1.Analysis of Key Factors Affecting Maintenance Cost of Large-Scale Medical Equipment
Hanxue LI ; Wanhai QIAO ; Huahua ZHANG ; Huiru DOU
Chinese Medical Equipment Journal 2004;0(07):-
Objective To explore the key factors which affect maintenance cost of large-scale medical equipment. Methods The basic factors which affect maintenance cost of medical imagining equipment were summarized. The relationships of them are analyzed and then an interpretative structure mode of each factor was set. Additionally, the multiple relationship and controllability between each factor were also analyzed and the judging standard of key factors was set. Results The maintenance policy and mode were the key factors which affect maintenance cost of medical imagining equipment. Conclusion High quality maintenance for equipment condition and scientific optimization of the maintenance policy are necessary to fundamentally reduce the maintenance cost of large-scale medical equipment.
2.Design and application of a medical bed and its bedside angle measuring device
Chinese Critical Care Medicine 2019;31(4):493-494
Patient position management is an important work in clinical treatment. In clinic, it is necessary to adjust the corresponding patient's position according to the characteristics of the patient's condition. The appropriate patient's position plays an important role in treating the disease, alleviating the severity of symptoms and preventing the complications in the critical patients. A medical bedside angle measuring device and medical bed was designed. The measuring device was convenient for the clinicians to read the raised angle in time, improving the working efficiency, and the structure was simple and the operation was convenient. The whole device mainly included panel, unfolding device and medical bed with bed angle measuring device on the panel. There was an angle display area, with the range of display angle was 0°to 75°, which was adjusted to the corresponding angle according to the needs of the patient's condition under usage. The angle corresponding to the horizontal measurement line was the angle of elevating the head of the bed. The newly invented medical bedside angle measuring device and the medical bed could help the clinical medical staff know the patient's position at a glance, raising the bed head accurately, and making it convenient to use. It provided a good solution for clinical application and it was worth to popularize.
3.Exploration of design and practice of disaster medical rescue monitoring system with privacy protection mechanism
Hanxue LIU ; Xiaolin ZHANG ; Yuxiang ZHANG
Chinese Critical Care Medicine 2019;31(2):236-237
Chronic?obstructive?pulmonary?disease?(COPD)?is?a?severe?respiratory?disease?characterized?by?airway?obstruction?with?high?mortality?and?rate?of?recurrence.?Rehabilitation?exercise?can?lessen?the?possibility?of?the?progressive?exacerbation?of?the?patient's?condition,?exerting?an?active?role?in?improving?their?lung?function?and?the?quality?of?the?patients'?life.?Therefore,?we?have?designed?a?lung?function?exercise?bottle,?which?is?capable?of?adjusting?the?pressure?according?to?the?patient's?needs.?It?is?easy?to?operate?and?apply?in?practice.?The?exercise?bottle?is?composed?of?three?components,?including?bottle?body,?threaded?round?cap?and?air?blow?pipe.?The?bottle?body?is?formed?in?rectangle?shape,?and?utilized?to?contain?liquid.?The?filling?opening?is?designed?on?the?top?of?the?bottle.?Outside?of?the?filling?opening,?there?is?a?screw?thread?round?cap,?which?can?adjust?the?pressure?according?to?the?patient's?tolerance,?gradually?increasing?the?training?intensity,and?improving?the?training?effect?thereby.?The?blowpipe?can?be?inserted?into?the?bottle?body?and?the?patient?can?blow?the?air?through?the?tube.?Compared?with?the?traditional?rehabilitation?training,?when?the?newly?invented?lung?function?exercise?bottle?has?been?used?for?rehabilitation?exercise,?the?air?pressure?in?the?bottle?can?be?adjusted,?with?the?advantage?of?wider?range?of?application,?lower?cost?and?more?convenient.?It?provides?a?good?solution?for?clinical?and?home-based?rehabilitation?and?is?worth?of?popularizing.
