1.Evaluation of Two ELISA and Two Indirect Hemagglutination Tests for Serodiagnosis of Pulmonary Hydatid Disease.
Fatma Nur ERIS ; Ciler AKISU ; Umit AKSOY
The Korean Journal of Parasitology 2009;47(4):427-429
To establish a definite diagnosis for pulmonary hydatid disease, combination of radiology and serology is useful. In this study, 19 preoperative sera from patients with surgically confirmed pulmonary hydatidosis, 40 sera from patients with other parasitosis and pulmonary diseases, and 20 sera from healthy donors were evaluated using 4 different serological tests, i.e., the commercial ELISA (ELISA-kit) test, the ELISA (ELISA-lab) test prepared in our laboratory, the commercial indirect hemagglutination assay kit (IHA-kit) test, and the IHA test using sensitized sheep red blood cells with tannic acid (IHA-TA). The ELISA-kit was the most sensitive (84.2%) and the most specific test (100.0%). The ELISA-kit also demonstrated the highest positive (100.0%) and negative (95.2%) predictive values. The sensitivity of the ELISA-lab test, that we prepared, was found to be 73.6%, whereas the IHA-kit test and the IHA-TA test were found to be 73.6% and 68.4%, respectively. The specificity of these tests was 96.6%, 98.3%, and 83.3%, respectively. When all 4 tests were assessed together, it was found that the sensitivity had risen to 94.7%. When the ELISA-kit was assessed with the IHA-kit and IHA-TA together, it was found that the sensitivity was 89.5% and 84.2%, respectively. Likewise, the combination of the ELISA-lab and IHA-kit or IHA-TA allowed us to achieve a sensitivity of 84.2% in cases of pulmonary echinococcosis. In conclusion, the diagnosis would be imminent if least 2 tests were applied together.
Echinococcosis, Pulmonary/*diagnosis
;
Enzyme-Linked Immunosorbent Assay/*methods
;
Hemagglutination Tests/*methods
;
Humans
;
Predictive Value of Tests
;
Sensitivity and Specificity
;
Serologic Tests/methods
2.Screening and Identification of Unexpected Red Cell Antibodies by Simultaneous LISS/Coombs and NaCl/Enzyme Gel Methods.
Jeong Hwan SHIN ; Ja Young LEE ; Jae Hyen KIM ; Hye Ran KIM ; Jeong Nyeo LEE
Journal of Korean Medical Science 2009;24(4):632-635
We evaluated the clinical usefulness of simultaneous LISS/Coombs and NaCl/Enzyme testing using the gel method for screening and identification of unexpected antibodies in 15,014 samples. When unexpected antibodies were detected by either screening test, those antibodies were identified using both the LISS/Coombs and the NaCl/Enzyme gel test. The positive screening rates of the LISS/Coombs, NaCl/Enzyme, and combined tests (excluding 25 autoantibody cases) were 0.48%, 1.29%, and 1.39%, respectively. Among the 57 samples positive by both screening methods, the antibodies in 19.3% could be identified only by the NaCl/Enzyme method. Among the 137 samples positive only by NaCl/Enzyme screening, 74.5% showed positive results in antibody identification only by the NaCl/Enzyme test, although 7.3% were also positive in the LISS/Coombs test. The NaCl/Enzyme method thus showed about threefold higher detection rates than the LISS/Coombs method, especially in screening for Rh antibodies, and higher exact identification rates and discriminatory power for identifying mixed antibodies. Addition of the NaCl/Enzyme method to routine laboratory procedures may detect and identify considerable numbers of significant antibodies that might be missed if only the LISS/Coombs method is used.
Antibodies/*analysis/immunology
;
*Coombs' Test
;
Erythrocytes/*immunology
;
Hemagglutination Tests/*methods
;
Humans
;
Isoantibodies/analysis
;
Reagent Kits, Diagnostic
3.Preliminary study on xenotransfusion from porcine red blood cell into Rhesus monkey.
