1.Current status of veno-venous bypass in liver transplantation
Zixuan YANG ; Guizhu PENG ; Yan XIONG ; Ren WANG ; Qifa YE
Chinese Journal of Hepatobiliary Surgery 2015;21(8):567-569
Since Shaw et al,first reported the first case successfully treated by veno-venous bypass (VVB),there has been great controversy on the routine application of VVB during conventional liver transplantation and piggyback liver transplantation in recent decades.With the improvements on the surgical skills,surgical techniques and anesthesiology,only a small portion of patients have the indications for VVB in liver transplantation routinely.This article reviews the current publications in this topic,which may provide new insight into the liver transplantation in clinical practice.
2.Comparison of gender differences in the rat model of fluorosis
Yang LIU ; Lunying HAN ; Chuan HE ; Fengtao PENG ; Guizhu LI ; Feiqing WANG
Chinese Journal of Comparative Medicine 2018;28(1):33-37
Objective To construct the male and female rat model of fluorosis and to explore the gender difference in fluorosis. Methods A total of 48 clean-grade SD rats with the body weight of about 150 g (male∶female=1∶1) were equally divided into the control group and fluorosis model group. Rats in the fluorosis model group were fed with fluorine-containing (100 mg/kg) feedstuff. The general condition, changes in body weight and dental fluorosis of the rats were observed every three days. A batch of female and male rats were sacrificed by femoral artery bleeding on the 70th and 110th day of experiment, respectively, when all rats showed dental fluorosis. The levels of urinary fluoride and bone fluoride of the rats were measured by a fluoride ion-selective electrode. Results All the male and female rats in the control group did not show dental fluorosis during the entire experiment. The female and male rats in the fluorosis group showed dental fluorosis visible to naked eye began approximately on the 60th and 80th day, respectively, indicating that the appearance of dental fluorosis of the male rats was about 20 days later than the female rats. After 30 days or so, the male and female rats went into a rapid growth period, and there were significant differences between the body weights of the male and female rats (P< 0. 01). The body weight of the male and female rats in the fluorosis group was higher than that of the control group on the 110th day. With the progression of fluorosis, the levels of urinary fluoride and bone fluoride of the rats were gradually increased, and finally significantly higher than those of the control group (P< 0. 01). There was a positive correlation between the levels of urinary and bone fluoride and the time of fluorosis. The levels of urinary and bone fluoride of the male rats were significantly higher than those of the female rats (P< 0. 01), indicating that they are affected by gender. Conclusions The body weight of the rat model of fluorosis, the starting time when dental fluorosis occurs and the levels of urinary and bone fluorine are all different between male and female rats.
3.Finite element simulation and experimental test of normal coracoclavicular ligament and flexible reconstruction
Guizhu JI ; Qiu ZHENG ; Wuxiang WANG ; Guan WANG ; Wen LI ; Xiaobo LU ; Ke DUAN ; Zhong LI ; Hongbin YANG ; Cheng LIANG
Chinese Journal of Tissue Engineering Research 2024;28(5):706-711
BACKGROUND:For dislocation of acromioclavicular joint induced by coracoclavicular ligament fracture,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are common repair methods.Further study on the stress distribution and fracture risk of the two repair methods is of great significance. OBJECTIVE:To study the biomechanical properties of the coracoclavicular ligament,and compare the fixation effect,stress distribution and failure mode of single and double EndoButton Plates reconstruction. METHODS:(1)Finite element simulation analysis:Mimics,Wrap and SolidWorks were used to establish normal coracoclavicular ligament,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction.Ansys software was used to analyze the stress and deformation of the scapula and clavicle of each model under vertical load.