2.Relation Between Hemoglobin and Blood Pressure
Hai-Lan ZHONG ; Xin-Zheng LU ; Xiu-Mei CHEN ; Xiao-Hui YANG ; Hai-Feng ZHANG ; Ke-Jiang CAO ; Jun HUANG ;
Chinese Journal of Hypertension 2006;0(12):-
Objective To study the relationship between peripheral blood hemoglobin (HB) and blood pres- sure.Methods We performed a cross-sectional analysis in 1153 subjects aged 29-83 years.Waist circumfer- ence,HB,blood pressure,high-density lipoprotein cholesterol(HDL-C),low-density lipoprotein cholesterol(LDL- C),triglycerides (TG),total cholesterol (TC) were determined.Results ①With the increasing of blood pres- sure,HB had a clearly increasing trend (HB,normotensive:137.5?14.7 vs prehypertension:143.4?14.4 vs hy- pertension:144.3?13.8 g/L,P
4.Effects of selective head cooling on cerebral blood flow and cerebral metabolic rate in newborn piglets.
Guo-qiang CHENG ; Xiao-mei SHAO ; Hai-mei HUANG
Chinese Journal of Pediatrics 2005;43(10):748-752
OBJECTIVETo study the change in regulation of cerebral blood flow (CBF) and cerebral metabolism rate (CMR) during selective head cooling (SHC) in newborn piglets.
METHODSSixteen newborn piglets, aged 5 approximately 7 days, were randomly assigned to one of the following three groups: SHC in normal piglets (n = 4), SHC after hypoxia-ischemia HI (n = 6) and normal temperature after HI (n = 6). Nasopharyngeal temperature was respectively reduced to 35 degrees C and then 32 degrees C in SHC group. HI was induced by using temporary occlusion of the bilateral carotid arteries and mechanical ventilation with low concentration of oxygen (6%) for 30 minutes. CBF was measured with color microspheres method. Mixed venous blood and arterial sample were collected at the same time from superior sagittal sinus and forelimb artery respectively for blood gas analysis, blood glucose and lactate measurement. Cerebral oxygenation metabolism rate (CMRO(2)), cerebral glucose metabolism rate (CMR(Glu)) and cerebral lactate production (CLP) were calculated.
RESULTSIn normal piglets, CBF, CMRO(2) and CMR(Glu) were significantly decreased at 35 degrees C and 32 degrees C respectively, while CLP did not change. When nasopharyngeal temperature decreased to 35 degrees C, The ratios of CBF/CMRO(2), CBF/CMR(Glu) and CBF/CLP did not significantly change, coupling of CBF and CMR was maintained. While nasopharyngeal temperature decreased to 32 degrees C, the ratios of CBF/CMR(Glu) and CBF/CLP significantly decreased. Maintained newborn piglets normal temperature after HI, the CBF and CMRO(2) were significantly reduced, while CMR(Glu) and CLP were markedly increased. The ratio of CBF/CMRO(2) increased, CBF/CMR(Glu) and CBF/CLP decreased. Uncoupling of CBF and CMR was observed. During SHC after HI, the same decrease was observed in CBF and CMR(Glu) and CLP was markedly reduced. The ratio of CBF/CMRO(2), CBF/CMR(Glu) and CBF/CLP were restored at 35 degrees C and 32 degrees C as compared to the same time point in normal temperature, respectively.
CONCLUSIONCBF and CMR decreased in normal piglets during SHC and coupling of CBF and CMR was maintained. After HI, CBF was reduced and the disturbance of cerebral oxygenation metabolism occurred. CBF and CMR was uncoupled. SHC after HI can improve CMR and correct uncoupling of CBF and CMR.
Animals ; Animals, Newborn ; metabolism ; Blood Glucose ; Brain ; blood supply ; metabolism ; Cerebrovascular Circulation ; Cold Temperature ; Hypothermia, Induced ; Hypoxia-Ischemia, Brain ; metabolism ; Lactic Acid ; blood ; Oxygen Consumption ; Swine ; metabolism
5.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
6.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
7.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.
