1.The image quality and influencing factors of high-pitch dual-source CT coronary angiography in patients with different heart rates
Kai SUN ; Ruijuan HAN ; Ruiping ZHAO ; Lijun MA ; Zhiqin WANG ; Dongmei ZHAO ; Gang WANG ; Hailiang JIA ; Jingwei BAI ; Lijun WANG ; Ligang LI
Chinese Journal of Radiology 2012;46(9):773-778
Objectives To investigate the image quality,influencing factors and radiation doses of prospectively ECG-triggered spiral acquisition mode (Flash spiral mode)coronary computed tomography angiography (CCTA) using high-pitch dual-source CT in patients with different heart rates.Methods One hundred and thirty-four consecutive patients with mean heart rate (HR) > 65 beats per minute (bpm) and ≤ 100 bpm were included in this study as group A using Flash spiral mode setting at 20% -30% of the R-R interval and 134 consecutive patients with mean HR ≤65 bpm were enrolled as group B using Flash spiral scan mode at 55% of the R-R interval; 134 consecutive patients with mean HR > 65 and≤100 bpm using spiral scan mode were included as group C. The image quality scores, effective radiation dose and influencing factors of image quality in three groups were assessed. All statistical analyses were performed using SPSS.Results (1)The non-diagnostic coronary artery segments in group A (28/1842,1.52%) were more than in group B (8/1819,0.44% ) ( x2 =10.97,P =0.001 ) and there was no significant difference between group A and group C (32/1838,1.74%) ( x2 =0.280,P =0.345).The number of patients with non-diagnostic coronary segments in group A( 10/134,7.5 % )was more than in group B (2/134,1.5 %,x2 =5.52,P =0.018 ),while there was no significant difference between group A and group C (9/134,6.7%,x2 =0.057,P =0.812).(2)The average heart rate variability (HRV) of patients with different image scores in the three groups wcrc significantly different. In group A,the HRV of score 1,2 and 3 were (2.29 ± 1.06),(5.17 ± 1.37),(8.88 ± 1.53) bpm,respectively (F =170.402,P =0.001 ).In group B were (2.26±1.01),(5.97 ±1.82),(12.00 ±9.64) bpm,respectively (F=95.843,P=0.001).In group C were (2.61 ±1.85),(7.90 ±3.97),(11.22 ±5.62) bpm,respectively (F=68.629,P=0.001 ). (3) The average effective radiation doses in groups A and B were significant lower than in group C [ A group was 1.04 ± 0.16,B group was 1.03 ± 0.16 and C group was 7.05 ± 1.05,t =65.5 ( A vs C),P <0.01 ( A vs C) ].Conclusions Flash spiral mode of high-pitch dual-source provides high image quality with significant reduction of radiation exposure in patients with HR ≤ 65 bpm. Patients with heart rates >65 bpm and ≤100 bpm without cardiac arrhythmia can perform CCTA using Flash spiral mode with image acquisition time setting at 20%-30% of the R-R interval.
2.Exploring ways to remove the double J tube fluoroscopically from ureter
Chengshi CHEN ; Jincheng XIAO ; Jing LI ; Weihui YU ; Qiwen BAI ; Pu YU ; Dengwei ZONG ; Hongtao CHENG ; Hongtao HU ; Chenyang GUO ; Hailiang LI
Chinese Journal of Radiology 2016;(2):118-121
Objective To investigate the feasibility and safety of the double J tube removal from ureter under fluoroscopy observation. Methods The medical records of patients in our department from April 2013 to March 2015, who performed“double J tube removal and/or replacement”were retrospectively reviewed and analyzed. These data included gender and age of the patient, position of the double J tube end in the bladder, removal method, fluoroscopy time, postoperative complications and so on. The removal methods were divided into a direct method and an indirect method. The direct method means using the ring of a gooseneck snare to hitch directly the end of double J tube in the bladder, and pulling it to the urethral orifice. For the indirect method, a guide wire and a gooseneck snare first were sent into the bladder to clip the double J tube, then, the ring of the gooseneck snare was used to hitch the end of the guide wire to withdraw the gooseneck snare and the guide wire to the urethral orifice, and the double J tube was pulled to the urethral orifice. The double J tube end position in the bladder had direct relationship with the choice of removal method. The author divided the double J tube end position in the bladder into A type, B1 type, B2 type, and C type. The bladder was divided into four quarters equally. Direct method was suitable for all types, while indirect method was only suitable for B2 and C type. Between April 2013 and September 2014, all patients were treated by the direct method;between October 2014 and March 2015, all patients with B1 and A type were treated by the direct method, and all patients with B2 and C type were treated by the indirect method. According to the success rate of operation, fluoroscopy time, the incidence of different complications, the efficacy and safety were determined. Results This study recruited a total of 49 patients, including 6 males and 43 females, who underwent 114 times of“double J tube removal”. On average, double J tube was removed 2.3 times per case. The overall success rate was 96.5% (110/114). The application of direct method was 92 times, and the success rate was 95.7%(88/92). The application of indirect method was 22 times, and the success rate was 100%(22/22). In this study, there were 4 failures to remove the double J tube, all of which happened in the direct method for the C type of patients. In the successful 110 cases, the average fluoroscopy time was (11.3+9.5) min. The application of direct method was 88 times, and the average fluoroscopy time was (12.3 ± 10.3) min; the application of indirect method was 22 times, and the average fluoroscopy time was (7.6±3.8) min. There were 10 cases with pain in urethral orifice, in which 9 cases was treated with direct method and one with indirect method. There were 5 cases with gross hematuria complicated in direct method. The overall incidence rate of the complications was 13.2% (15/114). All of postoperative complications resolved spontaneously. Conclusion The direct way and the indirect way to remove ureteral double J tube fluoroscopically are feasible and safe .
