000 device-days (2.82-3.21), and the utilization ratio was 0.53 (0.529-0.531). The rate of ventilator-associated PNEUs (VAPs) was 1.75 per 1,000 device-days (1.59-1.93), and the utilization ratio was 0.40 (0.399-0.401). Although both the ventilator utilization ratiosand the urinary catheter utilization ratios were lower in hospitals with 400-699 beds than thosein hospitals with 700-899 beds ormore than 900 beds, the rates of VAPsand CAUTIs were higher in hospitals with 400-699 beds than thosein hospitals with 700-899 beds or more than 900 beds. CONCLUSION: The risk of acquiring VAP and CAUTI is higher in the ICUs of 400-699 bed hospitals than in ICUs oflarger hospitals. Therefore, ongoing targeted surveillance and implementation of proven infection control strategies are needed especially for hospitals having fewer than 700 beds.
Benzamides
;
Cross Infection
;
Infection Control
;
Critical Care
;
Intensive Care Units
;
Pneumonia
;
Prospective Studies
;
Urinary Catheters
;
Urinary Tract Infections
;
Ventilators, Mechanical