1.Criteria for microscopic review following automated hematology analysis.
Chinese Medical Journal 2011;124(7):1119-1119
2.Discussion on Supervision and Sampling of Biochemical Test Kits.
Chinese Journal of Medical Instrumentation 2022;46(2):216-218
As an important part of medical devices, in vitro diagnostic reagents are important means to prevent and diagnose and protect people's health. Supervision and sampling is an important and key supervision method to ensure the in vitro diagnostic reagent products are qualified. This paper summarizes the problems encountered in recent years in vitro diagnostic quantitative testing kit supervision sampling, analyzes the causes of these problems, and puts forward corresponding suggestions, hoping to provide constructive suggestions for supervision sampling.
Hematologic Tests
;
Humans
;
Reagent Kits, Diagnostic
;
Reference Standards
3.Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.
Hye Ryun LEE ; Sue SHIN ; Jong Hyun YOON ; Eun Youn ROH ; Ju Young CHANG
Annals of Laboratory Medicine 2016;36(5):481-488
BACKGROUND: Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. METHODS: A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. RESULTS: As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. CONCLUSIONS: We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.
Breast Feeding
;
Clinical Chemistry Tests/*standards
;
Female
;
Hematologic Tests/*standards
;
Humans
;
Infant
;
Iron/*blood/standards
;
Male
;
Reference Values
;
Republic of Korea
4.Purpose and Criteria for Blood Smear Scan, Blood Smear Examination, and Blood Smear Review.
Gene GULATI ; Jinming SONG ; Alina Dulau FLOREA ; Jerald GONG
Annals of Laboratory Medicine 2013;33(1):1-7
A microscopic examination of an appropriately prepared and well-stained blood smear by a knowledgeable laboratory professional is necessary and clinically useful in a number of circumstances and for a variety of reasons. In this article, an attempt is made to delineate the purpose and criteria for blood smear examination in a variety of circumstances that are encountered in everyday laboratory hematology practice. A blood smear scan serves to at least (a) verify the flagged automated hematology results and (b) determine if a manual differential leukocyte count needs to be performed. Blood smear examination/manual differential leukocyte count with complete blood count (CBC) provides the complete hematologic picture of the case, at least from the morphologic standpoint. Blood smear review with or without interpretation serves to ensure that no clinically significant finding is missed, besides providing diagnosis or diagnostic clue(s), particularly if and when interpreted by a physician.
Blood Cell Count
;
Hematologic Tests/*methods
;
Humans
;
Leukocyte Count
;
Leukocytes/cytology
;
Medical Laboratory Personnel/standards
7.Development of the personalized criteria for microscopic review following four different series of hematology analyzer in a Chinese large scale hospital.
Wei CUI ; Wei WU ; Xin WANG ; Geng WANG ; Ying-Ying HAO ; Yu CHEN ; Dan LUO ; Wei-Ling SHOU ; Shuo ZHANG ; Xue-Fang XIANG ; Yong-Zhen SI ; Qian CHEN ; Hao CAI ; Tan LI ; Han SHEN ; Kun SHANG ; Yong-Qiang ZHANG
Chinese Medical Journal 2010;123(22):3231-3237
BACKGROUNDA generally accepted guideline ("41 rules") published by the International Consensus Group for Hematology Review (ICGHR) can not be suitable for all the laboratories because the facility type, laboratory requirements, sample volume, review rate, turn around time, instrument model and characters etc. are quite different from each other, which may cause a higher workload for microscopy review or lead to false or misleading results. Therefore, we decided to develop the personalized review criteria for 4 series of hematology analyzers in the same hospital, and describe all the implement procedures in detail.
METHODSThe total 1770 blood samples were collected from Peking Union Medical College Hospital. Referring to the suggested criteria by international consensus group for hematology review ("41 rules"), the personalized review criteria for 4 series of hematology analyzers including Siemens Advia 2120, Sysmex XE-2100, Sysmex XT-1800i and Sysmex XS-800i were established and validated by adjusting the rules in order to reduce the false positive rate and keep the false negative acceptable by clinical.
