1.Establishment and evaluation of the diagnostic kit for anti-HIV1/2 antibody and P24 antigen.
Yan HU ; Jun HOU ; Yan-qing FENG ; Chang-fang FENG ; Su-juan SHI ; Hong-hui H SHEN ; Zhi-jie WANG ; Bao-jun WANG ; Pan-yong MAO
Chinese Journal of Experimental and Clinical Virology 2007;21(4):391-393
OBJECTIVETo establish and evaluate an Enzyme Immunoassay diagnostic kit combined with anti-HIV1/2 antibody and P24 antigen for shortening the examination window period of HIV infection in HIV laboratory diagnosis.
METHODSThe enzyme-linked reaction plates was coated by anti-HIV P24 monoclonal antibody and HIV 1/2 antigen. Labeling HIV1/2 antigen and anti-HIV P24 polyclonal antibody with horseradish peroxidase, setup an integrated ELISA kit for detecting anti-HIV-1/2 antibody and HIV P24 antigen, and evaluate the specificity and sensitivity of this kit.
RESULTSThe sensitivity of testing P24 antigen was up to 0.2 ng/ml. 78 serum samples of patients with AIDS, 85 serum samples of healthy people were compared with Abbott EIA kit, the coincidence was 100%. 12 051 sera from normal persons and patients were examined, the sensitivity of 100 %and specificity of 99.62 %, respectively.
CONCLUSIONThe anti-HIV1/2 antibody and HIV P24 antigen can be measured at the same time using this EIA kit, while the examination window period of HIV infection is shortened. Thus, the method is suitable for laboratory diagnosis and epidemiological investigation.
Enzyme-Linked Immunosorbent Assay ; HIV Antibodies ; blood ; HIV Core Protein p24 ; blood ; HIV-1 ; immunology ; HIV-2 ; immunology ; Humans ; Reagent Kits, Diagnostic
2.Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay.
Kyunghoon LEE ; Hyung Doo PARK ; Eun Suk KANG
Annals of Laboratory Medicine 2013;33(6):420-425
BACKGROUND: Early diagnosis of HIV infection reduces morbidity and mortality. Fourth-generation HIV detection assays are more sensitive because they can detect p24 antigen as well as anti-HIV antibodies. In this study, we evaluated the performance of a new fourth-generation ADVIA Centaur HIV antigen/antibody combo (CHIV) assay (Siemens Healthcare Diagnostics Inc., USA) for early detection of HIV infection and reduction of false positive rate. METHODS: Four seroconversion panels were included. The third-generation ADVIA Centaur HIV 1/O/2 enhanced (EHIV) assay (Siemens Healthcare Diagnostics Inc., USA) and fourth-generation CHIV assay were used to test each panel for HIV infection. The presence of antigen was confirmed using HIV p24 antigen assay. To evaluate false-positivity and specificity, 54 HIV false-positive and HIV-negative serum samples from 100 hospitalized patients and 600 healthy subjects were included. RESULTS: Compared to the EHIV assay, the CHIV assay had a shorter window for three of the seroconversion panels: a difference of 10 days and two bleeds in one panel, and 4 days and one bleed in the other two panels. Only 34 of the 54 (63%) samples known to yield false-positive results by EHIV assay had repeatedly yielded reactive results in the CHIV assay. One of the 600 healthy subjects had a false-positive result with the CHIV assay; thus, the specificity was 99.85% (699/700). CHIV accurately determined the reactive results for the HIV-confirmed serum samples from known HIV patients and Korea Food & Drug Administration (KFDA) panels. CONCLUSIONS: The new fourth-generation ADVIA Centaur HIV assay is a sensitive and specific assay that shortens the serological window period and allows early diagnosis of HIV infection.
False Positive Reactions
;
Female
;
HIV Antibodies/*blood/immunology
;
HIV Core Protein p24/*blood/immunology
;
HIV Seropositivity/*diagnosis
;
Humans
;
Male
;
Pregnancy
;
Reagent Kits, Diagnostic
;
Republic of Korea
;
Sensitivity and Specificity
;
Time Factors
3.Assay for simultaneous detection of HIV p24 antigen and anti-HIV antibody.
Keyi XU ; Yongxin ZHANG ; Ying WANG ; Innocent MBAWUIKE
Chinese Journal of Experimental and Clinical Virology 2002;16(4):377-379
OBJECTIVETo develop a rapid assay for simultaneous detection of HIV p24 antigen (Ag) and anti-HIV antibody (Ab).
METHODSHIV-1 gp41 antigen and HIV-2 gp36 antigen were expressed by recombinant baculovirus insect system and purified by immunochromatography. p24 monoclonal antibody (mAb) was obtained from p24 hybridoma cell line. Purified antigen and mAb were dot blotted to nitrocellular membrane; 20 nm colloidal gold-anti-human IgG ab and p24 ab complex were used for this test. Previously detected 39 sera specimens were tested in this study to compare with the result of HIV test with commercial HIV test kit.
RESULTS20 mg/L purified gp41 Ag and gp36 Ag were obtained from recombinant baculovirus-insect cell system; 1.5 mg/L p24 mAb was obtained from p24 mAb hybridoma cell line. Compared the test result of 39 sera with commercial HIV test kits, consistency rate was 100%.
CONCLUSIONSThe rapid assay for simultaneous detection of HIV p24 antigen and anti-HIV antibody provides a simple, sensitive and reliable test for HIV diagnosis.
AIDS Serodiagnosis ; Gene Products, env ; biosynthesis ; isolation & purification ; HIV Antibodies ; blood ; HIV Antigens ; biosynthesis ; isolation & purification ; HIV Core Protein p24 ; blood ; HIV Envelope Protein gp41 ; biosynthesis ; isolation & purification ; HIV Infections ; diagnosis ; HIV-1 ; immunology ; HIV-2 ; immunology ; Humans ; Reagent Kits, Diagnostic ; standards ; env Gene Products, Human Immunodeficiency Virus