Ying-Xia TAN ; Shou-Ping JI ; Yan-Ping LU ; Cheng-Lin ZHANG ; Li-Li LI ; Feng GONG ; Jin-Guo ZHANG ; Yang-Pei ZHANG
Journal of Experimental Hematology 2006;14(1):150-155
In order to study the possibility of xenotransfusion from porcine red blood cell (pRBC) to primate, the antigens on pRBC surface were modified to make it more compatible to primate sera. Porcine RBCs were subjected to both enzymatic removal of membrane alpha-Gal antigens with recombinant alpha-galactosidase (AGL) and covalent attachment of succinimid propionate-linked methoxypolyethyleneglycol (mPEG-SPA) to camouflage non-alphaGal antigens. The effects of double modifications were determinated by hemagglutination and clinical cross-match testing with rhesus sera. In vivo clearance rates and safety of modified pRBCs were measured after it was transfused into Rhesus monkey with or without immunosuppressant treatment. The validity of pRBC was detected in exsanguine Rhesus monkey model. The results showed that AGL could effectively remove alpha-Gal xenoantigens on pRBC membrane and reduce hemagglutination. The combination of mPEG modification with AGL treatment could significantly increased compatibility between pRBCs and Rhesus monkey sera. Modified pRBCs were detectable in Rhesus monkey blood at 12 hours after transfusion, and their survival time was 40 hours in the immunosuppressant-treated Rhesus monkey. In vivo survival rates of pRBCs were 38% in exsanguine Rhesus monkey at 8 hours after transfusion, and during that time, the hemoglobin and hematocrit of Rhesus monkey were maintained at the same level as before it lost blood. It is concluded that the modified pRBC can be safely transfused into Rhesus monkey and relieve the anemic symptom exsanguine Rhesus monkey. It suggested that pRBC can be hopefully used as a blood substitute for primate and human in the future.
Animals
;
Erythrocyte Transfusion
;
methods
;
Erythrocytes
;
drug effects
;
immunology
;
Hemagglutination Tests
;
Macaca mulatta
;
immunology
;
Polyethylene Glycols
;
pharmacology
;
Swine
;
blood
;
Transplantation, Heterologous
;
methods
;
alpha-Galactosidase
;
pharmacology
4.ABO typing error caused by anti-IgM activated complements.
Li-Hua FANG ; Yu-Ping DU ; Zhao-Hui TANG
Journal of Experimental Hematology 2004;12(4):522-524
In order to determine the appraisal of ABO blood group accurately and ensure the safety of blood transfusion, an investigation was made on the influence of complement activated by antibody in appraising ABO blood group by using hemoagglutination test and direct antiglobulin test. Two samples of ABO blood group were collected from two donors. The results showed that the obverse and reverse patterns did not accord each other in two samples of ABO blood group, and their blood samples were both positive for anti-C(3) and were both negative for anti-IgG. It is concluded that the inconsistency of the obverse and reverse patterns in two samples of ABO blood group were proved to be caused by the complements activated by the antibody against IgM. Blood group O was finally determined for the two samples, and the influences of IgM antibody and complement on ABO blood group were excluded when the test proceeded. This method will be useful to determine ABO blood group accurately.
ABO Blood-Group System
;
immunology
;
Adult
;
Antibodies, Anti-Idiotypic
;
immunology
;
Blood Grouping and Crossmatching
;
methods
;
Complement Activation
;
Female
;
Hemagglutination Tests
;
Humans
;
Male
;
Medical Errors
5.Evaluation of specific antibodies of blood receiver sera to Treponema pallidum by chemiluminescence immunoassay.
Xue-chun WANG ; Ling-zhi CHEN ; Qin YU ; Ai-hua SUN
Chinese Journal of Experimental and Clinical Virology 2013;27(1):70-72
OBJECTIVEThe purpose of this study was to evaluate the diagnostic performance of chemiluminescence immunoassay (CLIA ) , in comparison with that of the following currently used treponemal tests: hemagglutination test (TPHA), and Western Blot (WB).
METHODSFirst, a retrospective study was performed with a panel of 18 494 blood receiver sera by CLIA and TPHA, the specific antibody against T. pallidum in 177 were positive sera by CLIA and/or TPHA, 81 clinical and serologically characterized syphilitic sera, 55 sera obtained from subjects with potentially interfering diseases, and 250 healthy sera were negative were detected by CLIA, TPHA and WB.
RESULTSThe results of WB as the gold standard, the sensitivity of CLIA (98. 4%) was significantly higher than that of TPHA (94. 4%) (Chi2 = 5.76,P <0. 05), the specificity of CLIA (100%) was similar to that of TPHA (99.7%) (Chi2 =1. 0, P >0. 05).
CONCLUSIONCLIA is characterized with higher sensitivity and specificity, It is suitable for screening Syphilis in clinical laboratory.
Antibodies, Bacterial ; blood ; immunology ; Blotting, Western ; methods ; Case-Control Studies ; Hemagglutination Tests ; methods ; Humans ; Immunoassay ; methods ; Luminescence ; Luminescent Measurements ; methods ; Retrospective Studies ; Sensitivity and Specificity ; Syphilis ; blood ; microbiology ; Treponema pallidum ; immunology
6.Evaluation of Automated Architect Syphilis TP as a Diagnostic Laboratory Screening Test for Syphilis.