4.Application Value of Quantitative Analysis of Cell DNA in Cervical Lesion Screening
Zhe ZHANG ; Lingting KONG ; Hanxue SUN ; Xiaohan LI ; Qingjie L(U)
Journal of China Medical University 2017;46(11):1013-1018
Objective To determine the application value of quantitative detection of DNA in cervical lesion screening.Methods Retrospective analysis of 82 518 cases of cervical lesions was carried out.The sensitivity,specificity,positive predictive value (PPV),and negative predictive value (NPV) of DNA quantification and ThinPrep cytology test (TCT) for the diagnosis of cervical lesions were compared with the results of biopsy.The accuracy of the two methods was evaluated by applying the receiver operating characteristic curve.Results The sensitivity of DNA quantification,TCT,and combined diagnosis was 77.37%,70.97%,and 90.24%,respectively,and the specificity was 65.59%,70.42%,and 45.06%,respectively.The sensitivity of cell DNA quantitative analysis was higher but the specificity was lower than that of TCT,while the sensitivity of combined diagnosis was the highest.In DNA quantitative analysis of patients with and without atypical squamous cells of undetermined significance (ASCUS),the positive rates of pathology were 42.71% and 12.5%,respectively.The misdiagnosis rate of cell DNA quantitative analysis for screening cervical adenocarcinoma (39.13%) was higher than that for screening cervical squamous cell carcinoma (15.11%).In a cytologic smear,the misdiagnosis rate of cells < 5 000 (57.83%) was much higher than that of cells > 5 000 (22.63%).However,a combined diagnosis with TCT could reduce the misdiagnosis rate from 20.19% to 13.38%.Conclusion Cell DNA quantification is more sensitive than TCT,but the specificity of cell DNA analysis is lower than that of TCT,and the screening rate for cervical adenocarcinoma is high.Quantitative DNA analysis combined with TCT can significantly improve the screening sensitivity.
5.Design of a portable external cardiac compression device
Yawei JIANG ; Jian WANG ; Xiaolin ZHANG ; Hanxue LIU
Chinese Critical Care Medicine 2021;33(10):1260-1261
Cardiopulmonary resuscitation (CPR) guidelines emphasize that external chest compressions should be started as soon as possible when CPR is performed in patients with cardiac arrest. Moreover, those guidelines stress on fast and hard compressions to make the chest fully rebound and minimize non-pressing time. Current mechanical recovery device has several problems such as displacement of the pressing position, high price, difficult to move, and easy dislocation of piston. Because of the physical loss of high-intensity unarmed CPR, the depth and frequency of external chest compression will decrease with the extension of CPR time, leading to CPR failure. Besides, there are other problems caused by non-professional staff, such as the deviation of compression position, the inaccuracy of compression depth and the unsatisfactory rebound of the chest wall. Based on the above factors, the medical staff from the intensive care unit of the Eighth Medical Center of the Chinese People's Liberation Army General Hospital designed a portable external chest cardiac compressor based on international CPR guidelines which obtained the National Utility Model Patent of China (ZL 2018 2 1173254.3). The portable external chest cardiac compressor is composed of a positioning sucker, elastic body, mounting shell, and pressing components. Rapid and accurate compression positioning, visible compression depth and full chest rebound can be achieved. This device is mobile, easy to operate, and suitable for a broad crowd and various occasions.
6.Design and application of a pulmonary function exercise bottle.
Hanxue LIU ; Xiaolin ZHANG ; Yuxiang ZHANG
Chinese Critical Care Medicine 2019;31(2):236-237
Chronic obstructive pulmonary disease (COPD) is a severe respiratory disease characterized by airway obstruction with high mortality and rate of recurrence. Rehabilitation exercise can lessen the possibility of the progressive exacerbation of the patient's condition, exerting an active role in improving their lung function and the quality of the patients' life. Therefore, we have designed a lung function exercise bottle, which is capable of adjusting the pressure according to the patient's needs. It is easy to operate and apply in practice. The exercise bottle is composed of three components, including bottle body, threaded round cap and air blow pipe. The bottle body is formed in rectangle shape, and utilized to contain liquid. The filling opening is designed on the top of the bottle. Outside of the filling opening, there is a screw thread round cap, which can adjust the pressure according to the patient's tolerance, gradually increasing the training intensity,and improving the training effect thereby. The blowpipe can be inserted into the bottle body and the patient can blow the air through the tube. Compared with the traditional rehabilitation training, when the newly invented lung function exercise bottle has been used for rehabilitation exercise, the air pressure in the bottle can be adjusted, with the advantage of wider range of application, lower cost and more convenient. It provides a good solution for clinical and home-based rehabilitation and is worth of popularizing.
