1.Incidence of cerebral venous sinus thrombosis in patients with idiopathic intracranial hypertension
Zhen-Qiang DING ; Hai-Yue JU ; Shi-Hui WEI ;
Ophthalmology in China 2006;0(06):-
Objective To explore the rate of incidence of cerebral venous sinus thrombosis(CVST)in patients with idiopathic in- tracranial hypertension(IIH).Design Restrospective case series.Participants 92 cases with idiopathic intracranial hypertension.Meth- otis All patients diagnosed with papilledema from January 1,2000 through May 1,2007 at our ophthalmology center.Consecutive pa- tients with a diagnosis of papilledema were identified.Patients with space-occupying lesions,hydrocepbalus,or meningitis were excluded. The remaining patients were evaluated with lumbar puncture,magnetic resonance imaging(MRI)and magnetic resonance venography (MRV).Main Outcome Measures The rate of incidence of cerebral venous sinus thrombosis(CVST)in patients with idiopathic in- tracranial hypertension(IIH).Results Excluding patients with mass lesions,meningitis,or hydrocephalus,the occurrence of CVST was 7 (7.6%)of 92 patients with presumed IIH.One additional patients had a diagnosis of suspected CVST.Cerebral venous sinus thrombosis was diagnosed in 1 of the 7 patients with MRI alone,whereas it was evident in all 7 patients with MRV.Conclusions Cerebral venous si- nus thrombosis accounts for 7.6% of patients with presumed IIH in our ophthalmology services.Magnetic resonance venography in com- bination with MRI is recommended to identify this subgroup of patients.(Ophthalmol CHN,2007,16:410-413)
2.Clinical value of double respiratory navigator-gated high-resolution black-blood coronary artery wall magnetic resonance imaging.
Hai-yue JU ; Li YANG ; Liu-quan CHENG ; Zu-long CAI
Acta Academiae Medicinae Sinicae 2013;35(3):305-310
OBJECTIVETo explore the value of phase ordering with automatic window selection(PAWS)and simultaneous multiple volume(SMV)algorithm double respiratory navigator-gated two-dimensional(2DNAV)dual inversion recovery(DIR)fast spin echo(FSE)high-resolution black-blood coronary artery wall magnetic resonance imaging(MRI)and evaluate its advantages and limitations.
METHODSPAWS and SMV 2DNAV DIR FSE high-resolution black-blood MRI was performed in 21 healthy volunteers. The images were evaluated qualitatively by using four grades(grade 0can not evaluate;grade 1bad;grade 2good;grade 3perfect). Images defined as grade 0 and grade 1 were excluded and those defined as grade 2 and 3 were evaluated further. Thickness of proximal(or middle)segment of right coronary artery(RCA)and left anterior descending branch(LAD)were measured. The difference of wall thickness was analyzed by using two-tailed independent sample t-test. P values of less than 0.05 were considered statistically significant.
RESULTSAmong the 38 slice images,31 slices(RCA13 slices,LAD18 slices;grade 214 slices,grade 317 slices)were obtained for further evaluation. The mean thickness of RCA and LAD was(0.94±0.16)and(0.89±0.15)mm,respectively,and the difference was not significant(t=-0.790,P>0.05).
CONCLUSIONPAWS and SMV algorithm 2DNAV DIR FSE high-resolution black-blood MRI has certain clinical value for coronary artery wall imaging.
Adult ; Coronary Vessels ; anatomy & histology ; Female ; Humans ; Magnetic Resonance Imaging ; methods ; Male ; Middle Aged ; Young Adult
3.Evaluation of the safety of metallic elements in borosilicate glass controlled injection bottle by ICP-MS
chun Ai JU ; Chao PAN ; yan Hai LI ; shui Hong YUE
Drug Evaluation Research 2017;40(11):1569-1575
Objective Determination of extractable components in medium/low borosilicate glass controlled injection bottles under 5 different extraction conditions,assess the risk of drug safety by the amount of migration.Methods Determination of 24 elements in extraction solution by ICP-MS.Result Establish the standard curves of 24 elements,and the detection limit and quantitative limit were determined.The determination of the elements in the 5 extraction solutions was completed and their safety was evaluated.Conclusion Medium/low borosilicate glass injection bottle for packing freeze-dried products of Tianjin Tasly Pride Pharmaceutical Co.,Ltd.,the daily intake of Li、V、Cr、Fe、Co、Ni、Cu、Zn、As、Cd、Sb、Ba、Hg、Pb was lower than permitted daily exposure,the amount of migration does not pose a risk to drugs,therefore,the injection quality is not affected.
4.Diagnostic accuracy and its affecting factors of dual-source CT for assessment of coronary stents patency and in-stent restenosis.
Xing-Hua ZHANG ; Li YANG ; Jian WU ; Hai-Yue JU ; Fan ZHANG ; Bin HE ; Yun-Dai CHEN
Chinese Medical Journal 2012;125(11):1936-1940
BACKGROUNDIn-stent restenosis is a common complication after stent implantation. However, the assessment of stent lumen in computed tomography (CT) coronary angiography is limited by multiple factors. Our study aimed to evaluate the accuracy and the suspected affecting factors in diagnosing coronary in-stent restenosis by dual-source CT (DSCT) compared with coronary angiography.
