2.Evaluation of binocular minimum thickness of cornea in Chinese myopic population
Xiao-min, WU ; Si-si, CHEN ; Rong-rong, GAO ; Qin-mei, WANG ; Jin-hai, HUANG
Chinese Journal of Experimental Ophthalmology 2012;(11):1018-1021
Background Central corneal thickness (CCT)is an important parameter to evaluate corneal healthy status and is crucial for surgical planning.However,clinical study found that the center of cornea does not correspond to the thinnest point of cornea.Thus,it is essential to characterize the minimum corneal thickness(MCT) and its location.Objective Present study was to determine the thickness and location of MCT and its relationship to the fellow eye using Pentacam High Resolution technique.Methods The 564 eyes from 282 Chinese myopic patients were reviewed in this study.The CCT,MCT,pupillary central corneal thickness(PCT) and x-y coordinate of thinnest point were bilaterally measured.Written informed consent was obtained prior to the ocular biomedical measurement.Results CCT was (540.07±31.78) μm in the right eyes and (539.24±31.06) μm in the lefi eyes; PCT was (540.25±30.75)μm in the right eyes and (539.48±31.00)μm in the left eyes.MCT was (537.87± 31.91)μm in the right eyes and (536.35±31.24)μm in the left eyes,showing significant differences in all the parameters between the right eyes and left eyes expect for PCT(CCT:P=0.046;PCT:P=0.065 ;MCT:P=0.000).The C CT,PCT and M CT were significantly correlated between the right eyes and left eyes (r =0.97,0.97,0.98,P< 0.01).Bland-Altman plot showed a good consistence between the both eyes.The mean distance from the center was (0.50±0.21) mm in the right eyes and (0.56±0.22)mm in the left eyes,showing a significant difference (P =0.000).The difference between CCT and MCT was approximately (2.20±1.74)μm in the right eyes and (2.88±1.75) μm in the left eyes.The location of MCT in both the right eyes and left eyes tended to symmetry along the vertical midline.The distance between the R (x,y) to transformed L (x,y) was (0.29 ± 0.17)mm and the angular distance was (28.28±28.21)degree.Conclusions This study offers a range of MCT and its location in Chinese myopic patients.The difference exists between the CCT and MCT in bilateral eyes.The location of the thinnest point tends to be symmetrical along the vertical midline between the both eyes.The changes of these parameters may be helpful for the diagnosis of some corneal diseases.
3.Association of the single nucleotide polymorphisms in the calcitonin receptor-like receptor gene with primary angle closure in a Han Chinese population
Bai, QIN ; Hai-Hong, SHI ; Rong-Rong, ZHU ; Jun-Fang, ZHANG ; Mei, YANG ; Huai-Jin, GUAN
International Eye Science 2016;16(8):1570-1572
?AIM: To study the association of the single nucleotide polymorphism ( SNP) rs1157699 in the calcitonin receptor-like receptor ( CRLR ) gene with primary angle closure ( PAC) in a Han Chinese population.?METHODS: All samples, involved 232 PAC cases and 306 controls, were obtained from an epidemiologic survey conducted in Funing, Jiangsu Province, China. Genotyping were carried out by TaqMan-MGB probe using the real time quantitative polymerase chain reaction system to study the relationship between SNP of rs1157699 in CRLR gene and PAC.?RESULTS: The prevalence of CRLRrs1157699 genotype was 67.4%, 30.0%, 2.6% for CC, CT, TT in cases, and 71.3%, 27.0%, 1.7% in controls respectively.There was no difference between the two groups in the distribution of genotype and allele frequencies of rs1157699 (P>0.05).?CONCLUSION:Our results do not support a significant role for rs1157699 in CRLR with PAC.
4.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.
