1.Tissue culture of Swertia bimaculata
Hua LONG ; Xuefeng HU ; Hengyu HUANG
Chinese Traditional and Herbal Drugs 1994;0(03):-
Objective In order to protect the natural resources of Swertia bimaculata which has been destroyed seriously,the method of artificial propagation by way of tissue culture have been systematically studied.Methods The stems,leaves,and stems with buds which were from the seedlings germinated from the seeds on the initial medium were taken as explants.These explants were cultured on MS culture media by adding different portions of hormones at various cultural conditions.Results The stems were the best material in speeding propagation among the three explants.The proper initial medium for the stems was MS+ BA 0.5 mg/L+saccharose 3.0%,the optimum medium for proliferation was MS+BA 0.5 mg/L+IBA 0.1 mg/L+saccharose 3.0%,and the best medium for rooting was 1/2MS+NAA 0.5 mg/L+saccharose 1.5%.Conclusion Tissue culture of S.bimaculata could make its propagation rapid,its resources preserved,and its utilization last.
2.Quality control testing and performance evaluation of polysomnography
Jing HUANG ; Li YANG ; Aowen DUAN ; Li XU ; Zhenwei DU ; Hengyu LONG ; Anhai WEI ; Kexin PAN
China Medical Equipment 2024;21(5):123-127
Objective:To research the quality control and testing methods of polysomnography and to ensure its safe and effective performance.Methods:A quality control testing method was designed for the main indicators of EEG signal,EMG signal,ECG signal,and pulse oxygen saturation of polysomnography.In August 2023,two polysomnography instruments of the same brand and different models(marked as Test Equipment A and Test Equipment B)in clinical use in Daping Hospital,Army Medical University were selected.The quality control testing of polysomnography instrument was conducted by using electroencephalogram calibration instrument and vital sign simulator to evaluate the reliability of the performance of polysomnography.Results:A quality control testing method was developed for quality control testing of polysomnography aiming at the repeatability of the indicated values of EEG signals,EMG signals,ECG signals,and pulse oxygen saturation of polysomnography.Except for the output value of 2 mV of the voltage measurement simulator of test equipment B,the relative error of the recorded data was-11%,and the parameters were out of tolerance,and the rest of the test data of test equipment A and test equipment B met the maximum limit output value of the national metrology verification regulations and the technical requirements of the equipment manufacturer.Conclusion:The quality control detection method of polysomnography can evaluate the performance parameters of the selected testing equipment A and testing equipment B,and provide technical support for the quality control detection and safe use of such equipment.
3.Research on calibration method of endoscopic liquid expansion pump
Jing HUANG ; Aowen DUAN ; Li YANG ; Xiaobo WEN ; Haijiang ZHU ; Anhai WEI ; Hengyu LONG ; Hehua ZHANG
China Medical Equipment 2024;21(10):194-197
A corresponding calibration method was proposed for the key performance parameters of the endoscopic liquid expansion pump,such as the pressure indication error,the flow rate indication error and the flow rate repeatability.4 different brands of endoscopic liquid expansion pumps in clinical use in the hospital were selected for calibration,and the feasibility of the calibration method was evaluated.In the pressure and flow range of the endoscope liquid expansion pump,3 calibration points of high,medium and low were selected,and each flow point was calibrated 3 times.The calibration results showed that the maximum error of pressure indication was 4.3%,the maximum error of flow indication was 9.3%,and the maximum repeatability of flow indication value was 0.8%,all of which met the technical requirements for the maximum allowable error of"Medical Endoscopes.Endoscope Functional Supply Units.Irrigation Pump"(YY/T 0864-2011)and"Calibration Specification for Syringe Pumps and Infusion Pumps"(JJF 1259-2018).The calibration method for endoscopic liquid expansion pump can improve the metrological traceability system of this type of equipment,ensure the accuracy and reliability of equipment values,improve product quality,and ensure medical safety.