1.Efficacy and Safety of a Novel Tapered-Tip Sheath System for Biliary-Lesion Tissue Sampling: A Randomized Controlled Trial
Hirokazu OKADA ; Norimitsu UZA ; Tomoaki MATSUMORI ; Hajime YAMAZAKI ; Muneji YASUDA ; Takeshi KUWADA ; Yoshihiro NISHIKAWA ; Takahisa MARUNO ; Masahiro SHIOKAWA ; Atsushi TAKAI ; Ken TAKAHASHI ; Akihisa FUKUDA ; Etsuro HATANO ; Sachiko MINAMIGUCHI ; Hiroshi SENO
Gut and Liver 2025;19(1):136-144
Background/Aims:
Pathological evaluation is crucial for diagnosing biliary lesions and determining appropriate treatment strategies. However, tissue sampling via the transpapillary route can be difficult. In this study, we aimed to assess the efficacy and safety of a novel tapered-tip sheath system for tissue sampling from biliary strictures.
Methods:
This single-center, randomized, parallel-group clinical trial included patients aged 20 to 85 years admitted to Kyoto University Hospital for biliary strictures. The patients were randomly assigned (1:1) to a new or conventional method group. The primary outcome was technical success of biopsy at the target bile duct using the assigned method, as determined in accordance with the intention-to-treat principle. Adverse events were assessed in all eligible patients.
Results:
Fifty-six patients were assessed for eligibility between September 2020 and March 2023; 50 patients were enrolled. The patients were randomly divided into the new (n=25) method group and the conventional (n=25) method group. Technical success was achieved in 96.0% (24/25) and 48.0% (12/25) of patients in the new and conventional method groups, respectively (risk ratio, 2.00; 95% confidence interval [CI], 1.32 to 3.03; risk difference, 48.0%; 95% CI, 27.0% to 69.0%; p<0.001). Adverse events occurred in 4.0% (1/25) and 36.0% (9/25) of patients in the new and conventional method groups, respectively (risk ratio, 0.11; 95% CI, 0.02 to 0.81; risk difference, –32.0%; 95% CI, –52.3% to –11.7%; p=0.005).
Conclusions
The novel tapered-tip sheath system is a promising option for precisely and safely delivering biopsy forceps to target sites, thereby facilitating the diagnosis of biliary strictures.
2.Efficacy and Safety of a Novel Tapered-Tip Sheath System for Biliary-Lesion Tissue Sampling: A Randomized Controlled Trial
Hirokazu OKADA ; Norimitsu UZA ; Tomoaki MATSUMORI ; Hajime YAMAZAKI ; Muneji YASUDA ; Takeshi KUWADA ; Yoshihiro NISHIKAWA ; Takahisa MARUNO ; Masahiro SHIOKAWA ; Atsushi TAKAI ; Ken TAKAHASHI ; Akihisa FUKUDA ; Etsuro HATANO ; Sachiko MINAMIGUCHI ; Hiroshi SENO
Gut and Liver 2025;19(1):136-144
Background/Aims:
Pathological evaluation is crucial for diagnosing biliary lesions and determining appropriate treatment strategies. However, tissue sampling via the transpapillary route can be difficult. In this study, we aimed to assess the efficacy and safety of a novel tapered-tip sheath system for tissue sampling from biliary strictures.
Methods:
This single-center, randomized, parallel-group clinical trial included patients aged 20 to 85 years admitted to Kyoto University Hospital for biliary strictures. The patients were randomly assigned (1:1) to a new or conventional method group. The primary outcome was technical success of biopsy at the target bile duct using the assigned method, as determined in accordance with the intention-to-treat principle. Adverse events were assessed in all eligible patients.
Results:
Fifty-six patients were assessed for eligibility between September 2020 and March 2023; 50 patients were enrolled. The patients were randomly divided into the new (n=25) method group and the conventional (n=25) method group. Technical success was achieved in 96.0% (24/25) and 48.0% (12/25) of patients in the new and conventional method groups, respectively (risk ratio, 2.00; 95% confidence interval [CI], 1.32 to 3.03; risk difference, 48.0%; 95% CI, 27.0% to 69.0%; p<0.001). Adverse events occurred in 4.0% (1/25) and 36.0% (9/25) of patients in the new and conventional method groups, respectively (risk ratio, 0.11; 95% CI, 0.02 to 0.81; risk difference, –32.0%; 95% CI, –52.3% to –11.7%; p=0.005).
Conclusions
The novel tapered-tip sheath system is a promising option for precisely and safely delivering biopsy forceps to target sites, thereby facilitating the diagnosis of biliary strictures.