Jeeyong KIM ; Woo Hyeun KIM ; Chihyun CHO ; Juyeon KIM ; Ga Yeong KIM ; Myung Hyun NAM ; Jang Su KIM ; Sook Young BAE ; Yunjung CHO
The Korean Journal of Laboratory Medicine 2008;28(6):475-482
BACKGROUND: The aim of the study was to establish a new syphilis test algorithm using Architect Syphilis TP (Abbott Japan, Japan: AST), a fully automated treponemal antibody test, as a screening test in a university hospital laboratory. We evaluated performance characteristics of AST in various patient groups. METHODS: A total of 1,357 serum samples obtained from patients at a university hospital from June to August, 2008 were categorized into checkup, preoperative, other diseases, diagnosis (clinically suspected of syphilis), and follow up groups. We compared the results of AST with those of RPR (N=1,276) or Treponema pallidum hemagglutination assay (TPHA, N=81). Samples with discrepant results between RPR or TPHA and AST were retested by fluorescent treponemal antibody absorption test (FTA-ABS) and all patients' clinical records were thoroughly reviewed. RESULTS: The positive rate of AST was significantly higher than that of RPR in preoperative and other diseases groups and was the same as that of RPR in diagnosis group. There were no significant differences in check up and follow up groups. The results of AST showed 97.4% (1,243/1,276) and 97.5% (79/81) concordance rates with those of RPR and TPHA, respectively. Among 26 RPR-AST discrepant and FTA-ABS confirmed cases, there were 20 RPR false-negatives, 4 RPR false-positives, 1 AST false-negative, and 1 AST false-positive. CONCLUSIONS: Based on the results and literature review, we established a new syphilis test algorithm using AST as a screening test, which would be helpful for detection of more syphilis patients including latent infections.
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Algorithms
;
Autoanalysis
;
Child
;
Child, Preschool
;
False Positive Reactions
;
Female
;
Fluorescent Treponemal Antibody-Absorption Test/methods
;
Hemagglutination Tests/methods
;
Humans
;
Male
;
Middle Aged
;
Reagent Kits, Diagnostic
;
Sensitivity and Specificity
;
Syphilis/*diagnosis
;
Syphilis Serodiagnosis/*methods
7.Development and evaluation of indirect ELISA for the detection of antibodies against Japanese encephalitis virus in swine.
Dong Kun YANG ; Byoung Han KIM ; Seong In LIM ; Jun Hun KWON ; Kyung Woo LEE ; Cheong Up CHOI ; Chang Hee KWEON
Journal of Veterinary Science 2006;7(3):271-275
The Japanese encephalitis virus (JEV) is one of causative agents of reproductive failure in pregnant sows. An indirect enzyme-linked immunosorbent assay (I-ELISA) was examined for its potential use in the rapid monitoring of the JEV, and the results were compared with those from the hemagglutination inhibition (HI) and serum neutralization (SN) tests. The comparative analysis showed that the results of I-ELISA showed a significant correlation with the conventional HI (r = 0.867) and SN tests (r = 0.804), respectively. When the I-ELISA results were compared with the traditional diagnostic assays, the sensitivity of the I-ELISA was 94.3% with the HI test and 93.7% with the SN test, respectively. The specificity was found to be 81.4% and 80.0% with the HI and SN tests, respectively. To determine the applicability of I-ELISA in the field, the serum samples from 720 pigs were collected from 4 regions in Korea between July and August 2004. The results indicated that 21.7% of screened pigs were seropositive for the JEV. The seropositive rates of JEV in the 4 provinces were 12.6% in Gyeonggi, 45.0% in Gyeongnam, 16.7% in Jeonbuk, and 12.2% in Jeju. The I-ELISA methodology developed in this study was shown to have considerable sensitivity and specificity through a comparison with HI and the SN tests. Therefore, it might be one of convenient methods for screening a large number of samples in various fields.
Animals
;
Antibodies, Viral/blood
;
Antigens, Viral/immunology
;
Encephalitis Virus, Japanese/immunology/*isolation&purification
;
Encephalitis, Japanese/blood/immunology/*veterinary/virology
;
Enzyme-Linked Immunosorbent Assay/methods/*veterinary
;
Female
;
Hemagglutination Inhibition Tests/veterinary
;
Korea
;
Neutralization Tests/veterinary
;
Swine
;
Swine Diseases/blood/immunology/*virology
8.Granulocyte Antibodies in Korean Neonates with Neutropenia.
Tae Hee HAN ; Myoung Jae CHEY ; Kyou Sup HAN
Journal of Korean Medical Science 2006;21(4):627-632
Neonatal alloimmune neutropenia (NAN) is a disease that can cause severe and prolonged neutropenia in neonates. However, no report is available on the incidence of granulocyte antibody in neonates, the target antigen of this antibody, and the estimated incidence of NAN in Korea. Among a total of 856 neonates admitted to a neonatal intensive care unit (NICU) over a five year period, a total of 105 neonates with neutropenia were enrolled in this study. Positive reactions were observed in the sera of six neonates (5.7%, 6/105) by mixed passive hemagglutination assay (MPHA). To confirm the presence of NAN, MPHA and granulocyte antigen typing (HNA-1a, -1b, -2a, -4a, and -5a) were performed on neonatal and maternal blood. To differentiate granulocyte antibody and HLA antibody, MPHA was also performed using HLA antibody adsorbed serum. We confirmed three cases (2.9%, 3/105) of NAN among neonates with neutropenia in which granulocyte antibody specificities (two anti-HNA-1b and one anti-HNA-1a) and fetomaternal granulocyte antigen mismatches were identified. In this study, the estimated incidence of NAN was 0.35% (3/856) among neonates admitted to NICUs in Korea.
