1.Design of Electrocardiosignal Filter
Chinese Medical Equipment Journal 1989;0(04):-
Objective There are many interferences such as power interference, electrode polarization interference, myoelectricity interference, baseline drift, apparatus buzz and so on in electrocardiosignal acquisition system. It is very difficult to effectively remove these interferences in the process of actual measurement. Methods Power harmonic interference, electrode polarization interference and myoelectricity interference were removed by low-pass filter. Baseline drift was removed by high-pass filter. Power basic frequency interference was removed by 50 Hz trap filter. Results These three design proposals had such advantages as good effect, rapid speed and easy realization. Conclusion They can be well applied in ECG monitor with embedded CPU and real time character. Besides, they can also be used in medical apparatus measuring other biological electric signals and industrial observation and control system.
2.Objectification on Metabolomics of Different Traditional Chinese Medicine Syndromes in Patients with Coronary Heart Disease and Angina Pectoris
World Science and Technology-Modernization of Traditional Chinese Medicine 2017;19(5):797-803
This study was aimed to investigate potential biomarkers in different traditional Chinese medicine (TCM) syndromes of angina pectoris of coronary heart disease (CHD) by using metabolomic technology,and to explore the objective law of different TCM syndromes of CHD.Endogenous metabolites in serum and urine from the healthy group,and patients with DHD angina pectoris patients of the syndrome of Qi deficiency and blood stasis,as well as the syndrome of Qi deficiency,blood stasis and phlegm turbidity were detected by the liquid chromatography-mass spectrometry (LC-MS).Metabolic profiles were analyzed by the principal component analysis (PCA) and the orthogonal partial least squares discriminant analysis (OPLS-DA).The results showed that in PCA,the healthy group,Qi deficiency and blood stasis group,as well as the Qi deficiency,blood stasis and phlegm turbidity group can be obviously distinguished.Potential biomarkers in the Qi deficiency and blood stasis syndrome contained aspartyl methionine and cysteine sulfinic acid.Potential biomarkers in the Qi deficiency,blood stasis and phlegm turbidity syndrome contained hippuric acid,amino glucose,fructosamine and triglyceride.The objective performance of Qi deficiency syndrome was the absence of biotin,lysyl tyrosine,phosphatidylglycerol and glycocholic acid.It was concluded that through the new metabolomic technology,different endogenous metabolites in the syndrome of Qi deficiency and blood stasis,as well as the syndrome of Qi deficiency,blood stasis and phlegm turbidity of patients with DHD angina pectoris were detected.It provided ideas for the clinical practice of prevention,diagnosis and treatment of different TCM syndromes.
3.Research on Residues of 16 Phthalate Ester Plasticizers in Oral Liquid Preparations
Hao ZHONG ; Dezhou GE ; Hao LIU ; Zulei DENG
China Pharmacist 2014;(4):556-560
Objective:To establish a GC-MS method for the simultaneous determination of 16 phthalate ester plasticizers in oral liquid preparations, compare the purification effect of liquid preparations by liquid-liquid extraction and solid phase extraction and opti-mize the operating parameters to determine the optimal experimental conditions. Methods:The samples were operated by liquid-liquid extraction and solid phase extraction, respectively. Selective ion monitor ( SIM) was adopt, phthalate esters were identified by the rela-tive abundance of major characteristic ions and the content was determined by an external standard method. Results:When the samples were operated by liquid-liquid extraction, the interference was strong with many impurity peaks. Therefore, the solid phase extraction was adopted for the sample pretreatment. GC-MS was used to detect the residues of 16 phthalate ester plasticizers in oral liquid prepara-tions. The detection limit was 0. 02μg·g-1 ,while the calibration curve showed good linearity within the range of 0. 25-8. 0μg·ml-1 with the correlation coefficient between 0. 990 7 and 0. 999 8. The average recoveries were 76. 0%-95. 4%. The relative standard devi-ations were between 2. 3% and 9. 6%(n=6). Conclusion: Pretreated by solid phase extraction, the residues of 16 phthalate ester plasticizers in oral liquid preparations can be detected by GC-MS with the properties of simple, fast, precise and sensitive, and it is suitable for the determination of phthalate esters in oral liquid preparations.
4.Long serial analysis of gene expression in the yeast phase of Candida albicans
Cunjian ZHOU ; Fei HAO ; Yongjian DENG
Medical Journal of Chinese People's Liberation Army 2001;0(10):-
Objective To construct a library of long serial analysis of gene expression (LongSAGE) and investigate the characteristics of gene expression in the yeast phase of C. albicans. Methods A LongSAGE library was constructed with long serial analysis of gene expression (LongSAGE). Results A total of 17 773 tags, representing specific 7 333 transcripts, were extracted from 1 000 sequence files in the yeast phase of C. albicans. Tags matching single gene accounted for 16.65%, tags matching multiple genes accounted for 6.59%, tags for hypothetical protein accounted for 16.27%, tags for genome and cosmid accounted for 1.64%, and novel tags accounted for 58.86%. Eleven tags in 33 tags whose expression frequencies exceeded 35 may be new expression sequences. Conclusion LongSAGE is not only a powerful method in investigating the gene expression profiling, allowing the analysis of the expression of thousands of transcripts in a quantitative manner without prior sequence information, but also in finding new genes.
