1.Classification research on surface EMG signal based on fuzzy wavelet packet and decision tree
Haizhong ZHU ; Zhizhong WANG ; Xiao HU ; Gang WANG
Chinese Medical Equipment Journal 1989;0(03):-
This paper introduces a method for feature extraction of surface EMG signal with fuzzy wavelet packet and classification with C4.5 decision tree. The application of the method to the classification of four action EMG signals proves its effectivity and high recognition rate.
2.Application of CT navigation in mandibular angle plastic osteotomy
Lejun XING ; Haizhong ZHANG ; Peng CHNE ; Qing XI ; Junfeng DAI ; Zhaoqu WEN ; Jiniia YANG ; Kai ZHU
Chinese Journal of Medical Aesthetics and Cosmetology 2012;18(1):40-43
Objective To summarize the use of the CT-guided mandibular angle plastic osteotomy.Methods The clinical data of mandibular angle plastic osteotomy were analyzed under the CT navigation in recent 3 years in our department.Thin-slice CT scans of the mandibular angle were performed before the operation.The CT data were input to the system of neuronavigation.The surgical procedures were then taken under the CT navigation.Results All of patients who received this new technology obtained good plastic effects and safe operation.The anatomic location accurately achieched with short operation time and less bleeding during the operation and distinct curative effect and fast recovery after operation.The effects of the treatment were fine.No visible complications occurred.Conclusions The CT navigation could fix accurately on position of important blood vessels and nerves which could be injured accidentally during operation and,of course,the safety of the operation is improved.The CT navigation can also determine the position and quantities of osteotomy from three dimensional angles,reduce effectively the surgical complications and the risk of surgery,reduce the psychological burden of patients efficiently and increase their confidence and credibility to the operation and surgeons.
3.Clinical value of serum vaspin in diagnosis of nontraumatic osteonecrosis of femoral head
Jian LIU ; Haizhong SUN ; Xiaolong ZHU ; Biaofang WEI
China Modern Doctor 2024;62(16):66-69
Objective To investigate the clinical value of visceral adipose tissue-derived serine protease inhibitor(vaspin)level in the diagnosis of nontraumatic osteonecrosis of femoral head(NONFH).Methods A total of 77 NONFH patients hospitalized in Linyi People's Hospital from November 2022 to May 2023 were included in necrotic group,and 76 healthy persons in our hospital during the same period were included in normal group.The general data of two groups were compared,and serum vaspin levels of patients with different clinical characteristics in necrotic group were compared.Receiver operating characteristic(ROC)curve was drawn to analyze the diagnostic value of serum vaspin in NONFH.Results The serum vaspin level in necrotic group was significantly lower than that in normal group(P<0.05).Serum vaspin levels in patients with bilateral hip disease were significantly lower than those in patients with unilateral hip disease(P<0.05).Serum vaspin levels in patients with femoral head collapse was significantly lower than that in patients without femoral head collapse(P<0.05).The serum vaspin level decreased with the increase of Association Research Circulation Osseous(ARCO)stage(P<0.05).Serum vaspin level was negatively correlated with ARCO stage and visual analogue scale score(P<0.05),but positively correlated with Harris hip score(P<0.05).ROC curve showed that the area under the curve of serum vaspin for NONFH was 0.868(95%CI:0.813-0.923,P<0.001),sensitivity was 82.9%,specificity was 75.3%.Conclusion Vaspin can be used as a potential serum marker for the diagnosis of NONFH.With the progression of NONFH,the serum vaspin level tends to decrease.
4.Application of intraoral scanning registration implant robot in dental implant surgery
Nenghao JIN ; Bo QIAO ; Liang ZHU ; Fanhao MENG ; Quanquan LIN ; Liangbo LI ; Lejun XING ; Rui ZHAO ; Haizhong ZHANG
West China Journal of Stomatology 2024;42(6):804-809
Objective This paper aims to investigate the application of intraoral scanning and cone beam computed tomography(CBCT)registration implant robot in dental implant surgery.Methods The data of 40 cases with dental de-fect of robot-assisted implantation from November 2023 to May 2024 were retrospectively analyzed.Before the opera-tion,the intraoral scan data and CBCT data of the posi-tioning markers were automatically fused with the initial CBCT images,and the registration error was calculated.The average registration error of positioning markers was determined during the operation,and the implantation ac-curacy was analyzed after the operation.Results The intraoral scan data and CBCT data of 40 patients with dental defect wearing positioning markers were successfully registered with the initial CBCT image,and the registration errors were(0.157±0.026)mm and(0.154±0.033)mm,respectively.Statistical analysis showed no statistical significance between them.The registration errors of the marker was(0.037 3±0.003 6)mm.A total of 55 implants were performed,and the total deviations of the implant point and the apical point were(0.78±0.41)and(0.89±0.28)mm,respectively.The transverse deviations of the implant point and the apical point were(0.44±0.36)and(0.58±0.25)mm,respectively.The depth deviations of the implant point and the apical point were(0.51±0.32)and(0.54±0.36)mm,respectively.The devia-tion of the implant angle was 1.24°±0.67°.Conclusion The fusion technology based on intraoral scanning and CBCT registration can meet the accuracy requirements of preoperative registration of oral implant robots.The technology in-creases the choice of registration methods before robot-assisted dental implant surgery and reduces the multiple radiation exposuresof the patient.