1.Changes of exhaled nitric oxide and peripheral blood eosinophils in children with asthma.
Chun-Long GE ; Chuang-Li HAO ; Ning-Bo TANG ; Yue-Mei SUN ; Li-Ping LIU ; Ning HE
Chinese Journal of Contemporary Pediatrics 2009;11(12):986-988
OBJECTIVEThis study examined the levels of exhaled nitric oxide (eNO) and peripheral blood eosinophils (EOS) as well as the correlation between the two markers in children with bronchial asthma (AS),AS complicated by allergic rhinitis (AS/AR) and chronic cough variant asthma (CVA), in order to explore the value of eNOS detection in children with AS.
METHODSThe eNO level was measured using light-emitting electrochemical photometry in 12 children with AS, 29 children with AS/AR and 10 children with CVA. Peripheral blood EOS was counted by blood cell counter (Coulter JT). Forced expiratory volume in one second (FEV1) was assessed by lung function measurement. Thirty children without atopic disease and acute respiratory infection as well as without a family history of atopic diseasea served as the control group.
RESULTSThe levels of eNO and blood EOS in the AS, the AS/AR and the CVA groups were significantly higher than those in the control group (p<0.01). The AS/AR group showed increased levels of eNO (50.3 + or - 6.7 ppb) and EOS (5.9 + or -4.2 x 109 ) compared with the AS (30.5 + or - 8.8 ppb and 4.2 + or - 3.2 x 109 respectively) and the CVA groups (26.0 + or - 3.2 ppb and 3.7 + or - 6.9 x 109 respectively) (p<0.05). There were no significant differences in eNO and EOS levels between the AS and the CVA groups. The eNO level was positively correlated with the EOS level (r=0.51, p<0.05), but not with FEV1 (r=0.144, p>0.05) in the AS group.
CONCLUSIONSNO is highly expressed in children with symptoms of atopy and can reflect the levels of eosinophilic airway inflammation in children with AS.
Adolescent ; Asthma ; blood ; physiopathology ; Breath Tests ; Child ; Child, Preschool ; Eosinophils ; physiology ; Female ; Forced Expiratory Volume ; Humans ; Male ; Nitric Oxide ; metabolism
2.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.
3.Reducing Postoperative Neurological Complications in Uniportal Full-Endoscopic Lumbar Interbody Fusion: Efficacy of the GUARD Technique Combined With Delayed Ligamentum Flavectomy
Hao-Chun CHUANG ; Yu-Chia HSU ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1199-1209
Objective:
Uniportal full-endoscopic transforaminal lumbar interbody fusion (FE-TLIF) carries a unique risk of nerve traction and abrasion injury during cage insertion. This study aims to evaluate the clinical efficacy of the GUARD technique and delayed ligamentum flavectomy in reducing postoperative radicular pain and neurapraxia in patients undergoing uniportal FE-TLIF.
Methods:
A retrospective analysis was conducted on 45 patients with an average age of 53.9±12.4 years who underwent either FE facet-sparing TLIF (FE fs-TLIF) or FE facet-resecting TLIF (FE fr-TLIF). Patients were divided into 2 groups: the sentinel group (21 patients) using traditional sentinel pin techniques, and the GUARD group (24 patients) using the GUARD technique with delayed ligamentum flavectomy. Patient-reported outcomes included the visual analogue scale (VAS) for leg and back pain, and Oswestry Disability Index. Complication rates, including incidental durotomy, postoperative neurapraxia, and hematoma, were also documented.
Results:
Postoperative radicular pain in the legs was significantly reduced at 6 weeks in the GUARD group compared to the sentinel group (VAS: 2.201 vs. 3.267, p=0.021). The incidence of postoperative neurapraxia was markedly lower in the GUARD group (0% vs. 19%, p=0.047). Both groups showed similar improvements in disc height, segmental lordosis, and lumbar lordosis at the 1-year follow-up, with no significant differences in endplate injury or fusion rates.
Conclusion
The GUARD technique and delayed ligamentum flavectomy significantly enhance patient safety by reducing postoperative radicular pain and neurapraxia without incurring additional costs. These techniques are easy to learn and integrate into existing surgical workflows, offering a valuable improvement for surgeons performing FE-TLIF procedures.
4.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.
5.Reducing Postoperative Neurological Complications in Uniportal Full-Endoscopic Lumbar Interbody Fusion: Efficacy of the GUARD Technique Combined With Delayed Ligamentum Flavectomy
Hao-Chun CHUANG ; Yu-Chia HSU ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1199-1209
Objective:
Uniportal full-endoscopic transforaminal lumbar interbody fusion (FE-TLIF) carries a unique risk of nerve traction and abrasion injury during cage insertion. This study aims to evaluate the clinical efficacy of the GUARD technique and delayed ligamentum flavectomy in reducing postoperative radicular pain and neurapraxia in patients undergoing uniportal FE-TLIF.
