1.Non-psychiatric nurses' opinions about psychiatric consultation.
Journal of Korean Neuropsychiatric Association 1991;30(3):540-551
No abstract available.
2.Treatment of cystic lymphangioma with topical use of bleomycin in childhood.
Han Cheol CHOI ; Young Wook KIM ; Soo Il CHANG
Journal of the Korean Surgical Society 1993;44(4):598-604
No abstract available.
Bleomycin*
;
Lymphangioma, Cystic*
3.Fibro-osseous Pseudotumor of the Great Toe: A Case Report.
Woo Suk SONG ; Joon Cheol CHOI ; Hak Soo KIM ; Eun Mee HAN
The Journal of the Korean Bone and Joint Tumor Society 2010;16(2):91-94
Fibro-osseous pseudotumor is an extremely rare benign lesion which is fast-growing and painful. It is often misdiagnosed as a malignancy, but it is a noninvasive entity and can be cured by simple resection. We report a case of fibro-osseous pseudotumor of the distal phalanx of great toe in 20-year-old female patient who present with painful mass.
Female
;
Humans
;
Toes
;
Young Adult
4.A study on surface of various abutment screws.
Chan Ik PARK ; Chae Heon CHUNG ; Han Cheol CHOI ; Dae Hwa BACK
The Journal of Korean Academy of Prosthodontics 2003;41(3):351-359
STATEMENT OF PROBLEM: Regardless of any restoration, most of case, we used in screw connection between abutment and implant. For this reason, implant screw loosening has been remained problem in restorative practices. PURPOSE: The purpose of this study was to compare surface of coated/plated screw with titanium and gold alloy screw and to evaluate physical property of coated/plated material after scratch test in FESEM investigation. MATERIAL AND METHODS: GoldTite, titanium screw provided by 3i (Implant Innovation, USA) and TorqTite, titanium screw by Steri-Oss (Nobel Biocare, USA) and gold screw, titanium screw by AVANA (Osstem Implant, korea) - were selected for this study. Each abutment screw surface was observed at 100 times, and then screw crest, root, and slope were done more detailed numerical value, at 1000 times with FESEM. A micro-diamond needle was also prepared for the scratch test. Each abutment screw was fixed, micro-diamond scratch the surface of head region was made at constant load and then was observed central region and periphery of fine trace through 1000 times with FESEM. RESULTS: The surface of GoldTite was smoother than that of other kinds of screw and had abundant ductility and malleability compared with titanium and gold screw. The scratch test also showed that teflon particles were exfoliated easily in screw coated with teflon. Titanium screw had a rough surface and low ductility. CONCLUSION: It was recommended that the clinical use of gold-plated screw would prevent a screw from loosening.
Alloys
;
Head
;
Needles
;
Polytetrafluoroethylene
;
Titanium
5.A case of hyperimmunoglobulin E syndrome.
Myeong Cheol SHINN ; Sung Dong CHOI ; Byung Gyu SUH ; Jin Han KANG ; Joon Sung LEE
Journal of the Korean Pediatric Society 1991;34(2):292-298
No abstract available.
6.Hyperbaric Oxygen Therapy in Decompression Sickness.
In Cheol PARK ; Sae Gwang PARK ; Jin HAN ; Byoung Sun CHOI ; Hee Duck KIM
Journal of the Korean Society of Emergency Medicine 1999;10(1):97-107
BACKGROUND: Scuba diving has become increasingly popular in Korea. Medical problems are common with dives, especially decompression sickness(DCS). This study was performed to obtain an useful information of hyperbaric oxygen therapy in DCS in Korea. METHOD: We reviewed the 62 cases of Korean divers, who were diagnosed as DCS and received recompression therapy according to U.S. Navy Standard Recompression Treatment Table at Ocean and Underwater Medical Research and Training Center of ROK Navy, for 6 years from Jan. 1993 to Nov. 1998. RESULT: 1) the mean no-decompression limit excess time between type I DCS group(72.7 min.) and type II DCS group(92.8min.) showed significant difference. 2) The rate of symptoms appeared on surfacing and within 10min. after surfacing of type I and type II DCS were 41.4%and 72.7% respectively. 3) The cure late of type I and type II were 75.9%and 42.4% respectively. In type II DCS group, the cure rate of the group within 12 hour-delayed recompression treatment and the group above 12 hour-delayed treatment were 64.3%and time 26.3% respectively, and in type I DCS group, 100% and 66.7% respectively. CONCLUSION: These findings suggest that the education of safety, the strict observance of the standard decompression table, and the avoidance of excessive repeated diving are important for reducing the risk of diving related disease. And to offer proper management of DCS, there should be more multiplace hyperbaric oxygen chambers, the suitable transport system, and the specialist of diving medicine or hyperbaric medicine in Korea.
Decompression Sickness*
;
Decompression*
;
Diving
;
Education
;
Hyperbaric Oxygenation*
;
Korea
;
Oxygen
;
Specialization
7.An Animal Experiment on the Biocompatibility of AISI 316 LVM Stainless Steel Plates and Screws Manufactured at KAIST
Han Koo LEE ; Moon Sang CHUNG ; Sang Cheol SEONG ; In Ho CHOI ; Byoung Ho SUH
The Journal of the Korean Orthopaedic Association 1986;21(4):531-537
In order to assess the biocompatibility of domestic dynamic compression plates and screws manufactured at KAIST (Korea Advanced Institute of Science and Technclogy), hematological, serological, histological, and metallurgical studies were carried out on sixty rabbits through thirty-two weeks. The rabbits were divided into two groups, group I: thirty rabbits for KAIST plates and screws, group II: thirty rabbits for Osteo plates and screws. The plate and screws were fixed on the fixed tibial shaft. All the resulg of hematological, serological, histological, and metallurgical study revealed that there were no meaningful differences between the two groups. This, in fact, enco.urages us to use domestic KAIST plates and screws clinically and to develop more complicated designs including total joint replacement system.
