1.A COMPARATIVE STUDY ON THE FIT IN PROSTHESES USING PREMADE GOLD CYLINDER AND PLASTIC CYLINDER.
Seon Hee JUNG ; Jang Seon MA ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 1999;37(6):825-834
Recently, various implant cylinders were supplied, especially received gold cylinders, cast cylinders produced from premade gold and plastic cylinders and plastic cylinders. This study measured and compared precise fit produced when using conventional gold and plastic cylinders. The comparative fit of lapped and non-lapped castings made from plastic pattern was examined. The implant/abutment interface fit was evaluated by scanning electron microscopy(SEM) for each of four cylinders. The following results were obtained: 1. The case of plastic cylinder showed 9.67+/-1.50micrometer gap Steri-Oss fixture was connected. 2. The case oflapped casting made from plastic cylinder showed 3.01+/-2.81micrometer gap when Steri-Oss fixture was connected. 3. The case of gold/plastic cylinder showed 9.80+/-1.68micrometer gap when Steri-Oss fixture was connected. 4. The case of gold cylinder showed 5.47+/-2.43micrometer gap when Steri-Oss fixture was connected. 5. In case of each cylinder which was connected with Steri-Oss fixture, the size of gap was showed less in the order of the case of gold/plastic cylinder, the case of plastic cylinder, the case of gold cylinder and the case of lapped casting made from plastic cylinder. As results of this study, the use of premade gold cylinder offers an advantage over plastic patterns in precise fit. When plastic patterns are used, polishing of implant cylinder components should provide precise fit.
Plastics*
;
Prostheses and Implants*
2.Lipoma of the Heart: An Autopsy case report.
Min Hee JUNG ; Suk Hee LEE ; Sang Han LEE ; Jong Min CHAE ; Jung Sik KWAK
Korean Journal of Pathology 1996;30(8):746-748
Lipomas of the heart are benign neoplasms and have rarely been described. Due to the fact that they normally cause no symptoms, diagnosis is often purely accidental. Because of the rarity of these tumors, it seems worthwhile to present an example studied at autopsy. It was associated with the sudden death of a 15-year-old boy. The tumor arose from the wall of the left ventricle and occupied the pericardial cavity, measuring 13x7x6 cm in size. The tumor was whitish-yellow, translucent, and soft. Microscopically, the tumor was composed of mature adipose tissue which extended between muscle fibers. This current case, the giant cardiac lipoma is believed to produce disturbances of the conduction system and distrubances of cardiac filling.
3.Sarcoma-like Mural Nodule in Ovarian Mucinous Cystadenocarcinoma: A case report.
Suk Hee LEE ; Min Hee JUNG ; Byung Yuk LEE ; Jong Min CHAE
Korean Journal of Pathology 1996;30(9):854-857
We describe an ovarian mucinous cystadenocarcinoma with a sarcoma-like mural nodule. In the literature, rare cases of ovarian mucinous tumors have been described which contain foci of undifferentiated carcinoma, sarcoma, and sarcoma-like nodules. The distinction between these lesions is important because of poorer prognosis of true sarcoma and anaplastic carcinoma than sarcoma-like mural nodules. This case shows different results of immunohistochemical stain for anaplastic carcinoma.
4.Abrasion of abutment screw coated with TiN.
Seok Won JUNG ; Mee Kyoung SON ; Chae Heon CHUNG ; Hee Jung KIM
The Journal of Advanced Prosthodontics 2009;1(2):102-106
STATEMENT OF PROBLEM: Screw loosening has been a common complication and still reported frequently. PURPOSE: The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS: Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS: TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION: Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.
Collodion
;
Friction
;
Joints
;
Tin
;
Titanium
;
Weight Loss
5.The effects of adriamycin on twitch force and membrane potential in an isolated Guinea-pig papillary muscle.
Chan Uhng JOO ; Pyung Han HWANG ; Jung Soo KIM ; Hee Cheol YU ; Soo Wan CHAE
Journal of the Korean Pediatric Society 1991;34(5):677-681
No abstract available.