8.Evaluation of binocular minimum thickness of cornea in Chinese myopic population
Xiao-min, WU ; Si-si, CHEN ; Rong-rong, GAO ; Qin-mei, WANG ; Jin-hai, HUANG
Chinese Journal of Experimental Ophthalmology 2012;(11):1018-1021
Background Central corneal thickness (CCT)is an important parameter to evaluate corneal healthy status and is crucial for surgical planning.However,clinical study found that the center of cornea does not correspond to the thinnest point of cornea.Thus,it is essential to characterize the minimum corneal thickness(MCT) and its location.Objective Present study was to determine the thickness and location of MCT and its relationship to the fellow eye using Pentacam High Resolution technique.Methods The 564 eyes from 282 Chinese myopic patients were reviewed in this study.The CCT,MCT,pupillary central corneal thickness(PCT) and x-y coordinate of thinnest point were bilaterally measured.Written informed consent was obtained prior to the ocular biomedical measurement.Results CCT was (540.07±31.78) μm in the right eyes and (539.24±31.06) μm in the lefi eyes; PCT was (540.25±30.75)μm in the right eyes and (539.48±31.00)μm in the left eyes.MCT was (537.87± 31.91)μm in the right eyes and (536.35±31.24)μm in the left eyes,showing significant differences in all the parameters between the right eyes and left eyes expect for PCT(CCT:P=0.046;PCT:P=0.065 ;MCT:P=0.000).The C CT,PCT and M CT were significantly correlated between the right eyes and left eyes (r =0.97,0.97,0.98,P< 0.01).Bland-Altman plot showed a good consistence between the both eyes.The mean distance from the center was (0.50±0.21) mm in the right eyes and (0.56±0.22)mm in the left eyes,showing a significant difference (P =0.000).The difference between CCT and MCT was approximately (2.20±1.74)μm in the right eyes and (2.88±1.75) μm in the left eyes.The location of MCT in both the right eyes and left eyes tended to symmetry along the vertical midline.The distance between the R (x,y) to transformed L (x,y) was (0.29 ± 0.17)mm and the angular distance was (28.28±28.21)degree.Conclusions This study offers a range of MCT and its location in Chinese myopic patients.The difference exists between the CCT and MCT in bilateral eyes.The location of the thinnest point tends to be symmetrical along the vertical midline between the both eyes.The changes of these parameters may be helpful for the diagnosis of some corneal diseases.
9.Repeatability and accuracy of corneal parameters measured by RTVue Fourier-domain optical coherence topography
Yan-jun, HUA ; Jin-hai, HUANG ; Chao, PAN ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2013;(2):177-181
Background Corneal parameters (such as curvature,thickness,etc) are essential to the diagnosis of corneal related diseases,contact lenses fitting and corneal refractive surgery.Objective The aim of this study was to assess the repeatability and accuracy of corneal parameters obtained by RTVue Fourier-domain optical coherence topography (FD-OCT).Methods In this prospective study,77 eyes of 43 subjects with the refraction from-1.25 D to-10.00 D and astigmatism <2 D were enrolled in keratorefractive surgery center,Eye Hospital of Wenzhou Medical College.The anterior and posterior corneal curvature in 3 mm central zone (Ranterior and Rposterior),the ratio of posterior and anterior curvature (Rposterior/Ranterior),corneal central thickness (CCT),total corneal power(Knet),the simulated corneal power (Sim K),the anterior and posterior corneal power (Kanterior,Kposterior)were measured by FD-OCT.Corneal power (Km) was obtained by Topolyzer topography based on Placido ring.Three consecutive scans were acquired in every tested eye.Repeatability of FD-OCT measurement was assessed using the coefficient of variation CV),Cronbach Alpha and intra-class correlation coefficient (ICC).Repeated measure ANOVA was used to analyze the differences among SimK,Knet and Km.Pearson correlation analysis was used to analysis the correlation between SimK and K Knet and Km,SimK and Km.The agreement between Sim K and K Knet and Km,SimK and Km was assessed by Bland-Altman plots analysis.All the subjects understood the purpose of this investigation and written informed consent was obtained prior to the medical examination.Results The Ranterior,Rposterior,Rposterior/Ranterior,Kanterior,Kposterior,Sim K,Knet and CCT were (7.691 ±0.302) mm,(6.532±0.276) mm,0.849±0.014,(48.97±1.92)D,(-6.13±0.26)D,(43.95±1.72) D,(42.95±1.68) D and (545.20± 35.04) μm,respectively.The CV of all parameters was less than 1%.The Cronbach Alpha and ICC were both more than 0.9 except 0.802(ICC)of the Rposterior/Ranterior.SimK was (0.27±0.34) D higher than Km,and Knet was (0.73±0.37) D lower than Km.SimK was (1.01 ±0.11) D higher than K and all the differences showed a statistical significance (P<0.001).There were close positive correlations between SimK and Km,Knet and Km,SimK and Knet(all r ≥ 0.976,P<0.001).The Bland-Altman analysis showed a poor agreement between SimK and Km,Knet and Km,SimK and Knet.Conclusions The RTVue FD-OCT measuring corneal curvature and CCT performes good repeatability.The Sim K obtained by RTVue FD-OCT is slightly greater than that obtained by corneal topography,and the Rposterior/Ranterior obtained by RTVue FD-OCT is slightly lower than that from Gullstrand model eye.These results offer a basis for establishing a more accurate standardized model eye.
10.Study on intra-retinal layers imaged with ultra - high resolution optical coherence tomography
Su-Zhong, XU ; Sheng-Hai, HUANG ; Qing-Kai, MA ; De-Xi, ZHU ; Mei-Xiao, SHEN
International Eye Science 2014;(8):1494-1497
To evaluate the automated segmentation algorithm for detection of intra - retinal layers to process images obtained from ultra- high resolution optical coherence tomography ( OCT ) . Graph theory and the shortest path search based on dynamic programming were applied to automatically segment the 8 intra - retinal layers. We experimentally verified the accuracy and reliability of the algorithm. The results showed that the intra-retinal layer boundaries between automated and manual segmentations matched well. The algorithm successfully segmented the intra- retinal layers in glaucoma, high myopia, and retinitis pigmentosa patients. The proposed automatic segmentation for intra-retinal layers provides a promising tool for quantitative analysis in clinical diagnosis and treatment.