2.Establishing the System of Academic Assessment and Evaluation on Introduced Talented Personnel
hai-ying, ZHU ; li-jin, CHEN ; xu-ming, ZHU
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(09):-
Objective To evaluate the system of academic assessment and evaluation on introduced talented personnel so as to establish a consummate talented personnel introduction mechanism and to further standardize the introduction work. Methods On the basis of referring to document papers and soliciting management as well as human resource experts iteratively,the research method of expert consultation was adopted.(Results)The index system of academic assessment and evaluation on introduced talented personnel in school of medicine was preliminary established,and the objective index and subjective evaluation were scientifically combined to form the method of academic assessment and evaluation on introduced talented personnel. Conclusion Through simulative assessment and evaluation as well as probational demonstration,there exits definite scientificality and applicability on this academic assessment and evaluation index system,and it can provide a properly objective evaluation and essential reference foundation in the aspect of introducing more advanced talented personnel in the near future.
3.Ifosfamide and vinorelbine combined chemotherapy in the treatment of advanced non-small cell lung cancer
Yi LAO ; Shao-Feng CHEN ; Gui-Hua LEI ; De-Ming XU ; Wei WANG ; Hai-Ming ZHONG ;
Chinese Journal of Primary Medicine and Pharmacy 2006;0(08):-
Objective To evaluate therapeutic effects and toxicity of advanced non-small cell lung cancer (NSCLC)treated by combining chemotherapy on ifosfamide(IFO)and vinorelbine(NVB).Methods 107 cases pa- tients with advanced NSCLC were enrolled.IFO was given in a dosage of 1.5g/m~2 on day 1 to 4.and NVB in a dosage of 25mg/m~2 on day 1 and 8.It was repeated every three or four weeks,up to two to four cycles.Results Two patients had complete response and 40 patients had partial response.The overall response rate was 47.7% ,the median survival time 10.3 months,1-year and 2-year survival rate was 42% and 12.3%,respectively.The main toxicity was bone marrow suppression.Conclusion The regimen is effective,sale and tolerable in advanced non- small cell lung cancer therapy.
4.Diagnostic of MR in ureter transitional cell carcinoma
Qian-De QIU ; Xian-Ri GUO ; Jia-Jun XU ; Xu-Ming LIU ; Hai WU ;
Chinese Journal of Radiology 1999;0(10):-
Objective To study the feature of MRI in ureter transitional cell carcinoma,to evaluate the diagnostic value in transitional cell carcinoma of ureter with MRI.Methods Heavily T_2-weighted fast spin echo pulse sequence,fat suppression pulse and MR urography(MRU)were performed.The MRI finding of the ureter transitional cell carcinoma were anlysed in 32 cases and were discssed with the review of literature.Results Fifteen lesions were located at the upper portionof the ureter,7 at mid portion and 10 at lower portion.Each case presented urinary obstruction,distention and uretal hydrocele.21 retrograde urleropyelogrhpy of nodular shaperal irregular,11 irregular the ureteral wall,10 dilate the ureter in 21 cases,11 infitrative lesion to grow in location,9 lymphanode to enlarge in surrounding of major arterial of abdominal and renal out in 11 cases.17—72 mm length the lesion,39 mm average,6—50 mm width the leion,17 mm average.Hypointense on T_1 WI and hyperintense on T_2 WI image in 23 cases,hyperintense on both T_1 WI and T_2 WI image in 5 cases,hypointense on T_1 WI and isointense on T_2 WI image in 2 case, slightly hypointense on both T_1 WI and T_2 WI images in 2 case.Ninteen homogeneous and 13 non homogeneous of signal in lesion,22 reliable and 5 suspicious diagnosis and 5 misdiagnosis in MRI. Conclusion The location,the shape,the spectrum of the tumor and change of surrounding tiessue were clear cuted in MRI,but further research in confirmation of the diagnosis.
5.Design of a noninvasive ventilator's turbine.
Ya-Xu ZHOU ; Zhao-Yan HU ; Min ZHAN ; Bin GE ; Hai-Ming XIE
Chinese Journal of Medical Instrumentation 2008;32(2):97-82
The design principles of a noninvasive ventilator's turbine are studied and discussed in this paper. The design is completed from its several aspects and in combination of related theories, using SolidWorks tools. Abundant experimental results prove that this design's technical specifications meet all the requirements.
Equipment Design
;
Respiration, Artificial
;
instrumentation
;
methods
;
Ventilators, Mechanical
6.Design, synthesis and biological evaluation of novel para-substituted 1-benzyl-quinazoline-2, 4 (1H, 3H)-diones as human PARP-1 inhibitors.
