1.Clinical efficacy of Fu's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo and its effect on blood flow velocity of vertebral artery.
Meng GONG ; Zhixiang LIU ; Pei LI ; Renyan XIAO ; Peng JIA ; Hong GUO ; Song JIN
Chinese Acupuncture & Moxibustion 2025;45(1):13-18
OBJECTIVE:
To observe the clinical efficacy of Fu's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo (CV) and its effect on blood flow velocity of vertebral artery.
METHODS:
A total of 60 patients with CV were randomized into a Fu's subcutaneous needling group and a medication group, 30 cases in each one. In the Fu's subcutaneous needling group, Fu's subcutaneous needling was delivered at Dazhui (GV14), the flexible tube was retained for 5 min after sweeping manipulation, and the treatment was given once every other day, 3 times a week for 3 weeks. In the medication group, betahistine mesylate tablet and diclofenac sodium dual-release enteric capsule were taken orally for continuous 3 weeks. Before treatment, after treatment, and in follow-up of one month after treatment completion, the scores of dizziness handicap inventory (DHI) and visual analogue scale (VAS) were observed; before and after treatment, the blood flow velocity of vertebral artery was measured by transcranial Doppler, and the clinical efficacy was evaluated after treatment in the two groups.
RESULTS:
After treatment and in follow-up, each item scores and total scores of DHI were decreased compared with those before treatment in the two groups (P<0.05); the VAS scores after treatment in the two groups, as well as the VAS score in follow-up of the Fu's subcutaneous needling group, were decreased compared with those before treatment (P<0.05). In the Fu's subcutaneous needling group, after treatment and in follow-up, the physical scores and the total scores of DHI, and the VAS scores were lower than those in the medication group (P<0.05); in follow-up, the emotional and functional scores of DHI were lower than those in the medication group (P<0.05). After treatment, the mean blood flow velocity (Vm) of the left vertebral artery (LVA) and the right vertebral artery (RVA) was increased compared with that before treatment in the two groups (P<0.05), and the Vm of LVA and RVA in the Fu's subcutaneous needling group was higher than that in the medication group (P<0.05). The total effective rate was 100.0% (30/30) in the Fu's subcutaneous needling group, which was superior to 73.3% (22/30) in the medication group (P<0.05).
CONCLUSION
Fu's subcutaneous needling based on the "multi-joint muscle spiral balance chain" theory can effectively alleviate the vertigo and neck pain, and improve the blood flow velocity of vertebral artery in CV patients, and has a long-term therapeutic effect.
Humans
;
Female
;
Male
;
Middle Aged
;
Acupuncture Therapy/instrumentation*
;
Vertebral Artery/physiopathology*
;
Adult
;
Vertigo/physiopathology*
;
Aged
;
Blood Flow Velocity
;
Treatment Outcome
;
Acupuncture Points
;
Young Adult
2.Effect of Temperature Cycle Preservation on Platelet Aggregation Rate and Routine Parameters.
Ju-Ling LIANG ; Zhi-Hao DENG ; Chuang-Jin ZHUO ; Lu HUANG ; Jing XU ; Wei-Jian WU
Journal of Experimental Hematology 2025;33(1):236-240
OBJECTIVE:
To compare and analyze the changes of aggregation rate and routine parameters of platelets stored in temperature cycle, cold storage at 4 ℃ and oscillating storage at 22 ℃, so as to provide more experimental data for platelet preservation methods.
METHODS:
Blood samples were collected at 5 time points on the 1st, 2nd, 3rd, 4th and 6th day after platelet cycling preservation at temperature, cold storage at 4 ℃, and oscillating storage at 22 ℃. Platelet maximum aggregation rate (MAR) and routine parameters including platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW) and platelet-larger cell ratio (P-LCR) were detected.
