1.Analysis of the pollution status of paralytic shellfish poisons in shellfish sold in Hainan Province, 2018-2021
LI Cheng ; XIAO Wen-lin ; YE Hai-mei ; LAI Xuan-cheng ; SHI Hui ; HE Chang-hua
China Tropical Medicine 2023;23(5):484-
Abstract: Objective To investigate the pollution of paralytic shellfish poisons (PSP) in shellfish sold in Hainan Province from 2018 to 2021. Methods From 2018 to 2021, the content of 10 paralytic shellfish poisons including saxitoxin (STX), neosaxitoxin (neoSTX), gonyautoxins 1 (GTX1), gonyautoxins 2 (GTX2), gonyautoxins 3 (GTX3), gonyautoxins 4 (GTX4), gonyautoxins 5 (GTX5), decarbamoylsaxitoxin (dcSTX), decarbamoylgonyau toxins 2 (dcGTX2) and decarbamoylgonyau toxins 3 (dcGTX3) in 7 kinds of shellfish commonly sold in 13 cities and counties in Hainan province was analyzed. Results The detection rate of PSP in 360 shellfish samples was 10.3%. Among them, the highest detection rate of STX was 5.83%, followed by GTX2 detection rate of 4.17%; the detection rate of neoSTX and GTX3 were both 1.67%; the detection rate of GTX1 was 1.39%. None of the five PSP, GTX4, GTX5, dcSTX, dcGTX2 and dcGTX3, were detected. Four types of PSP were detected in fanscallops, two were detected in oysters, mussels and Scapharca subcrenata, only one was detected in scallops, and no toxin contamination was detected in clams and razor clams. A single sample of fanscallops detected a maximum of 4 PSP, and a single sample of oysters, scallops, mussels and Scapharca subcrenata detected a maximum of 1 PSP. The equivalence of PSP in all samples was ND-155.6 μg/kg.The annual detection rate of PSP from high to low was: 20.0% in 2020, 15.6% in 2019, 5.3% in 2018, and 2.0% in 2021, and none of the samples tested exceeded the standard. Continuously detectable STX in 2018-2020, all PSP that could be detected in 2018 were STX. In 2019, in addition to STX detected in scallops and Scapharca subcrenata, neoSTX was also detected in oysters, mussels and Scapharca subcrenata. In 2020, PSP was only detected from scallops, and GTX2 could be detected in all positive specimens, while 5 STX, 5 GTX1 and 6 GTX3 were detected. Only GTX2 detected from scallops in 2021. STX was detected in shellfish sold in 12 cities and counties, GTX2 can be detected in 10 cities and counties, neoSTX can be detected in 5 cities and counties, GTX1 and GTX2 were detected in 4 cities and counties respectively. Shellfish sold in Wenchang and Lingshui markets can detect 5 types of PSP. Conclusion Some types of shellfish on the market in Hainan are contaminated with some kind of PSP pollution risks, and it is necessary to strengthen the supervision of PSP in marketed shellfish.
2.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
3.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
4.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.
5.The protective effect of Yuyin Ruangan Decoction on experimental hepatic injury.
Zhi-wang WANG ; Xue-feng LU ; Hai-yan TUO ; Xiao-li CHENG ; Mei GUO
Chinese Journal of Applied Physiology 2015;31(1):76-79
OBJECTIVETo investigate the protective effects of Yuyin Ruangan Decoction(YRD, traditional Chinese medicine) on experimental hepatic injury in mice.
METHODSThe mice were randomly divided into control group, model group and YRD low, middle and high dose group(n = 11). By ip injection of D-GalN, CCk or thioacetamide (TAA), three models of hepatic injury mice were established to investigate the effects of YRD through detecting the indexes of liver function in serum and, the content of antioxidant system in the hepatic tissue.
RESULTSYRD could decrease the content of alanine aminotransferase (ALT)and aspartate aminotransferase (AST) in serum and that of malonaldehyde (MDA) in the hepatic tissue, upregulate the activity of superoxide dismutase (SOD) and glutathione peroxidase (GSH-Px) in the hepatic tissue. Furthermore, the above effects were dosedependent in a certain degree. CoNCLUSION: YRD has some protection effects on the model of experimental hepatic injury in mouse.
