2.Research progress on MAPK signal pathway in the pathogenesis of osteoarthritis.
Shi-Chao GAO ; Hai-Bo YIN ; Hong-Xiao LIU ; Yun-Hui SUI
China Journal of Orthopaedics and Traumatology 2014;27(5):441-444
Mitogen-activated protein kinases (MAPKs) signal is one of the important ways in eukaryotic cell,which adjusts and controls the structure and function of the cell. MAPKs in eukaryotes include p38, ERK, JNK and ERK5, etc. With the deepening research,we found that the activation of p38, ERK, JNK signal pathways were closely related with osteoarthritis (OA) cartilage injury. MAPKs are the key signaling systems involved in the production of matrix metalloproteinases and the regulation of cartilage cell proliferation, apoptosis and differentiation. Expecially the matrix metalloproteinases can accelerate the degradation of articular cartilage. So it has been the new spot in pathogenesis of osteoarthritis study.
Animals
;
Cartilage, Articular
;
pathology
;
Humans
;
MAP Kinase Signaling System
;
Mitogen-Activated Protein Kinases
;
metabolism
;
Osteoarthritis
;
etiology
;
pathology
3.Pyoderma gangrenosum associated with ulcerative colitis and psoriasis.
Hao GUO ; Lan ZHANG ; Qian AN ; Zhen-hai YANG ; Bo LI ; Xing-hua GAO ; Jiu-hong LI
Chinese Medical Journal 2013;126(9):1798-1798
4.Isolation and Identification on a Thermoacidophilic Fungus of High-producing Cellulase and the Characteristics of its Enzyme
Jian-Min GAO ; Hai-Bo WENG ; Yu XI ; Ming-Xue YUAN ; Shao-Yin HAN ;
Microbiology 1992;0(04):-
A novel Aspergillus terreus strain M11 was isolated from the compost containing cellulose and identified. The isolate grow best at 45℃ and pH2.0. It was found that the activity of the CMCase was up to 3.680IU/mL with high heat stability and the optimal reaction conditions of the CMCase were at 60℃ and pH2.0.
5.Study on the fit of titanium alloy removable partial denture framework fabricated by selective laser melting
Yifan LIU ; Weina WANG ; Hai YU ; Rui MA ; Bing WU ; Bo GAO
Journal of Practical Stomatology 2017;33(3):302-305
Objective:To evaluate the fit of titanium alloy removable partial denture framework fabricated by selective laser melting(SLM) technique.Methods:7 Kennedy Ⅲ Ti-6Al-4V removable titanium alloy partial denture frameworks were fabricated by SLM technology.An optical scanner was used to scan the gypsum model adhered with the silicone rubber film obtained by the impression method before and after removal of the film.Geomagic Qualify 2013 software was used to analyze the gap between the model and the tissue surface of the major connector of the framework,the fit of the frame work was evaluated.Results:The overall 3D deviation between the titanium alloy frameworks and the gypsum model was (0.221 9±0.07) mm.Conclusion:The fit of the titanium alloy removable partial denture framework made by SLM technology can basically met the clinical requirements.
6.An unusual case of cauliflower-like tumor of breast
Wang HAI-BO ; Zhu JIAN ; Tan ZHI-TIAN ; Gao XU-HUI
Chinese Medical Journal 2019;132(22):2767-2769
7.Detection of two viruses infecting Pinellia ternata in China.
Su-Su SHENTU ; Hai-li WANG ; Ji-shuang CHEN ; Yu-bo HE ; Bi-da GAO
China Journal of Chinese Materia Medica 2007;32(8):664-667
OBJECTIVETo study viruses infecting Pinellia ternata in China.
METHODSymptom observation, DAS-ELISA and RT-PCR detection were applied.
RESULT AND CONCLUSIONDuring a survey in early spring, SMV and CMV were both commonly distributed as main viruses infecting P. ternata collected from different areas in China. But DsMV was the virus which infected P. ternate in natural condition. The infection ratio of cultivated P. ternate by SMV and CMV were 71.4% and 14.3% respectively for 21 samples collected from Ningbo, Zhejiang province; 100% and 44.4% for 18 samples from Xiaoshan, Zhejiang province; 61.9% and 33.3% for 21 samples from Hebei province; 50.0% and 41.7% for 12 samples from Anhui province; 16.7% and 16.7% for 12 samples from Sichuan province; 31.3% and none for 16 samples from Beijing. And the infection ratio of 25 wild samples from different areas of China infected by SMV and CMV were both 20.0%.
China ; Cluster Analysis ; Cucumovirus ; genetics ; isolation & purification ; DNA, Complementary ; chemistry ; genetics ; Mosaic Viruses ; classification ; genetics ; isolation & purification ; Pinellia ; virology ; Plant Diseases ; virology ; Plants, Medicinal ; virology ; Sequence Analysis, DNA
8.Transurethral resection of the prostate combined with 2-micron continuous-wave laser vaporesection for benign prostatic hyperplasia with the prostate volume > 80 ml.
Xiao-lei REN ; Zhi-ming GAO ; Hai-bo XIA ; Guo-chang BAO ; Chun-sheng LI ; Hao ZHANG
National Journal of Andrology 2015;21(2):136-139
OBJECTIVETo sum up the clinical experience in the management of benign prostatic hyperplasia (BPH) with the prostate weighing over 80 ml by transurethral resection of the prostate (TURP) combined with 2 μm continuous-wave laser vaporesection (LVR).