5.Repeatability and reproducibility of retinal straylight measurement using C-Quant compensation comparison method
Jin-hai, HUANG ; Shi-shi, LIN ; Qin-mei, WANG ; Bo, ZHENG ; Si-si, CHEN ; Rong-rong, GAO
Chinese Journal of Experimental Ophthalmology 2012;30(2):160-163
BackgroundIn an ideal eye there would be no light scattering at all,but the eye media is not optically ideal.Intraocular straylight causes a veil of light and reduction in the contrast of the retinal image and thus decrease the quality of vision.ObjectiveThe present study was to investigate the repeatability and reproducibility of C-Quant straylight meter( Oculus,Germany)in measuring retinal straylight of myopia and post-laser in situ keratomileusis(LASIK) corneas.MethodsThis is a prospective research.The consecutive 35 eyes of 21 myopic patients and 34 eyes of 22 patients who received LASIK were included in this trail.Retinal straylight was measured for 7 times at a period of time and analyzed quantificational to evaluate the repeatability of measurement.Thirty-eight eyes of 19 patients were measured again at 3-7 days for 3 times at a period of time to assess the reproducibility of C-Quant straylight meter.The mean standard difference (SD) and coefficient of variation (CV) were used as the credibility evaluation.This clinical study complied with Helsinki Declaration and the informed consent was obtained prior to the medical procedure.ResultsThe straylight Log(s) of 7 times measurement were all less than 0.95.The mean Log(s) were 0.92±0.12 and 0.93±0.17 respectively in myopia group and post-LASIK group,without statistically significant differences among 7 times measurement( F=0.335,P=0.812;F=1.000,P=0.409).The mean SD for the 7 times measurement was 0.07 Log units.SD and CV increased with the number of measurements.The differences of mean SD and CV between 3 times result and 6 times result were significant different (t =-2.080,P =0.045;t =-2.190,P =0.035 ).No difference was found between different time periods( t =-0.531,P=0.598 ).The difference of the results between two measurements from the same patient was 0.013.ConclusionsC-Quant is a noncontact,noninvade,rapid and convenient method for the measurement of straylight in myopia and post-LASIK eyes due to the high repeatability and reproducibility.
8.The Application of Immunohistochemistry in Reformation of Pathology Laboratory Teaching
Hai-Lin TANG ; Ying SONG ; Zhao-Yang LUO ; Rong-Jun TANG ; Qian-Jin LIAO ; Juan PENG ;
Chinese Journal of Medical Education Research 2006;0(10):-
Immunohistochemical technique was an essential tool of conventional diagnosis,therefore,the application of immunohisto- chemistry in reformation of pathology laboratory teaching would boost pathological experimental teaching standards to a higher level.
9.Analysis of Prognositic Factors of Severe Traumatic Brain Injury in Pediatric Intensive Care Unit
hai-rong, GONG ; zhu-jin, LU ; guo-ping, LU ; ling-en, ZHANG
Journal of Applied Clinical Pediatrics 1994;0(04):-
5 days.Blood gas analysis and blood pressure were determined at admitted day.Meanwhile,peripheral white blood cells at d1,3,5,and blood glucose were measured every day,respectively.GCS at d1,3,5 and hyperglycemia scorce(HS) were evaluated.Results Of the 82 studied patients,36 cases died.Univariate analysis showed that hypotension,lower GCS,higher peripheral white blood cells and HS were the independent death risk factors(Pa0.05).In multivariate logistic regression,the factors significantly associated with an increase in mortality were hypotension,lower GCS and higher HS.Conclusion Lower GCS,higher HS and hypotension are associated with poor outcome of children with severe trauma brain injury.
10.Evolutionary analysis of neuraminidase gene of A/H7N9 influenza virus.
Yi-Tong SUN ; Neng-Zhi JIN ; Hai-Rong ZHANG ; Yu-Lin SHEN ; Yao MA ; Tian-Shu PENG
Chinese Journal of Virology 2014;30(1):44-50
In 2013, the World Health Organization reported the first case of human infection with a new influenza A (H7N9) virus in China. This has caused damage and panic within certain areas in China. Therefore, analysis of this virus with bioinformatics technology is very necessary. Neuraminidase (NA) is one of the most important antigens of the influenza virus and an important target for anti-flu drugs. In this study, the nucleotide and protein sequences of NA gene of A/H7N9 influenza viruses were retrieved from the NCBI database, and MEGA 5.0 software was employed to construct a phylogenetic tree based on the nucleotide coding sequence; BioEdit software was used to align the nucleotide and protein sequences of NA and calculate the homologies of nucleotides and amino acids and then to analyze the important mutation sites of NA gene. The results demonstrated that the spread of influenza virus H7N9 showed certain geographical and temporal relations. The H7N9 virus isolated from China in 2013 belonged to Euroasiatic serotype, and its NA stalk region hadobvious variation, which may be one of the reasons that this virus infects human. These analyses may be very helpful for understanding the evolutionary relationship and mutation trend of A/H7N9 influenza viruses.
Databases, Genetic
;
Evolution, Molecular
;
Humans
;
Influenza A Virus, H7N9 Subtype
;
enzymology
;
genetics
;
Mutation
;
Neuraminidase
;
chemistry
;
genetics
;
Phylogeny
;
Sequence Analysis