Hai-Ping YAO ; Zhi-Xiang ZHU ; Ming JI ; Xiao-Guang CHEN ; Bai-Ling XU
Acta Pharmaceutica Sinica 2014;49(4):497-503
Poly(ADP-ribose) polymerase-1 (PARP-1) has emerged as a promising anticancer drug target due to its key role in the DNA repair process. It can polymerize ADP-ribose units on its substrate proteins which are involved in the regulation of DNA repair. In this work, a novel series of para-substituted 1-benzyl-quinazoline-2, 4 (1H, 3H)-diones was designed and synthesized, and the inhibitory activities against PARP-1 of compounds 7a-7e, 8a-8f, 9a-9c and 10a-10c were evaluated. Of all the tested compounds, nine compounds displayed inhibitory activities with IC50 values ranging from 4.6 to 39.2 micromol x L(-1). In order to predict the binding modes of the potent molecules, molecular docking was performed using CDOCKER algorithm, and that will facilitate to further develop more potent PARP-1 inhibitors with a quinazolinedione scaffold.
Antineoplastic Agents
;
chemical synthesis
;
chemistry
;
pharmacology
;
Drug Design
;
Enzyme Inhibitors
;
chemical synthesis
;
chemistry
;
pharmacology
;
Molecular Docking Simulation
;
Molecular Structure
;
Poly (ADP-Ribose) Polymerase-1
;
Poly(ADP-ribose) Polymerases
;
Quinazolinones
;
chemical synthesis
;
chemistry
;
pharmacology
;
Structure-Activity Relationship
7.The Progress of Biological Research of Medicinal Fungus Shiraia bambusicola
Xiao-Ming JIA ; Xiao-Hong XU ; Bai-Chuan ZHUANG ; Hai-Ping LIN ;
Microbiology 1992;0(03):-
The research status is reviewed on taxonomic position, ecology, biological active matter and artificial cultivation of Shiraia bambusicola. Following problems are presented: whether there are new species and host specificity of Shiraia bambusicola. Since the artificial cultivation of stroma of Shiraia bambusicola has not been success, Shiraia bambusicola is in situation of emerge of itself and perish of itself so that it is not beneficial to resource protection and continual utilization of this medicinal fungus. It is pointed out that molecular biology of Shiraia bambusicola should be further researched and technology of artificial cultivation of Shiraia bambusicola should be explored in order to exploit and usage of Shiraia bambusicola.
8.Meta analysis of comparison of central corneal thickness measurement between Pentacam and A-scan in normal people
Shi-ming, CHENG ; Yan, LI ; Jin-hai, HUANG ; Xia, ZHOU ; Ling, XU
Chinese Journal of Experimental Ophthalmology 2013;(2):172-176
Background Central corneal thickness (CCT) is one of important parameters of the anterior eye segment.It plays a very important part in corneal refractive surgery and diagnosis of glaucoma.Contacted A-scan remains the gold standard for CCT measurement.Ophthalmologists are trying to look for a more convenient and noncontacted instrument to take place of contacted A-scan for CCT measurement.Objective This system analysis was to evaluate the difference between Pentacam and A-scan in CCT measurement.Methods A systematic literature retrieval was conducted from the MEDLINE,EMbase,Google Scholar,CBM disc and CNKI database with the limitation of publishing time from January 2005 to May 2011.The literature text was limited to the comparison of the CCT values measured by Pentacam and A-scan.The statistical analysis was performed using RevMan 5.1.0 software.Sensitive analysis was carried out and the publishing bias was analyzed using inverted funnel plot.Results A total of 26 studies met the requirement were included in this Meta-analysis with the 12 pieces of Chinese article and 14 pieces of English article,with the total eyes 3677.Heterogeneity was found anmong included studies (P =0.0003,I2 =56%) and random effects model was used.The differential value of CCT derived by Pentacam and A-scan was 1.74 μm,and no significant difference was found between Pentacam and A-scan (WMD =1.74,95% CI:-0.69-4.16,P>0.05).Fixed effects model was used to exclude the studies with the sample more than 100 eyes as the sensitive analysis.When fixed effect model was used,CCT by Pentacam was 2.73 μm more than A-scan,showing an insignificantly clinical difference.When studies with a sample more than 100 eyes were excluded,the CCT value by Pentacam was 2.64 μm more than A-scan,without clinically significant difference between them.No obvious publishing bias was seen in the included literature.Conclusions The difference between Pentacam and A-scan in CCT measurement is less and could be ignored.