RESULTS:
The platelet MAR of three groups showed a significant decrease trend with the preservation time, the fastest decrease was in the 22 ℃ group, the slowest was in the 4 ℃ group, and the temperature cycle group was between the two groups. On the 3rd day of preservation, the platelet MAR in 4 ℃ group was still in the normal range (MAR>60%), while in temperature cycle group was about 50%, and in 22 ℃ group was the lowest. On the 4th day of preservation, platelet MAR in all the three groups was lower than 50%, and that in temperature cycle group was significantly lower than in 4 ℃ group but higher than in 22 ℃ group (both P < 0.05). On the 6th day of preservation, platelet MAR in the temperature cycle group was significantly lower than that in the 4 ℃ group ( P <0.05), but there was no statistically significant difference compared to 22 ℃ group (P >0.05). PLT values in the three groups were all significantly decreased with the preservation time extension, and were significantly lower than those in the early stage of preservation within 6 days (all P < 0.05). PDW in temperature cycle group had no significant change within 6 days of preservation, but MPV and P-LCR were significantly increased. MPV, PDW and P-LCR all decreased significantly in 4 ℃ group within 6 days of preservation but increased in 22 ℃ group. Under the same storage days, PLT value of temperature cycle group had no significant difference with that of 4 ℃ group and 22 ℃ group, while MPV, PDW and P-LCR values were significantly higher than 4 ℃ group but lower than 22 ℃ group (all P < 0.05).
CONCLUSION
The aggregation function and routine parameters changes of temperature circulating preserved platelets are between 4 and 22 ℃.
Humans
;
Platelet Aggregation
;
Blood Preservation/methods*
;
Temperature
;
Blood Platelets
;
Platelet Count
;
Mean Platelet Volume
;
Cryopreservation/methods*
;
Cold Temperature
3.Effects of Oridonin on Platelet Function and Related Mechanisms.
Yu LI ; Rong YAN ; Meng-Nan YANG ; Kang-Xi ZHOU ; Ke-Sheng DAI
Journal of Experimental Hematology 2025;33(4):1104-1112
OBJECTIVE:
To investigate the effects of oridonin on platelet function and related mechanisms.
METHODS:
Washed platelets from healthy adults and mice were incubated with different concentrations of oridonin (2.5, 5 and 10 μmol/L) in vitro . The surface expression level of P-selectin and the activation of integrin αIIbβ3 in platelets were detected by flow cytometry, and the aggregation ability of platelets under the stimulation by various agonists was detected by light transmission aggregometry. The expression of P-AKT (Ser473) was detected by protein immunoblotting. Arterial thrombosis model was established in mice with mesenteric injury induced by ferric chloride, and tail hemorrhage model was established by cutting off the tail of mice. The effect of intraperitoneal injection of oridonin (10 mg/kg) on thrombosis and haemostasis was tested.
RESULTS:
Oridonin inhibited platelet P-selectin expression and integrin αIIbβ3 activation. In the presence of different stimulants, oridonin inhibited platelet aggregation in a concentration-dependent manner. The phosphorylation level of AKT Ser473 was reduced in the groups treated with different concentrations of oridonin. Oridonin significantly prolonged the time of mesenteric artery thrombosis in mice, but did not affect the tail bleeding time.
CONCLUSION
Oridonin inhibits platelet activation, aggregation, and thrombosis by inhibiting AKT phosphorylation, and may be used as a potential antiplatelet drug.
Diterpenes, Kaurane/pharmacology*
;
Animals
;
Mice
;
Blood Platelets/drug effects*
;
Platelet Aggregation/drug effects*
;
P-Selectin/metabolism*
;
Thrombosis
;
Platelet Glycoprotein GPIIb-IIIa Complex/metabolism*
;
Proto-Oncogene Proteins c-akt/metabolism*
;
Humans
;
Phosphorylation
;
Platelet Activation/drug effects*
4.Optimization of flow rate and orientation of outflow graft at implantation for patients with left ventricular assist device.
Yongyi WANG ; Li SHI ; Shijun HU ; Xiao TAN ; Tianli ZHAO
Journal of Central South University(Medical Sciences) 2025;50(3):457-468
OBJECTIVES:
A ventricular assist device (VAD) is an electromechanical device used to assist cardiac blood circulation, which can be employed for the treatment of end-stage heart failure and is most commonly placed in the left ventricle. Despite enhancing perfusion performance, the implantation of left ventricular assist device (LVAD) transforms the local intraventricular flow and thus may increase the risk of thrombogenesis. This study aims to investigate fluid-particle interactions and thromboembolic risk under different LVAD configurations using three-dimensional (3D) reconstruction models, focusing on the effects of outflow tract orientation and blood flow rates.
