2.Effects of shexiang baoxin pill on angiogenesis in atherosclerosis plaque and ischemic myocardium.
Wei SHEN ; Wei-hu FAN ; Hai-ming SHI
Chinese Journal of Integrated Traditional and Western Medicine 2010;30(12):1284-1287
OBJECTIVETo investigate the effects of Shexiang Baoxin Pill (SBP) in intervening atherosclerosis and myocardial infarction (AS-MI) in experimental animals, and inspect its influences on angiogenesis.
METHODSTwenty male New-Zealand rabbits were made into AS-MI model, and randomly divided into 2 groups equally. Group A was fed with high-fat diet for control; Group B was fed with high-fat diet but intervened with SBP. The cardiac function and the positive area of plaque were determined. The CD34 positive response intensity at infarcted marginal zone and aorta vessel wall, and the capillary density of myocardium were measured by immunohistochemical staining. In addition, the protein expressions of vascular endothelial growth factor (VEGF) and vascular endothelial growth factor receptor-2 (VEGFR-2) were detected by Western blot.
RESULTSCompared to Group A, the cardiac function was obviously improved (P<0.05) and the plaque positive area (%) was significantly decreased in Group B (45.82 +/- 3.68 vs 82.56 +/- 4.97, P<0.01). The CD34 positive response intensity and the capillary density as well as VEGF and VEGFR-2 expressions in infarcted marginal zone in Group A were higher than those in Group B (P<0.01); but these parameters at aorta vessel walls were lower in Group A than in Group B (P<0.01).
CONCLUSIONSBP could advance the angiogenesis in the marginal zone of infarction, improve heart function, and embarrass angiogenesis in atherosclerotic plaque.
Animals ; Atherosclerosis ; physiopathology ; Drugs, Chinese Herbal ; pharmacology ; Male ; Myocardial Ischemia ; physiopathology ; Neovascularization, Pathologic ; physiopathology ; prevention & control ; Neovascularization, Physiologic ; drug effects ; Plaque, Atherosclerotic ; pathology ; physiopathology ; Rabbits ; Random Allocation ; Vascular Endothelial Growth Factor A ; metabolism ; Vascular Endothelial Growth Factor Receptor-2 ; metabolism
3.Effects of rhodiola on expression of vascular endothelial cell growth factor and angiogenesis in aortic atherosclerotic plaque of rabbits.
Wei SHEN ; Wei-Hu FAN ; Hai-Ming SHI
Chinese Journal of Integrated Traditional and Western Medicine 2008;28(11):1022-1025
OBJECTIVETo investigate the effects of rhodiola on expression of vascular endothelial cell growth factor (VEGF) and angiogenesis in aortic atherosclerotic plaque of rabbits.
METHODSThirty male New Zealand rabbits were randomly divided into 3 groups equally, i. e. the control group (A) fed with common diet and treated with distilled water, the high fat diet group (B) and the rhodiola group (C) fed with diet containing 1.5% cholesterol and treated respectively with distilled water and rhodiola (1 mL/kg per day), all the treatments were administered via gastrogavage once a day for 9 successive weeks. Level of blood lipids in various groups was determined and compared at the end of the experiment. Meanwhile, the tissue sample of aorta was taken for observation through HE and Sudan red staining, for detecting the CD34 positive response intensity by immunohistochemical staining and the VEGF expression by Real-time fluorescent quantitative PCR and Western blot.
RESULTSDetermination of blood lipids showed that in Group C, TC was 42.01 +/- 1.99 mmol/L, TG 4.83 +/- 0.75 mmol/L and LDL-C 38.40 +/- 0.74 mmol/L, all lower than those in Group B (70.74 +/- 2.66 mmol/L, 8.75 +/- 0.78 mmol/L and 51.05 +/- 0.34 mmol/L, respectively), showing statistical difference between groups (P < 0.05). The intima/media tunica thickness ratio and the CD34 positive area of plaque in Group C were all lower than those in Group B (0.35 +/- 0.03 vs 0.43 +/- 0.03 and 29.12 +/- 2.56% vs 39.28 +/- 3.48%, P <0.05). Besides, the VEGF expression in atherosclerotic plaque was also lower in Group C than that in Group B.
CONCLUSIONRhodiola has the effects of inhibiting atherosclerosis formation, decreasing the VEGF expression and suppressing the angiogenesis in the plaque.
