1.Spinal Subdural Hematoma Following Cranial Subdural Hematoma : A Case Report with a Literature Review.
Gyu Yeul JI ; Chang Hyun OH ; Daeyeong CHUNG ; Dong Ah SHIN
Journal of Korean Neurosurgical Society 2013;54(6):515-517
Coexistence of cranial and spinal subdural hematomas is rare and only a few cases have been reported in the literature. Herein, we report a case of cranial and spinal subdural hematomas after previous head trauma. As the pathogenesis of simultaneous intracranial and spinal subdural hematoma yet remains unclear, we developed an alternative theory to those proposed in the literature for their coexistence, the migration of blood through the subdural space.
Craniocerebral Trauma
;
Hematoma, Subdural*
;
Hematoma, Subdural, Spinal*
;
Subdural Space
2.Efficacy of a Novel Annular Closure Device after Lumbar Discectomy in Korean Patients: A 24-Month Follow-Up of a Randomized Controlled Trial
Pyung Goo CHO ; Dong Ah SHIN ; Sang Hyuk PARK ; Gyu Yeul JI
Journal of Korean Neurosurgical Society 2019;62(6):691-699
OBJECTIVE: Lumbar discectomy is an effective treatment for lumbar disc herniation (LDH); however, up to 2–18% of patients with LDH have experienced recurrent disc herniation. The purpose of this study was to evaluate the efficacy of a novel annular closure device (ACD) for preventing LDH recurrence and re-operation compared with that of conventional lumbar discectomy (CLD).METHODS: In this prospective randomized controlled trial, we compared CLD with discectomy utilizing the Barricaid® (Intrinsic Therapeutics, Inc., Woburn, MA, USA) ACD. Primary radiologic outcomes included disc height, percentage of preoperative disc height maintained, and re-herniation rates. Additional clinical outcomes included visual analog scale (VAS) scores for back and leg pain, Oswestry Disability Index (ODI) scores, and 12-item short-form health survey (SF-12) quality of life scores. Outcomes were measured at preoperation and at 1 week, 1, 3, 6, 12, and 24 months postoperation.RESULTS: Sixty patients (30 CLD, 30 ACD) were enrolled in this study. At 24-month follow-up, the disc height in the ACD group was significantly greater than that in the CLD group (11.4±1.5 vs. 10.2±1.2 mm, p=0.006). Re-herniation occurred in one patient in the ACD group versus six patients in the CLD group (χ²=4.04, p=0.044). Back and leg VAS scores, ODI scores, and SF-12 scores improved significantly in both groups compared with preoperative scores in the first 7 days following surgery and remained at significantly improved levels at a 24-month follow-up. However, no statistical difference was found between the two groups.CONCLUSION: Lumbar discectomy with the Barricaid® (Intrinsic Therapeutics, Inc.) ACD is more effective at maintaining disc height and preventing re-herniation compared with conventional discectomy. Our results suggest that adoption of ACD in lumbar discectomy can help improve the treatment outcome.
Diskectomy
;
Follow-Up Studies
;
Health Surveys
;
Humans
;
Intervertebral Disc Displacement
;
Leg
;
Prospective Studies
;
Quality of Life
;
Recurrence
;
Treatment Outcome
;
Visual Analog Scale
3.Clinical Effectiveness of Percutaneous Epidural Neuroplasty According to the Type of Single-Level Lumbar Disc Herniation : A 12-Month Follow-Up Study
Pyung Goo CHO ; Gyu Yeul JI ; Young Sul YOON ; Dong Ah SHIN
Journal of Korean Neurosurgical Society 2019;62(6):681-690
OBJECTIVE: To determine whether the outcomes of percutaneous epidural neuroplasty (PEN) are influenced by the type of lumbar disc herniation (LDH) and evaluate the effectiveness of PEN in patients with single-level LDH.METHODS: This study included 430 consecutive patients with single-level LDH who underwent PEN. Before treatment, the LDH type was categorized as bulging, protrusion, extrusion, and sequestration, while Pfirrmann grades were assigned according to imaging findings. Visual analog scale (VAS) scores for back and leg pain and success rates (Odom’s criteria) were assessed at 1, 3, 6, and 12 months after treatment.RESULTS: The mean preoperative VAS scores for back and leg pain were 6.90 and 4.23, respectively; these decreased after PEN as follows : 2.25 and 1.45, respectively, at 1 month; 2.61 and 1.68, respectively, at 3 months; 2.28 and 1.48, respectively, at 6 months; and 2.88 and 1.48, respectively, at 12 months (p<0.001). The decrease in VAS scores for leg pain was significantly greater in the extrusion and sequestration groups than in the other two groups (p<0.05); there were no other significant differences among groups. More than 70% patients exhibited good or excellent 12-month outcomes according to Odom’s criteria. Subsequent surgery was required for 59 patients (13.7%), with a significantly higher rate in the extrusion (25.0%) and sequestration (30.0%) groups than in the bulging (7.3%) and protrusion (13.8%) groups (p<0.05). Nevertheless, subsequent surgery was not required for >70% patients with extrusion or sequestration. Patients with Pfirrmann grades 1–3 (14.0–21.5%) showed a significantly higher rate of subsequent surgery than those with Pfirrmann grade 0 (4.9%; p<0.05).CONCLUSION: Our findings suggest that PEN is an effective treatment for back and leg pain caused by single-level LDH, with the outcomes remaining unaffected by the LDH type.