3.Hemorrhagic shock-induced vascular endothelial glycocalyx damage: progress on mechanism of damage and preventive and therapeutic strategies
Yufang ZHANG ; Hongjie DUAN ; Hailiang BAI ; Ran SUN ; Huiting YUN ; Zheng ZHANG
Chinese Journal of Trauma 2023;39(9):847-856
Hemorrhagic shock, a life-threatening organ hypoperfusion caused by rapid, massive blood loss, is the leading cause of traumatic death in peacetime and wartime. The vascular endothelial glycocalyx (vEG) plays an important role in maintaining microcirculatory homeostasis. Severe ischemia and hypoxia of hemorrhagic shock can damage the vEG, leading to endothelial dysfunction and exacerbated microcirculatory and organ impairments. Therefore, early prevention and treatment of vEG damage in hemorrhagic shock can improve microcirculation dysfunction, which is of paramount importance for therapeutic efficacies and outcomes. There have been many studies on the prevention and treatment of vEG damage in hemorrhagic shock, but none is based on the management of vEG damage. The authors reviewed the progress on the mechanism and preventive and therapeutic strategies of vEG damage caused by hemorrhagic shock, hoping to provide reference for the further research of hemorrhagic shock-induced vEG damage.
4.Surgical treatment of hepatocellular carcinoma with hepatic vein tumor thrombosis
Hailiang LIU ; Maolin YAN ; Yannan BAI ; Jiayi WU ; Shi CHEN ; Yaodong WANG
Chinese Journal of General Surgery 2019;34(8):652-655
Objective To evaluate surgical treatment for hepatocellular carcinoma (HCC) with hepatic vein tumor thrombus(HVTT).Methods We retrospectively analyzed the clinical and pathological data of 23 HCC patients with HVTT undergoing surgical treatment at the Department of Hepatobiliary Surgery,Fujian Provincial Hospital from June 2011 to June 2017,including 14 patients with HVTT and 9 patients with inferior vena cava tumor thrombosis (IVCTT).Results 21 patients with HVTT underwent anatomical hepatectomy and 2 underwent partial resection.The HVTT operation time was (235 ± 45) min,and the IVCTT operation time was (308 ± 75) min.The intraoperative blood loss was (880 ± 677) ml,(1 150 ±808) ml,respectively.The follow-up time after surgery was 3 to 44 months.The median tumor-free survival time of the 23 patients was 5 months,and the median survival time was 16 months.The median survival time of HVTT and IVCTT was 14 months and 17 months,respectively.The 1-,2-,and 3-year survival rates of the 23 HCC with HVTT/IVCTT were 56.5%,21.7%,and 8.7%,respectively.Conclusions Surgical treatment is a choice of therapy for HCC patients with HVTT/IVCTT having good liver function,limited and removable lesion,and no distant metastasis.