Equipment Design
;
Exercise Therapy/instrumentation*
;
Humans
;
Lung/physiology*
;
Pulmonary Disease, Chronic Obstructive/rehabilitation*
7.A cross-sectional study on association of blood pressure and risk of diabetes mellitus
Lei FAN ; Minjie QI ; Hanxue ZHANG ; Hui LI ; Yanhui LI ; Xinjie WANG ; Fei SHANG ; Shixian FENG ; Kai KANG
Chinese Journal of Health Management 2022;16(1):15-20
Objective:To assess the association between blood pressure and the risks of diabetes mellitus.Methods:Screening and intervention were conducted from 2015 to 2019 for high-risk subjects of cardiovascular diseases in eight counties of Henan. Information on demographic characteristics, lifestyle behaviors, and anthropometric measurements were obtained via a questionnaire. Fasting blood samples were collected for blood glucose and serum lipids. The R 3.6.3 software was used to analyze the relationship between blood pressure and diabetes mellitus.Results:The detection rate of diabetes mellitus was 23.5% among 120 040 participants aged 35-75 years. The mean fasting blood glucose level was significantly different among normotensive, prehypertensive, and hypertensive patients. Compared to normotensive patients, prehypertension and hypertension had adjusted ORs of 34%( OR=1.34, 95 CI%: 1.30-1.37) and 85%( OR=1.85, 95 CI%: 1.81-1.89). The corresponding ORs were 1.81(1.77-1.85) in controlled and 2.17(2.06-2.28) in uncontrolled patients. A subgroup analysis showed the same trend, where the risk of diabetes increased with blood pressure ( P<0.05). Conclusions:People with elevated BP may increase their risk of diabetes, while the risk declines when BP is under control. Therefore, targeted measures should be taken to reduce the risk.
8.Study on the Chemical Constituents of Ethyl Acetate Fraction of Panax ginseng Fungal Substance
Baijin CHANG ; Zhidong QIU ; Hanxue ZHANG ; Anqi GUAN ; Yingying LIU ; Wei XU
China Pharmacy 2019;30(2):202-206
OBJECTIVE: To study the chemical constituents of ethyl acetate fraction of Panax ginseng fungal substance obtained by biotransformation, in order to obtain compounds with better activity and lower toxicity, and to provide reference for new drug R&D and the second development and utilization of P. ginseng. METHODS: Fungus of Code Name C-1 seed solution was added into the culture medium containing P. ginseng, and P. ginseng fungal substance was obtained by biotransformation; the dried P. ginseng fungal substance were weighed, extracting with 70% ethanol solvent and concentrating to obtain thick paste. The thick paste was added with water suspension and extracted with ethyl acetate to obtain ethyl acetate fraction. TLC, silica gel column chromatography, ODS column chromatography and semi-prepared liquid phase were used to isolate and purify above ethyl acetate fraction, and the compound structure was identified according to physicochemical properties, hydrogen spectrum (1H-NMR) and carbon spectrum (13C-NMR) data. RESULTS: Eight compounds were isolated and identified from the ethyl acetate fraction of P. ginseng fungal substance and identified as ginsenoside Rs7 (1), ginsenoside Rk3 (2), oleanolic acid-28-O-β-D-glucopyranoside (3), ginsenoside Rs6 (4), 20(R)-ginsenoside Rh1 (5), ginsenoside F1 (6), notoginsenoside R2 (7) and ginsenoside F4 (8). CONCLUSIONS: All the above compounds were found in P. ginseng fungal substance, which compounds 3, 5, 6, 7 and 8 were obtained after biotransformation, proving that biotransformation technology can change the chemical composition of ginseng.