1.Treatment Strategy for Staphylococcus aureus Bacteremia.
Han Kim SUNG ; Don Oh MYOUNG ; Won Choe KANG
Korean Journal of Infectious Diseases 2002;34(6):380-390
No abstract available.
Bacteremia*
;
Staphylococcus aureus*
;
Staphylococcus*
2.A Case of Congenital Neurofollicular Hamartoma.
Yun Seon CHOE ; Jung Yoon OHN ; Kyu Han KIM
Korean Journal of Dermatology 2016;54(2):153-154
No abstract available.
Hamartoma*
3.Corrosion Characteristics Between Implant Fixture And Abutment Screw.
Su Jin KEE ; Hyeog Sin KWEON ; Han Chul CHOE
The Journal of Korean Academy of Prosthodontics 2000;38(1):85-97
The purpose of this study was to compare the corrosion characteristics between implant fixture and two types of abutment screw; gold screw, titanium screw. The anodic polarization behavior, the galvanic corrosion behavior, and the crevice corrosion behavior of prepared samples were investigated using potentiostat and scanning electron microscope. The results were as follows : 1. Anodic polarization behavior of samples: The primary passivation potential of implant fixture was -420mV, implant abutment was -560mV, titanium screw was -370mV and gold screw was -230mV. All samples were shown to have a high corrosion potential and good formation of passive film. The critical passive current density of gold screw was higher than of other samples and the sample of gold screw showed a unstable passive film formation at passive region. 2. Galvanic corrosion behavior of samples: Contact current density between implant fixture and titanium screw showed 8.023x 10-5C/cm2. Contact current density between implant fixture and gold screw showed 5.142x 10-5C/cm2. 3. Crevice corrosion behavior of samples : The crevice corrosion resistance of sample using titanium screw was higher than that of sample using gold screw, and a severe corrosion morphologies were observed at the fixture-screw interface by the scanning electron microscope.
Corrosion*
;
Titanium
4.Effect Of the Polyethylene Wear On Osteolysis in Cementless Primary Total Hip Arthroplasty: Minimum 5 Years' Follow - Up Study.
Chang Dong HAN ; Wahn Sub CHOE ; Joo Hyung YOO
The Journal of the Korean Orthopaedic Association 1998;33(3):746-758
We measured poiyethylene wear radiographically in 85 cementless primary total hip arthroplasties by the modified technique of Livermore et al. All the patients were followed up for at least five years (mean, 6.31 years; range, 5 years-8 years 2 months). The mean extent of linear wear was 0.88mm (range, 0.0083-3.2839mm), and the mean rate of linear wear was 0.14mm/year(range, 0.00-0.47mm /year). The mean volumetric wear was 539.42mm (range, 5.11 2022.09mm), and the mean rate of volumetric wear was 87.69mm/year(range, 0.65-290.12mm/year). The polyethylene wear was correlated inversely with the patients age only, but was not influenced by weight or gender of the patients, Harris hip score, thickness of the polyethylene, the abduction angle of acetahular cup, or the duration of in situ implantation. Osteolysis developed in the femur of 34 hips(40%) and in the acetabulum of 11 hips(12.9%). Radiographic loosening was found in one case in the femur and none in the acetabul pm. The extent of polyethylene wear was significantly correlated with frequencies and sizes of the osteolytic lesion and was not directly associated with radiographic loosening of the prostheses. Calcar resorption was observed in 39 hips(45.9%) and was not associated with polyethylene wear. These results indicated that polyethylene wear of primary total hip arthroplasty should be considered one of major causes of osteolysis and has no direct relationship with prosthesis loosening. To reduce the extent of polyethylene wear, the material characteristics of polyethylene should be improved or new, durable, articulating materials should be researched.
Acetabulum
;
Arthroplasty
;
Arthroplasty, Replacement, Hip*
;
Femur
;
Hip
;
Humans
;
Osteolysis*
;
Polyethylene*
;
Prostheses and Implants
;
Prosthesis Failure
5.An experimental study on the influence of the intravasculargianturco tupe stents on the vascular structures.
Yeon Hyeon CHOE ; Jae Hyung PARK ; Joon Koo HAN ; Man Chung HAN ; Chu Wan KIM
Journal of the Korean Radiological Society 1991;27(4):431-439
No abstract available.
Stents*
6.Effects of surface coating on the screw release of dental implant screw.