Animal Experimentation
;
Animals
;
Joints
;
Rabbits
;
Stainless Steel
8.Experimentally Induced Osteoporosis after Segmental Resection of Nerves, Muscles and Tendons in Rats' Tibiae
Duk Yong LEE ; Sang Cheol SEONG ; In Ho CHOI ; Chin Youb CHUNG ; Moon Sung HAN
The Journal of the Korean Orthopaedic Association 1988;23(2):589-599
We carried out animal experiment in order to determine the effect of resection of nerves, muscles and tendons on the induction of osteoporosis. One hundred and forty rats, weighing approximately 250 gm, were divided into seven groups. In Group I, as a control group, the three skin incisions, one on the anterior aspect of the knee, one on the anteromedial aspect of proximal thigh, and one on the posterior aspect of proximal thigh were made and wounds were sutured. In Group II, the patellar tendon and the extensor digitorum longus tendon were divided to disable knee extension. In Group III, all the knee flexors were divided. In Group IV, all the knee extensors and flexors were divided. In Group V, the femoral nerve was divided to disable knee extension. In Group VI, the sciatic and obturator nerves were divided to diable knee flexion. In Group VII, the sciatic, and obtrator nerves were all divided. Before the procedures, bone density was measured by photon absorptiometry and postoperatively, the measurement was repeated every two weeks until the eighth week. At the time of each measurement, two rats were sacrificed out of each group and were submitted to microphotographic measurement of the tibial cortices. The results were as follows. l. In the muscle and tendon resection groups (Group II, Group III, Group IV), the bone density significantly decreased two weeks after operation and then, gradually increased four, six and eight weeks. 2. In the nerve resection groups (Group V, Group VI, and Group VII), the bone density decreased significantly two and four weeks after operation and then gradually increased six, and eight weeks after operation. 3. In both motor resection and denervation, the paralysis of both flexors and extensors of the knee, caused more decrease in bone density than the paralysis of either flexor or extensor. 4. In the muscle and tendon resection groups, the bone density was significantly more decrease two weeks after operation when the flexors were resected, but thereafter there was no significant difference between the flexors and extensors resection. In the nerve resection group, the paralysis of knee flexors caused more decrease in bone density than the paralysis of knee extensors throughout the entire experimental period. 5. The nerve resection groups demonstrated significantly more severe loss of bone density than muscle and tendon resection groups throughout the entire experimental period. 6. The values of bone density measured by photon absorptiometry correlated well with the cortical thickness indices. Bssed upon these observations, we came to the following conclusions. 1. The osteoporosis following injuries of the nerve, muscle, and tendon is most significant at two weeks after injury. 2. Denervation causes more severe osteoporosis than muscle and tendon injuries. 3. It is suggested that the photon absorptiometry is a reliable means in the evaluation of the osteoporosis.
Absorptiometry, Photon
;
Animal Experimentation
;
Animals
;
Bone Density
;
Denervation
;
Femoral Nerve
;
Knee
;
Muscles
;
Obturator Nerve
;
Osteoporosis
;
Paralysis
;
Patellar Ligament
;
Rats
;
Skin
;
Tendon Injuries
;
Tendons
;
Thigh
;
Tibia
;
Wounds and Injuries
9.Lengthening of Short Tubular Bone by Gradual Distraction
Hui Wan PARK ; Dae Yong HAN ; Chong Hyuk CHOI ; Hyun Cheol OH
The Journal of the Korean Orthopaedic Association 1995;30(5):1361-1366
Thirteen cases of lengthening of short tubular bone by gradual axial distraction using an unilateral external fixator(Orthofix M-100, Orthofix CP0089) are reported. This study aims to prove effective- ness of gradual distraction for lengthening of short tubular bone and usefulness of the newly designed external fixator. Nine patients had brachymetatarsia and four brachymetacarpia. The etiology was consisted of post-traumatic physeal injury in two and congenital in eleven cases. The average amount of lengthening was 14.5mm(37.0%) in metacarpal bone, and 17.3mm(37.5%) in metatarsal. Complications were angular deformity in 3, pin loosening in 2 cases, and premature consolidation, nonunion and pin site infection in one case, respectively. Cosmetical and functional satisfactory results were obtained in all cases. We believe that callotasis is effective for short tubular bone lengthening. Also we confirmed the newly designed external fixa- tor(Orthofix CP0089) useful.
Bone Lengthening
;
Congenital Abnormalities
;
External Fixators
;
Humans
;
Metatarsal Bones
;
Osteogenesis, Distraction
10.Asymptomatic uncemented total hip replacement(Changes in the femur): natural history determined using Tc-99m MDP bone scan.
Chang Dong HAN ; Jin Seok SEO ; Ick Hwan YANG ; Joon Cheol CHOI
The Journal of the Korean Orthopaedic Association 1991;26(1):55-63
No abstract available.
Hip*
;
Natural History*
;
Technetium Tc 99m Medronate*