3.Efficacy and Safety of a Novel Tapered-Tip Sheath System for Biliary-Lesion Tissue Sampling: A Randomized Controlled Trial
Hirokazu OKADA ; Norimitsu UZA ; Tomoaki MATSUMORI ; Hajime YAMAZAKI ; Muneji YASUDA ; Takeshi KUWADA ; Yoshihiro NISHIKAWA ; Takahisa MARUNO ; Masahiro SHIOKAWA ; Atsushi TAKAI ; Ken TAKAHASHI ; Akihisa FUKUDA ; Etsuro HATANO ; Sachiko MINAMIGUCHI ; Hiroshi SENO
Gut and Liver 2025;19(1):136-144
Background/Aims:
Pathological evaluation is crucial for diagnosing biliary lesions and determining appropriate treatment strategies. However, tissue sampling via the transpapillary route can be difficult. In this study, we aimed to assess the efficacy and safety of a novel tapered-tip sheath system for tissue sampling from biliary strictures.
Methods:
This single-center, randomized, parallel-group clinical trial included patients aged 20 to 85 years admitted to Kyoto University Hospital for biliary strictures. The patients were randomly assigned (1:1) to a new or conventional method group. The primary outcome was technical success of biopsy at the target bile duct using the assigned method, as determined in accordance with the intention-to-treat principle. Adverse events were assessed in all eligible patients.
Results:
Fifty-six patients were assessed for eligibility between September 2020 and March 2023; 50 patients were enrolled. The patients were randomly divided into the new (n=25) method group and the conventional (n=25) method group. Technical success was achieved in 96.0% (24/25) and 48.0% (12/25) of patients in the new and conventional method groups, respectively (risk ratio, 2.00; 95% confidence interval [CI], 1.32 to 3.03; risk difference, 48.0%; 95% CI, 27.0% to 69.0%; p<0.001). Adverse events occurred in 4.0% (1/25) and 36.0% (9/25) of patients in the new and conventional method groups, respectively (risk ratio, 0.11; 95% CI, 0.02 to 0.81; risk difference, –32.0%; 95% CI, –52.3% to –11.7%; p=0.005).
Conclusions
The novel tapered-tip sheath system is a promising option for precisely and safely delivering biopsy forceps to target sites, thereby facilitating the diagnosis of biliary strictures.
4.Efficacy and Safety of a Novel Tapered-Tip Sheath System for Biliary-Lesion Tissue Sampling: A Randomized Controlled Trial
Hirokazu OKADA ; Norimitsu UZA ; Tomoaki MATSUMORI ; Hajime YAMAZAKI ; Muneji YASUDA ; Takeshi KUWADA ; Yoshihiro NISHIKAWA ; Takahisa MARUNO ; Masahiro SHIOKAWA ; Atsushi TAKAI ; Ken TAKAHASHI ; Akihisa FUKUDA ; Etsuro HATANO ; Sachiko MINAMIGUCHI ; Hiroshi SENO
Gut and Liver 2025;19(1):136-144
Background/Aims:
Pathological evaluation is crucial for diagnosing biliary lesions and determining appropriate treatment strategies. However, tissue sampling via the transpapillary route can be difficult. In this study, we aimed to assess the efficacy and safety of a novel tapered-tip sheath system for tissue sampling from biliary strictures.
Methods:
This single-center, randomized, parallel-group clinical trial included patients aged 20 to 85 years admitted to Kyoto University Hospital for biliary strictures. The patients were randomly assigned (1:1) to a new or conventional method group. The primary outcome was technical success of biopsy at the target bile duct using the assigned method, as determined in accordance with the intention-to-treat principle. Adverse events were assessed in all eligible patients.
Results:
Fifty-six patients were assessed for eligibility between September 2020 and March 2023; 50 patients were enrolled. The patients were randomly divided into the new (n=25) method group and the conventional (n=25) method group. Technical success was achieved in 96.0% (24/25) and 48.0% (12/25) of patients in the new and conventional method groups, respectively (risk ratio, 2.00; 95% confidence interval [CI], 1.32 to 3.03; risk difference, 48.0%; 95% CI, 27.0% to 69.0%; p<0.001). Adverse events occurred in 4.0% (1/25) and 36.0% (9/25) of patients in the new and conventional method groups, respectively (risk ratio, 0.11; 95% CI, 0.02 to 0.81; risk difference, –32.0%; 95% CI, –52.3% to –11.7%; p=0.005).
Conclusions
The novel tapered-tip sheath system is a promising option for precisely and safely delivering biopsy forceps to target sites, thereby facilitating the diagnosis of biliary strictures.