METHODSWe retrospectively analyzed the clinical effects of TURP combined with 2 μm LVR in the treatment of 46 cases of BPH with the prostate volume > 80 ml.
RESULTSAll the operations were successfully accomplished. The operation time and intraoperative blood loss were (112.0 ± 20.0) min (range 86-176 min) and (77.9 ± 25.9) ml (range 50-200 ml), respectively. The catheters were withdrawn at 7 days after surgery. Transient urinary incontinence occurred in 6 cases and secondary hemorrhage was found in 2 postoperatively. Six-month follow-up revealed no urethral stricture or other complications. Compared with the baseline, the international prostate symptom score (IPSS) was significantly decreased at 6 months after operation (26.3 ± 1.8 vs 11.6 ± 1.7, P <0.05), and so were the quality of life (QOL) score (5.3 ± 0.7 vs 1.3 ± 1.1, P <0.05) and post-void residual urine (PVR) ([115.5 ± 55.6] ml vs [19.9 ± 11.6] ml, P <0.05). However, the maximum urinary flow rate (Qmax) was remarkably increased from (4.1 ± 2.6) ml/s to (16.2 ± 1.7) ml/s (P <0.05).
CONCLUSIONTURP combined with 2 μm LVR is safe and effective for the treatment of BPH with the prostate volume >80 ml.
Aged ; Blood Loss, Surgical ; Humans ; Laser Therapy ; methods ; Male ; Middle Aged ; Organ Size ; Prostate ; pathology ; Prostatic Hyperplasia ; pathology ; surgery ; Quality of Life ; Retrospective Studies ; Transurethral Resection of Prostate ; methods ; Treatment Outcome ; Urethral Stricture ; Urinary Incontinence ; etiology ; Urinary Retention
9.Measurement of systolic/diastolic function in isolated ventricular myocytes by video-based motion edge-detection system.
Hai-Feng ZHANG ; Bo ZHANG ; Xiao-Dong ZHANG ; Feng GAO
Chinese Journal of Applied Physiology 2004;20(4):410-414
AIMSingle cardiomyocytes were isolated from adult rat hearts and myocyte contraction was recorded by a video-based motion edge-detection system.
METHODSSingle ventricular myocytes were enzymatically isolated, loaded with fura-2/AM (0.5 micromol/L) for 30 min in dark at room temperature and field-stimulated (0.5 Hz, 5 ms), and both myocyte contraction and intracellular fluorescence intensity were simultaneously assessed by a video-based motion edge-detection system.
RESULTSUsing the video-based motion edge-detection system, one may real-time beat-to-beat observe and record the amplitude, duration and velocity of both myocyte shortening/ relengthening and intracellular calcium transient, and then directly describe the change of isolated ventricular myocyte mechanics.
CONCLUSIONDirect measurement of isolated ventricular myocyte mechanics using the video-based motion edge-detection system is an increasingly important technique in cardiac physiology that provides fundamental information on myogenic and excitation-contraction coupling of the heart in drug intervention and gene manipulation.
Animals ; Calcium ; metabolism ; Cells, Cultured ; Cytological Techniques ; Heart Ventricles ; cytology ; Myocardial Contraction ; Myocytes, Cardiac ; physiology ; Rats ; Rats, Sprague-Dawley ; Single-Cell Analysis ; Video Recording ; instrumentation
10.Repeatability and reproducibility of retinal straylight measurement using C-Quant compensation comparison method
Jin-hai, HUANG ; Shi-shi, LIN ; Qin-mei, WANG ; Bo, ZHENG ; Si-si, CHEN ; Rong-rong, GAO
Chinese Journal of Experimental Ophthalmology 2012;30(2):160-163
BackgroundIn an ideal eye there would be no light scattering at all,but the eye media is not optically ideal.Intraocular straylight causes a veil of light and reduction in the contrast of the retinal image and thus decrease the quality of vision.ObjectiveThe present study was to investigate the repeatability and reproducibility of C-Quant straylight meter( Oculus,Germany)in measuring retinal straylight of myopia and post-laser in situ keratomileusis(LASIK) corneas.MethodsThis is a prospective research.The consecutive 35 eyes of 21 myopic patients and 34 eyes of 22 patients who received LASIK were included in this trail.Retinal straylight was measured for 7 times at a period of time and analyzed quantificational to evaluate the repeatability of measurement.Thirty-eight eyes of 19 patients were measured again at 3-7 days for 3 times at a period of time to assess the reproducibility of C-Quant straylight meter.The mean standard difference (SD) and coefficient of variation (CV) were used as the credibility evaluation.This clinical study complied with Helsinki Declaration and the informed consent was obtained prior to the medical procedure.ResultsThe straylight Log(s) of 7 times measurement were all less than 0.95.The mean Log(s) were 0.92±0.12 and 0.93±0.17 respectively in myopia group and post-LASIK group,without statistically significant differences among 7 times measurement( F=0.335,P=0.812;F=1.000,P=0.409).The mean SD for the 7 times measurement was 0.07 Log units.SD and CV increased with the number of measurements.The differences of mean SD and CV between 3 times result and 6 times result were significant different (t =-2.080,P =0.045;t =-2.190,P =0.035 ).No difference was found between different time periods( t =-0.531,P=0.598 ).The difference of the results between two measurements from the same patient was 0.013.ConclusionsC-Quant is a noncontact,noninvade,rapid and convenient method for the measurement of straylight in myopia and post-LASIK eyes due to the high repeatability and reproducibility.