1.The value of ultrasonography in diagnosis of hydropneumothorax
Ping SHI ; Yanni HAN ; Yan ZHANG ; Yan ZHAO ; Min PAN
Chinese Journal of Primary Medicine and Pharmacy 2009;16(4):594-595
Objective To investigate the value of ultrasound diagnosing for hydropneumothorax. Methods In a prospective double-blind randomized concurrent controlled trial. 213 patients doubted pneumotborax were exam-ined with CT, senography and conventional radiography. Results In 213 cases, hydropneumothorax diagnosed in 30 hemithoraces of 30 patients by CT,29 hemitboraces by ultrasound and 22 hemithoraces by X-ray. The sensitivity, nega-tive predictive value,accuracy by ultrasound and X-ray were 96.7% vs 73.3% ,99.8% vs 98.0% ,99.8 vs 98.1% respectively(P<0.05), the specificity and positive predictive value of both ultrasound and X-ray were 100%. Ultra-sound surpassed the X-ray in detecting pneumothorax ( McNemar test P<0.025 ). Conclusion If ultrasound is served to detect pneumothorax, it can make up the defects of the methods commonly used cuxrently.
2.Analytical performance of high-sensitivity cardiac troponin I detection by VITROS ECIQ with enhanced chemiluminescence method
Yongshu LI ; Haiqing LIANG ; Xuejing HAN ; Ping SHI ; Kegang JIA
Chinese Journal of Laboratory Medicine 2015;(7):461-465
Objective To evaluate the performances of high-sensitivity cardiac troponin I ( cTnI ) on VITRO ECIQ with enhanced chemiluminescence method .Methods This verification study validated the limited of detection,function sensitivity,imprecision,linearity of the high-sensitivity cardic troponin used VITROS ECIQ according to the document EP-17A, EP-6A,EP-15A published by Clinical and Laboratory Standards Institute (CLSI) and determined 99th percentiles.All 652 patients with chest pain on immediate admission in TEDA International Cardiovascular Hospital during January to November 2013 were enrolled in this study.Including 323 cases of acute ST segment elevation myocardial infarction and non ST segment elevation myocardial infarction patients as the case group , exclude 329 cases of other diagnosis ,303 cases of apparent normal people as control group .The receiver operating characteristic curve was used to evaluated the sensitivity and the specificity of cTnI . Non-normal distribution of quantitative data were used nonparametric test Mann-Whitney U, With P<0.05 for the difference was statistically significant .Results The LoB was 0.006 5 ng/ml and the LoD was 0.015 5 ng/ml;the FS was 0.016 76 ng/ml;repeatability CV
was 1.73 % -2.33 %, reproducibility CV was 4.93% -9.96%.The imprecision were lower than that declared by assay producer.The linearity was 0.015 5-78.4 ng/ml(R2 =0.999 9); the 99th percentile reference value was 0.017 ng/ml.The area under the curve ( AUC) of cTnI was 0.986,95%CI 0.973 -0.994,with the cut-off value as 0.017 ng/ml, the diagnostic sensitivity and specificity in CIN were 90.09%and 99.34%.Compared between STEMI and NSTEMI groups after admission , the levels of cTnI had no significantly difference , Z were -0.485, P >0.05;compared between STEMI and control groups after admission, the levels of cTnI had significantly difference , Z were -19.567,P<0.001;compared between NSTEMI and control groups after admission , the levels of cTnI had significantly difference , Z were-14.598,P<0.001.Conclusions High-sensitivity cardiac troponin I detection by VITROS ECIQ with enhanced chemiluminescence method has good performances of sensitivity , linearity, specificity, which meet the clinical needs.
3.Multi-slice spiral CT angiography of the posterior nutcracker syndrome
Long ZHAO ; Heshui SHI ; Xi LIU ; Ping HAN ; Jie YU
Chinese Journal of Medical Imaging Technology 2009;25(10):1817-1820
Objective To assess the value of multi-slice spiral CT angiography (MSCTA) in diagnosis of posterior nutcracker syndrome (NCS). Methods MSCTA of 15 patients clinically diagnosed as posterior NCS (patient group) and 50 subjects with normal renal vessels (control group) were retrospectively analyzed. The anatomy, course and relationship to the adjacent structure of left renal vein (LRV) and its branches were observed. The anteroposterior diameter (d1) and cross areas (s1) of the angle of control group and posterior abdominal artery (AA), the anteroposterior diameter (d2) and cross areas (s2) at the largest lumen near the renal hilar were measured and the ratio of s2/s1 and d2/ d1 were calculated.Results All LRVs posterior AA of patient group were compressed and narrowing with dilating apparently near the renal hilar. The difference of d2 was not significant (P>0.05), but of other values were significant (P<0.05).Conclusion MSCTA can show anatomy and three-dimentional trend clearly of LRV for posterior NCS, and evaluate the extent of narrow and dilating lumen accurately with cross areas measuring.