Alanine Transaminase ; blood ; Animals ; Antioxidants ; metabolism ; Aspartate Aminotransferases ; blood ; Chemical and Drug Induced Liver Injury ; drug therapy ; Drugs, Chinese Herbal ; pharmacology ; Glutathione Peroxidase ; metabolism ; Liver ; drug effects ; enzymology ; Malondialdehyde ; metabolism ; Mice ; Superoxide Dismutase ; metabolism
6.Comparison of anterior segment measuring parameters in myopia after laser in situ keratomileusis between Sirius and Pentacam
Zhen, XU ; Jin-hai, HUANG ; Shi-ming, CHENG ; Yi-fan, FENG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2013;(6):572-577
Background Sirius system,a new Scheimpflug camera combined with Placido topography,improved the capability of imaging the anterior eye segment significantly.However,the study of assessing the repeatability and agreement between Sirius and Pentacam is still lack up to now.Objective This study was to evaluate the repeatability and agreement of the anterior ocular segment measuring parameters by Sirius and Pentacam in myopia received laser in situ keratomileusis (LASIK).Methods Thirty-five myopic eyes of 35 patients received LASIK were included in School of Optometry and Ophthalmology Eye Hospital from 2010 May through 2010 July.Corneal power flat keratometry (Kf),step keratometry (Ks),mean keratometry (Km),thinnest corneal thickness(TCT),the location of TCT,anterior chamber depth (ACD) and anterior chamber volume (ACV) were measured by Sirius and Pentacam in all the eyes,respectively.The repeatability of the measuring results were evaluated using intraclass correlation coefficients (ICC) and Cronbach's coefficient alpha (CoA),and the agreement of measuring parameters between Sirius and Pentacam was analyzed using Bland-Altman plot.Results Both Sirius and Pentacam demonstrated high intraobserver repeatability,with all ICC and CoA more than 0.90.No significant differences were found in Kf values and Ks values between the two methods (t =-1.533,-1.750,P>0.05).Km value was (39.14 ± 1.95) D by Sirius measurement,which was sígnificantly higher than (39.05 ± 1.91) D by Pentacam measurement (t =3.572,P =0.001).The TCT was (457.6 ± 40.9) μm by Sirius method,showing a significant reduce in comparison with (465.4±37.5) μm of Pentacam method (t =-6.689,P<0.001).A positive correlation was seen in the TCT between the two methods (r=0.988,P<0.001).The Bland-Alrman plots showed the 95% CI-21 μm to 6 pm in the TCT value between the two devices.Pairwise comparison of the location of TCT measurements showed significant differences between the two devices (t =-4.132,-5.696,P<0.001),with a good correlation (r=0.751,0.775) and the 95% CI (-0.36-0.17 mm,-0.35-0.12 mm).A very good agreement was seen in ACD between the two devices (-0.02-0.12 mm),but the agreement result was not very well in the ACV between the two devices with the 95% CI (-27.70-6.20 mm3).Conclusions Sirius and Pentacam measurements for anterior ocular segment parameters have a very good repeatability in post-LASIK eyes.In addition,good agreement results are exhibited in corneal power,TCT and ACD between Sirius and Pentacam with an acceptable maximal different value between them.Sirius and Pentacam can be used interchangeably in clinical examination.However,the two devices can not interchangeably for ACV measurement and TCT location.
7.Prevalence and prevention and control effects of malaria in Huangshi, Hubei, 1951-2021
QIAN Zu-shu ; ZHAO Ke-ti ; ZHANG Cheng ; LI Ai-mei ; YAO Hai-yan
China Tropical Medicine 2023;23(4):383-
Abstract: Objective To analyze the epidemiological characteristics, prevention and control strategies, measures and the effects achieved of malaria in Huangshi City from 1951 to 2021, and to offer a reference for further strengthening malaria eradication and control successes. Methods Descriptive epidemiological methods were used to assess the prevalence, measurements, and impacts of malaria in different time periods based on data for malaria control in Huangshi City from 1951 to 2021, and we created "semi-log" line graphs and charts to display the prevalence of disease and the effort done in prior years in terms of prevention and control. Results Between 1951 and 2021, 527 780 cases of malaria were recorded in Huangshi, with an average annual incidence rate of 40.07/10 000. The prevention and control of malaria has gone through four stages, namely, the high prevalence of malaria stage (1951-1979), the basic elimination stage (1980-1999), the consolidation stage (2000-2010), and the eradication stage (2011-2021). Different strategies and measures have been adopted in different epidemic periods. During the high epidemic period, great efforts have been made to carry out general surveys and treatments, and strengthen the management of symptomatic patients; during the eradication stage, prominent and classified prevention and control strategies were adopted. When the incidence rate dropped to below 1/10 000, the main measures adopted were malaria monitoring, including timely discovery and standardization of infectious sources, disposal of epidemic points, management of migrant population malaria and vector monitoring. Through active prevention and control, remarkable results were achieved, and the incidence rate of malaria fell to below 1/10 000 in 1989, reaching the level of "basic elimination of malaria" issued by the Ministry in 1999, and passed the provincial malaria elimination acceptance in 2015. In recent years, with the increasing labor exports and foreign exchanges, imported malaria has been on the rise. African countries are the main sources of imported malaria, and the main species is P.falciparum. Conclusions Malaria was once one of the main infectious diseases endangering the health of people in Huangshi City. The preventive and control methods and procedures adopted in different epidemic periods are effective. Currently, we have entered the consolidation phase of malaria elimination, with the focus of work being to monitor, report, and timely and effectively respond to imported malaria cases, thus reducing the risk of local transmission.
