1.Comparison of dual-source parallel radio frequence transmission liver MRI at 3.0 T with conventional MRI
Zhuren LUO ; Dan WANG ; Baozhong SHEN ; Xilin SUN ; Guokun WANG ; Fang LIU ; Shuguang HU ; Chan QUEENIE
Chinese Journal of Radiology 2011;45(11):1032-1035
Objective To investigate the role of dual-source parallel radio frequence (RF) and single-source excitation in liver imaging at 3.0 T MR.Methods This study was a retrospective analysis.One hundred and seven subjects underwent a 3.0 T TX MR scanning including axial spectrally selective attenuated inversion recovery (SPAIR) T2WI,axial DWI and coronal balanced-fast field echo( Balanced FFE).Each sequence was carried out with both single-source and dual-source RF excitation.Student's t test was used to compare the differences between single-source and dual-source RF excitation in the image uniformity,signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR).Wilcoxon signed rank test was used to determine whether there was difference between conventional and parallel transmission in the score of image quality.Reader agreement was assessed using the Cohen's Kappa test.Results For the image uniformity,there was significant difference between single-source and dual-source excitation (418.40 ± 66.75 for single-source vs.416.26 ± 50.61 for dual-source,t =2.524,P < 0.05 ).There also existed significant difference between single-source and dual-source excitation in SNR and CNR,respectively.The SNR and CNR of parallel transmission (22.03 + 12.16 and 18.33 ± 10.01,respectively) were both higher than those of single transmission (20.36 ± 11.21 and 15.22 ± 8.95,respectively) ( t =- 2.630,P < 0.05 for SNR and t =- 4.238,P < 0.05 for CNR).Image quality comparisons revealed significantly better results with dual-source than single-source RF excitation at SPAIR T2 WI ( 1.40 + 0.42 vs.1.81 ± 0.27 ),DWI ( 1.08 ± 0.40 vs.1.63 ± 0.36 ) and Balanced FFE sequence ( 0.95 ± 0.45 vs.1.65 ± 0.37,Z =- 5.894,- 5.801 and - 6.985,respectively,P < 0.01 ).In the comparison of image quality,the agreement between the two readers was very good ( Kappa > 0.8,P < 0.05 ).Conclusion Dual-source parallel RF excitation MR imaging in liver enables reducing dielectric shading,improving homogeneity of the RF magnetic induction field,and increasing SNR and CNR at 3.0 T.
2.Application of continuous nursing based on hybrid electronic platform and fragmented time concept in out-of-hospital rehabilitation of patients with anterior cruciate ligament reconstruction
Yating WEN ; Xiaoping WANG ; Jun LIU ; Qingjun LIU ; Guokun SUN ; Yun XU
Chinese Journal of Practical Nursing 2023;39(10):729-736
Objective:To explore the application effect of continuous nursing based on hybrid electronic platform and fragmentation time in the out-of-hospital rehabilitation of patients with anterior cruciate ligament reconstruction.Methods:This was a randomized controlled study. From April 2020 to October 2021, a total of 90 patients undergoing anterior cruciate ligament reconstruction in Weifang People′s Hospital were selected as the research objects by convenience sampling. Forty patients from April to December 2020 were selected as control group, and 45 patients from January to October 2021 were selected as intervention group. The control group implemented routine discharge guidance and follow-up, while the intervention group was given continuous nursing plan based on the concept of hybrid electronic platform and fragmented time. Before operation and 1, 3 and 6 months after operation, the knee range of motion and Lysholm score of patients in the two groups were analyzed. At 1, 3 and 6 months after operation, the rehabilitation exercise compliance score, self-efficacy score and knee stability examination of the two groups were analyzed.Results:A total of 41 patients in each group completed the study. At 1 month after operation, the knee range of motion, Lysholm score, rehabilitation exercise compliance score and self-efficacy score of intervention group were (96.46 ±3.58) ° and (53.54 ± 6.57), (69.17 ± 6.27), (4.01 ± 0.38) points, respectively. In the control group, they were (89.02 ± 4.22)° and (45.02 ± 7.61), (56.78 ± 8.45), (3.61 ± 0.42) points. At 3 months after operation, they were (136.83 ± 4.30)° and (72.76 ± 4.96), (60.71 ± 5.87), (4.97 ± 0.32) points in the intervention group, (133.54 ± 3.58)° and (69.83 ± 6.65), (56.73 ± 8.57), (4.83 ± 0.45) points in the control group, respectively. At 6 months after operation, they were (139.39 ± 1.99)° and (85.61 ± 6.11), (57.71 ± 7.41), (6.58 ± 0.96) points in the intervention group, (138.29 ± 2.65)° and (81.80 ± 6.38), (47.90 ± 6.02), (6.35 ± 1.23) points in the control group, respectively. The knee range of motion, Lysholm score and rehabilitation exercise compliance score of the intervention group were better than those of the control group at 1, 3 and 6 months after operation, and the differences were statistically significant ( t values were 2.12-8.61, all P<0.05). The self-efficacy score of the intervention group was higher than that of the control group at 1 month after operation, and the difference was statistically significant ( t=4.57, P<0.05). Conclusions:The continuous nursing program based on hybrid electronic platform and fragmented time can improve the knee function of patients with anterior cruciate ligament reconstruction in the early postoperative period, improve the compliance of rehabilitation exercise and the level of early self-efficacy.