Follow-Up Studies
;
Humans
;
Intervertebral Disc Displacement
;
Leg
;
Low Back Pain
;
Treatment Outcome
;
Visual Analog Scale
4.Biomechanical Analysis of Biodegradable Cervical Plates Developed for Anterior Cervical Discectomy and Fusion
Pyung Goo CHO ; Gyu Yeul JI ; Sang Hyuk PARK ; Dong Ah SHIN
Asian Spine Journal 2018;12(6):1092-1099
STUDY DESIGN: In-vitro biomechanical investigation. PURPOSE: To evaluate the biomechanical effects of the degeneration of the biodegradable cervical plates developed for anterior cervical discectomy and fusion (ACDF) on fusion and adjacent levels. OVERVIEW OF LITERATURE: Biodegradable implants have been recently introduced for cervical spine surgery. However, their effectiveness and safety remains unclear. METHODS: A linear three-dimensional finite element (FE) model of the lower cervical spine, comprising the C4–C6 vertebrae was developed using computed tomography images of a 46-year-old woman. The model was validated by comparison with previous reports. Four models of ACDF were analyzed and compared: (1) a titanium plate and bone block (Tita), (2) strong biodegradable plate and bone block (PLA-4G) that represents the early state of the biodegradable plate with full strength, (3) weak biodegradable plate and bone block (PLA-1G) that represents the late state of the biodegradable plate with decreased strength, and (4) stand-alone bone block (Bloc). FE analysis was performed to investigate the relative motion and intervertebral disc stress at the surgical (C5–C6 segment) and adjacent (C4–C5 segment) levels. RESULTS: The Tita and PLA-4G models were superior to the other models in terms of higher segment stiffness, smaller relative motion, and lower bone stress at the surgical level. However, the maximal von Mises stress at the intervertebral disc at the adjacent level was significantly higher in the Tita and PLA-4G models than in the other models. The relative motion at the adjacent level was significantly lower in the PLA-1G and Bloc models than in the other models. CONCLUSIONS: The use of biodegradable plates will enhance spinal fusion in the initial stronger period and prevent adjacent segment degeneration in the later, weaker period.
Absorbable Implants
;
Diskectomy
;
Female
;
Finite Element Analysis
;
Humans
;
Intervertebral Disc
;
Intervertebral Disc Degeneration
;
Middle Aged
;
Spinal Fusion
;
Spine
;
Titanium
5.Efficacy of Percutaneous Epidural Neuroplasty Does Not Correlate with Dural Sac Cross-Sectional Area in Single Level Disc Disease.
Gyu Yeul JI ; Chang Hyun OH ; Bongju MOON ; Seung Hyun CHOI ; Dong Ah SHIN ; Young Sul YOON ; Keung Nyun KIM
Yonsei Medical Journal 2015;56(3):691-697
PURPOSE: Percutaneous epidural neuroplasty (PEN) is a minimally invasive treatment. The efficacy of PEN has been relatively well investigated; however, the relationship between the clinical effectiveness of PEN and the severity of spinal canal stenosis by disc material has not yet been established. The purpose of this study was to compare clinical outcomes of PEN according to the dural sac cross-sectional area in single level disc disease. MATERIALS AND METHODS: This study included 363 patients with back pain from single level disc disease with and without radiculopathy. Patients were categorized into groups according to spinal canal compromise by disc material: Category 1, less or more than 50%; and Category 2, three subgroups with lesser than a third, between a third and two thirds, and more than two thirds. Clinical outcomes were assessed according to the Visual Analog Scale (VAS) score for back pain and leg pain and Odom's criteria at 1, 3, 6, 12, and 24 months after treatment. RESULTS: The demographic data showed no difference between groups according to spinal canal compromise by disc material except age (older age correlated with more spinal canal compromise). The dural sac cross-sectional area did not correlate with the VAS scores for back and leg pain after PEN in single level disc disease in Groups 1 and 2. Odom's criteria after PEN were also not different according to dural sac cross-sectional area by disc material. CONCLUSION: PEN is an effective procedure in treating single level lumbar disc herniation without affecting dural sac cross-sectional area.