4.Clinical analysis of five cases of necrosis of femoral head after acute paraquat poisoning.
Ying-Ping TIAN ; Han-Wen SHI ; Na MENG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2010;28(10):790-791
Adolescent
;
Adult
;
Cyclophosphamide
;
adverse effects
;
Female
;
Femur Head Necrosis
;
etiology
;
Humans
;
Immunosuppressive Agents
;
adverse effects
;
Male
;
Middle Aged
;
Paraquat
;
poisoning
;
Young Adult
5.Metabolic response and dynamic nutrition support after trauma.
Chinese Journal of Burns 2013;29(4):335-337
Trauma can induce a series of dynamic metabolic responses with different characteristics in three stages, including ebb phase, flow phase, and recovery phase. Nutrition support after trauma should be dynamically adjusted according to metabolic response and its individual phase, focusing on energy balance as well as metabolic modulation, adjusting immunological response to trauma by reduction of the exaggerated cytokines production, maintaining body protein balance, and enhancing wound healing.
Energy Metabolism
;
Humans
;
Nutritional Support
;
Wound Healing
;
Wounds and Injuries
;
metabolism
;
therapy
7.Two family members all elevated blood lead the investigation.
Cheng-hong HAN ; Yun-long DING ; Ling HUANG ; Shi-ping DU ; Lü JI
Chinese Journal of Industrial Hygiene and Occupational Diseases 2013;31(9):666-666
Adult
;
Child
;
Child, Preschool
;
Female
;
Humans
;
Infant
;
Lead
;
blood
;
Lead Poisoning
;
blood
;
epidemiology
;
Middle Aged
8.Expression and Significance of A Novel Gene BC047440 in Multiplicate Malignant Tumor Tissues
Lu ZHENG ; Jing LI ; Ping LIANG ; Tong-Han YANG ; Xiao-Bing HUANG ; Shi-Cheng LIU ;
Chinese Journal of Bases and Clinics in General Surgery 2003;0(03):-
0.05).②There were close relationships between BC047440 gene expression and clinicopathologic findings of liver cancer,including tumor size and portal vein invasion(P
10.Thri-operators and the blood-oxygen functional image technology in diagnosing breast cancer
Jianhua SHI ; Linlin ZHEN ; Yumei ZHOU ; Zhaohuan ZHU ; Rong WU ; Xuedong HAN ; Ping ZHANG
Journal of Endocrine Surgery 2009;3(3):161-164
Objective To evaluate thri-operators and the blood-oxygen functional image technology in di-agnosing breast cancer. Methods One hundred and forty-six patients were admitted to hospital for operation due to one hundred and fifty-three suspicious lesions detected in their breasts. These lesions were detected by physical examination, thri-operators and the blood-oxygen functional image, mammography uhrasonography. The sensitivity and specificity of each diagnostic method were obtained and the radiolagie-pathologic correlation was meanwhile calculated. Results Sixty one(41.8%)breast lesions were diagnosed as malignancy. The sensitivity, specificity, accuracy,positive prognostic value and negative prognostic value of ultras onography were 80. 33% ,89. 41%,85.61% ,84.48% and 86.36%. Such data of mammography were 57.89% ,80. 36% ,69.03% ,75.00% and 65. 22%. And those of thri-operators and the blood-oxygen functional image technology were 91.80% ,83.53%, 86.99% ,80.00% and 94.67%. Conclusions Thri-operators and the blood-oxygen functional image technology is superior to uhrasonography and mammography in diagnosing breast lesions with its sensitivity accuracy and neg-ative prognostic value, while specificity and positive prognostic value were between them, have greater value in screeninging and the diagnosing breast cancer.