METHODSOne hundred and fifteen stents in 50 patients were evaluated with DSCT before coronary angiography for the detection of coronary in-stent restenosis (≥ 50% luminal narrowing). Patency of each stent was analyzed by two independent expert radiologists blinded to the results of coronary angiography. The relationship between diagnostic accuracy and the suspected factors including age, body mass index (BMI), heart rate, variation of heart rate, radiation dose, image quality, location and stent characteristics (type, material, diameter, length and strut thickness) was assessed with both univariate and multivariate analysis. The fitting of a Logistic regression model was evaluated using a receiver operating characteristic (ROC) curve.
RESULTSMean stent diameter was (2.9 ± 0.4) mm. Sensitivity, specificity, positive and negative predictive values and accuracy of DSCT in detection of in-stent restenosis were 69.2%, 91.2%, 50.0%, 95.9%, and 88.7%, respectively. In a subgroup of stents with a diameter ≥ 3.0 mm, sensitivity, specificity, positive and negative predictive values and accuracy were 100.0%, 96.5%, 75.0%, 100.0%, and 96.8%, respectively. Stent diameter < 3.0 mm and poor image quality were associated with poor diagnostic accuracy (P < 0.05). The area under curve of ROC was 0.79.
CONCLUSIONDSCT can provide high accuracy for the assessment of in-stent restenosis in stents with a diameter = 3.0 mm, and can play an important role in ruling out in-stent restenosis.
Adult ; Aged ; Aged, 80 and over ; Body Mass Index ; Coronary Angiography ; methods ; Coronary Restenosis ; diagnosis ; diagnostic imaging ; Female ; Humans ; Male ; Middle Aged ; Tomography, X-Ray Computed ; methods
5.Volumetric measurement of pericardial and intrathoracic adipose tissues using coronary computed tomography angiography in patients with coronary heart disease.
Jian WU ; Xing-hua ZHANG ; Hai-yue JU ; Fan ZHANG ; Li YANG
Journal of Southern Medical University 2011;31(3):453-456
OBJECTIVETo investigate the feasibility of volumetric measurement of pericardial adipose tissue (PAT) and intrathoracic adipose tissue (IAT) using coronary computed tomography angiography (CTA), and explore the characteristics of PAT and IAT distribution.
METHODSThe CTA images of 109 patients (aged 59.1∓11.7 years) with a clinical diagnosis of coronary heart disease were analyzed. The volumes of PAT and IAT were measured using the axial data from the base to the apex traced manually with the dedicated semiautomatic software program Volume. The related factors and gender difference of PAT and IAT were analyzed.
RESULTSThe pericardium was clearly defined on CTA images and the volumes of PAT and IAT were measured accurately in all the cases. The volumes of PAT and IAT were positively correlated to body weight and body mass index (BMI) but independent of age, and IAT was positive correlated to the body height. The IAT of male patients was 67% higher than that of female patients (P<0.05), whereas no such a difference was found in PAT (P<0.05).
CONCLUSIONCTA-based semiautomatic segmentation for volumetric quantification of PAT and IAT is highly accurate. The volumes of PAT and IAT are positively correlated to body weight and BMI, and PAT volume exhibits no statistical difference between male and female patients with coronary heart disease.
Adipose Tissue ; diagnostic imaging ; Aged ; Body Mass Index ; Coronary Angiography ; Coronary Artery Disease ; diagnostic imaging ; Female ; Humans ; Male ; Middle Aged ; Pericardium ; diagnostic imaging ; Tomography, X-Ray Computed ; methods
6.Reconstruction of a finite element model of intracranial aneurysms based on CT images
Fu-Yu WANG ; Bai-Nan XU ; Lei LIU ; Hai-Yue JU ; Xiao-Jun ZHANG ; Xiao-Yang LI
Chinese Journal of Neuromedicine 2009;8(6):585-587
Objective To establish a three-dimensional (3D) finite element model of intracranial aneurysms based on CT images for three-dimensional simulation of the hemodynamics in the aneurysms. Methods CT angiographic (CTA) images of the intracranial aneurysms were obtained using a GE Lightspeed 16-slice spiral CT with the slice thickness of 0.625 mm at the interval of 0.5 mm. The original Dicom format images were directly imported using the Mimics software. Threshold-based combined with manual segmentation of the images was carried out to acquire the region of interest including the aneurysm and parent artery, followed by 3D calculations of the images. The 3D model was remeshed and exported as an area mesh file to Ansys. The area-based file was then converted into an IGES file in Ansys, and exported to the Ansys workbench software to generate the volumetric mesh for further homodynamic study. Results A 3D finite element model of intracranial aneurysm was established, and the area mesh file could be directly introduced into Ansys software to allow homodynamic study of the aneurysm. Conclusion The application of thin-layer CT scanning and the Dicom standard allows more accurate reconstruction of the 3D finite element model of intracranial aneurysms. The Mimics software can greatly improve the efficiency ofintracranial aneurysm model reconstruction.