METHODS:
A patient-specific end-diastolic 3D reconstruction model was initially constructed in stereo lithography (STL) format using Mimics software based on CT images. Transient numerical simulations were performed to analyze fluid-particle interactions and thromboembolic risks for LVAD with varying outflow tract orientations under 2 flow rates (4 L/min and 5 L/min), using particles of uniform size (2 mm), and a blood flow rate optimization protocol was implemented for this patient.
RESULTS:
When the LVAD flow rate was 5 L/min, helicity and flow stagnation of the blood flow increased the particle residence time (RT) and the risk of thrombogenesis of the aortic root. The percentage of particles traveling toward the brachiocephalic trunk was up to 20.33%. When the LVAD flow rate was 4 L/min, blood turbulence in the aorta was reduced, the RT of blood particles was shortened, and then the percentage of particles traveling toward the brachiocephalic trunk decreased to 10.54%. When the LVAD blood flow rate was 5 L/min and the direction of the outflow pipe was optimal, the RT of blood particles was shortened, and then the percentage of particles traveling toward the brachiocephalic trunk decreased to 11.22%. A 18-month follow-up observation of the patient revealed that the LVAD was in good working order and the patient had no complications related to the implantation of LVAD.
CONCLUSIONS
Implantation of LVAD results in a higher risk of cerebral infarction; When implanting LVAD with the same outflow tract direction, optimizing flow velocity and outflow tract can reduce the risk of cerebral infarction occurrence.
Heart-Assist Devices/adverse effects*
;
Humans
;
Heart Failure/physiopathology*
;
Blood Flow Velocity
;
Thromboembolism/prevention & control*
;
Models, Cardiovascular
;
Heart Ventricles/physiopathology*
;
Imaging, Three-Dimensional
5.Prognostic value of difference between hematocrit and albumin in patients with sepsis.
Shaobo WANG ; Bin HUANG ; Yuxin XU ; Bingyu WEI ; Rongfang LONG ; Ying QIU
Chinese Critical Care Medicine 2025;37(7):633-637
OBJECTIVE:
To investigate the value of difference between hematocrit (HCT) and albumin (Alb) in predicting the prognosis of patients with sepsis.
METHODS:
A retrospective study was conducted on the septic patients hospitalized at the First Affiliated Hospital of Guangxi Medical University from January to October in 2024. Clinical data including gender, age, body mass index (BMI), history of hypertension or diabetes, vital signs on admission, and sequential organ failure assessment (SOFA) score, acute physiology and chronic health evaluation II (APACHE II) score, blood lactic acid (Lac), oxygenation index (PaO2/FiO2), hemoglobin (Hb), white blood cell count (WBC), platelet count (PLT), lymphocyte count (LYM), HCT, Alb, difference between HCT and Alb, bilirubin, scrum creatinine (SCr), and fibrinogen (Fib) within 48 hours of admission were collected. The 28-day prognosis of patients was also recorded. Binary multivariate Logistic regression analysis was used to identify risk factors for 28-day death in patients with sepsis. The predictive efficacy of the difference between HCT and Alb on 28-day death was evaluated using the receiver operator characteristic curve (ROC curve).
