BACKGROUND:To evaluate the outcome of cardiopulmonary resuscitation (CPR) in out-of-hospital cardiac arrests (OHCA) in India and factors influencing the outcome. METHODS:The outcome and related factors like demographics, aspects of the OHCA event, return of spontaneous circulation (ROSC) and survival to discharge, among the 80 adult patients presenting to emergency department experiencing OHCA considered for resuscitation between January 2014 to April 2015, were analyzed, according to the guidelines of the Utstein consensus conference. RESULTS: The survival rate to hospital admission was 32.5%, the survival rate to hospital discharge was 8.8%and with good cerebral performance category (CPC1) neurological status was 3.8%. Majority of OHCA was seen in elderly individuals between 51 to 60 years, predominately in males. Majority of OHCA were witnessed arrests (56.5%) with 1.3%bystander CPR rate, 92.5%arrests occurred at home, 96%presented with initial non-shockable rhythm and 92.5%with presumed cardiac etiology but survival was better in those who experienced OHCA at public place, in witnessed arrests, in patients who had shockable presenting rhythm and in those where CPR duration was≤20 minutes. CONCLUSION: Witnessed arrests, early initiation of CPR by bystanders, CPR duration ≤20 minutes, initial presenting shockable rhythm, OHCA with non-cardiac etiology are associated with a good outcome. To improve the outcome of CPR and the low survival rates after an OHCA event in India, focused strategies should be designed to set up an emergency medical system (EMS), to boost the rates of bystander CPR and education of the lay public in basic CPR.
2.Chronology of cardiac dysfunction after permanent pacemaker implantation:an observational 2 year prospective study in North India
Harshit GUPTA ; Hakim Irfan SHOWKAT ; Naved ASLAM ; Rohit TANDON ; G. S. WANDER ; Shweta GUPTA ; Sadaf ANWAR ; Mohd Maqbool SOHIL
International Journal of Arrhythmia 2021;22(2):11-
Background:
The purpose of this study is to evaluate cardiac functions using transthoracic echocardiography, change in lead parameters and electrocardiogram (ECG) morphology in patients undergoing permanent pacemaker implantation over a follow-up period of 6 months.
Methods:
This is a prospective study in patients undergoing permanent pacemaker implantation in a tertiary care hospital. Patients undergoing permanent pacemaker implantation were enrolled for up to one year and Echocardiographic parameters (by 2 blind operators) and ECG parameters were recorded at admission (within 24 h), before discharge (within 7 days of pacemaker implantation), after 1 month (± 7 days) and after 6 months (± 7 days) of follow-up.
Results:
A total of 96 patients (60.4% males and 39.6% female, mean age 66.65 years) were implanted with permanent pacemaker. The mean QRS duration was 133.18 ms and increased significantly to 146.03 ms by 6 months despite septal lead placement in majority (92%) of patients. The mean baseline ejection fraction of 51.47 decreased significantly to 47.83 by 6 months. Diastolic parameters like left atrial volume index, early to late diastolic transmitral flow velocity (E/A) and early diastolic mitral annular tissue velocity (E/e′) showed a significant increase (> 5%) from baseline by the end of first week. By the end of first month, systolic dysfunction of RV sets in with significant (> 5%) change from baseline in parameters like Right ventricle myocardial performance index, transannular plane systolic excursion and right ventricle systolic excursion velocity (RVS′).
Conclusion
We have observed that pacemaker recipients with baseline reduced left ventricle (LV) systolic functions perform significantly worse compared to those with baseline normal cardiac functions and had a higher rate of deterioration of LV function. RV dysfunction is the first abnormality that occurs, by 1 week followed by LV dysfunction which starts by 1 month and the diastolic dysfunctions precede the systolic dysfunction. QRS duration also showed a gradual increase despite septal lead placement in majority (92%) and lead parameters showed no significant change over 6 months.
3.Chronology of cardiac dysfunction after permanent pacemaker implantation:an observational 2 year prospective study in North India
Harshit GUPTA ; Hakim Irfan SHOWKAT ; Naved ASLAM ; Rohit TANDON ; G. S. WANDER ; Shweta GUPTA ; Sadaf ANWAR ; Mohd Maqbool SOHIL
International Journal of Arrhythmia 2021;22(2):11-
Background:
The purpose of this study is to evaluate cardiac functions using transthoracic echocardiography, change in lead parameters and electrocardiogram (ECG) morphology in patients undergoing permanent pacemaker implantation over a follow-up period of 6 months.
Methods:
This is a prospective study in patients undergoing permanent pacemaker implantation in a tertiary care hospital. Patients undergoing permanent pacemaker implantation were enrolled for up to one year and Echocardiographic parameters (by 2 blind operators) and ECG parameters were recorded at admission (within 24 h), before discharge (within 7 days of pacemaker implantation), after 1 month (± 7 days) and after 6 months (± 7 days) of follow-up.
Results:
A total of 96 patients (60.4% males and 39.6% female, mean age 66.65 years) were implanted with permanent pacemaker. The mean QRS duration was 133.18 ms and increased significantly to 146.03 ms by 6 months despite septal lead placement in majority (92%) of patients. The mean baseline ejection fraction of 51.47 decreased significantly to 47.83 by 6 months. Diastolic parameters like left atrial volume index, early to late diastolic transmitral flow velocity (E/A) and early diastolic mitral annular tissue velocity (E/e′) showed a significant increase (> 5%) from baseline by the end of first week. By the end of first month, systolic dysfunction of RV sets in with significant (> 5%) change from baseline in parameters like Right ventricle myocardial performance index, transannular plane systolic excursion and right ventricle systolic excursion velocity (RVS′).
Conclusion
We have observed that pacemaker recipients with baseline reduced left ventricle (LV) systolic functions perform significantly worse compared to those with baseline normal cardiac functions and had a higher rate of deterioration of LV function. RV dysfunction is the first abnormality that occurs, by 1 week followed by LV dysfunction which starts by 1 month and the diastolic dysfunctions precede the systolic dysfunction. QRS duration also showed a gradual increase despite septal lead placement in majority (92%) and lead parameters showed no significant change over 6 months.