Adult
;
Aged
;
Back Pain/etiology/*surgery
;
Dura Mater/*pathology
;
Female
;
Humans
;
Intervertebral Disc
;
Intervertebral Disc Displacement
;
Magnetic Resonance Imaging
;
Male
;
Middle Aged
;
Reconstructive Surgical Procedures
;
Spinal Stenosis/complications/*pathology
;
Tissue Adhesions/*surgery
;
Treatment Outcome
;
Visual Analog Scale
6.Surface Landmarks do not Correspond to Exact Levels of the Cervical Spine: References According to the Sex, Age and Height.
Chang Hyun OH ; Gyu Yeul JI ; Seung Hwan YOON ; Dongkeun HYUN ; Chun Gil CHOI ; Hyun Kyoung LIM ; A Reum JANG
Korean Journal of Spine 2014;11(3):178-182
OBJECTIVE: A general orientation along the cervical spine could be estimated by external landmarks, and it was useful, quick and less exposable to radiation, but, sometimes it gave reference confusion of target cervical level. The authors reviewed the corresponding between the neck external landmarks and cervical levels. METHODS: Totally 1,031 cervical lateral radiographs of different patients were reviewed in single university hospital. Its compositions were 534 of males and 497 females; 86 of second decades (10-19 years-old), 169 of third decades, 159 of fourth decades, 209 of fifth decades, 275 of sixth decades, and 133 of more than seventh decades (>60 years-old). Reference external landmarks (mandible, hyoid bone, thyroid cartilage, and cricothyroid membrane) with compounding factors were reviewed. RESULTS: The reference levels of cervical landmarks were C2.13 with mandible angle, C3.54 with hyoid bone, C5.12 with thyroid cartilage, and C6.01 with cricothyroid membrane. The reference levels of cervical landmarks were differently observed by sex, age, and somatometric measurement (height) accordingly mandible angle from C1 to C3, hyoid bone from disc level of C2 and C3 to C5, thyroid cartilage from disc level of C3 and C4 to C7, and cricothyroid membrane from C4 to disc level of C7 and T1. CONCLUSION: Surface landmarks only provide general reference points, but not correspond to exact levels of the cervical spine. Intraoperative fluoroscopy ensures a more precise placement to the targeted cervical level.
Female
;
Fluoroscopy
;
Humans
;
Hyoid Bone
;
Male
;
Mandible
;
Membranes
;
Neck
;
Spine*
;
Thyroid Cartilage
7.Preliminary Experiences of the Combined Midline-Splitting French Door Laminoplasty with Polyether Ether Ketone (PEEK) Plate for Cervical Spondylosis and OPLL.
Chang Hyun OH ; Gyu Yeul JI ; Junseok W HUR ; Won Seok CHOI ; Dong Ah SHIN ; Jang Bo LEE
Korean Journal of Spine 2015;12(2):48-54
OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of cervical midline-splitting French-door laminoplasty with a polyether ether ketone (PEEK) plate. The authors retrospectively analyzed the results of patients with cervical laminoplasty miniplate (MAXPACER(R)) without bone grafts in multilevel cervical stenosis. METHODS: Fifteen patients (13 males and 2 females, mean age 50.0 years (range 35-72)) with multilevel cervical stenosis (ossification of the posterior longitudinal ligament and cervical spondylotic myelopathy) underwent a combined surgery of midline-splitting French-door laminoplasty with or without mini plate. All 15 patients were followed for at least 12 months (mean follow-up 13.3 months) after surgery, and a retrospective review of the clinical, radiological and surgical data was conducted. RESULTS: The radiographic results showed a significant increase over the postoperative period in anterior-posterior diameter (9.4+/-2.2 cm to 16.2+/-1.1 cm), open angles in cervical lamina (46.5+/-16.0degrees to 77.2+/-13.1degrees), and sectional volume of cervical central canal (100.5+/-0.7 cm2 to 146.5+/-4.9 cm2) (p<0.001). The sagittal alignment of the cervical spine was well preserved (31.7+/-10.0degrees to 31.2+/-7.6degrees, p=0.877) during the follow-up period. The clinical results were successful, and there were no significant intraoperative complications except for screw displacement in two cases. The mini plate constructs did not fail during the 12 month follow-up period, and the decompression was maintained. CONCLUSION: Despite the small cohort and short follow-up duration, the present study demonstrated that combined cervical expansive laminoplasty using the mini plate is an effective treatment for multilevel cervical stenosis.