RESULTSUsing the "41 rules", high review rates of 37.94%, 35.56%, 33.44% and 37.94% were got respectively in Siemens Advia 2120, Sysmex XE-2100, Sysmex XT-1800i and Sysmex XS-800i. Three false positive rules mainly were observed in all of 4 analyzers: white blood cell < 3 × 10(9)/L or >30 × 10(9)/L, platelet < 100 × 10(9)/L or > 1000 × 10(9)/L and immature granulocyte. Specialized rules were observed in different series of analyzers, atypical/variant lymphs flag were found mainly in Sysmex XE-2100, Aniso-RBC were found mainly in Sysmex XT-1800i, flag of "immature granulocyte" mainly in Sysmex XS-800i, Micro-RBC, Macro-RBC and Aniso-RBC mainly in Siemens Advia 2120. Rules of immature granulocyte, blast, and NRBC flag would be mainly triggered by hematology malignant tumor. We could not delete these rules due to the risk of false negative of serious disease, other rules were deleted or revised. After continually optimizing to the rules, we finalized the criteria suitable for Siemens Advia 2120, Sysmex XE-2100, Sysmex XT-1800i and Sysmex XS-800i in our laboratory. The false negative rates were 2.94%, 2.86%, 3.10% and 2.78%, the review rates were 31.07%, 30.00%, 30.01% and 30.09%, and there was no hematology malignant tumor missed. Validated by 547 samples, the false negative rates of our optimized rules were 0.37%, 0.55%, 0.55%, and 0.91% respectively.
CONCLUSIONThe criteria can be based on the criteria established by International Consensus Group for Hematology Review but must be optimized according to the different requirements.
Adolescent ; Adult ; Aged ; Aged, 80 and over ; Child ; Child, Preschool ; China ; Female ; Hematologic Tests ; standards ; Hospitals ; standards ; Humans ; Male ; Middle Aged ; Young Adult
8.Usefulness of Frozen-thawed-deglycerolized Red Blood Cells as Quality Control Materials for Red Blood Cell Deformability Test.
Yu Kyung KIM ; Dong Il WON ; Hyun Ok KIM ; Sehyun SHIN ; Jang Soo SUH
The Korean Journal of Laboratory Medicine 2010;30(6):697-701
BACKGROUND: The red blood cell (RBC) deformability test is a useful method for measuring the ability of RBCs to adapt their shape to the flow conditions. Using this test, several investigators have shown the relationship between RBC deformability and numerous clinical conditions. For the quality control (QC) of RBC deformability test, we evaluated whether frozen-thawed-deglycerolized RBCs can be used as QC materials. METHODS: Packed RBCs were frozen with 40% (wt/vol) glycerol and stored at -80degrees C for 3 months. For 10 different frozen RBC panels, RBCs were thawed, deglycerolized and stored at 4degrees C for 4 weeks. Using microfluidic ektacytometer, we measured RBC deformability of the thawed RBCs. The stability of thawed RBCs was tested once a day for 28 days of storage time and was analyzed by simple regression analysis. The precision of the test using thawed RBCs was analyzed for 7 days of storage time by calculation of CV values of intra-assay (10 measurements/assay) and between-day measurements. RESULTS: Frozen-thawed-deglycerolized RBCs were stable for 1 week. Within-run and between-day precisions of the RBC deformability test during 7 days of storage of thawed RBCs were 1.4-2.9%, and 1.9-2.8%, respectively. CONCLUSIONS: Frozen-thawed-deglycerolized RBCs used in RBC deformability test showed satisfactory within-run and between-run precisions and stability for one week after thawing, and may be used as QC materials for this test.
Blood Preservation
;
Cryopreservation
;
Cryoprotective Agents/chemistry/isolation & purification
;
*Erythrocyte Deformability
;
Erythrocytes/immunology/physiology
;
Glycerol/chemistry/isolation & purification
;
Hematologic Tests/standards
;
Humans
;
Quality Control