Doxorubicin*
;
Membrane Potentials*
;
Membranes*
;
Papillary Muscles*
6.Sinking and fit of abutment of locking taper implant system.
Seung Jin MOON ; Hee Jung KIM ; Mee Kyoung SON ; Chae Heon CHUNG
The Journal of Advanced Prosthodontics 2009;1(2):97-101
STATEMENT OF PROBLEM: Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE: In this study, Bicon(R) Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS: 10 Bicon(R) implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS: It was evident, that the amount of abutment sinking in Bicon(R) Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 +/- 0.09 mm. CONCLUSION: Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.
Bite Force
;
Fingers
;
Friction
;
Retention (Psychology)
7.Photocatalytic antifungal activity against candida albicans by TiO2 coated acrylic resin denture base.
Ji Yeon YANG ; Hee Jung KIM ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 2006;44(3):284-294
Statement of problem. Proliferation of Candida albicans is primarily within the plaque on the fitting surface of the denture rather than on the inflamed mucosa. Consequently, the treatment of the denture is equally important as treatment of the tissue. Cleansing and disinfection should be efficiently carried-out as the organisms can penetrate into the voids of the acrylic resin and grow in them, from which they can continue to infect and reinfect bearing tissues. Purpose. The purpose of this study was to evaluate the applicability of photocatalytic reaction to eliminate Candida albicans from acrylic resin denture base, and to investigate the antifungal effect with various UVA illumination time. Materials and Methods. The specimens were cured by the conventional method following the manufacturer's instruction using thermal polymerized denture base resin (Vertex RS; Dentimex, Netherlands). TiO2 photocatalyst sol(LT), which is able to be coated at normal temperature, was made from the Ti-alkoxide progenitor. The XRD patterns, TEM images and nitrogen absorption ability of the TiO2 photocatalyst sol(LT) were compared with the commercial TiO2 photocatalyst P-25. The experimental specimens were coated with the mixture of the TiO2 photocatalyst sol(LT) and binder material (silane) using dip-coater, and uncoated resin plates were used as the control group. Crystallinity of TiO2 of the specimen was tested by the XRD. Size, shape and chemical compositions were also analyzed using the FE-SEM/EDS. The angle and methylene blue degradation efficiency were measured for evaluating the photocatalytic activity of the TiO2 film. Finally, the antifungal activity of the specimen was tested. Candida albicans KCTC 7629(1 ml, initial concentration 105cells/ml) were applied to the experiment and control group specimens and subsequently two UVA light source with 10W, 353 nm peak emission were illuminated to the specimens from 15cm above. The extracted 2 microliter of sample was plated on nutrient agar plate (BactoTM Brain Heart Infusion; BD, USA) with 10 minute intervals for 120 minute, respectively. It was incubated for 24 hours at 37 degree C and the colony forming units (CFUs) were then counted. Results. Compared the characteristics of LT photocatalyst with commercial P-25 photocatalyst, LT were shown higher activity than P-25. The LT coated experimental specimen surface had anatase crystal form, less than 20 nm of particle size and wide specific surface area. To evaluate the photocatalytic activity of specimens, methylene blue degradation reaction were used and about 5% of degradation rate were measured after 2 hours. The average contact angle was less than 20.indicating that the LT photocatalyst had hydrophilicity. In the antifungal activity test for Candida albicans, 0% survival rate were measured within 30 minute after irradiation of UVA light. Conclusion. From the results reported above, it is concluded that the UVA-LT photocatalytic reaction have an antifungal effect on the denture surface Candida albicans, and so that could be applicable to the clinical use as a cleaning method.
Absorption
;
Agar
;
Brain
;
Candida albicans*
;
Candida*
;
Crystallins
;
Denture Bases*
;
Dentures*
;
Disinfection
;
Heart
;
Hydrophobic and Hydrophilic Interactions
;
Lighting
;
Methylene Blue
;
Mucous Membrane
;
Nitrogen
;
Particle Size
;
Polymers
;
Stem Cells
;
Survival Rate
8.The effects of passive smoking on children's respiratory illness.