Animals ; Aorta ; drug effects ; metabolism ; physiopathology ; Atherosclerosis ; drug therapy ; metabolism ; physiopathology ; Disease Models, Animal ; Gene Expression ; drug effects ; Humans ; Male ; Neovascularization, Physiologic ; drug effects ; Plant Extracts ; administration & dosage ; Random Allocation ; Rhodiola ; chemistry ; Vascular Endothelial Growth Factor A ; genetics ; metabolism
4.Dosimetric study of three dimension therapy plans in patients with squamous cell carcinoma of tongue receiving postoperative intensity-modulated radiotherapy or conventional radiotherapy
Hai-sheng, HU ; Chao, YAN ; Hui-feng, SHI ; Zhong-he, WANG ; Ming, GUO
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(6):698-701
Objective To evaluate the dose distribution in clinical target volume (CTV) and organs-at-risk (OARs) in three dimension therapy plans in patients with squamous cell carcinoma of tongue receiving postoperative intensity-modulated radiotherapy (IMRT) or conventional radiotherapy (CRT) by dosimetric study. Methods Thirty-five patients with squamous cell carcinoma of tongue were divided into CRT group(n=17) and IMRT group(n=18). All patients underwent head-and-neck immobilization with a thermoplastic mask and planning CT scan, and target volume and OARs were contoured. Dose calculation and plan optimization were performed. All three dimension plans passed quality assurance before treatment. The dosimetry of therapy plans with IMRT or CRT in target volume and OARs dose distribution was compared by dose-volume histogram (DVH), conformity index (CI) and homogeneous index (HI). Results There were significant differences in D95 (isodose line to cover 95 percent target volume), CI, HI, minimum dose and maximum dose in CTV of therapy plans between patients with IMRT and CRT(P < 0.01), and there was no significant difference in mean dose of CTV(P > 0.05). The radiation dose on salivary glands (both parotid glands and contralateral submandibular gland) in patients with IMRT was significantly lower than that in patients with CRT(P < 0.01). Conclusion Compared with dose distribution of CRT plans, there are more advantages in improving dose distribution at the target volume and sparing salivary glands in IMRT therapy plans in patients with squamous cell carcinoma of tongue.
5.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
6.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
7.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.
8.Meta analysis of comparison of central corneal thickness measurement between Pentacam and A-scan in normal people
Shi-ming, CHENG ; Yan, LI ; Jin-hai, HUANG ; Xia, ZHOU ; Ling, XU
Chinese Journal of Experimental Ophthalmology 2013;(2):172-176
Background Central corneal thickness (CCT) is one of important parameters of the anterior eye segment.It plays a very important part in corneal refractive surgery and diagnosis of glaucoma.Contacted A-scan remains the gold standard for CCT measurement.Ophthalmologists are trying to look for a more convenient and noncontacted instrument to take place of contacted A-scan for CCT measurement.Objective This system analysis was to evaluate the difference between Pentacam and A-scan in CCT measurement.Methods A systematic literature retrieval was conducted from the MEDLINE,EMbase,Google Scholar,CBM disc and CNKI database with the limitation of publishing time from January 2005 to May 2011.The literature text was limited to the comparison of the CCT values measured by Pentacam and A-scan.The statistical analysis was performed using RevMan 5.1.0 software.Sensitive analysis was carried out and the publishing bias was analyzed using inverted funnel plot.Results A total of 26 studies met the requirement were included in this Meta-analysis with the 12 pieces of Chinese article and 14 pieces of English article,with the total eyes 3677.Heterogeneity was found anmong included studies (P =0.0003,I2 =56%) and random effects model was used.The differential value of CCT derived by Pentacam and A-scan was 1.74 μm,and no significant difference was found between Pentacam and A-scan (WMD =1.74,95% CI:-0.69-4.16,P>0.05).Fixed effects model was used to exclude the studies with the sample more than 100 eyes as the sensitive analysis.When fixed effect model was used,CCT by Pentacam was 2.73 μm more than A-scan,showing an insignificantly clinical difference.When studies with a sample more than 100 eyes were excluded,the CCT value by Pentacam was 2.64 μm more than A-scan,without clinically significant difference between them.No obvious publishing bias was seen in the included literature.Conclusions The difference between Pentacam and A-scan in CCT measurement is less and could be ignored.