8.Effects of selective head cooling on cerebral blood flow and cerebral metabolic rate in newborn piglets.
Guo-qiang CHENG ; Xiao-mei SHAO ; Hai-mei HUANG
Chinese Journal of Pediatrics 2005;43(10):748-752
OBJECTIVETo study the change in regulation of cerebral blood flow (CBF) and cerebral metabolism rate (CMR) during selective head cooling (SHC) in newborn piglets.
METHODSSixteen newborn piglets, aged 5 approximately 7 days, were randomly assigned to one of the following three groups: SHC in normal piglets (n = 4), SHC after hypoxia-ischemia HI (n = 6) and normal temperature after HI (n = 6). Nasopharyngeal temperature was respectively reduced to 35 degrees C and then 32 degrees C in SHC group. HI was induced by using temporary occlusion of the bilateral carotid arteries and mechanical ventilation with low concentration of oxygen (6%) for 30 minutes. CBF was measured with color microspheres method. Mixed venous blood and arterial sample were collected at the same time from superior sagittal sinus and forelimb artery respectively for blood gas analysis, blood glucose and lactate measurement. Cerebral oxygenation metabolism rate (CMRO(2)), cerebral glucose metabolism rate (CMR(Glu)) and cerebral lactate production (CLP) were calculated.
RESULTSIn normal piglets, CBF, CMRO(2) and CMR(Glu) were significantly decreased at 35 degrees C and 32 degrees C respectively, while CLP did not change. When nasopharyngeal temperature decreased to 35 degrees C, The ratios of CBF/CMRO(2), CBF/CMR(Glu) and CBF/CLP did not significantly change, coupling of CBF and CMR was maintained. While nasopharyngeal temperature decreased to 32 degrees C, the ratios of CBF/CMR(Glu) and CBF/CLP significantly decreased. Maintained newborn piglets normal temperature after HI, the CBF and CMRO(2) were significantly reduced, while CMR(Glu) and CLP were markedly increased. The ratio of CBF/CMRO(2) increased, CBF/CMR(Glu) and CBF/CLP decreased. Uncoupling of CBF and CMR was observed. During SHC after HI, the same decrease was observed in CBF and CMR(Glu) and CLP was markedly reduced. The ratio of CBF/CMRO(2), CBF/CMR(Glu) and CBF/CLP were restored at 35 degrees C and 32 degrees C as compared to the same time point in normal temperature, respectively.
CONCLUSIONCBF and CMR decreased in normal piglets during SHC and coupling of CBF and CMR was maintained. After HI, CBF was reduced and the disturbance of cerebral oxygenation metabolism occurred. CBF and CMR was uncoupled. SHC after HI can improve CMR and correct uncoupling of CBF and CMR.
Animals ; Animals, Newborn ; metabolism ; Blood Glucose ; Brain ; blood supply ; metabolism ; Cerebrovascular Circulation ; Cold Temperature ; Hypothermia, Induced ; Hypoxia-Ischemia, Brain ; metabolism ; Lactic Acid ; blood ; Oxygen Consumption ; Swine ; metabolism
9.Effects of storage time on quality of Desmodium styracifolium seeds.
