1.Evaluation of the antinociceptive effects of a selection of triazine derivatives in mice
Valiollah HAJHASHEMI ; Ghadamali KHODARAHMI ; Parvin ASADI ; Hamed RAJABI
The Korean Journal of Pain 2022;35(4):440-446
Background:
The authors showed in a previous study that some novel triazine derivatives had an anti-inflammatory effect. The present study was designed to evaluate the antinociceptive effect of five out of nine compounds including two vanillintriazine (5c and 5d) and three phenylpyrazole-triazine (10a, 10b, 10e) derivatives which showed the best anti-inflammatory effect.
Methods:
Male Swiss mice (25–30 g) were used. To assess the antinociceptiveeffect, acetic acid-writhing, formalin, and hot plate tests were used after intraperitoneal injection of each compound.
Results:
All compounds significantly (P < 0.001) reduced acetic acid-induced writhing at tested doses (50, 100, and 200 mg/kg). Also, the percent inhibition of writhing in the acetic acid test showed that at the maximum tested dose of these compounds (200 mg/kg), the order of potencies is as follows: 10b > 10a > 10e > 5d > 5c. In the formalin test, compounds 5d, 10a, and 10e showed an antinociceptive effect in the acute phase and all compounds were effective in the chronic phase. In the hot plate test, compounds 5c, 5d, and 10a demonstrated an antinociceptive effect.
Conclusions
The results clearly showed that both vanillin-triazine and phenylpyrazole-triazine derivatives had an antinociceptive effect. Also, some compounds which showed activity in the early phase of formalin test as well as in the hot plate test could control acute pain in addition to chronic or inflammatory pain.
2.The Relationships Among Occupational Safety Climate, Patient Safety Climate, and Safety Performance Based on Structural Equation Modeling
Hamed AGHAEI ; Zahra SADAT ASADI ; Mostafa MIRZAEI ALIABADI ; Hassan AHMADINIA
Journal of Preventive Medicine and Public Health 2020;53(6):447-454
Objectives:
The aim of the present study was to investigate the relationships among hospital safety climate, patient safety climate, and safety outcomes among nurses.
Methods:
In the current cross-sectional study, the occupational safety climate, patient safety climate, and safety performance of nurses were measured using several questionnaires. Structural equation modeling was applied to test the relationships among occupational safety climate, patient safety climate, and safety performance.
Results:
A total of 211 nurses participated in this study. Over half of them were female (57.0%). The age of the participants tended to be between 20 years and 30 years old (55.5%), and slightly more than half had less than 5 years of work experience (51.5%). The maximum and minimum scores of occupational safety climate dimensions were found for reporting of errors and cumulative fatigue, respectively. Among the dimensions of patient safety climate, non-punitive response to errors had the highest mean score, and manager expectations and actions promoting patient safety had the lowest mean score. The correlation coefficient for the relationship between occupational safety climate and patient safety climate was 0.63 (p<0.05). Occupational safety climate and patient safety climate also showed significant correlations with safety performance.
Conclusions
Close correlations were found among occupational safety climate, patient safety climate, and nurses’ safety performance. Therefore, improving both the occupational and patient safety climate can improve nurses’ safety performance, consequently decreasing occupational and patient-related adverse outcomes in healthcare units.
3.CaRotid Artery Filtering Technique (CRAFT): A Technique for Carotid Artery Stenting with Intrinsic Embolic Protection
Michelle FOO ; Yifan REN ; Jay GAJERA ; Christen D BARRAS ; Hong Kuan KOK ; Ashu JHAMB ; Hussein ABBOUCHIE ; Julian MAINGARD ; Duncan Mark BROOKS ; Hamed ASADI
Neurointervention 2021;16(3):260-266
Purpose:
Carotid artery stenting (CAS) is an established treatment for symptomatic carotid artery stenosis as an alternative to carotid endarterectomy. A variety of techniques and devices have been devised to minimise periprocedural stroke risk using either proximal or distal embolic protection. This study presents a method of embolic protection during CAS–the CaRotid Artery Filtering Technique (CRAFT).
Materials and Methods:
The CRAFT technique employs aspects of both proximal and distal embolic protection. The CASPER RX stent (MicroVention, Tustin, CA, USA), which is a double-layered, closed-cell, micromesh nitinol stent, is deployed across the carotid artery stenosis with the assistance of a FlowGate balloon guide catheter (Stryker Neurovascular, Fremont, CA, USA). The partially deployed stent acts as a distal filter while the balloon guide is deflated midway during stent deployment to prevent distal plaque embolisation, followed by completion of stent deployment and angioplasty.
