1.Analysis of the experience and procedural complications of trans-radial access versus trans-femoral access for hepatic arterial perfusion chemotherapy in patients with advanced hepatic malignancies:a retrospective study
Tianye LYU ; Mei LI ; Ji′an HE ; Qianfu SUN ; Li WANG ; Hao QIN ; Haipeng YU
Chinese Journal of Internal Medicine 2024;63(2):183-191
Objective:To analyze the differences between trans-radial access (TRA) and trans-femoral access (TFA) in hepatic arterial perfusion chemotherapy (HAIC) in terms of patient experience, postoperative complications, and patient preferences; explore whether TRA in HAIC is associated with better patient experience and compliance; and determine whether it is safer than TFA.Methods:The study was a retrospective cohort study of patients with advanced hepatocellular carcinoma and liver metastases from colorectal cancer treated with HAIC. We enrolled a total of 91 patients with advanced liver malignancies treated with HAIC from November 2022 to May 2023 in the Department of Interventional Therapy and Hepatobiliary Medicine at Tianjin Medical University Cancer Hospital. The patients were divided into three groups: group TRA ( n=20, receiving TRA HAIC only), group TFA ( n=33, receiving TFA HAIC only), and crossover group [ n=19, receiving TFA HAIC (Cross-TFA group) first, followed by TRA HAIC (Cross-TRA group)]. Meanwhile, to facilitate the expression of partial results, all patients receiving TRA HAIC were defined as the TRA-HAIC group ( n=39, TRA+Cross-TRA group), and all patients receiving TFA HAIC were defined as the TFA-HAIC group ( n=52, TFA+Cross-TFA group). The primary research index was the Quality of Life (QOL) visualization scale score. The secondary research index included approach-related and catheter-related adverse events, duration of surgery, and mean length of patient stay. We used various statistical methods such as Mann-Whitney U test, t-test, Chi-square test, Fisher′s exact test, univariate logistic regression analysis, and multi-factor analysis. Results:TRA patients had significantly lower QOL scores than TFA patients (all P<0.001). The QOL scores of the Cross-TRA group were significantly lower than those of the Cross-TFA group (pain at the puncture site Z=-3.24, P=0.001, others P<0.001). The QOL scores of the Cross-TRA group were compared with those of the TRA group, which showed that the scores of the Cross-TRA group in overall discomfort ( Z=-3.07, P=0.002), postoperative toilet difficulty ( Z=-2.12, P=0.034), and walking difficulty ( Z=-2.58, P=0.010) were significantly lower than those of the TRA group. Satisfaction scores were significantly higher in the Cross-TRA group than in the Cross-TFA group ( Z=-3.78, P<0.001), and patients were more likely to receive TRA HAIC as the next procedure ( χ2=30.42, P<0.001). In terms of mean length of stay, patients receiving TRA HAIC had a significantly lower mean length of stay than those receiving TFA HAIC (50.1±3.2 h vs. 58.4±6.4 h, t=7.98, P<0.001). The incidence of radial artery occlusion (RAO) as an approach-related adverse event was 15.4% (6/39) in the TRA-HAIC group, which was significantly higher than that in the TFA-HAIC group (15.4% vs. 0, χ2=8.56, P=0.005). Notably, multifactorial analysis of RAO-related factors showed that intraoperative enoxaparin use and patency of radial artery flow during pressure were significantly associated with a reduced risk of postoperative RAO ( P=0.037 for enoxaparin use and P=0.049 for pressure). Conclusions:With respect to procedure approach, TRA was significantly better than TFA in terms of patient satisfaction and mean length of stay. Through further process optimization and prevention of adverse reactions, the incidence of adverse reactions can be maintained at a relatively low level, so that patients can benefit from TRA in future operations in terms of cost-effectiveness and medical efficiency.