9.Comparison of anterior segment measuring parameters in myopia after laser in situ keratomileusis between Sirius and Pentacam
Zhen, XU ; Jin-hai, HUANG ; Shi-ming, CHENG ; Yi-fan, FENG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2013;(6):572-577
Background Sirius system,a new Scheimpflug camera combined with Placido topography,improved the capability of imaging the anterior eye segment significantly.However,the study of assessing the repeatability and agreement between Sirius and Pentacam is still lack up to now.Objective This study was to evaluate the repeatability and agreement of the anterior ocular segment measuring parameters by Sirius and Pentacam in myopia received laser in situ keratomileusis (LASIK).Methods Thirty-five myopic eyes of 35 patients received LASIK were included in School of Optometry and Ophthalmology Eye Hospital from 2010 May through 2010 July.Corneal power flat keratometry (Kf),step keratometry (Ks),mean keratometry (Km),thinnest corneal thickness(TCT),the location of TCT,anterior chamber depth (ACD) and anterior chamber volume (ACV) were measured by Sirius and Pentacam in all the eyes,respectively.The repeatability of the measuring results were evaluated using intraclass correlation coefficients (ICC) and Cronbach's coefficient alpha (CoA),and the agreement of measuring parameters between Sirius and Pentacam was analyzed using Bland-Altman plot.Results Both Sirius and Pentacam demonstrated high intraobserver repeatability,with all ICC and CoA more than 0.90.No significant differences were found in Kf values and Ks values between the two methods (t =-1.533,-1.750,P>0.05).Km value was (39.14 ± 1.95) D by Sirius measurement,which was sígnificantly higher than (39.05 ± 1.91) D by Pentacam measurement (t =3.572,P =0.001).The TCT was (457.6 ± 40.9) μm by Sirius method,showing a significant reduce in comparison with (465.4±37.5) μm of Pentacam method (t =-6.689,P<0.001).A positive correlation was seen in the TCT between the two methods (r=0.988,P<0.001).The Bland-Alrman plots showed the 95% CI-21 μm to 6 pm in the TCT value between the two devices.Pairwise comparison of the location of TCT measurements showed significant differences between the two devices (t =-4.132,-5.696,P<0.001),with a good correlation (r=0.751,0.775) and the 95% CI (-0.36-0.17 mm,-0.35-0.12 mm).A very good agreement was seen in ACD between the two devices (-0.02-0.12 mm),but the agreement result was not very well in the ACV between the two devices with the 95% CI (-27.70-6.20 mm3).Conclusions Sirius and Pentacam measurements for anterior ocular segment parameters have a very good repeatability in post-LASIK eyes.In addition,good agreement results are exhibited in corneal power,TCT and ACD between Sirius and Pentacam with an acceptable maximal different value between them.Sirius and Pentacam can be used interchangeably in clinical examination.However,the two devices can not interchangeably for ACV measurement and TCT location.
10.Effect of mouse macrophage metalloelastase gene transfer into murine CT-26 colon cancer ceils on orthotopic tumor growth and angiogenesis
Hai SHI ; Jian-Ming XU ; Nai-Zhong HU ; Xuelong WANG ; Qiao MEI ; Junjun BAO ;
Chinese Journal of Digestion 2001;0(11):-
Objective To determine the correlation between mouse maerophage metalloelastase (MME)and vascular endothelial growth factor(VEGF)expression involved in angiogenesis of colon cancer.Methods A eDNA fragment coding for domainsⅠandⅡof MME was transfected into murine CT-26 colon cancer cells that were MME deficient.The enzymatic activity of recombinant MME was confirmed by cleavage of native substrate in vitro.An orthotopic implantation model was established by using MME-transfected cells and control cells.Tumor samples were subjected to in situ hybridization (ISH)and immunohistochemical staining(IHC)to detect expressions of MME and VEGF.The microvessel counting was used to assess angiogenesis of murine colon tumors.Results It was demon- strated that the tumor growth was significantly inhibited in MME-transfected group compared with pcDNA3.1 transfected and nontransfected groups(P<0.001).It was also found that,compared with pcDNA3.1-transfected and nontransfected groups,the microvessel formation in MME transfected group was significantly reduced(P<0.001).The expression of VEGF mRNA and protein was significantly lower in MME-transfected group than those in the controls,as demonstrated by ISH(MME-transfected group versus pcDNAa.1-transfected group,P=0.028;and versus nontransfected group,P=0.003) and by IHC(MME-transfected group versus pcDNA3.1-transfected group,P=0.025;and versus non- transfected group,P=0.008).Conclusions The MME gene transfected into murine colon cancer cells can effectively suppress the growth of orthotopic tumors by inhibition of vaseularity.Both MME and VEGF gene expression is highly associated with the vascularity of tumors,which may depend on a hal- ance between MME and VEGF expression.