1.Investigation of hemostatic disorders in patients with congenital heart diseases undergoing open heart surgery at Hue Central Hospital
Sang Si Dong ; Minh Ngoc Nguyen ; Hoa Thi Thuy Phan ; Thuan Thi Nguyen ; Dung Thi Tran ; Hanh Phuoc Huynh
Journal of Medical Research 2007;51(4):55-62
Background: Open heart surgery with cardiopulmonary bypass (CPB) causes haemostatic abnormalities which result in postoperative excessive bleeding. Objectives: To investigate haemostatic disorders before - after CPB and postoperative bleeding. Subjects and methods: Sixty congenital cardiac patients with and without cyanosis were recruited consecutively. Hematology and coagulation tests were done 1 day before operation, 15 minutes after protamine administration, 2 and 6 hours after the operation in the intensive care unit (lCU). Mediastinal chest tube drainage (MCTO) was measured for the first 6h in the ICU. Results: Significant differences between 2 groups could be found for red blood cells, hemoglobin, hematocrit, fibrinogen, D-dimer, fibrinogen degradation products (FOP), von Kaulla and platelet aggregation to epinephrine before operation (p < 0.05). There were not significant differences in platelets, PT, APTT, platelet aggregation to adenosine diphosphate (AOP) in the acyanotic and cyanotic patients (p > 0.05). Most hematology parameters were decreased significantly and hemostasis measurements were prolonged after operation in both groups (p < 0.05). There was also the significant difference in MCTO between 2 groups (p < 0.05). Conclusion: Coagulation, hemostasis and fibrinolysis disorders; thrombocytopenia and acquired transient platelet dysfunction may be responsible for bleeding complications after CBP \r\n', u'\r\n', u'
Heart Defects
;
Congenital/ pathology
;
epidemiology
;
Hemostatic Disorders/ pathology
;
diagnosis
3.Pulmonary Arterial Hypertension with Congenital Heart Diseases.
Journal of the Korean Pediatric Cardiology Society 2006;10(3):239-252
Pulmonary arterial hypertension is a significant complication of congenital heart disease, which carries a recognized risk of morbidity and mortality. There have been remarkable advances in the field of pulmonary arterial hypertension over the past several decades. At the third world symposium on pulmonary arterial hypertension held in Venice, Italy, 2003, congenital cardiac shunts were classified in the same group as idiopathic pulmonary hypertension. This article discusses the recent advances in understanding the pathology, pathobiology, diagnosis, and treatment of pulmonary arterial hypertension associated pediatric congenital heart disease.
Diagnosis
;
Heart Defects, Congenital
;
Heart Diseases*
;
Heart*
;
Hypertension*
;
Hypertension, Pulmonary
;
Italy
;
Mortality
;
Pathology
;
Pediatrics
4.Pulmonary Arterial Hypertension with Congenital Heart Diseases.
Journal of the Korean Pediatric Cardiology Society 2006;10(3):239-252
Pulmonary arterial hypertension is a significant complication of congenital heart disease, which carries a recognized risk of morbidity and mortality. There have been remarkable advances in the field of pulmonary arterial hypertension over the past several decades. At the third world symposium on pulmonary arterial hypertension held in Venice, Italy, 2003, congenital cardiac shunts were classified in the same group as idiopathic pulmonary hypertension. This article discusses the recent advances in understanding the pathology, pathobiology, diagnosis, and treatment of pulmonary arterial hypertension associated pediatric congenital heart disease.
Diagnosis
;
Heart Defects, Congenital
;
Heart Diseases*
;
Heart*
;
Hypertension*
;
Hypertension, Pulmonary
;
Italy
;
Mortality
;
Pathology
;
Pediatrics
5.MR Imaging of Congenital Heart Disease.
Dong Hun KIM ; Sang Wan RYU ; Yun Woo CHANG ; Ji Youn JANG
Journal of the Korean Radiological Society 2004;51(5):563-572
MRI is useful for demonstrating the anatomy of various congenital cardiac lesions and plays an important role in the diagnosis of congenital cardiac lesions. Its large field of view and unlimited imaging planes enable the depiction of complex lesions, the complicated three-dimensional relations of the cardiac chambers and anomalies of the central pulmonary arteries, the systemic and pulmonary veins, and aorta. We describe the normal MR anatomy and MR imaging findings of a variety of congenital pathologies of the heart, in order to provide a better understanding and facilitate the interpretation of the MR features of various congenital heart diseases.
Aorta
;
Diagnosis
;
Heart
;
Heart Defects, Congenital*
;
Heart Diseases
;
Magnetic Resonance Imaging*
;
Pathology
;
Pulmonary Artery
;
Pulmonary Veins
6.Cardiovascular cast model fabrication and casting effectiveness evaluation in fetus with severe congenital heart disease or normal heart.