2.Evaluation of the performance of systems for whole blood C-reactive protein detection: a multi-center study
Juan CHENG ; Huaiyuan LI ; Haipeng LIU ; Yuxin WANG ; Jin XU ; Shangyang SHE ; Wei QU ; Yidong WU ; Guixia LI ; Junmei YANG ; Liya MO ; Yun XIANG ; Jiangwei KE ; Liyue KUI ; Lei ZHENG ; Hongbing CHEN ; Zhili YANG ; Xin LYU ; Hong ZHANG ; Zhenhua TANG ; Lijuan MA ; Hongquan LUO ; Xiangyang LI ; Wenli ZHANG ; Hui JIA ; Huiming YE ; Lijun TIAN ; Qiuhui PAN
Chinese Journal of Laboratory Medicine 2021;44(7):633-643
Objective:To explore the performance of the commonly used whole blood C-reactive protein (CRP) detection systems and give related recommendation on the performance requirements of detection systems.Methods:A total of 7 540 venous blood samples from 26 maternal, child and children′s hospitals were collected to conduct this multi-center study on the analytical performance of 5 commonly used whole blood CRP detection systems from March to April in 2019. The blank check, carryover, repeatability, intermediate precision, linearity, sample stability, influence of hematocrit/triglyceride/bilirubin, comparison with SIEMENS specific protein analyzer and trueness were evaluated. The 5 systems included BC-5390CRP autohematology analyzer, AstepPLUS specific protein analyzer, Ottoman-1000 Automated Specific Protein POCT Workstation, i-CHROMA Immunofluorometer equipment Reader and Orion QuikRead go detecting instrument. The 5 systems were labeled as a, b, c, d and e randomly.Results:Within the 5 systems, all values of blank check were less than 1.00 mg/L, the carryovers were lower than 1.00%. The repeatability of different ranges of CRP concentrations including 3.00-10.00, 10.00-30.00 and>30.00 mg/L were less than 10.00%, 6.00% and 5.00%, respectively, and the intermediate precision was less than 10.00%. The linearity correlation coefficients of the 5 systems were all above 0.975, while the slope was within 0.950-1.050. Whole blood samples were stable within 72 hours both at room temperature (18-25 ℃) and refrigerated temperature (2-8 ℃). The CRP results were rarely influenced by high triglyceride or bilirubin, except for the immmunoturbidimetric test based on microparticles coated with anti-human CRP F(ab) 2 fragments. When triglyceride was less than 15.46 mmol/L, the deviation of CRP was less than 10.00%. When bilirubin was less than 345.47 μmol/L, the deviation of CRP was less than 10.00%. CRP was more susceptible to Hct on the systems without Hct correction. The deviation of CRP between different Hct dilution concentration and 40% dilution concentration can reach as high as 67.48%. The correlation coefficients ( r) of 5 systems were all more than 0.975 in the range of 0-300.00 mg/L compared with Siemens specific protein analyzer. All systems passed the trueness verification using the samples with specified values of 12.89 and 30.60 mg/L. Conclusion:The performance of 5 systems can basically meet the clinical needs, but it is suggested that the whole blood CRP detection system without automatic Hct correction should be modified manually.
3.Metal-organic Framework Immobilized Enzyme and Its Application in Screening of Enzyme Inhibitors of Traditional Chinese Medicine:A Review
Haipeng LIU ; Yong ZHANG ; Jing WANG ; Tianci LYU ; Ruixin DING ; Guihua GAO
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):256-264
Enzymes are widely used in chemical and pharmaceutical industries because of their advantages of high efficiency and specificity. However, the shortcomings of the free enzymes, such as poor stability and difficulty in recycling, limit their application. Therefore, the immobilization and application of enzymes have become one of the research hotspots. The selection of the immobilization carriers is a critical step in the process of enzyme immobilization. Metal-organic frameworks(MOFs), a kind of porous materials, are formed by the coordination of metal ions or metal clusters with organic ligands. As an emerging immobilization carrier, its advantages such as high porosity, strong stability, and surface modifiability make it ideal for immobilized enzyme carriers. By immobilizing the free enzyme on MOFs, the above mentioned deficiencies of the free enzymes can be effectively solved, which greatly broaden the applicable condition. Ligand fishing is a method to find receptor-specific ligands from complex components, which has the advantages of high efficiency, simple sample pretreatment and high specificity. The MOF-enzyme complex formed by enzyme immobilization can act as a "fishing rod" for ligand fishing, which can screen out the targets from the complex system of components. The complex chemical composition and various active ingredients of traditional Chinese medicine(TCM) make the ligand fishing technology to play a big role in the screening of enzyme inhibitors from TCM. And the screened enzyme inhibitors are expected to be further developed into the lead compounds with good efficacy and low adverse effects, so the immobilized enzymes of MOFs have a wide application in the screening of active ingredients from TCM. Based on this, this paper summarized the methods of immobilized enzymes of MOFs in recent years, analyzed the characteristics, advantages and disadvantages of each method, and summarized the laws of preparation conditions and mechanisms. Meanwhile, the application and future development of immobilized enzymes of MOFs in the field of enzyme inhibitor screening from TCM were also summarized and prospected, with a view to providing a reference for the development of natural ingredients and the modernization of TCM.