(2)Sample experiment:Fifteen intact scapular-clavicle specimens were randomly grouped into five groups,with three specimens in each group.In group A,the acromioclavicular ligament was severed and the coracoclavicular ligament remained intact.In group B,acromioclavicular ligaments and trapeoid ligaments were severed,leaving intact conical ligaments.In group C,acromioclavicular ligaments and conical ligaments were cut off,and the intact traprex ligaments were retained.In group D,acromioclavicular and coracoclavicular ligaments were severed,and coracoclavicular ligaments were repaired by single EndoButton Plate reconstruction.In group E,acromioclavicular and coracoclavicular ligaments were severed,and the coracoclavicular ligaments were repaired by double EndoButton Plates reconstruction.The mechanical experiment was carried out by a mechanical testing machine to analyze the biomechanical status,stress distribution and failure patterns of the scapular-clavicle and clavicle. RESULTS AND CONCLUSION:(1)Finite element simulation analysis:The average stress of coracoclavicular ligament attached specimens was the lowest,and the risk of coracoclavicular fracture was less than that of single and double EndoButton Plates reconstruction.The mean stress of the coracoid process was similar in single and double EndoButton Plates reconstruction,and the fracture risk was similar.(2)Sample experiment:In groups A,B,C,D and E,the stiffness of specimens was(26.4±3.5),(19.8±2.8),(21.3±3.2),(57.7±4.1),and(46.2±2.8)N/mm,respectively;the ultimate loads were(545.5±53.7),(360.1±42.1),(250.9±44.4),(643.5±39.1),and(511.9±31.7)N,respectively;global stiffness in groups D and E was higher than that in group A(P=0.000 06,0.000 3);ultimate load in group D was higher than that in group A(P<0.05);the ultimate load was not significantly different between the group E and group A(P>0.05).Ligament fracture was observed in groups A,B and C and coracoid process fracture was found in groups D and E.(3)These results suggest that from the biomechanical analysis,Single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are effective treatment techniques for coracoclavicular ligament fracture in acromioclavicular joint dislocation,but increase the risk of fracture.The double EndoButton Plates reconstruction dispersed the stress of the steel plate and reduced the contact force between the steel plate and bone,but slightly reduced the ultimate bearing capacity.Single and double EndoButton Plates reconstruction should be selected according to the actual clinical situation.
4.A biomimetic nanoplatform for customized photothermal therapy of HNSCC evaluated on patient-derived xenograft models.
Qi WU ; Lan CHEN ; Xiaojuan HUANG ; Jiayi LIN ; Jiamin GAO ; Guizhu YANG ; Yaping WU ; Chong WANG ; Xindan KANG ; Yanli YAO ; Yujue WANG ; Mengzhu XUE ; Xin LUAN ; Xin CHEN ; Zhiyuan ZHANG ; Shuyang SUN
International Journal of Oral Science 2023;15(1):9-9
Cancer cell membrane (CCM) derived nanotechnology functionalizes nanoparticles (NPs) to recognize homologous cells, exhibiting translational potential in accurate tumor therapy. However, these nanoplatforms are majorly generated from fixed cell lines and are typically evaluated in cell line-derived subcutaneous-xenografts (CDX), ignoring the tumor heterogeneity and differentiation from inter- and intra- individuals and microenvironments between heterotopic- and orthotopic-tumors, limiting the therapeutic efficiency of such nanoplatforms. Herein, various biomimetic nanoplatforms (CCM-modified gold@Carbon, i.e., Au@C-CCM) were fabricated by coating CCMs of head and neck squamous cell carcinoma (HNSCC) cell lines and patient-derived cells on the surface of Au@C NP. The generated Au@C-CCMs were evaluated on corresponding CDX, tongue orthotopic xenograft (TOX), immune-competent primary and distant tumor models, and patient-derived xenograft (PDX) models. The Au@C-CCM generates a photothermal conversion efficiency up to 44.2% for primary HNSCC therapy and induced immunotherapy to inhibit metastasis via photothermal therapy-induced immunogenic cell death. The homologous CCM endowed the nanoplatforms with optimal targeting properties for the highest therapeutic efficiency, far above those with mismatched CCMs, resulting in distinct tumor ablation and tumor growth inhibition in all four models. This work reinforces the feasibility of biomimetic NPs combining modular designed CMs and functional cores for customized treatment of HNSCC, can be further extended to other malignant tumors therapy.
Animals
;
Humans
;
Squamous Cell Carcinoma of Head and Neck/therapy*
;
Heterografts
;
Photothermal Therapy
;
Biomimetics
;
Disease Models, Animal
;
Head and Neck Neoplasms/therapy*
;
Cell Line, Tumor
;
Tumor Microenvironment
5.Correction To: A biomimetic nanoplatform for customized photothermal therapy of HNSCC evaluated on patient-derived xenograft models.
Qi WU ; Lan CHEN ; Xiaojuan HUANG ; Jiayi LIN ; Jiamin GAO ; Guizhu YANG ; Yaping WU ; Chong WANG ; Xindan KANG ; Yanli YAO ; Yujue WANG ; Mengzhu XUE ; Xin LUAN ; Xin CHEN ; Zhiyuan ZHANG ; Shuyang SUN
International Journal of Oral Science 2023;15(1):12-12