7.The clinical characteristics and prognoses of de novo acute myeloid leukemia patients with DNA methyltransferase 3A gene mutations.
Yue QI ; Su Jun GAO ; Hai LIN ; Ye Hui TAN ; Qiu Ju LIU ; Jing Nan SUN ; Xin Yue LIANG ; Long SU ; Rui Ping HU ; Wei LI
Chinese Journal of Hematology 2019;40(3):227-231
8.Complete genome sequence characteristics of human echovirus 9 strain isolated in Yunnan, China.
Yan-Ju ZHU ; Yue PAN ; Jun-Ying CHEN ; Ya-Ling LIU ; Hai-Jing SHI ; Hong-Wei LIAO ; Qiang-Ming SUN ; Shao-Hui MA
Chinese Journal of Virology 2013;29(2):132-136
To analyze the genomic sequence characteristics of a human Echovirus 9(ECHO-9) strain isolated from a child with Hand-foot-mouth disease (HFMD) in Kunming, Yunnan Province, in 2010. The complete genome sequence of a human echovirus 9 strain, MSH-KM812-2010 was determined. As other human enterovirus, its genome was 7,424 nucleotides (nts) in length and encoded for 2,203 amino acids (aas). In comparison to other human enteroviruses, MSH-KM812-2010 strain had the highest homology with other strains of human echovirus 9 in structural genomic regions and more homologous to other serotypes of B specie than to human echovirus 9 in non-structural genomic regions. Phylogenetic analysis based on complete VP1 gene revealed that the sequences of human echovirus 9 segregated into three distinct clades A, B and C with more than 15. 0% diversity between clades. All Chinese isolates belonged to the same clade. RDP3 and Blast revealed evident recombination in non-structural genomic regions. This report is the first to, describe the complete genome of the human echovirus 9 in China and provide an overview of the diversity of genetic characteristics of a circulating human echovirus 9.
Base Sequence
;
China
;
Echovirus 9
;
classification
;
genetics
;
isolation & purification
;
Female
;
Genome, Viral
;
Humans
;
Infant
;
Molecular Sequence Data
;
Phylogeny
;
Viral Proteins
;
genetics
9.Application of low-concentration contrast agent and low-dose technology in 320-slice CT pulmonary angiography
Lin-Zhi DU ; Man-Ping CHENG ; Juan-Qin NIU ; Jian-Jun YE ; Xiao-Dong HAO ; Xiao-Ping YANG ; Gang CHEN ; Ju-Hong YANG ; Xin-Yi LI ; Hai-Xia QIANG ; Yue QIAN ; Yue-Dong HAN
Chinese Medical Equipment Journal 2018;39(1):62-65
Objective To explore the feasibility of low-concentration contrast agent and low-dose technology for pulmonary angiography by comparing the image quality and radiation doses to the patient by different tube voltages and concentrations of contrast agents.Methods Totally 60 patients suspected with pulmonary embolism were divided into C, L1 and L2 groups, of which,Group C had the scanning parameters of 120 kV and 350 mgI/ml,Group L1 had the parameters as 100 kV and 350 mgI/ml and Group L2 had the parameters of 100 kV and 270 mgI/ml.The three groups had the tube voltage as 500 mA, the contrast agent dose as 25 ml,physiological saline dose as 40 ml and flow rate as 4.5 ml/s.SPSS 19.0 software was used to compare and analyze the CT values of pulmonary artery segment,superior vena cava and ascending aorta,main pulmonary artery noises,the image quality as well as the radiation doses of volume scanning. Results The three groups had the main pulmonary aortas and their branches display clearly to meet clinical requirements.When compared with Group C,Group L1 had higher CT values of the main pulmonary aorta and its branches,higher image noise while lower radiation dose (P<0.01);Group L2 had equivalent CT values of the main pulmonary aorta and its branches (P>0.05),higher image noise while lower radiation dose (P<0.01).When compared with Group L1,Group L2 had lower CT values of the main pulmonary aorta and its branches (P<0.01),and equivalent image noise and radiation dose (P>0.05).Conclusion Low-concentration contrast agent and low-dose technology gains feasibility and advantages when used in 320-slice CT pulmonary angiography.
10.Findings of high resolution computerized tomography of the chest in children with interstitial lung disease.
Xin-Yu YUAN ; Chun-Ju ZHOU ; Guang-Min NONG ; Xiu-Yun LIU ; Rong-Yan HUANG ; Shun-Ying ZHAO ; Zhi-Min CHEN ; De-Yu ZHAO ; En-Mei LIU ; Li DENG ; Yue-Jie ZHENG ; Ji-Rong LU ; Yun-Xiao SHANG ; Hai-Ling ZHANG ; Yun PENG ; Ji-Zhen ZOU ; Hui-Zhong CHEN
Chinese Journal of Contemporary Pediatrics 2012;14(4):310-313