5.Expression of SLAM gene in CD4~+ and CD8~+ T cells from SLE patients
Yi YOU ; Fei HAO ; Yongjian DENG
Journal of Third Military Medical University 1983;0(03):-
Objective To explore the expression of SLAM gene in the CD4+ and CD8+ T cells from SLE patients.Method The CD4+ and CD8+ T cells from peripheral blood of 20 SLE patients and 10 healthy blood donors were separated using magnetic cell sorting system(MACS).We detected the expression of SLAM mRNA in CD4+ and CD8+ T cells by RT-PCR.Results The CD4+ and CD8+ T cells from SLE patients showed significantly higher SLAM expression than those from healthy blood donors.Conclusion The SLAM signal pathway may play an important role in contributing to the abnormal activation of T cells in SLE patients.
6.Detection and significance of CD4 and CD8 subsets of T lymphocytes in the peripheral blood of systemic lupus erythematosus patients by magnetic activated cell sorting
Yi YOU ; Fei HAO ; Yongjian DENG
Journal of Third Military Medical University 2003;0(07):-
Objective To investigate the abnormality of CD4 and CD8 subsets of T lymphocytes in the peripheral blood of systemic lupus erythematosus patients. Methods The CD4 + and CD8 + T lymphocytes from 20 SLE patients and 10 healthy controls were separated using magnetic activated cell sorting (MACS). Results The numbers of CD4 + T cells in the peripheral blood and CD4 +/CD8 + ratio of SLE patients were significantly lower than those in healthy volunteers(CD4,P=0.001;CD4/CD8 ratio,P=0.046). Conclusion There exist abnormalities in the CD4 and CD8 subsets of T lymphocytes in the peripheral blood of SLE,especially the decreased numbers of CD4 + T cells.
7.Changes in ultrastructure of fresh leaves of Ginkgo biloba after microwave-assisted extraction
Jinyu HAO ; Wei HAN ; Xiu DENG ;
Chinese Traditional and Herbal Drugs 1994;0(08):-
Object To study the ultrastructure destruction of plants in the process of microwave assisted solvent extracion and its mechanism.Methods Cell structures of fresh leaves of Ginkgo biloba L. were observed by transmission electron microscpoe.Results The cell structure changed when the leaves were under microwave radiation or soaked by solvents or heated, such as plasmoysis, destruction of cell organellaes, disappearance of starch grain and so on, while the cell wall was not broken both in microwave assisted solvent extraction and in traditional heating extraction.Conclusion Microwave radiation could lead to the relaxation of the cell structures, but not be enough to make the cell wall broken.
8.Preparation of Diclofenac Sodium Microemulsion with Poloxamer 188 as Coemulsifier
Hao WANG ; Jijin GU ; Yingjie DENG
China Pharmacy 2007;0(25):-
OBJECTIVE: To investigate the effect of poloxamer 188 as co-emulsifier on the pharmaceutical property of emulsion.METHODS: Diclofenac sodium was used as model drug and poloxamer 188 as co-emulsifier,the emulsion was prepared by high pressure homogen-colostrum pH adjusting method,with its entrapment efficiency,particle size,?-electric potential etc determined.RESULTS: The emulsion which was added with poloxamer 188 showed decreased entrapment efficiency and ?-electric potential but increased particle size as comapred with the one without poloxamer 188.CONCLUSION: The pharmaceutical property of emulsion wouldn't necessarily be enhanced by adding poloxamer 188 as co-emulsifier.
9.Content Determination of Testosterone Propionate in Testosterone Propionate Paints by HPLC
Daiquan DENG ; Bimin FENG ; Hao ZHANG
China Pharmacy 1991;0(03):-
OBJECTIVE:To establish a HPLC method for the content determination of testosterone propionate in testosterone propionate paints.METHODS:The assaying was conducted on a Kromasil C 18 column with methanol-water solution(80∶20)as mobile phase,the detection wavelength was254nm and the flow rate was1.0ml/min.RESULTS:The linear concentration range of the testosterone propionate was100~400mg/ml(r=0.9997)with average recovery rate at98.5%(RSD=0.55%).CONCLUSION:The method is simple,accurate and reproducible,and it can be used for the quality control of testosterone propionate paints.
10.Determination of Ochratoxin A in Chinese Herbs by HPLC-MS/MS
China Pharmacist 2014;(10):1652-1654,1655
Objective:To determine ochratoxin A ( OTA ) in Chinese herbs by high performance liquid chromatography-tandem mass spectrometry method ( HPLC-MS/MS) . Methods: The samples were extracted by 80% methanol water solution and purified by immunoaffinity column. The chromatographic separation was carried out on a C18 column, the mobile phase was methanol-acetonitrile-0. 01 mol·L-1 ammonium acetate, and then OTA was detected by MS/MS in an ESI(-)-MRM mode. Results:The limit of detection was 0. 1 μg·kg-1 , the average recoveries ranged from 84. 8% to 91. 2%, and the relative standard deviations ( RSD) ranged from 3. 6% to 8. 1%(n=9). Conclusion:The method is accurate,sensitive and simple, and suitable for the determination of ochratoxin A in Chinese herbs.