1.MRI features of intracranial primitive neuroectodermal tumors in adults: comparing with histopathological findings.
Haojun, SHI ; Xiangquan, KONG ; Haibo, XU ; Liying XU ; Dingxi, LIU
Journal of Huazhong University of Science and Technology (Medical Sciences) 2004;24(1):99-102
The MRI appearances of 7 adult patients with pathologically proven intracranial primitive neuroectodermal tumors (PNET) were retrospectively analyzed. The MRI features were compared with findings in pathology and surgery. In this group, the tumor masses were most commonly found in the semisphere of cerebrum and in the vermis of cerebellum. They were relatively large and 4 were in lobulated shape. All of them had well-defined margins. MR images showed the tumors to be mildly or obviously hypointense on T1-weighted images and hyperintense on T2-weighted images. Most masses had heterogeneous appearances with some cystic and necrotic areas. Intratumoral haemorrhage and focal calcification were occasionally seen. Mostly, there was no or only mild surrounding edema. Marked inhomogeneous contrast enhancement on MRI was seen in 6 cases except one. Two patients with multiple intracranial metastases were revealed on MR images. In this series, there was good correlation between MRI features and findings in pathology and surgery. These results showed that certain MRI features might suggest the diagnosis of intracranial PNET in adults. MRI is an effective technique to detect these tumors and is helpful to treatment planning and follow-up.
Brain Neoplasms/*diagnosis
;
Brain Neoplasms/*pathology
;
*Magnetic Resonance Imaging
;
Neuroectodermal Tumors, Primitive/*diagnosis
;
Neuroectodermal Tumors, Primitive/*pathology
;
Retrospective Studies
2.Use of dentritic cells pulsed with HLA-A2-restricted MAGE-A1 peptide to generate cytotoxic T lymphocytes against malignant glioma.
Haojun, SHI ; Xiaobing, JIANG ; Peng, FU ; Yi, ZHOU ; Xiaoling, LU
Journal of Huazhong University of Science and Technology (Medical Sciences) 2010;30(5):678-82
This study developed a novel approach of targeting malignant glioma with pMAGE-A1(278-286)-specific cytotoxic T lymphocytes (CTLs) induced from the peripheral blood mononuclear cells of healthy donors by multiple stimulations with human leukocyte antigen (HLA)-A2-restricted pMAGE-A1(278-286) peptide-pulsed dentritic cells. Cytotoxic assays were performed by the colorimetric CytoTox 96 assay to analyze cytotoxic activity of the induced CTLs against various target cells. The induced CTLs showed approximately 45% specific lysis against T2pMAGE-A1(278-286) (pMAGE-A1(278-286) peptide pulsed T2 cells) and U251 (HLA-A2(+), MAGE-A1(+)) at an effector:target ratio of 40:1, and approximately 5% cytolysis against T2pHIV, A172 (HLA-A2(-), MAGE-A1(+)), K562 and T2 cells without being pulsed with peptide at any effector:target ratio. The specific killing activity of the induced CTLs against T2pMAGE-A1(278-286) and U251 was much more obvious than in any other control group (P<0.05). The cytotoxic activity against the T2pMAGE-A1(278-286) and U251 was significantly eliminated by anti-HLA class I mAb W6/32. These results suggest that pMAGE-A1(278-286) epitope may serve as a surrogate tumor antigen target of specific immunotherapy for treating HLA-A2 patients with malignant glioma.
3.Added diagnostic value of CT attenuation correction for spinal lesions in SPECT bone imaging
Haojun YU ; Yiqiu ZHANG ; Beilei LI ; Liang CAI ; Shuguang CHEN ; Hongcheng SHI
Chinese Journal of Nuclear Medicine and Molecular Imaging 2016;36(3):250-254
Objective To investigate the added value of CTAC for improving image quality and diagnostic efficiency of bone imaging in SPECT/CT.Methods Seventy-five patients (47 males,28 females,(56.6± 12.8) years) with abnormal uptake in planar whole-body bone scintigraphy underwent SPECT/CTfor differentiation of malignant from benign spinal lesions.NAC and CTAC SPECT images were classified based on 5-point scale (5:excellent,4:good,3:adequate,2:suboptimal,1:inadequate).The diagnostic confidence for both NAC and CTAC SPECT images were classified based on 4-point scale (4:definite,3:certain,2:equivocal,1:uninterpretable).The pathological results after surgery were used as gold standard to evaluate the added diagnostic value of CTAC for spinal lesions.Wilcoxon-signed rank sum test was used for data analysis.Results CTAC improved the image quality in 37.3% (28/75) of patients,and downgraded in 2.7% (2/75) of patients.The remaining 45 patients were unchanged (60.0%,45/75).SPECT with CTAC could significantly improve the image quality (z=-4.747,P<0.001),but the overall diagnostic confidence was not increased (z=-1.000,P>0.05).Conclusion CTAC can improve the image quality of spinal SPECT,especially useful in imaging with poorer quality,but it has no significant incremental value in diagnostic confidence.