Cohort Studies
;
Constriction, Pathologic
;
Decompression
;
Ether*
;
Female
;
Follow-Up Studies
;
Humans
;
Intraoperative Complications
;
Longitudinal Ligaments
;
Male
;
Postoperative Period
;
Retrospective Studies
;
Spine
;
Spondylosis*
;
Transplants
8.Delayed Vertebral Artery Dissection after Posterior Cervical Fusion with Traumatic Cervical Instability: A Case Report.
Chang Hyun OH ; Gyu Yeul JI ; Seung Hwan YOON ; Dongkeun HYUN ; Eun Young KIM ; Hyeonseon PARK ; A Reum JANG
Korean Journal of Spine 2015;12(2):79-83
Vascular injury presented immediately after the penetration, but delayed onset of vascular symptom caused by an embolism or vessel dissection after cervical fusion or traumatic event is extremely rare. We present a case of a 56-year-old woman who underwent an operation for cervical fusion for type II Odontoid process fracture. She presented symptoms of seizure with hemiparesis in 6 days after the operation. Multifocal acute infarction due to an embolism from the left VA (V3 segment) dissection was observed without a definite screw breach the transverse foramen. We hereby reported the instructive case report of delayed onset of vertebral artery dissection after posterior cervical fusion with type II odontoid process fracture patient. When a cervical operation performed in the cervical trauma patient, even if no apparent VA injury occurs before and during the operation, the surgeon must take caution not to risk cerebral infarction because of the delayed VA dissection.
Cerebral Infarction
;
Embolism
;
Female
;
Humans
;
Infarction
;
Middle Aged
;
Odontoid Process
;
Paresis
;
Seizures
;
Vascular System Injuries
;
Vertebral Artery Dissection*
9.Vertebral Artery Dissect Injury with Brown-Sequard Syndrome by a Neural Foramen Penetrated Electric Screw Driver Bit : A Case Report.
Chang Hyun OH ; Min Soo KIM ; Sung Hyun NOH ; Dong Ah SHIN ; Gyu Yeul JI
Korean Journal of Spine 2013;10(4):258-260
There are few reports in the literature of complete obstruction of the vertebral artery (VA) due to an electric screw driver bit penetration through the neural foramen into the spinal canal with Brown-Sequard syndrome (BSS). A 25-year-old man was admitted to the emergency department with a penetrated neck injury by an electric screw driver bit after a struggle. The patient presented the clinical features of BSS. Computed tomography scan revealed that the electric screw driver bit penetrated through the right neural foramen at the level of C3-4, and it caused an injury to the right half of the spinal cord. Emergent angiography revealed VA dissection, which was managed by immediate coil embolization at both proximal and distal ends of the injury site. After occlusion of the VA, the electric screw driver bit was extracted under general anesthesia. Bleeding was minimal and controlled without difficulties. No postoperative complications, such as wound dehiscence, CSF leakage, or infection, were noted. Endovascular approaches for occlusion of vertebral artery lesions are safe and effective methods of treatment.
Adult
;
Anesthesia, General
;
Angiography
;
Brown-Sequard Syndrome*
;
Cervical Vertebrae
;
Embolization, Therapeutic
;
Emergencies
;
Female
;
Hemorrhage
;
Humans
;
Methods
;
Neck Injuries
;
Postoperative Complications
;
Spinal Canal
;
Spinal Cord
;
Vertebral Artery Dissection
;
Vertebral Artery*
;
Wounds and Injuries
;
Wounds, Penetrating
10.Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software.
Dong Ah SHIN ; Gyu Yeul JI ; Chang Hyun OH ; Keung Nyun KIM ; Do Heum YOON ; Hyunchul SHIN
Journal of Korean Neurosurgical Society 2017;60(4):441-447
OBJECTIVE: Computed tomography (CT)-based method of three dimensional (3D) analysis (MIMICS®, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of MIMICS® system, and inter- and intra-observer reliability in the measurement of OPLL. METHODS: Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software (MIMICS®) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. RESULTS: The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987–0.999) for volume measurement, 0.973 (95% CI, 0.907–0.978) for thickness, 0.969 (95% CI, 0.895–0.993) for width, and 0.995 (95% CI, 0.983–0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991–0.996) for volume, 0.996 (range, 0.944–0.998) for length, 0.930 (range, 0.873–0.947) for width, and 0.987 (range, 0.985–0.995) for length. CONCLUSION: The medical image processing software (MIMICS®) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.
Longitudinal Ligaments*
;
Methods
;
Neurosurgeons
;
Observer Variation*