2.Application of high resolution sonography in evaluating vascular endothelial function in patients with early-stage diabetic patients
Zheng ZHANG ; Fajin GUO ; Dong HAN ; Mingxiao WU ; Huiling LI
Chinese Journal of Geriatrics 2003;0(08):-
Objective To evaluate the endothelial function in diabetic patients by high resolution sonography. Methods The intima-media thicknesses (IMT) of the bilateral carotid artery, femoral artery and the iliac artery of 22 elderly patients and 142 non-elderly patients with diabetes mellitus (DM) and 20 elderly and 20 non-elderly healthy persons were measured. The changes of the diameter of brachial artery were determined by measuring the diameter of brachial artery during reactive hyperemia and after sublingual nitroglycerin. Results The increased percentage of the brachial artery diameter under reactive hyperemia was significantly lower in elderly patients with DM (10. 03?6. 39)% than that in the elderly healthy control (15. 87?4. 79)% (P 0. 05). The IMT in elderly patients with early-stage DM incrassated significantly(P
3.Changes in serum sex hormone level and their significance in Alzheimer's disease
Hua YANG ; Qiumin QU ; Feng GUO ; Jianfeng HAN ; Chengbin WU
Journal of Xi'an Jiaotong University(Medical Sciences) 1982;0(04):-
0.05). Estrogen was lower in the patients with AD than in the normal controls and there was a significant difference between the two groups (P
4.Rituximab intrathecal injection combined with intravenous chemotherapy in the successful treatment of splenic marginal zone lymphoma with the central nervous system relapse: a case report and literatures review
Xiaochen CHEN ; Zhengming JIN ; Yue HAN ; Lingchuan GUO ; Depei WU
Journal of Leukemia & Lymphoma 2013;22(7):419-422
Objective To explore the clinical characteristics,pathological features,therapy and prognosis of a case of splenic marginal zone lymphoma (SMZL) with central recurrence,evaluation the safety and efficacy of rituximab intrathecal injection combined with intravenous chemotherapy.Methods Retrospectively analyze the case of SMZL with the central recurrence,and review the relevant literatures.Results According to the tests of MICM of bone marrow,spleen pathology,PET-CT and laboratory examination (LDH),patient was diagnosed as SMZL,IV group B,IPI and aaIPI was high risk group.After first-line therapy,the patient achieved complete remission.But then the central nervous system relapsed.The patients was treated with rituximab intrathecal injection combined with intravenous chemotherapy,the central focus disappeared.Conclusion SMZL belongs to low-grade lymphoma,which combined with central nervous system relapse is very rare.Rituximab intrathecal injection combined with intravenous chemotherapy in the treatment of the patients is safe to use,and have good clinical efficacy.
5.The comparison of three-dimensional power Doppler imaging and color Doppler flow imaging in the diagnosis of carotid artery stenosis
Xiuhua CHEN ; Mingxiao WU ; Xiujie HAN ; Fajin GUO
Chinese Journal of Ultrasonography 2008;17(9):759-762
Objective To compare the diagnosis value of three-dimensional power Doppler imaging(3D-PDI)and color Doppler flow imaging(CDFI)on carotid artery stenosis.Methods Forty-nine patients with carotid artery atherosclerosis plaque or stenosis diagnosed by CDFl were enrolled in the study.The degree and ratio of carotid artery stenosis were measured by 3D-PDI in free-hand mode,and measured by DSA in one week,the results were compared with CDFI.Results 3D-PDI of normal carotid artery with atheromatous plaque showed the stereo image,quantity character and exact position of plaque,volume of vessel lumen and spatial distribution of blood flow directly.There was no statistical difference in diameter stenosis rate between 3D-PDI and CDFI[(52.0±0.9)% vs(51.7±0.8)%,P>0.05],and the area stenosis rate measured by CDFI was significantly lower than that by 3D-PDI[(58.0±0.2)% vs(52.0±0.5)%,P<0.01].In the diagnosis of stenosis classification,the rates of light,mild and severe stenosis were significantly different between CDFI and 3D-PDI(P<0.05)and not significantly between 3D-PDI and DSA methods(X2=0.0538,P>0.05).The detection rates of atherosclerotic plaques numbers in carotid crotch were significantly different between 313-PDI and CDFI(P<0.05).Conclusions 3D-PDI can offer more valuable information for the diagnosis and trentment of carotid artery stenosis,it is more accurate than CDFI and similar to DSA.