4.Diffusion-weighted single-shot echo planar MR imaging of normal human prostate using different b values.
Haojun, SHI ; Xiangquan, KONG ; Gansheng, FENG ; Haibo, XU ; Dingxi, LIU ; Qun, YU
Journal of Huazhong University of Science and Technology (Medical Sciences) 2008;28(6):737-40
This study examined the effect of different b values on diffusion-weighted MR imaging (DWI) of human prostate by using single-shot spin echo echo planar imaging (SE-EPI) sequences, observed the normal appearances and measured apparent diffusion coefficient (ADC) values in anatomical regions of normal prostate. Twenty-four healthy volunteers (mean age: 32 y) were studied by using a 1.5T system with a phased array surface multicoil. Two kinds of single-shot SE-EPI sequence were used to perform DWI in the prostate in volunteers, with five b values being 0, 30, 300, 500 to 1000 s/mm(2). The image quality with different imaging parameters was analyzed and the ADC values in anatomical regions of normal prostate were measured. DWI of prostate was successfully obtained in all volunteers. The images were of good quality, without artifacts containing pixels within the prostate. The contrast was good between the different anatomical regions of the prostatic gland, i.e., the peripheral zone (PZ), which exhibited higher signal intensity, and the central gland (CG). Signal intensity contrast was related to the magnitude of b values. The ADC values in PZ and CG were (1.27+/-0.22)x10(-3) mm(2)/s and (1.01+/-0.17)x10(-3) mm(2)/s, respectively. The ADC values were found to be significantly higher in PZ than in CG (P<0.05, paired t-test). Significant differences were found between the slice-selecting component and both the read-out and phase-encoding components of the ADC values. It is concluded that SE-EPI is a suitable DWI sequence for human prostate. The contrast between PZ and CG is good when b values are low, while the diffusion and ADC values are accurate when b values are high. ADC values are higher in PZ than in CG in normal prostate. Diffusional anisotropy is present in normal prostatic tissue.
Magnetic Resonance Imaging/*methods
;
Prostate/*anatomy & histology
5.Medicine packaging improvement based on PAP shelter hospital requirements
Bo YANG ; Haojun FAN ; Lei SHI ; Zhiheng WU ; Jing BU ; Yuhua HU ; Shike HOU
Chinese Medical Equipment Journal 2017;38(5):29-31,35
Objecive To explore the medicine packaging improvement based on PAP shelter hospital requirements to fulfill emergency medicine support,Methods The medicine support during rescue was discussed from the aspects of considerations in medicine plan,requirement for emergency medicine,special medicine purchasing and medicine support,and some countermeasures were put forward for improving medicine packaging.Results Its suggested that the optimization of medicine packaging be performed with considerations on medicine property,package capacity,convenience,transport and environmental suitability.Conclusion Emergency medicine support is of importance for disaster medical rescue,and medicine packaging improvement based on PAP shelter hospital requirements contributes to enhancing the efficiency during disaster rescue.
6.MRI features of intracranial primitive neuroectodermal tumors in adults: comparing with histopathological findings.
Haojun SHI ; Xiangquan KONG ; Haibo XU ; Liying XU ; Dingxi LIU
Journal of Huazhong University of Science and Technology (Medical Sciences) 2004;24(1):99-102
The MRI appearances of 7 adult patients with pathologically proven intracranial primitive neuroectodermal tumors (PNET) were retrospectively analyzed. The MRI features were compared with findings in pathology and surgery. In this group, the tumor masses were most commonly found in the semisphere of cerebrum and in the vermis of cerebellum. They were relatively large and 4 were in lobulated shape. All of them had well-defined margins. MR images showed the tumors to be mildly or obviously hypointense on T1-weighted images and hyperintense on T2-weighted images. Most masses had heterogeneous appearances with some cystic and necrotic areas. Intratumoral haemorrhage and focal calcification were occasionally seen. Mostly, there was no or only mild surrounding edema. Marked inhomogeneous contrast enhancement on MRI was seen in 6 cases except one. Two patients with multiple intracranial metastases were revealed on MR images. In this series, there was good correlation between MRI features and findings in pathology and surgery. These results showed that certain MRI features might suggest the diagnosis of intracranial PNET in adults. MRI is an effective technique to detect these tumors and is helpful to treatment planning and follow-up.