RESULTS:
Among 180 enrolled septic patients, 140 survived and 40 died on 28 days. Compared with the survival group, the patients in the death group was significantly older (years old: 64±16 vs. 55±15, P < 0.05), and had higher SOFA score, APACHE II score, and SCr [SOFA score: 6 (4, 9) vs. 3 (2, 5), APACHE II score: 13 (10, 18) vs. 8 (6, 11), SCr (μmol/L): 136 (70, 416) vs. 77 (58, 126), all P < 0.05] as well as lower Hb, PLT, HCT, difference between HCT and Alb, and Fib within 48 hours of admission [Hb (g/L): 90±30 vs. 106±79, PLT (×109/L): 158 (57, 240) vs. 215 (110, 315), HCT: 0.258±0.081 vs. 0.333±0.077, difference between HCT and Alb: -6.52±7.40 vs. 1.07±7.63, Fib (g/L): 3.72±1.57 vs. 4.59±1.55, all P < 0.05]. No significant difference in gender, BMI, history of hypertension or diabetes, vital signs on admission, or other laboratory indicators was found between the two groups. Binary multivariate Logistic regression analysis revealed that age [odds ratio (OR) = 1.040, 95% confidence interval (95%CI) was 1.004-1.078, P = 0.030], APACHE II score (OR = 1.218, 95%CI was 1.038-1.430, P = 0.016), Hb (OR = 1.040, 95%CI was 1.014-1.068, P = 0.003), and difference between HCT and Alb (OR = 0.804, 95%CI was 0.727-0.889, P < 0.001) were independent risk factors for 28-day death of septic patients. ROC curve analysis showed that the area under the ROC curve (AUC) of difference between HCT and Alb for predicting 28-day death of septic patients was 0.764 (95%CI was 0.679-0.849, P < 0.001). A cut-off value of difference between HCT and Alb ≤ -5.35 yielded a sensitivity of 80.7% and specificity of 65.0%.
CONCLUSIONS
The difference between HCT and Alb at early admission is a valuable predictor of prognosis in septic patients. A difference ≤ -5.35 indicates an increased death risk of septic patients.
Humans
;
Prognosis
;
Sepsis/blood*
;
Retrospective Studies
;
Hematocrit
;
Serum Albumin/analysis*
;
Male
;
Female
;
Middle Aged
;
Aged
;
APACHE
6.In Vitro Hydrodynamic Performance Evaluation of Valve Repair System.
Liang CAI ; Yibin LI ; Shiwen LYU
Chinese Journal of Medical Instrumentation 2024;48(6):603-606
OBJECTIVE:
To meet the treatment requirements for mitral regurgitation disease, this study designed a novel valve repair system and evaluated its hydrodynamic performance.
METHODS:
A mitral regurgitation model was created. The valve repair system was loaded onto the regurgitation model, and pulsatile flow tests and steady backflow leakage tests were conducted.
RESULTS:
The pulsatile flow test results indicated that the percentage of reflux after product implantation was lower than that before implantation under different concentric outputs and reverse pressures. The average cross-valve pressure difference after implantation was less than 5 mmHg. The steady backflow leakage test results showed that as the reverse pressure increased, the leakage amount of the valve repair system after implantation also increased.
CONCLUSION
The developed valve repair system exhibits excellent hydrodynamic performance, suggesting the feasibility of its application in the treatment of clinical mitral regurgitation.
Hydrodynamics
;
Mitral Valve Insufficiency/surgery*
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis
;
Pulsatile Flow
;
Heart Valve Prosthesis Implantation
9.Mechanism of Notch3 signaling pathway regulating the differentiation of aortic dissection vascular stem cells into smooth muscle cells.
Yichi HAN ; Haiwei HE ; Xin LI
Chinese Critical Care Medicine 2023;35(5):503-508
OBJECTIVE:
To explore whether the differentiation of vascular stem cells (VSC) into smooth muscle cells (SMC) in aortic dissection (AD) is dysregulated, and to verify the role of Notch3 pathway in this process.
METHODS:
Aortic tissues were obtained from AD patients undergoing aortic vascular replacement and heart transplant donors at Department of Cardiovascular Surgery, Guangdong Provincial People's Hospital Affiliated to Southern Medical University. VSC were isolated by enzymatic digestion and c-kit immunomagnetic beads. The cells were divided into normal donor-derived VSC group (Ctrl-VSC group) and AD-derived VSC group (AD-VSC group). The presence of VSC in the aortic adventitia was detected by immunohistochemical staining, and VSC was identified by stem cell function identification kit. The differentiation model of VSC into SMC established in vitro was induced by transforming growth factor-β1 (10 μg/L) for 7 days. They were divided into normal donor VSC-SMC group (Ctrl-VSC-SMC group), AD VSC-SMC group (AD-VSC-SMC group) and AD VSC-SMC+Notch3 inhibitor DAPT group (AD-VSC-SMC+DAPT group,DAPT 20 μmol/L was added during differentiation induction). The expression of contractile marker Calponin 1 (CNN1) in SMC derived from aortic media and VSC were detected by immunofluorescence staining. The protein expressions of contractile markers α-smooth muscle actin (α-SMA), CNN1 as well as Notch3 intracellular domain (NICD3) in SMC derived from aortic media and VSC were detected by Western blotting.