Methods:
A retrospective analysis was conducted on 45 patients with an average age of 53.9±12.4 years who underwent either FE facet-sparing TLIF (FE fs-TLIF) or FE facet-resecting TLIF (FE fr-TLIF). Patients were divided into 2 groups: the sentinel group (21 patients) using traditional sentinel pin techniques, and the GUARD group (24 patients) using the GUARD technique with delayed ligamentum flavectomy. Patient-reported outcomes included the visual analogue scale (VAS) for leg and back pain, and Oswestry Disability Index. Complication rates, including incidental durotomy, postoperative neurapraxia, and hematoma, were also documented.
Results:
Postoperative radicular pain in the legs was significantly reduced at 6 weeks in the GUARD group compared to the sentinel group (VAS: 2.201 vs. 3.267, p=0.021). The incidence of postoperative neurapraxia was markedly lower in the GUARD group (0% vs. 19%, p=0.047). Both groups showed similar improvements in disc height, segmental lordosis, and lumbar lordosis at the 1-year follow-up, with no significant differences in endplate injury or fusion rates.
Conclusion
The GUARD technique and delayed ligamentum flavectomy significantly enhance patient safety by reducing postoperative radicular pain and neurapraxia without incurring additional costs. These techniques are easy to learn and integrate into existing surgical workflows, offering a valuable improvement for surgeons performing FE-TLIF procedures.
6.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.
7.Reducing Postoperative Neurological Complications in Uniportal Full-Endoscopic Lumbar Interbody Fusion: Efficacy of the GUARD Technique Combined With Delayed Ligamentum Flavectomy
Hao-Chun CHUANG ; Yu-Chia HSU ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1199-1209
Objective:
Uniportal full-endoscopic transforaminal lumbar interbody fusion (FE-TLIF) carries a unique risk of nerve traction and abrasion injury during cage insertion. This study aims to evaluate the clinical efficacy of the GUARD technique and delayed ligamentum flavectomy in reducing postoperative radicular pain and neurapraxia in patients undergoing uniportal FE-TLIF.
Methods:
A retrospective analysis was conducted on 45 patients with an average age of 53.9±12.4 years who underwent either FE facet-sparing TLIF (FE fs-TLIF) or FE facet-resecting TLIF (FE fr-TLIF). Patients were divided into 2 groups: the sentinel group (21 patients) using traditional sentinel pin techniques, and the GUARD group (24 patients) using the GUARD technique with delayed ligamentum flavectomy. Patient-reported outcomes included the visual analogue scale (VAS) for leg and back pain, and Oswestry Disability Index. Complication rates, including incidental durotomy, postoperative neurapraxia, and hematoma, were also documented.
Results:
Postoperative radicular pain in the legs was significantly reduced at 6 weeks in the GUARD group compared to the sentinel group (VAS: 2.201 vs. 3.267, p=0.021). The incidence of postoperative neurapraxia was markedly lower in the GUARD group (0% vs. 19%, p=0.047). Both groups showed similar improvements in disc height, segmental lordosis, and lumbar lordosis at the 1-year follow-up, with no significant differences in endplate injury or fusion rates.
Conclusion
The GUARD technique and delayed ligamentum flavectomy significantly enhance patient safety by reducing postoperative radicular pain and neurapraxia without incurring additional costs. These techniques are easy to learn and integrate into existing surgical workflows, offering a valuable improvement for surgeons performing FE-TLIF procedures.
8.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.
9.Reducing Postoperative Neurological Complications in Uniportal Full-Endoscopic Lumbar Interbody Fusion: Efficacy of the GUARD Technique Combined With Delayed Ligamentum Flavectomy
Hao-Chun CHUANG ; Yu-Chia HSU ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1199-1209
Objective:
Uniportal full-endoscopic transforaminal lumbar interbody fusion (FE-TLIF) carries a unique risk of nerve traction and abrasion injury during cage insertion. This study aims to evaluate the clinical efficacy of the GUARD technique and delayed ligamentum flavectomy in reducing postoperative radicular pain and neurapraxia in patients undergoing uniportal FE-TLIF.
Methods:
A retrospective analysis was conducted on 45 patients with an average age of 53.9±12.4 years who underwent either FE facet-sparing TLIF (FE fs-TLIF) or FE facet-resecting TLIF (FE fr-TLIF). Patients were divided into 2 groups: the sentinel group (21 patients) using traditional sentinel pin techniques, and the GUARD group (24 patients) using the GUARD technique with delayed ligamentum flavectomy. Patient-reported outcomes included the visual analogue scale (VAS) for leg and back pain, and Oswestry Disability Index. Complication rates, including incidental durotomy, postoperative neurapraxia, and hematoma, were also documented.
Results:
Postoperative radicular pain in the legs was significantly reduced at 6 weeks in the GUARD group compared to the sentinel group (VAS: 2.201 vs. 3.267, p=0.021). The incidence of postoperative neurapraxia was markedly lower in the GUARD group (0% vs. 19%, p=0.047). Both groups showed similar improvements in disc height, segmental lordosis, and lumbar lordosis at the 1-year follow-up, with no significant differences in endplate injury or fusion rates.
Conclusion
The GUARD technique and delayed ligamentum flavectomy significantly enhance patient safety by reducing postoperative radicular pain and neurapraxia without incurring additional costs. These techniques are easy to learn and integrate into existing surgical workflows, offering a valuable improvement for surgeons performing FE-TLIF procedures.
10.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.