1.Trends in Mortality from Hemorrhagic Stroke in Korea from 2012 to 2020
Kwang-Chun CHO ; Hasung KIM ; Sang Hyun SUH
Neurointervention 2022;17(2):87-92
Purpose:
To analyze trends in mortality rates from hemorrhagic stroke (HS) according to HS subtypes, using nationwide data from January 2012 to December 2020.
Materials and Methods:
We used data from the National Health Claims Database provided by the National Health Insurance Service for 2012–2020 using the International Classification of Disease. The age-adjusted mortality rates of HS, which included subarachnoid hemorrhage (SAH) and intracerebral hemorrhage (ICH), were calculated, and additional analyses were conducted according to age and sex.
Results:
The age-adjusted mortality rates for HS, SAH, and ICH decreased substantially in both sexes between 2012 and 2020. During the study period, mortality rates for HS decreased from 8.87 deaths per 100,000 inhabitants to 6.27 deaths per 100,000 inhabitants. Regarding SAH, mortality rates decreased from 3.72 deaths per 100,000 inhabitants to 2.57 deaths per 100,000 inhabitants. Concerning ICH, mortality rates decreased from 6.91 deaths per 100,000 inhabitants to 4.75 deaths per 100,000 inhabitants. The average annual percentage change for HS, SAH, and ICH was –0.04, –0.04, and –0.05, respectively. Mortality rates from HS, SAH, and ICH in both sexes decreased from 2012 to 2020 in all age groups.
Conclusion
In Korea, the age-adjusted mortality rate of HS, SAH, and ICH demonstrated a declining trend in both sexes and across all age groups. These results may aid in the design and improvement of preventive strategies.
3.Comparison of IRIS Iq200, UF-1000i, and Cobas u701 Module Automated Urine Sediment Analyzers
Hyunji CHOI ; Dahae YANG ; Sun Ja KWON ; Poo Reum KANG ; Hasung PARK ; Teayun KIM ; Hyunyong HWANG
Laboratory Medicine Online 2020;10(4):283-294
Background:
We sought to compare the performance of three commercially available automated urine sediment analyzers that represent the current urine sediment analysis technology.
Methods:
A total of 232 patient samples were analyzed using manual microscopy and three automated analyzers: IRIS Iq200 (Beckman Coulter, USA), UF-1000i (Sysmex, Japan), and Cobas u701 (Roche, Switzerland). We analyzed precision, linearity, carry-over, concordance rate, and agreement between the three analyzers and manual microscopy.
Results:
The repeatability and within-laboratory precision showed results similar to those of previous studies. All analyzers showed excellent linearity. The carry-over rates were within 1%. The correlation coefficient (r) between the three analyzers and manual microscopy was good. Regarding red blood cell (RBC), the UF-1000i showed a better concordance rate (90.52%) with manual microscopy than the other two analyzers and the agreement was substantial for UF-1000i (κ=0.63) and IRIS Iq200 (κ=0.61). Regarding white blood cell (WBC), Cobas u701 showed the best concordance rate (96.55%) and the agreement was moderate for IRIS Iq200 (κ=0.57) and Cobas u701 (κ=0.56), and fair for UF-1000i (κ=0.47). Regarding epithelial cell (EPI), IRIS Iq200 showed the highest concordance rate (99.2%) and the agreement was moderate for IRIS Iq200 (κ=0.59) and Cobas u701 (κ=0.54), and fair for UF-1000i (κ=0.40).
Conclusions
IRIS Iq200 offered the best agreement with manual microscopy for WBC and EPI count, while UF-1000i showed a better agreement for RBC count. The agreement is insufficient for fully replacing the manual microscopy.
4.Comparison of IRIS Iq200, UF-1000i, and Cobas u701 Module Automated Urine Sediment Analyzers
Hyunji CHOI ; Dahae YANG ; Sun Ja KWON ; Poo Reum KANG ; Hasung PARK ; Teayun KIM ; Hyunyong HWANG
Laboratory Medicine Online 2020;10(4):283-294
Background:
We sought to compare the performance of three commercially available automated urine sediment analyzers that represent the current urine sediment analysis technology.
Methods:
A total of 232 patient samples were analyzed using manual microscopy and three automated analyzers: IRIS Iq200 (Beckman Coulter, USA), UF-1000i (Sysmex, Japan), and Cobas u701 (Roche, Switzerland). We analyzed precision, linearity, carry-over, concordance rate, and agreement between the three analyzers and manual microscopy.
Results:
The repeatability and within-laboratory precision showed results similar to those of previous studies. All analyzers showed excellent linearity. The carry-over rates were within 1%. The correlation coefficient (r) between the three analyzers and manual microscopy was good. Regarding red blood cell (RBC), the UF-1000i showed a better concordance rate (90.52%) with manual microscopy than the other two analyzers and the agreement was substantial for UF-1000i (κ=0.63) and IRIS Iq200 (κ=0.61). Regarding white blood cell (WBC), Cobas u701 showed the best concordance rate (96.55%) and the agreement was moderate for IRIS Iq200 (κ=0.57) and Cobas u701 (κ=0.56), and fair for UF-1000i (κ=0.47). Regarding epithelial cell (EPI), IRIS Iq200 showed the highest concordance rate (99.2%) and the agreement was moderate for IRIS Iq200 (κ=0.59) and Cobas u701 (κ=0.54), and fair for UF-1000i (κ=0.40).
Conclusions
IRIS Iq200 offered the best agreement with manual microscopy for WBC and EPI count, while UF-1000i showed a better agreement for RBC count. The agreement is insufficient for fully replacing the manual microscopy.
5.Nationwide Trends of Gatekeeper to Invasive Coronary Angiography in Suspected Coronary Artery Disease
Min Jae CHA ; William D KIM ; Hoyoun WON ; Jaeeun JOO ; Hasung KIM ; In-Cheol KIM ; Jin Young KIM ; Seonhwa LEE ; Iksung CHO
Korean Circulation Journal 2022;52(11):814-825
Background and Objectives:
Real-world trends in the utility and type of gatekeeping studies in invasive coronary angiography (ICA) requires further investigation.
Methods:
We identified outpatients who underwent noninvasive cardiac tests or directly ICA for suspected coronary artery disease (CAD) from the nationwide Korea Health Insurance Review and Assessment Service-National Patient Sample database between 2012 and 2018.
Results:
Among 71,401 patients, the percentage of patients who were evaluated for suspected CAD was 34.7% for treadmill test (TMT), 4.2% for single-photon emission computed tomography (SPECT), 24.2% for coronary computed tomography angiography (CCTA), 1.6% for multiple gatekeepers, and 32.3% for directly ICA without noninvasive studies. The proportion of CCTA as a gatekeeper showed linear increase, (18.6% in 2012 and 28.8% in 2018; p<0.001), while those of TMT, SPECT, and direct ICA have decreased (p<0.001, p=0.03, and p<0.001, respectively). The overall incidence of downstream ICA after gatekeeper was 13.8% (6,662/48,346), and SPECT showed higher ICA rate in pairwise comparison with TMT and CCTA (p<0.001). Patients who performed gatekeepers before ICA showed higher rate of subsequent PCI (34.7% vs. 32.3%; p<0.001) and CABG (3.5% vs. 1.0%; p<0.001), compared to those who directly underwent ICA, and CCTA was associated with higher revascularization rate after ICA in pairwise comparison with TMT and SPECT (p<0.001).
Conclusions
Nationwide database demonstrated that CCTA is utilized increasingly as a gatekeeper for ICA and is associated with high revascularization rate after ICA in outpatients with suspected CAD.