Adult
;
Brain Neoplasms
;
diagnosis
;
pathology
;
Female
;
Humans
;
Magnetic Resonance Imaging
;
Male
;
Neuroectodermal Tumors, Primitive
;
diagnosis
;
pathology
;
Retrospective Studies
7.Clinical application of 18F-FDG PET/CT imaging in diagnosis of focal organizing pneumonia
Jun ZHOU ; Wujian MAO ; Yushen GU ; Haojun YU ; Shuguang CHEN ; Hongcheng SHI
Chinese Journal of Nuclear Medicine and Molecular Imaging 2020;40(8):464-469
Objective:To explore the imaging features of 18F-fluorodeoxyglucose (FDG) PET/CT (high-resolution CT, HRCT) imaging in focal organizing pneumonia (FOP). Methods:Patients with solid nodular FOP ( n=45; 33 males, 12 females, age (58±9) years) and early peripheral non-mucinous solid lung adenocarcinoma ( n=47; 21 males, 26 females, age (63±10) years) confirmed by postsurgical pathology between May 2012 and December 2018 in Zhongshan Hospital, Fudan University were retrospectively analyzed. All patients underwent 18F-FDG PET/CT (HRCT) imaging followed by surgery within 3 weeks. The imaging findings and characteristics of the lesions were recorded. Differences of the maximum standardized uptake value (SUV max) and maximum diameter between FOP and adenocarcinoma were analyzed by Mann-Whitney U test or t′ test. Spearman correlation or Pearson correlation analysis was performed to analyze the relation between SUV max and maximum diameter. Binary logistic regression analysis was performed to identify the predictive factors for FOP. Finally, the receiver operating characteristic (ROC) curve analysis was used for evaluation of diagnostic efficiency. Results:The SUV max of FOP was lower than that of lung adenocarcinoma (3.1(1.7, 4.9) vs 6.5(3.8, 9.3); z=-4.598, P<0.01), and the maximum diameter of FOP was smaller than that of lung adenocarcinoma ((18.0±6.3) mm vs (21.8±4.3) mm; t′=-3.424, P<0.01). The SUV max was positively correlated with the maximum diameter in FOP group ( r s=0.509, P<0.01), while the SUV max of lung adenocarcinoma was not correlated with the lesion size ( r=0.076, P>0.05). HRCT of the PET/CT system showed the fusiform shape were more common in FOP ( χ2=9.549, P<0.05). Multivariate regression analysis identified that SUV max≤7.1, diameter≤18.3 mm, and fusiform shape were independent factors to predict FOP, with odds ratio ( OR) of 10.585, 4.674, 9.073, respectively (all P<0.05). ROC curve analysis showed that the area under the curve (AUC) of SUV max≤7.1 combined with diameter≤18.3 mm and fusiform nodule was 0.860, and the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 97.8%(44/45), 70.2%(33/47), 75.9%(44/58), 97.1%(33/34), and 83.7%(77/92), respectively. Conclusion:SUV max≤ 7.1 combined with maximum diameter≤ 18.3 mm and fusiform shape may predict solid nodular FOP.
8.Diffusion-weighted Single-shot Echo Planar MR Imaging of Normal Human Prostate Using Different b Values
SHI HAOJUN ; KONG XIANGQUAN ; FENG GANSHENG ; XU HAIBO ; LIU DINGXI ; YU QUN
Journal of Huazhong University of Science and Technology (Medical Sciences) 2008;28(6):737-740
This study examined the effect of different b values on diffusion-weighted MR imaging (DWI) of human prostate by using single-shot spin echo echo planar imaging (SE-EP1) sequences,observed the normal appearances and measured apparent diffusion coefficient (ADC) values in anatomical regions of normal prostate. Twenty-four healthy volunteers (mean age: 32 y) were studied by using a 1.ST system with a phased array surface multicoil. Two kinds of single-shot SE-EPI sequence were used to perform DWI in the prostate in volunteers, with five b values being 0, 30, 300, 500 to 1000 s/mm2. The image quality with different imaging parameters was analyzed and the ADC values in anatomical regions of normal prostate were measured. DWI of prostate was successfully obtained in all volunteers. The images were of good quality, without artifacts containing pixels within the prostate. The contrast was good between the different anatomical regions of the prostatic gland, i.e.,the peripheral zone (PZ), which exhibited higher signal intensity, and the central gland (CG). Signal intensity contrast was related to the magnitude of b values. The ADC values in PZ and CG were (1.27±0.22)× 10-3 mm2/s and (1.01±0.17)× 10-3 mm2/s, respectively. The ADC values were found to he significantly higher in PZ than in CG (P<0.05, paired t-test). Significant differences were found between the slice-selecting component and both the read-out and phase-encoding components of the ADC values. It is concluded that SE-EPI is a suitable DWI sequence for human prostate. The contrast between PZ and CG is good when b values are low, while the diffusion and ADC values are accurate when b values are high. ADC values are higher in PZ than in CG in normal prostate. Diffusional anisotropy is present in normal prostatic tissue.