Quan YANG ; Xiao-min TANG ; Hai-yun PAN ; Ling-feng MEI ; Chun-rong ZHANG ; Xuan-xuan CHENG ; Lu-qi HUANG
China Journal of Chinese Materia Medica 2015;40(20):3953-3957
The dynamic changes of germination percentage, germination potential, thousand-seed weight, antioxidase activity in Desmodium styracifolium seeds with different storage time were tested, and electrical conductivity, contents of soluble sugar, soluble protein, starch in seed leach liquor were also determined in order to reveal the mechanism of seed deterioration. The results as the following. (1) The germination percentage, germination potential and thousand-seed weight of D. styracifolium seeds declined, while the seed coat color darkened with the extension of storage time. (2) The activities of superoxide dismutase (SOD) and peroxidase (POD) decreased with the prolongation of storage period. The SOD activity declined fastest in 1,095-1,185 d of storage, while the POD activity declined significantly in 365-395 d of storage. (3) The electrical conductivity and the contents of soluble sugar, starch in seed leach liquor increased, while the content of soluble protein declined with the extension of storage time. (4) Correlation analysis indicated that the germination percentage, germination potential and thousand-seed weight of D. styracifolium seeds have a significantly positive correlation with SOD and POD activity, while have a significantly negative correlation with the electrical conductivity, contents of soluble sugar and starch. It can be concluded that during the storage of D. styracifolium seeds, physiological and biochemical changes including decrease in antioxidase activity, rise in electrical conductivity, degradation effluent of soluble sugar and starch, degradation of soluble protein were the main factors leading to the seed deterioration.
Color
;
Fabaceae
;
chemistry
;
enzymology
;
growth & development
;
metabolism
;
Germination
;
Peroxidases
;
metabolism
;
Plant Proteins
;
metabolism
;
Seeds
;
chemistry
;
enzymology
;
growth & development
;
metabolism
;
Starch
;
metabolism
;
Superoxide Dismutase
;
metabolism
;
Time Factors
10.Effects of nitrogen form on growth and quality of Chrysanthemums morifolium.
Peng ZHANG ; Kang-cai WANG ; Ming-chao CHENG ; Qing-hai GUO ; Jie ZHAO ; Xiu-Mei ZHAO ; Li LI
China Journal of Chinese Materia Medica 2014;39(17):3263-3268
This paper is aimed to study the effects of nitrogen form on the growth and quality of Chrysanthemums morifolium at the same nitrogen level. In order to provide references for nutrition regulation of Ch. morifolium in field production, pot experiments were carried out in the greenhouse at experimental station of Nanjing Agricultural University. Five proportions of ammonium and nitrate nitrogen were set up and a randomized block design was applied four times repeatedly. The results showed that the growth and quality of Ch. morifolium were significantly influenced by the nitrogen form. The content of chlorophyll and photosynthesis rate were the highest at the NH4(+) -N /NO3(-) -N ratio of 25:75; The activities of NR in different parts of Ch. -morifolium reached the highest at the NH4(+) - N/NO3(-) -N ratio of 0: 100. The contents of nitrate nitrogen in the root and leaves reached the highest at the NH4(+) -N/NO3(-) -N ratio of 50:50. The activities of GS, GOGAT and the content of amylum increased with the ratio of NO3(-) -N decreasing and reached it's maximum at the NH4 + -N/NO3 - -N ratio of 100: 0. The content of ammonium nitrogen were the highest at the NH4 + -N /NO3 --N ratio of 75: 25, while the content of soluble sugar reached the highest at the NH4(+)-N/NO3(-) -N ratio of 25: 75. The content of flavones, chlorogenic acid and 3,5-O-dicoffeoylqunic acid were 57.2 mg x g(-1), 0.673% and 1.838% respectively, reaching the maximum at the NH4(+) -N /NO3(-) -N ratio of 25:75; The content of luteoloside increased with the ratio of NO3(-) -N increasing and reached it's maximum at the NH4(+) -N/NO3(-) -N ratio of 0: 100. The yield of Ch. morifolium reached it's maximum at the NH4(+) -N /NO3(-) -N ratio of 25:75. Nitrogen form has some remarkable influence on the nitrogen metabolism, photosynthesis and growth, Nitrogen form conducive to the growth and quality of Ch. morifolium at the NH4(+) -N /NO3(-) -N ratio of 25: 75.
Ammonium Compounds
;
metabolism
;
pharmacology
;
Chlorophyll
;
metabolism
;
Chrysanthemum
;
drug effects
;
growth & development
;
metabolism
;
Flowers
;
drug effects
;
growth & development
;
metabolism
;
Glutamate Synthase
;
metabolism
;
Glutamate Synthase (NADH)
;
metabolism
;
Glutamate-Ammonia Ligase
;
Nitrates
;
metabolism
;
pharmacology
;
Nitrogen
;
metabolism
;
pharmacology
;
Photosynthesis
;
drug effects
;
Plant Leaves
;
drug effects
;
growth & development
;
metabolism
;
Plant Proteins
;
metabolism
;
Plant Roots
;
drug effects
;
growth & development
;
metabolism
;
Plant Stems
;
drug effects
;
growth & development
;
metabolism