5.New research direction of organ dysfunction caused by hemorrhagic shock: mechanisms of mitochondrial quality control
Zheng ZHANG ; Hongjie DUAN ; Jiake CHAI ; Xiaofang ZOU ; Shaofang HAN ; Hailiang BAI ; Yufang ZHANG ; Huiting YUN ; Ran SUN
Chinese Critical Care Medicine 2024;36(1):93-97
Hemorrhagic shock (HS) is one of the leading causes of death among young adults worldwide. Multiple organ dysfunction in HS is caused by an imbalance between tissue oxygen supply and demand, which is closely related to the poor prognosis of patient. Mitochondrial dysfunction is one of the key mechanisms contributing to multiple organ dysfunction in HS, while mitochondrial quality control regulates mitochondrial function through a series of processes, including mitochondrial biogenesis, mitochondrial dynamics, mitophagy, mitochondrial-derived vesicles, and mitochondrial protein homeostasis. Modulating mitochondrial quality control can improve organ dysfunction. This review aims to summarize the effects of mitochondrial dysfunction on organ function in HS and discuss the potential mechanisms of mitochondrial quality control, providing insights into the injury mechanisms underlying HS and guiding clinical management.
6. Alteration of oxidative stress and expression of antioxidases in diaphragm of severely burned rats
Hongjie DUAN ; Yanqi HE ; Chen CHEN ; Hengbo ZHANG ; Hailiang BAI
Chinese Journal of Burns 2019;35(7):507-511
Objective:
To explore the occurrence of oxidative stress and antioxidases expression in diaphragm of severely burned rats, so that the mechanism of respiratory muscle atrophy and dysfunction post-burn injury will be further clarified.
Methods:
Eighty male Wistar rats (aged 7 to 8 weeks) were divided into sham injury group and burn injury group according to the random number table, with 40 rats in each group. Rats in burn injury group were inflicted with 50% total body surface area full-thickness scald (hereinafter referred to as burn) on the back and abdomen by immersing into 80 ℃ water for 15 s and 8 s respectively. Immediately after injury, 40 mL/kg normal saline was injected through abdomen for resuscitation, and the wounds were treated with iodine. Except for immersing into 37 ℃ warm water and no resuscitation, the other treatments of rats in sham injury group were the same as those of burn injury group. Whole diaphragms of 8 rats per time point per group were collected after anesthesia at post injury hour (PIH) 2 and on post injury day (PID) 1, 3, 7, and 14, and muscle mass was determined. The protein carbonyl content was determined by microplate reader. The protein expressions of catalase, superoxide dismutase 2 (SOD2), and glutathione peroxidase 1 were determined by Western blotting. Data were processed with analysis of variance of factorial design,
7.Assessment of Radiation Shielding Requirements for Radiotherapy Room—Part 2: Radiotherapy Room of Electron Linear Accelerators (GBZ/T 201.2—2011): A survey of relevant personnel in medical institutions
Zechen FENG ; Zipo ZHAI ; Xiaosan XU ; Hailiang LI ; Hui XU ; Limeng CUI ; Hezheng ZHAI ; Hongfang WANG ; Bin BAI ; Yongzhong MA
Chinese Journal of Radiological Health 2023;32(5):484-488
Objective To investigate the awareness of the Radiation Shielding Requirements for Radiotherapy Room–Part 2: Radiotherapy Room of Electron Linear Accelerators (GBZ/T 201.2—2011) among relevant practitioners in medical institutions as well as its implementation and application situation and collect relevant problems and suggestions for an evaluation of the scientificalness, standardization, and timeliness of the standard, and to provide a scientific basis for the further revision and implementation of the standard. Methods An online questionnaire survey was conducted among relevant employees in medical institutions providing medical linear accelerator radiotherapy across 22 provinces of China, which investigated the awareness, training, application, and revision suggestions related to GBZ/T 201.2—2011. The questionnaires were collected and analyzed. Results A total of 340 relevant practitioners filled out the questionnaire. Of the participants, 66.80% were physicists; 79.11% had an awareness of the standard; 56.18% ever participated in the standard-related training; but the survey results showed that the practitioners did not have a good knowledge of the standard’s content, and the training and promotion were not enough; 83.24% thought that the standard had been widely used; 17.60% thought that the standard needed to be revised; 76.76% thought that there was a need to add calculation examples; 88.82% thought that neutron shielding needed to be considered for the 10 MV X-ray accelerator room. Conclusion The standard has been widely known in the field of radiotherapy protection. With the development of radiotherapy technology, the standard should be revised to add calculation examples and consider neutron shielding in the 10 MV X-ray accelerator room. The standard is highly technical and difficult to grasp, so the promotion and implementation goals should be appropriate for different personnel groups, the training for employees at key posts should be strengthened, and the methods recommended in the standard should be uniformly used throughout the country.