9.Use of Dentritic Cells Pulsed with HLA-A2-restricted MAGE-A1 Peptide to Generate Cytotoxic T Lymphocytes against Malignant Glioma
SHI HAOJUN ; JIANG XIAOBING ; FU PENG ; ZHOU YI ; LU XIAOLING
Journal of Huazhong University of Science and Technology (Medical Sciences) 2010;30(5):678-682
This study developed a novel approach of targeting malignant glioma with pMAGE-A1278-286-specific cytotoxic T lymphocytes (CTLs) induced from the peripheral blood mononuclear cells of healthy donors by multiple stimulations with human leukocyte antigen (HLA)-A2-restricted pMAGE-A1278-286 peptide-pulsed dentritic cells. Cytotoxic assays were performed by the colorimetric CytoTox 96 assay to analyze cytotoxic activity of the induced CTLs against various target cells. The induced CTLs showed approximately 45% specific lysis against T2pMAGE-A 1278-286 (pMAGE-A 1278-286 peptide pulsed T2 cells) and U251 (HLA-A2+, MAGE-A 1 +)at an effector:target ratio of 40:1, and approximately 5% cytolysis against T2pHIV, A172 (HLA-A2,MAGE-AI+), K562 and T2 cells without being pulsed with peptide at any effector:target ratio. The specific killing activity of the induced CTLs against T2pMAGE-A1278-286 and U251 was much more obvious than in any other control group (P<0.05). The cytotoxic activity against the T2pMAGE-A1278-286 and U251 was significantly eliminated by anti-HLA class I mAb W6/32.These results suggest that pMAGE-A1278-286 epitope may serve as a surrogate tumor antigen target of specific immunotherapy for treating HLA-A2 patients with malignant glioma.
10.Comparison of the image quality between total-body PET/CT with 1 min acquisition and conventional PET/CT: a self-control study
Runjun YANG ; Xueqi CHEN ; Haojun YU ; Pengcheng HU ; Hongcheng SHI
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(1):12-15
Objective:To investigate whether the image quality of total-body PET/CT (TB PET/CT) with 1 min acquisition can meet the clinical diagnostic requirements.Methods:From May 2019 to September 2021, a total of 90 malignant tumor patients (60 males, 30 females, age 31-86 years) with primary lesions confirmed by pathological diagnosis in Zhongshan Hospital, Fudan University were respectively analyzed. All patients underwent conventional PET/CT (C PET/CT) scan with conventional clinical acquisition and TB PET/CT scan with 1 min acquisition after injecting 18F-FDG in random order. Paired t test or Wilcoxon signed rank test was used to analyze the image quality of these two scans. Results:SUV max of primary lesions in TB PET/CT group was significantly higher than that in C PET/CT group (15.9(7.9, 24.6) vs 12.5(5.8, 16.6); z=8.14, P<0.001), so were signal-to-noise ratio (SNR) of the blood pool, liver, muscles (9.3±3.0, 11.4(9.5, 14.2), 8.3(7.3, 10.1) vs 6.2±1.7, 9.4(7.7, 11.8), 6.0(4.9, 7.1)), tumor-to-blood pool ratio (TBR) (9.3(4.3, 14.8) vs 8.5(4.3, 11.1)), tumor-to-liver ratio (TLR) (6.7(3.0, 10.4) vs 6.1(2.9, 7.7)), tumor-to-muscle ratio (TMR) (23.2(11.5, 38.0) vs 18.3(9.6, 26.6); t=9.36, z values: 4.44-7.40, all P<0.001). Conclusion:The image quality of TB PET/CT scan with 1 min acquisition can meet the diagnostic requirements, and is better than the C PET/CT image quality with conventional clinical acquisition.