6.Percutaneous radiofrequency ablation of hepatic malignancies guided by ultrasonography
Zhijian ZHANG ; Mengchao WU ; Jia GUO ; Yi CHEN ; Han CHEN
Chinese Journal of General Surgery 2001;10(2):102-105
Objective To study the value of B type ultrasonography guiding percutaneous radiofrequency ablation (PRFA) for hepatic cancer (HC). Methods 70 patients with primary or metastatic hepatic malignancies were treated by PRFA under ultrasound guidance through LeVeen multipolar array needle electrode and RF 2000. All patients were followed up by turnor marker, B type sounography and MRI monthly. Results PRFA were performed in 53 patients with hepatocellular carcinoma (HCC) and 17 cases with metastatic liver cancer. Liver function classfication was 53 cases in Child class A, 15 in class B and 2 in class C. In 21 patients with non-operated small HCC (≤5 cm), 12 of 17 patients with AFP positive were decreased to normal (70.6%) and decreased markedly in 4 (23.5%), and MRI showed the treated tumors were completely necrosis in 16 patients (76.2%). The 3, 6 month survival rates were 90.5%, 100% respectively in small HC groups, and 66.7% to 72.7% and 27.6% to 72.7% in large HC groups.Conclusions PRFA as a local thermal therapy is becoming a kind of new palliative treatment for hepatic malignancies, which not only is safe, minimally invasive, and effective for small ones; but also can be used with combination of TACE for larger ones.
7.Diagnostic and therapeutic value of color Doppler flow imaging to elderly femoral arterial pseudo aneurysms
Xiuhua CHEN ; Fajin GUO ; Guang XU ; Xiajie HAN ; Mingxiao WU
Chinese Journal of Postgraduates of Medicine 2009;32(11):35-37
Objective To evaluate the value of color Doppler flow imaging (CDFI) in the diagnosis of elderly femoral arterial pseudo aneurysm and treating with ultrasound-guided compression after percutaneous transluminal coronary angioplasty (PTCA). Methods Twenty-six elderly patients who were found a mass and/or vascular murmur in the puncture region were examined by CDFI, and the results of CDFI were proven by clinic and MRI. All pseudo aneurysms were repaired by CDFI guidance to compress simply and/or injecting directly batroxobin into the pseudo aneurysm lumen combined with compression.Results Pseudo aneurysms were diagnosed definitely by CDFI in 26 cases,and the accuracy rate was 100%. Twenty-two cases were repaired with CDFI guidance to compress simply and percutaneously injection of batroxobin into the pseudo aneurysm lumen combined with compression occurred in 3 cases. One case was cured by surgery after failing to be repaired with CDFI guidance. Conclusions CDFI has an important diagnosis value of pseudo aneurysm after PTCA. The method of CDFI guidance compression and batroxobin injection for repairing pseudo aneurysm is simple, safe and effective.
8.The status and related factors of daily activities in patients with chronic obstructive pulmonary disease
Aimin GUO ; Jiangna HAN ; Ping WANG ; Yingxiang LIN ; Zhenglai WU
Chinese Journal of Nursing 2010;45(5):409-412
Objective To determine relationships between daily activities measured as modified version of Pulmonary Functional status and Dyspnea Questionaire (PFSDQ-M) and functional capacity and symptoms experienced in patients with chronic obstructive pulmonary disease (COPD). Methods Convenience sample of 94 COPD patients with stable condition were assessed by interview with PFSDQ-M Chinese version and modified Medical Research council dyspnea scale (MMRC) respectively. Pulmonary function test (PFT) and 6-minute walking test (6MWT) were undergone on the same day or within one week as interview. PFSDQ-M has three subscales,i.e.,change experienced by patient with activities (CA),dyspnea with activities (DA) and fatigue with activities (FA). Results Scores of CA,DA and FA correlated to 6-minute walking distancer= (-0.37)- (-0.42),FEV_1 r=(-0.27)-(-0.32),FEV_1/FVC r= (-0.27)- (-0.32),dyspnea rated by MMRC (r=0.55-0.60) and BODE index (r=0.35-0.40),respectively (all P<0.01). dyspnea explained 26% of the variance in changes of activities. Conclusions Physical activities moderately changed in patients with stable COPD;Dyspnea is the best predictor of limitation of daily activities.