Results:
A total of 94 patients underwent CAS using the CRAFT technique between June 2016 and March 2021. Successful stent deployment was achieved in all patients. Preliminary results demonstrated acute stent occlusion in 6 patients (6.4%) and distal embolic stroke in 5 patients (5.3%). The median procedural fluoroscopy time was 34 minutes with an interquartile range of 22 to 55 minutes.
Conclusion
The CRAFT technique of CAS presented by this study can be applied in the treatment of symptomatic carotid artery stenosis in both emergency and elective procedure settings with a high technical success and low distal embolic stroke risk.
4.Endovascular Treatment of Intracranial Aneurysms Using the Novel Low Profile Visualized Intraluminal Support EVO Stent: Multicenter Early Feasibility Experience
Michelle FOO ; Julian MAINGARD ; Jonathan HALL ; Yifan REN ; Goran MITRESKI ; Lee-Anne SLATER ; Ronil CHANDRA ; Winston CHONG ; Ashu JHAMB ; Jeremy RUSSELL ; Hong Kuan KOK ; Mark BROOKS ; Hamed ASADI
Neurointervention 2021;16(2):122-131
Purpose:
Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent.
Materials and Methods:
A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated.
Results:
A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm.
Conclusion
Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.
5.Endovascular Treatment of Intracranial Aneurysms Using the Novel Low Profile Visualized Intraluminal Support EVO Stent: Multicenter Early Feasibility Experience
Michelle FOO ; Julian MAINGARD ; Jonathan HALL ; Yifan REN ; Goran MITRESKI ; Lee-Anne SLATER ; Ronil CHANDRA ; Winston CHONG ; Ashu JHAMB ; Jeremy RUSSELL ; Hong Kuan KOK ; Mark BROOKS ; Hamed ASADI
Neurointervention 2021;16(2):122-131
Purpose:
Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent.
Materials and Methods:
A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated.
Results:
A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm.
Conclusion
Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.
6.Contact Aspiration versus Stent-Retriever Thrombectomy for Distal Middle Cerebral Artery Occlusions in Acute Ischemic Stroke: Meta-Analysis.
Kevin PHAN ; Julian MAINGARD ; Hong Kuan KOK ; Adam A DMYTRIW ; Sourabh GOYAL ; Ronil CHANDRA ; Duncan Mark BROOKS ; Vincent THIJS ; Hamed ASADI
Neurointervention 2018;13(2):100-109
PURPOSE: The evidence for endovascular therapy and choice of technique in distal middle cerebral artery (MCA) M2 segment occlusions in acute ischemic stroke remains controversial. We aimed to conduct a systematic review and meta-analysis primarily comparing reperfusion rates of stent-retrieval versus contact aspiration for M2 occlusions. MATERIALS AND METHODS: Study selection included cohorts of patients with distal MCA occlusions in acute ischemic strokes treated with an endovascular approach including stent-retrieval or contact aspiration. Twelve studies were selected for meta-analysis for a total of 835 cases. Meta-analysis by proportions was conducted on parameters including baseline and procedural characteristics, thrombolysis in cerebral infarction (TICI) 2b–3 outcomes, and 90-day modified Rankin scale (mRS) outcomes. RESULTS: Hypertension and hyperlipidemia were more prevalent in stent-retriever patients. Pooled baseline National Institute of Health Stroke Scale scores and Alberta Stroke Program Early Computed Tomography Score imaging scores were similar. Pooled time onset of symptoms to door arrival was higher for the stent-retrieval group (154 vs. 97.4 minutes, P=0.01), as was time to groin puncture (259.9 vs. 156.2 minutes, P=0.02), but there was no difference in procedure time. The TICI 2b–3 recanalization rate was similar (80.5% vs. 86.8%, P=0.168). The frequency of mRS 0–2 at 90-day was also similar (74.5% vs. 59.9%, P=0.120), and an excellent mRS 0–1 was lower for stent-retrievers (39.9% vs. 65.6%, P=0.003). A significant negative correlation was found between onset to groin puncture time and the proportion of patients with a good mRS (r=-0.71, P=0.048). CONCLUSION: Both endovascular techniques achieved recanalization rates greater than 80% and 90-day outcomes of minimal disability with similar complication rates. The literature is skewed by aspiration cases being performed sooner after onset of stroke compared to stent-retriever cases.
Alberta
;
Cerebral Infarction
;
Cerebrovascular Disorders
;
Cohort Studies
;
Endovascular Procedures
;
Groin
;
Humans
;
Hyperlipidemias
;
Hypertension
;
Ischemia
;
Middle Cerebral Artery*
;
Punctures
;
Reperfusion
;
Stroke*
;
Thrombectomy*