4.Epidemiological characteristics of scrub typhus in Lianyungang City in 2010-2022
Yanze ZHENG ; Yuge CHEN ; Jialing ZHANG ; Furong LYU ; Ming ZHI ; Haipeng LI ; Xing ZHAO ; Anlian ZHOU ; Lei XU
Journal of Public Health and Preventive Medicine 2024;35(3):95-98
Objective To understand the epidemiological characteristics of scrub typhus disease and to provide a scientific basis for the prevention and control of scrub typhus disease. Methods Descriptive epidemiological methods were used to analyze the population and regional distribution of scrub typhus. Seasonal characteristics were analyzed using concentration method and circular distribution method, and incidence trend was analyzed using joinpoint regression model. Results The annual incidence rate of scrub typhus was 0.95/100 000 from 2010 to 2022. The incidence rate of male was 0.77/100 000, lower than that of female 1.12/100 000 (χ2=18.89, P<0.05). The incidence rate of the 60-74 years old group was 3.38/100,000, and the total number of cases in the age group 45-74 years was 416 (74.95%). Occupational distribution was mainly among farmers, with 448 cases (80.72%). The top three regions with the highest number of reported cases (in order: Donghai County, Ganyu District, and Guannan County) reported a total of 416 cases, accounting for 74.95%. Concentration ratio was M=0.9408, and the incidence of scrub typhus disease was strictly seasonal. Circular distribution results showed a-=-62.3728, S=20.8960. The circular distribution results indicated that the peak day was October 19th, and the peak period was between October 7 to December 19. The average annual percentage change (AAPC) of the incidence rate from 2010 to 2022 was 13.70%, 95% CI (-8.62%~41.48%), and the incidence rate showed an upward trend (t=1.15, P=0.249). Conclusion The incidence of scrub typhus disease is strictly seasonal, and the incidence rate over the years shows an upward trend. It is necessary to strengthen monitoring and take various intervention measures to reduce the risk of scrub typhus disease.
5.Experts consensus on the procedure of dental operative microscope in endodontics and operative dentistry.
Bin LIU ; Xuedong ZHOU ; Lin YUE ; Benxiang HOU ; Qing YU ; Bing FAN ; Xi WEI ; Lihong QIU ; Zhengwei HUANG ; Wenwei XIA ; Zhe SUN ; Hanguo WANG ; Liuyan MENG ; Bin PENG ; Chen ZHANG ; Shuli DENG ; Zhaojie LU ; Deqin YANG ; Tiezhou HOU ; Qianzhou JIANG ; Xiaoli XIE ; Xuejun LIU ; Jiyao LI ; Zuhua WANG ; Haipeng LYU ; Ming XUE ; Jiuyu GE ; Yi DU ; Jin ZHAO ; Jingping LIANG
International Journal of Oral Science 2023;15(1):43-43
The dental operative microscope has been widely employed in the field of dentistry, particularly in endodontics and operative dentistry, resulting in significant advancements in the effectiveness of root canal therapy, endodontic surgery, and dental restoration. However, the improper use of this microscope continues to be common in clinical settings, primarily due to operators' insufficient understanding and proficiency in both the features and established operating procedures of this equipment. In October 2019, Professor Jingping Liang, Vice Chairman of the Society of Cariology and Endodontology, Chinese Stomatological Association, organized a consensus meeting with Chinese experts in endodontics and operative dentistry. The objective of this meeting was to establish a standard operation procedure for the dental operative microscope. Subsequently, a consensus was reached and officially issued. Over the span of about four years, the content of this consensus has been further developed and improved through practical experience.
Humans
;
Dentistry, Operative
;
Consensus
;
Endodontics
;
Root Canal Therapy
;
Dental Care