9.Effect of fluoride concentration on the corrosion behavior of cobalt-chromium alloy fabricated by two different technology processes.
Qiuxia YANG ; Ying YANG ; Han XU ; Di WU ; Ke GUO
West China Journal of Stomatology 2016;34(1):47-53
OBJECTIVEThis study aims to determine the effect of fluoride concentration on the corrosion behavior of cobalt-chromium alloy fabricated by two different technology processes in a simulated oral environment.
METHODSA total of 15 specimens were employed with selective laser melting (SLM) and another 15 for traditional casting (Cast) in cobalt-chromium alloy powders and blocks with the same material composition. The corrosion behavior of the specimens was studied by potentiodynamic polarization test under different oral environments with varying solubilities of fluorine (0, 0.05%, and 0.20% for each) in acid artificial saliva (pH = 5.0). The specimens were soaked in fluorine for 24 h, and the surface microstructure was observed under a field emission scanning electron microscope after immersing the specimens in the test solution at constant temperature.
RESULTSThe corrosion potential (Ecorr) value of the cobalt-chromium alloy cast decreased with increasing fluoride concentration in acidic artificial saliva. The Ecorr, Icorr, and Rp values of the cobalt-chromium alloy fabricated by two different technology processes changed significantly when the fluoride concentration was 0.20% (P < 0.05). The Ecorr, Icorr, and Rp values of the cobalt-chromium alloy fabricated by two different technology processes exhibited a statistically significant difference. The Icorr value of the cobalt-chromium alloy cast was higher than that in the SLM group cobalt-chromium alloy when the fluoride concentration was 0.20% (P < 0.05). The Ecorr, tRp alues of the cobalt-chromium alloy cast were lower htan those of the SLM group cobalt-chromium alloy when the fluoride concentration was 0.20% (P< 0 .05).
CONCLUSIONFluoride ions adversely affected the corrosion resistance of the cobalt-chromium alloy fabricated by two different technology processes. The corrosion resistance of the cobalt-chromium alloy cast was worse than that of the SLM group cobalt-chromium alloy when the fluoride concentration was 0.20%.
Chromium Alloys ; Corrosion ; Fluorides ; Lasers ; Phosphates ; Saliva, Artificial ; Sodium Fluoride
10.Study on relationship between lower extremity venous thrombotic disease and seasons
Yanfang PAN ; Hongfang WU ; Lingling ZHAO ; Haitao GUO ; Shuming HAN
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care 2017;24(3):307-309
Objective To investigate the relationship between the onset of lower extremity venous thrombotic disease and seasons.Methods A retrospective study was conducted, 300 patients with lower extremity venous thrombotic disease admitted to HandanCity Hospital of Traditional Chinese Medicine (TCM) from August 2012 to February 2014 were enrolled, the incidences and TCM syndromes of patients with lower extremity venous thrombotic disease in different seasons were observed, and the pathogenesis and relationships between the types of TCM syndrome and seasons were analyzed.Results There were 142 patients with lower extremity superficial thrombophlebitis, and 158 cases with lower extremity deep venous thrombosis, the incidence of lower extremity venous thrombotic disease in spring was significantly higher than that in summer and autumn [32.8% (86/262) vs. 21.3% (54/254), 18.4% (50/272), bothP < 0.01], but lower than that in winter [32.8% (86/262) vs. 37.2% (110/296)], the difference was not statistically significant (P > 0.01); while the incidence of lower extremity venous thrombotic disease in winter was significant higher than those in summer and autumn (allP < 0.01). The incidences of damp and heat downward flow type in autumn and summer were increased compared with those in winter and spring [55.6% (30/54), 60.0% (30/50) vs. 20.0% (22/110), 23.3% (20/86), allP < 0.01], while the incidences of lower extremity venous thrombotic disease with damp heat and stasis syndrome in winter and spring were increased compared with those in summer and autumn seasons [80.0% (88/110), 76.7% (66/86) vs. 44.4% (24/54), 40.0% (20/50)].Conclusions The incidence of lower extremity venous thrombotic disease is related to seasons, and the onset is high in winter and spring, damp heat and stasis syndrome being the main type; according to different seasons, clinical treatment can direct to different pathogenic factors to adopt different preventive measures interfering with the patient's constitution in order to eliminate or reduce the risk factors, achieving the effect of the disease prevention.