Polymerase Chain Reaction/methods
;
Neutropenia/blood/diagnosis/*immunology
;
Korea
;
Isoantigens/genetics/immunology
;
Isoantibodies/*immunology
;
Intensive Care Units, Neonatal/statistics & numerical data
;
Infant, Newborn
;
Humans
;
Hemagglutination Tests
;
HLA Antigens/immunology
;
Granulocytes/*immunology
;
Genotype
;
Antibody Specificity/immunology
9.Preparation and diagnostic utility of a hemagglutination inhibition test antigen derived from the baculovirus-expressed hemagglutinin-neuraminidase protein gene of Newcastle disease virus.
Kang Seuk CHOI ; Soo Jeong KYE ; Woo Jin JEON ; Mi Ja PARK ; Saeromi KIM ; Hee Jung SEUL ; Jun Hun KWON
Journal of Veterinary Science 2013;14(3):291-297
A recombinant hemagglutinin-neuraminidase (rHN) protein from Newcastle disease virus (NDV) with hemagglutination (HA) activity was expressed in Spodoptera frugiperda cells using a baculovirus expression system. The rHN protein extracted from infected cells was used as an antigen in a hemagglutination inhibition (HI) test for the detection and titration of NDV-specific antibodies present in chicken sera. The rHN antigen produced high HA titers of 2(13) per 25 microL, which were similar to those of the NDV antigen produced using chicken eggs, and it remained stable without significant loss of the HA activity for at least 12 weeks at 4degrees C. The rHN-based HI assay specifically detected NDV antibodies, but not the sera of other avian pathogens, with a specificity and sensitivity of 100% and 98.0%, respectively, in known positive and negative chicken sera (n = 430). Compared with an NDV-based HI assay, the rHN-based HI assay had a relative sensitivity and specificity of 96.1% and 95.5%, respectively, when applied to field chicken sera. The HI titers of the rHN-based HI assay were highly correlated with those in an NDV-based HI assay (r = 0.927). Overall, these results indicate that rHN protein provides a useful alternative to NDV antigen in HI assays.
Animals
;
Antibodies, Viral/*blood
;
Antigens, Viral/*diagnostic use/genetics/metabolism
;
Baculoviridae/genetics
;
Chickens
;
HN Protein/*diagnostic use/genetics/metabolism
;
Hemagglutination Inhibition Tests/*methods/veterinary
;
Newcastle Disease/*diagnosis/immunology/virology
;
Newcastle disease virus/genetics/*immunology/metabolism
;
Poultry Diseases/*diagnosis/immunology/virology
;
Recombinant Proteins/diagnostic use/genetics/metabolism
;
Sf9 Cells
;
Spodoptera
10.Expression, purification, and characterization of an anti-human RBC ScFv-HIV gp160 fusion protein for hemagglutination-based rapid detection of antibodies to HIV in whole blood.
Yan HU ; Jian-yang YANG ; Lei ZHU ; Jun HOU ; Hong-hui SHEN ; Pan-yong MAO
Chinese Journal of Experimental and Clinical Virology 2007;21(1):76-78
OBJECTIVETo construct and express anti-human RBC and HIVgp160 fusion protein for rapid detection of antibody to HIV.
METHODSThe gene of the anti human RBC ScFv and HIV antigen were constructed together into expression vector. The fusion protein was expressed in E. coli.
RESULTSThe fusion protein was proved to be able to bind both anti-RBC and HIVgp160. It could cause agglutination of human RBC when HIVgp160 was present.
CONCLUSIONThe fusion protein has the potential in rapid detection of HIV.
Antibodies, Monoclonal ; immunology ; isolation & purification ; Autoantibodies ; immunology ; isolation & purification ; Cloning, Molecular ; Enzyme-Linked Immunosorbent Assay ; Erythrocytes ; immunology ; Gene Expression ; Genetic Vectors ; genetics ; HIV Antibodies ; blood ; immunology ; HIV Envelope Protein gp160 ; genetics ; immunology ; metabolism ; HIV Seropositivity ; blood ; Hemagglutination Tests ; methods ; Humans ; Recombinant Fusion Proteins ; genetics ; immunology ; metabolism