Mi Jung LEE ; Soo Ann CHAE ; Kon Hee LEE ; Hae Sun YOON
Pediatric Allergy and Respiratory Disease 1993;3(1):14-22
No abstract available.
Tobacco Smoke Pollution*
9.Evaluation of Elecsys 2010 Electrochemiluminescent Immunoassay System.
Jung Ee LEE ; Hee Soon CHO ; Jin Young MUN ; Chae Hoon LEE ; Kyung Dong KIM
Korean Journal of Clinical Pathology 1997;17(6):1029-1037
BACKGROUND: Elecsys 2010 immunoassay system is based on the electrochemiluminescence immunoassay using a ruthenium (II) tris (bipyridyl) label. Since it was the first time to use the system in our laboratory, we would like to evaluate the analytical performances (precision, linearity and recovery rate) and correlation with radioimmunoassay (RIA) and microparticle enzyme immunoassay (MEIA) methods. METHODS: We used precicontrol tumor marker (TM1, TM2) for alpha-fetoprotein (AFP), prostatic specific antigen (PSA) and carcinoembryonic antigen (CEA), Precicontrol universal (Ul, U2) for triiodothyronine (T3) and thyroxine (T4), Precicontrol-TSH for thyrotropin (TSH) and pooled serum for the evaluation of precision and recovery rate. Patients' sera were used for the linearity and comparison study. RESULTS: The coefficients of variatron of Imprecision study were below; 4.0%, 8.7% and 10.2%, respectively in the within-run, within-day and between-day analysis. The recovery rates were 100.5%, 96.1% and 102.5%, respectively in T4, TSH, and AFP. The linearity were y=1.02x-0.182(r=0.99) for T4, y=1.01x+0.12 (r=0.99) for TSH and y=1.01x+0.54(r=1.00) for AFP. T3, T4, TSH, CEA and PSA results showed good correlation with RIA (r>0.90), but AFP showed r=0.88. Also, AFP, CEA and PSA results showed excellent correlation with AxSYM (r>0.99). CONCLUSION: Elecsys 2010 immunoassay system showed excellent precision, recovery rate, clinically acceptable linearity and good correlation with the results obtained by RIA and MEIA methods.
alpha-Fetoproteins
;
Carcinoembryonic Antigen
;
Immunoassay*
;
Immunoenzyme Techniques
;
Radioimmunoassay
;
Ruthenium
;
Thyrotropin
;
Thyroxine
;
Triiodothyronine
10.The Tissue Expression of HBsAg and HBcAg in Hepatocellular Carcinoma and Peritumoral Liver.
Jee Young HAN ; Woo Hee JUNG ; Chae Yoon CHON ; Chan Il PARK
Korean Journal of Pathology 1993;27(4):371-378
To evaluate the tissue expression rate and pattenr of HBsAg and HBcAg in tumors and peritumoral livers, an immunohistochemical study was undertaken on 47 surgically resected hepatocellular carcinomas(HCCs). The results are as follows. 1. Patient's sera were positive for HBsAg in 40 cases(85.1%). In the remaining 7 cases, the tumor and peritumoral liver expressed neither HBcAg nor HbSaG, suggesting that they were caused by other etiologies than hepatitis B virus. 2. The peritumoral liver had HBsAg and HBcAg in 95.0% and 27.5% among the 40 cases, respectively. But the tumor expressed HBsAg in 50.0% and HBcAg in none. 3. The expression of HBsAg within the tumor and both HBsAg and HBcAg in the peritumoral liver tended to be more frequent in the pretreated cases before surgery. 4. Edmondson-Steiner grade IV tumors revealed a lower expression rate of HBsAg than the low grade tumors(p<0.05). Incases with cirrhosis at peritumoral tissues, HBcAg was less frequently found than in those without cirrhosis. The majority of tissue HBsAg and HBcAg was represented as groups of positive cells. These results suggest that, during the development and progression of HCCs, the HBcAg containing cells are repeatedly removed and the HBcAg negative cells are selected, because cellular expression of HBcAg is the target of host immune response.
Carcinoma, Hepatocellular