RESULTS:
Immunohistochemical staining showed there was a population of c-kit-positive VSC in the adventitia of aortic vessels, and VSC from both normal donors and AD patients had the ability to differentiate into adipocytes and chondrocytes. Compared with normal donor vascular tissue, the expressions of SMC markers α-SMA and CNN1 of tunica media contraction in AD were down-regulated (α-SMA/β-actin: 0.40±0.12 vs. 1.00±0.11, CNN1/β-actin: 0.78±0.07 vs. 1.00±0.14, both P < 0.05), while the protein expression of NICD3 was up-regulated (NICD3/GAPDH: 2.22±0.57 vs. 1.00±0.15, P < 0.05). Compared with Ctrl-VSC-SMC group, the expressions of contractile SMC markers α-SMA and CNN1 were down-regulated in AD-VSC-SMC group (α-SMA/β-actin: 0.35±0.13 vs. 1.00±0.20, CNN1/β-actin: 0.78±0.06 vs. 1.00±0.07, both P < 0.05), the protein expression of NICD3 was up-regulated (NICD3/GAPDH: 22.32±1.22 vs. 1.00±0.06, P < 0.01). Compared with AD-VSC-SMC group, the expressions of contractile SMC markers α-SMA, CNN1 were up-regulated in AD-VSC-SMC+DAPT group (α-SMA/β-actin: 1.70±0.07 vs. 1.00±0.15, CNN1/β-actin: 1.62±0.03 vs. 1.00±0.02, both P < 0.05).
CONCLUSIONS
Dysregulation of VSC differentiation into SMC occurs in AD, while inhibition of Notch3 pathway activation can restore the expression of contractile proteins in VSC-derived SMC in AD.
Humans
;
Actins
;
Platelet Aggregation Inhibitors
;
Signal Transduction
;
Aortic Dissection
;
Cell Differentiation
;
Myocytes, Smooth Muscle
;
Stem Cells
10.Microfluidic Chip and Flow Cytometry for Examination of the Antiplatelet Effect of Ticagrelor.
Xiao-Jing HUANG ; Tian-Cong ZHANG ; Xue-Mei GAO ; Cui HE ; Xuan-Rong HUAN ; Yuan LI
Acta Academiae Medicinae Sinicae 2023;45(2):257-263
Objective To examine the antiplatelet effect of ticagrelor by microfluidic chip and flow cytometry under shear stress in vitro. Methods Microfluidic chip was used to examine the effect of ticagrelor on platelet aggregation at the shear rates of 300/s and 1500/s.We adopted the surface coverage of platelet aggregation to calculate the half inhibition rate of ticagrelor.The inhibitory effect of ticagrelor on ADP-induced platelet aggregation was verified by optical turbidimetry.Microfluidic chip was used to construct an in vitro vascular stenosis model,with which the platelet reactivity under high shear rate was determined.Furthermore,the effect of ticagrelor on the expression of fibrinogen receptor (PAC-1) and P-selectin (CD62P) on platelet membrane activated by high shear rate was analyzed by flow cytometry. Results At the shear rates of 300/s and 1500/s,ticagrelor inhibited platelet aggregation in a concentration-dependent manner,and the inhibition at 300/s was stronger than that at 1500/s (both P<0.001).Ticagrelor at a concentration ≥4 μmol/L almost completely inhibited platelet aggregation.The inhibition of ADP-induced platelet aggregation by ticagrelor was similar to the results under flow conditions and also in a concentration-dependent manner.Ticagrelor inhibited the expression of PAC-1 and CD62P. Conclusion We employed microfluidic chip to analyze platelet aggregation and flow cytometry to detect platelet activation,which can reveal the responses of different patients to ticagrelor.
Humans
;
Ticagrelor/pharmacology*
;
Platelet Aggregation Inhibitors/pharmacology*
;
Flow Cytometry/methods*
;
Microfluidics
;
Platelet Aggregation

Result Analysis
Print
Save
E-mail