9.Comparison of anterior segment measuring parameters in myopia after laser in situ keratomileusis between Sirius and Pentacam
Zhen, XU ; Jin-hai, HUANG ; Shi-ming, CHENG ; Yi-fan, FENG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2013;(6):572-577
Background Sirius system,a new Scheimpflug camera combined with Placido topography,improved the capability of imaging the anterior eye segment significantly.However,the study of assessing the repeatability and agreement between Sirius and Pentacam is still lack up to now.Objective This study was to evaluate the repeatability and agreement of the anterior ocular segment measuring parameters by Sirius and Pentacam in myopia received laser in situ keratomileusis (LASIK).Methods Thirty-five myopic eyes of 35 patients received LASIK were included in School of Optometry and Ophthalmology Eye Hospital from 2010 May through 2010 July.Corneal power flat keratometry (Kf),step keratometry (Ks),mean keratometry (Km),thinnest corneal thickness(TCT),the location of TCT,anterior chamber depth (ACD) and anterior chamber volume (ACV) were measured by Sirius and Pentacam in all the eyes,respectively.The repeatability of the measuring results were evaluated using intraclass correlation coefficients (ICC) and Cronbach's coefficient alpha (CoA),and the agreement of measuring parameters between Sirius and Pentacam was analyzed using Bland-Altman plot.Results Both Sirius and Pentacam demonstrated high intraobserver repeatability,with all ICC and CoA more than 0.90.No significant differences were found in Kf values and Ks values between the two methods (t =-1.533,-1.750,P>0.05).Km value was (39.14 ± 1.95) D by Sirius measurement,which was sígnificantly higher than (39.05 ± 1.91) D by Pentacam measurement (t =3.572,P =0.001).The TCT was (457.6 ± 40.9) μm by Sirius method,showing a significant reduce in comparison with (465.4±37.5) μm of Pentacam method (t =-6.689,P<0.001).A positive correlation was seen in the TCT between the two methods (r=0.988,P<0.001).The Bland-Alrman plots showed the 95% CI-21 μm to 6 pm in the TCT value between the two devices.Pairwise comparison of the location of TCT measurements showed significant differences between the two devices (t =-4.132,-5.696,P<0.001),with a good correlation (r=0.751,0.775) and the 95% CI (-0.36-0.17 mm,-0.35-0.12 mm).A very good agreement was seen in ACD between the two devices (-0.02-0.12 mm),but the agreement result was not very well in the ACV between the two devices with the 95% CI (-27.70-6.20 mm3).Conclusions Sirius and Pentacam measurements for anterior ocular segment parameters have a very good repeatability in post-LASIK eyes.In addition,good agreement results are exhibited in corneal power,TCT and ACD between Sirius and Pentacam with an acceptable maximal different value between them.Sirius and Pentacam can be used interchangeably in clinical examination.However,the two devices can not interchangeably for ACV measurement and TCT location.
10.Correlation between low tube voltage in dual source CT coronary artery imaging with image quality and radiation dose.
Zi-Qiao, LEI ; Ping, HAN ; Hai-Bo, XU ; Jian-Ming, YU ; Hong-Li, LIU
Journal of Huazhong University of Science and Technology (Medical Sciences) 2014;34(4):616-20
The influence of low tube voltage in dual source CT (DSCT) coronary artery imaging on image quality and radiation dose and its application value in clinical practice were investigated. Totally, 300 cases of chest pain with low body mass index (BMI <18.5 kg/m(2)) subjected to DSCT coronary artery imaging were prospectively enrolled. The heart rate in all patients were greater than 65/min. The retrospective ECG gated scanning mode and simple random sampling method were used to assign the patients into groups A, B and C (n=100 each). The patients in groups A, B and C experienced 120-, 100-, and 80-kV tube voltage imaging respectively, and the image quality was evaluated. The CT volume dose index (CTDIvol) and dose length product (DLP) were recorded, and the effective dose (ED) was calculated in each group. The image quality scores and radiation doses in groups were compared, and the influence of tube voltage on image quality and radiation dose was analyzed. The results showed that the excellent rate of image quality in groups A, B and C was 95.69%, 94.72% and 96.33% respectively with the difference being not statistically significant among the three groups (P>0.05). The CTDIvol values in groups A, B and C were 51.35±12.21, 21.28±7.13 and 6.34±3.34 mGy, respectively, with the difference being statistically significant (P<0.05). The ED values in groups A, B and C were 9.27±1.63, 4.56±2.29 and 2.29±1.69 mSv, respectively, with the difference being statistically significant (P<0.05). It was suggested that for the patients with low BMI, the application of DSCT coronary artery imaging with low tube voltage can obtain satisfactory image quality, and simultaneously, significantly reduce the radiation dose.