1.DETECTION OF IgM ANTIBODY WITH RECOMBINANT ANTIGEN rSAG1 FOR TOXOPLASMOSIS DIAGNOSIS
Yongfei TAN ; Xin YIN ; Junming TANG ; Jin SI ; Ming XU ; Xuren YIN ; Guoqun CAO ; Yousheng LIANG ; Yinchan ZHU
Chinese Journal of Schistosomiasis Control 1989;0(02):-
Objective To establish rSAG1-IgM-ELISA with purified rSAG1 fusion protein for immunodiagnosis of toxoplasmosis. Methods The rSAG1 fusion protein was purified by Ni 2+ column. The ELISA plate was coated with different concentrations of rSAG1, reacted with pooled positive and negtive human sera. Goat anti-human IgM conjugated to horseradish peroxidase was used as the second antibody. The appropriate detecting condition of the rSAG1-IgM-ELISA assay was determined by orthogonal experiment. The reproducibility, sensitivity and specificity of the assay were assessed. Thirty-five IgM-positive and 57 IgM-negative human sera detected by the imported IgM-ELISA kit were detected with the rSAG1-IgM-ELISA. Results The purity of rSAG1 was above 90%. The appropriate detecting condition was that the coated rSAG1 was 2 5 ?g/ml, the human serum was in 1∶100 dilution, and the second antibody was in 1∶4000 dilution. The coefficient of variation (CV) value of IgM-positive and IgM-negative pooled sera were 13 8% and 7 7% respectively. The inhibition rate of the assay was 62 0% The positive correspondence rate and negative correspondence rate were 82 9% (29/35) and 91 2% (52/57) respectively,the total correspondence rate was 88 0%, compared with the imported IgM-ELISA kit. Conclusions The rSAG1-IgM-ELISA has high sensitivity and specificity, and good correspondence rate with the imported IgM-ELISA kit. It indicates that rSAG1-IgM-ELISA has potential value for early diagnosis of toxoplasmosis.
3.Application of multi-slice spiral CT in the screening of coronary artery lesions in elderly patients with diabetes mellitus
Xiaoliang CHEN ; Xinliang CHEN ; Suqin ZHANG ; Guoqun MAO ; Mingfang LOU ; Huaguan ZHANG ; Yao CHEN ; Caigan ZHANG ; Wenyu WANG ; Linsheng WU ; Juan LI ; Min JIN ; Hongyan WANG
Chinese Journal of Geriatrics 2017;36(9):963-965
Objective To evaluate the clinical value of multi-slice spiral CT (MSCT)in the screening of coronary artery lesions in elderly patients with diabetes mellitus.Methods MSCT and coronary angiography(CAG)were performed in 136 elderly patients(68 patients with diabetes and 68 patients without diabetes).The number of diseased coronary segments and the plaque type (noncalcified,mixed and calcified)for each patient were determined.The characteristics of coronary lesions were compared between patients with and without diabetes.The sensitivity and specificity of MSCT were evaluated.Results More noncalcified and calcified plaques and few ermixed plaques were observed in patients with diabetes,compared with patients without diabetes(noncalcified plagues:10 cases or 14.7% vs.4 cases or 5.9%;calcified plagues:47 cases or 69.1% vs.39 cases or 57.4%)(P< 0.05).In addition,diabetic patients showed a significantly higher frequency of multivessel disease(P<0.05).Furthermore,MSCT was able to clearly show stenosis and plaque type in the trunk and branches of the coronary artery,with a sensitivity of 91.0%,a specificity of 95.0%,a positive predictive value of 93% and a negative predictive value of 96.0%.Conclusions Diabetes is associated with a higher risk of coronary artery disease.MSCT can effectively detect the characteristics of coronary artery disease in diabetic patients and is an effective,noninvasive,and safe screening method.