Yu WANG ; Hai-yan CAO ; Ming-xing XIE ; Lin HE ; Wei HAN ; Liu HONG ; Yuan PENG ; Yun-fei HU ; Ben-cai SONG ; Jing WANG ; Bin WANG ; Cheng DENG
Journal of Huazhong University of Science and Technology (Medical Sciences) 2016;36(2):259-264
To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease (control group) and 18 specimens with severe congenital heart disease (case group) from induced abortions were enrolled in this study from March 2013 to June 2015 in our hospital. Cast models were prepared by injecting casting material into vascular lumen to demonstrate real geometries of fetal cardiovascular system. Casting effectiveness was analyzed in terms of local anatomic structures and different anatomical levels (including overall level, atrioventricular and great vascular system, left-sided and right-sided heart), as well as different trimesters of pregnancy. In our study, all specimens were successfully casted. Casting effectiveness analysis of local anatomic structures showed a mean score from 1.90±1.45 to 3.60±0.52, without significant differences between case and control groups in most local anatomic structures except left ventricle, which had a higher score in control group (P=0.027). Inter-group comparison of casting effectiveness in different anatomical levels showed no significant differences between the two groups. Intra-group comparison also revealed undifferentiated casting effectiveness between atrioventricular and great vascular system, or left-sided and right-sided heart in corresponding group. Third-trimester group had a significantly higher perfusion score in great vascular system than second-trimester group (P=0.046), while the other anatomical levels displayed no such difference. Vascular corrosion technique can be successfully used in fabrication of fetal cardiovascular cast model. It is also a reliable method to demonstrate three-dimensional anatomy of severe congenital heart disease and normal heart in fetus.
Corrosion Casting
;
methods
;
Fetal Heart
;
pathology
;
Heart Defects, Congenital
;
pathology
;
Humans
;
Models, Anatomic
7.Author Reply.
Yonsei Medical Journal 2005;46(2):310-312
No abstract available.
Echocardiography
;
Heart Defects, Congenital/*diagnosis/pathology
;
Heart Ventricles
;
Humans
;
Magnetic Resonance Imaging
;
Tomography, X-Ray Computed
8.Multidisciplinary Diagnostic Approach for Left Ventricular Hypertrabeculation/Noncompaction.
Josef FINSTERER ; Claudia STOLLBERGER ; Wolfgang KOPSA
Yonsei Medical Journal 2005;46(2):309-310
No abstract available.
Echocardiography
;
Heart Defects, Congenital/*diagnosis/pathology
;
Heart Ventricles
;
Humans
;
Magnetic Resonance Imaging
;
Tomography, X-Ray Computed
9.Congenital left ventricular diverticulum, a rare chest fluoroscopy finding: a case report.
Zhi-Wei WANG ; Hong-Bing WU ; Zhi-Fu MAO ; Xiao-Ping HU
Chinese Medical Journal 2011;124(5):783-786
Congenital left ventricular diverticulum is a very rare cardiac abnormality and it is not completely understood about its etiology, clinical manifestation, diagnosis, treatment and prognosis. This article presents a case of large congenital diverticulum of the left ventricle. The clinical manifestation included paroxysmal supraventricular tachycardia. The diagnosis was made by chest fluoroscopy observation and confirmed by 64-slice CT-angiography. The arrhythmia alleviated instead of antiarrhythmic drugs but by radiofrequency catheter ablation. Due to the rapid growth of the diverticulum, the patient underwent surgical resection finally. Owing to the fatal risks, clinicians should improve the understanding of this disease by deeply studying more cases, in order to standardize the treatment.
Adult
;
Diverticulum
;
diagnosis
;
Female
;
Fluoroscopy
;
methods
;
Heart Defects, Congenital
;
diagnosis
;
Heart Ventricles
;
pathology
;
Humans
;
Young Adult
10.Prevalence of Congenital Heart Disease among Infants from 2012 to 2014 in Langfang, China.
Peng-Fei SUN ; Gui-Chun DING ; Min-Yu ZHANG ; Sheng-Nan HE ; Yu GAO ; Jian-Hua WANG
Chinese Medical Journal 2017;130(9):1069-1073
BACKGROUNDCongenital heart disease (CHD) is the most common congenital malformations with high mortality and morbidity. The prevalence of CHD reported previously ranged from 4 per 1000 live births to 50 per 1000 live births. In this cross-sectional study, we aimed to document the prevalence of CHD in Langfang district of Hebei Province, China by analyzing data collected by hospitals located in 11 the counties of the district, as supported by a public health campaign.
METHODSA total of 67,718 consecutive 3-month-old infants were included from July 19, 2012 to July 18, 2014. Structural abnormalities were diagnosed based on echocardiography findings, including two-dimensional and color Doppler echocardiography results.
RESULTSOf the 67,718 infants, 1554 were found to have cardiac structural abnormalities. The total prevalence of CHD was 22.9 per 1000 live births, a value significantly higher than the previously reported prevalence of 8 cases per 1000 live births. The top five most common cardiac abnormalities were as follows: atrial septal defect (ASD, 605 cases, 8.93‰); ventricular septal defect (550 cases, 8.12‰); patent ductus arteriosus (228 cases, 3.37‰); pulmonary stenosis (66 cases, 0.97‰); and tetralogy of Fallot (32 cases, 0.47‰). The CHD prevalence differed by gender in this study ( χ2 = 23.498,P < 0.001), and the majority of ASD cases were females. Regional differences in prevalence were also found ( χ2 = 24.602,P < 0.001); a higher prevalence was found in urban areas (32.2 cases per 1000 live births) than in rural areas (21.1 cases per 1000 live births). There was a significant difference in the prevalence of CHD in preterm versus full-term infants ( χ2 = 133.443,P < 0.001). Prevalence of CHD in infants of maternal aged 35 years or over was significantly higher ( χ2 = 86.917,P < 0.001).
CONCLUSIONSThe prevalence of CHD in Langfang district was within the range reported using echocardiography. Echocardiography can be used to early diagnose the CHD.
China ; Cross-Sectional Studies ; Ductus Arteriosus ; pathology ; Echocardiography ; Female ; Heart Defects, Congenital ; pathology ; Heart Septal Defects, Atrial ; pathology ; Humans ; Male ; Prevalence ; Pulmonary Valve Stenosis ; pathology ; Tetralogy of Fallot ; pathology