5.Stress distribution of cementless stems with unique flanges in a rectangular cross-section: thermoelastic stress imaging study
Hironori TAKEHASHI ; Tomofumi NISHINO ; Hajime MISHIMA ; Hiroshi WADA ; Masashi YAMAZAKI ; Koji HYODO
Journal of Rural Medicine 2021;16(2):83-90
Objective: In this study, thermoelastic stress analysis was conducted to clarify the surface stress distribution of a femur in which a BiCONTACT E stem was inserted. The contact sites between the stem and femur were examined to investigate the association with the range of stress distribution.Materials and Methods: BiCONTACT E was set up using two synthetic femurs that mimic the morphology and mechanical properties of living bone. Preoperative planning was performed using three-dimensional imaging software. The synthetic bone was placed in a sample holder. After the stem was implanted into the synthetic bone, computed tomography imaging was performed. The contact sites between the stem and the cortical part of the synthetic bone were examined using the imaging software. Subsequently, thermoelastic stress measurements were performed on the sample.Results: The results of thermoelastic stress analysis indicated a minimum change in the sum of principal stresses [Δ (σ1+σ2)] on the medial side and a maximum change in the sum of principal stresses on the lateral side. Thus, no minimum change was observed in the sum of the principal stresses at the maximum proximal part. It is reasonable to assume that the use of a cementless stem can inevitably lead to bone atrophy in the proximal part of the femur. The contact sites between the stem and femur were also investigated, and the results of the study clearly and quantitatively demonstrated the correlation of the contact sites with a range of stress distributions.Conclusion: The surface stress distribution of a femur, in which a BiCONTACT E stem was inserted, was clarified. The contact sites between the stem and femur were also investigated. Furthermore, the correlation between these results and clinical bone response was investigated in this study.
6.A Case of Unstable Angina Pectoris With Asymptomatic Internal Carotid Artery and Middle Cerebral Artery Occlusion With Impaired Cerebral Perfusion Reserve Treated With Simultaneous Superficial Temporal Artery-Middle Cerebral Artery Anastomosis and Coronary Artery Bypass Grafting
Kai TAKAYANAGI ; Takeshi OKADA ; Otone ENDO ; Kentaro FUJII ; Tomotaka ISHIZAKI ; Taku HIRAMATSU ; Takenori YAMAZAKI ; Hajime ARIMA
Journal of the Japanese Association of Rural Medicine 2021;70(1):69-75
A 68-year-old woman had unstable angina pectoris with asymptomatic right internal carotid artery and right middle cerebral artery occlusion with impaired cerebral perfusion reserve. The cardiology, cardiovascular surgery, anesthesiology, and neurosurgery departments discussed the treatment plan. We simultaneously performed superficial temporal artery-middle cerebral artery anastomosis and coronary artery bypass grafting to reduce the likelihood of perioperative ischemic stroke. Fortunately, neither cerebral ischemia nor myocardial ischemia occurred. Simultaneous superficial temporal artery-middle cerebral artery anastomosis and coronary artery bypass grafting can be a therapeutic option for patients with unstable angina and impaired cerebral perfusion reserve. However, the risk of bleeding associated with anticoagulation during coronary artery bypass grafting cannot be ignored.
7.Concentrated autologous bone marrow aspirate transplantation versus conservative treatment for corticosteroid-associated osteonecrosis of the femoral head in systemic lupus erythematosus
Yohei TOMARU ; Tomokazu YOSHIOKA ; Junichi NANAKAMURA ; Hisashi SUGAYA ; Shigeo HAGIWARA ; Kento NAWATA ; Seiji OHTORI ; Masashi YAMAZAKI ; Hajime MISHIMA
Journal of Rural Medicine 2021;16(1):1-7
Objective: To compare the outcomes of steroid-associated osteonecrosis of the femoral head in patients with systemic lupus erythematosus who underwent conservative treatment and concentrated autologous bone marrow aspirate transplantationMethods: Osteonecrosis of the femoral head was classified according to the Japanese Investigation Committee system. Concentrated autologous bone marrow aspirate transplantation was performed by aspirating the bone marrow from both iliac crests and then transplanting it to the necrotic area after the core decompression. Patients with >2-year follow-up after the concentrated autologous bone marrow aspirate transplantation in our institution (Group I) and those with >2-year follow-up after the first hospital visit in a cooperative institution (Group II) were included in this study. After a randomized matching based on age, sex, type, stage, and etiology, the collapse rate in pre-collapsed stages and total hip arthroplasty conversion rate in all stages were compared between the two groups.Results: After the matching adjustment, 33 pairs of hips were included. Preoperatively, 1, 2, 16, and 14 hips were classified as types A, B, C1, and C2, respectively, and 15, 13, 2, and 3 hips were classified as stages 1, 2, 3A, and 3B, respectively. The collapse rates in the pre-collapsed stages were 68% and 39% in Groups I and II, respectively. Total hip arthroplasty conversion rates were 33% and 45% in Groups I and II, respectively. However, Group I had significantly higher and lower conversion rates in stages 1 and 3, respectively (both P<0.05).Conclusion: Conservative treatment may be preferable in stage 1 hips. In addition, concentrated autologous bone marrow aspirate transplantation may prevent further collapse in stage 3.