Cheol In KOO ; Chae Heon CHUNG ; Han Cheol CHOE
The Journal of Korean Academy of Prosthodontics 2004;42(2):210-225
STATEMENT OF PROBLEM: Implant screw loosening has been remained problem in restorative practices. Surface treatment of screw plays a role of preventing screw from loosening in implant screw mechanism. PURPOSE: The purpose of this study was to investigate surface characteristics of TiN and ZrN film ion plated screw with titanium and gold alloy screw and to evaluate wear resistance, surface roughness, and film adhesion on screw surface using various instruments. MATERIAL AND METHODS: GoldTite screws and titanium screws provided by 3i (Implant Innovation, USA) and TorqTite screws or titanium screws by Steri-Oss (Nobel Biocare, USA) and gold screws and titanium screws by AVANA (Osstem Implant, korea) were selected. Ion plating which is much superior to other surface modification techniques was carried out for gold screws and titanium screws using Ti and Zr coating materials with nitrogen gas. Ion nitrided surface of each abutment screw was observed with field emission scanning electron microscopy(FE-SEM), micro-diamond scratch tester, vickers hardness tester, and surface roughness tester. RESULTS: 1) The surface of gold screw and GoldTite is more smooth than ones of other kinds of non coated screw. 2) The ZrN and TiN coated surface is the more smooth than ones of other kinds of screw. 3) The hardness of TiN and ZrN coated surface showed higher than that of non coated surface. 4) The TiN coated titanium screw and ZrN coated gold screw have a good wear resistance and adhesion on the surface. 5) The surface of ZrN coated screw showed low surface roughness compared with the surface of TiN coated screw. CONCLUSION: It is considered that the TiN and ZrN coated screw which would prevent a screw from loosening can be appilcable to implant system and confirmed that TiN and ZrN film act as lubricant on surface of screw due to decrease of friction for recycled tightening and loosening.
Alloys
;
Dental Implants*
;
Friction
;
Hardness
;
Hardness Tests
;
Nitrogen
;
Tin
;
Titanium
7.Foreign Body Granulomas of the Breast Presenting as Bilateral Spiculated Masses.
Boo Kyung HAN ; Yeon Hyeon CHOE ; Young Hyeh KO ; Seok Jin NAM ; Jung Hyun YANG
Korean Journal of Radiology 2001;2(2):113-116
In Asia, mammography following the injection of foreign materials into the breasts for cosmetic augmentation is frequently seen and diagnosis based on the typical radiologic findings is straightforward. We report the unusual radiologic findings in two patients with foreign body granulomas caused by injected foreign materials and discovered incidentally during screening work up. The mammographic findings were bilateral, hyperdense, spiculated masses, with occasional microcalcification, and at sonography, markedly hypoechoic, spiculated solid masses, located near the pectoralis muscle and partly extending into it, were observed. These radiologic findings mimicked malignancy.
Breast Neoplasms/radiography
;
Case Report
;
Cholesterol
;
Diagnosis, Differential
;
Esthetics
;
Female
;
Granuloma, Foreign-Body/etiology/*radiography/*ultrasonography
;
Human
;
Injections/adverse effects
;
Mammography
;
Middle Age
;
Paraffin
8.CT findings of rounded atelectasis.
Chan Wha LEE ; Kyu Ok CHOE ; Jong Doo LEE ; Eun Kyoung HAN ; Woo Ick YANG
Journal of the Korean Radiological Society 1991;27(2):231-235
No abstract available.
Pulmonary Atelectasis*
9.Radiologic findings in ovarian endometrioid carcinoma.
Woo Kyung MOON ; Seung Hyup KIM ; Hyun Kyung LEE ; Yeon Hyeon CHOE ; Man Chung HAN
Journal of the Korean Radiological Society 1991;27(6):849-855
No abstract available.
Carcinoma, Endometrioid*
10.Prostatic Tissue in Ovarian Mature Cystic Teratoma: A case report.
Seung Mo HONG ; Mi Sun CHOE ; Eun Mee HAN ; Hun Kyung LEE ; Jae Y RO
Korean Journal of Pathology 1999;33(7):525-528
Ovarian mature cystic teratoma containing benign prostatic tissue is rare and only 11 cases have been reported in the literature to date. We report a case of mature cystic teratoma of the ovary containing prostatic tissue. A 23-year-old female patient came to our hospital complaining of irregular menstruation for 3 months. Her menarche had occurred when she was 13 years old. The patient showed no evidence of virilization nor of endocrinopathy. A goose-egg-sized mass was palpable in the left lower abdomen on physical examination. Ultrasonography revealed a cystic ovarian mass with internal echogenecity. Microscopic finding was consistent with that of usual mature cystic teratoma except for a 1.5 cm focus of prostatic and bladder tissues. Prostatic tissue demonstrated strong immunoreactivity for prostatic specific antigen (PSA), prostatic alkaline phosphatase (PAP) and cytokeratin 7. Basal cells of the prostate glands were positive for high molecular weight cytokeratin (34betaE12). Although ovarian mature cystic teratoma containing prostatic tissue has been reported as a rare occurrence, a careful examination with immunohistochemical staining may increase the detection of prostatic tissue in mature cystic teratoma of the ovary.
Abdomen
;
Adolescent
;
Alkaline Phosphatase
;
Female
;
Humans
;
Keratin-7
;
Keratins
;
Menarche
;
Menstruation
;
Molecular Weight
;
Ovary
;
Physical Examination
;
Prostate
;
Teratoma*
;
Ultrasonography
;
Urinary Bladder
;
Virilism
;
Young Adult