1.CT-guided interstitial implantation of ~(125)I seeds for non-small cell lung cancer
Journal of Interventional Radiology 2009;18(9):704-707
Objective To discuss the technique, therapeutic effect and complications of CT-guided interstitial implantation of ~(125)I seeds for the treatment of non-small cell lung carcinoma (NSCLC). Methods With the help of treatment planning system, CT-guided interstitial implantation of ~(125)I seeds was performed in 21 patients with pathologically-proved NSCLC. Multi-plane implanting technique was adopted and ~(125)I seeds of (0.5 -0.8) mCi were placed at intervals of (1.0-1.5) cm. Checkup CT scan was carried out immediately after the procedure to make sure that the seeds were satisfactorily distributed. Follow-up CT scanning was made (2-6) months after the treatment to survey the distribution of the seeds within the tumor. The curative effect and complications were also evaluated and observed. The patients were followed for 12 months. Results Of 21 cases, complete remission was seen in 7, obvious remission in 12 and partial remission in 2. The one year survival rate was 90.5% (19/21). Complications included pneumothorax (n = 6) and hemoptysis (n = 2). No serious complications or treatment-related radiation injuries occurred. Conclusion CT-guided interstitial implantation of ~(125)I seeds is a safe and effective treatment for NSCLC with reliable short-term therapeutic effect.
2.Analysis on psychological distress of telephone operators and related factors by ordinal logistic regression
Xiaohong TIAN ; Yaoyao SUN ; Guiyuan ZOU ; Chunqin LIU ; Ping LI
Chinese Mental Health Journal 2015;(10):790-794
Objective:To investigate the current status and related factors of psychological distress in tele-phone operators.Methods:Totally 575 telephone operators from sample of a convenient survey in a certain telecom-munication company of Shandong Province were selected.They were assessed with Kessler Psychological Distress Scale (K10),Connor-Davidson Resilience Scale (CD-RISC-10),Perceived Social Support Scale (PSSS)and Sim-plified Coping Style Questionnaire (SCSQ)for the evaluation of psychological distress,resilience,perceived social support and the coping style respectively.Ordinal logistic regression was used to identify the related factors of psy-chological distress.Results:The mean score of K10 was (24.7 ±6.7),91.8% (528 /575)of telephone operators had psychological distress.Specifically,24.5%(141 /575)had mild psychological distress,45.4% (261 /575)had moderate psychological distress,21.9% (126 /575)had severe psychological distress.Ordinal logistic regression a-nalysis indicated that the ones with good economic conditions (OR =1.74,95%CI:1.15 -2.63),higher level of re-silience (OR =1.13,95%CI:1.10 -1.17)and other social support (OR =1.07,95%CI:1.02 -1.12)had milder psychological distress;while with negative coping style (OR =0.29,95%CI:0.20 -0.41)had more severe psycho-logical distress.Conclusion:It suggested that the prevalence rate of psychological distress among telephone opera-tors is high.Poor economic conditions,lower level of resilience and social support,and negative coping style might be the related factors of psychological distress.
3.Development and Evaluation of Healthcare Food Based on "State Adjustment" Strategy
Yajuan TIAN ; Jie SU ; Yu WANG ; Su GAO ; Guiyuan LYU
Chinese Journal of Experimental Traditional Medical Formulae 2022;28(18):192-197
With the acceleration of aging and the changes of people's lifestyle and environment, the incidence of chronic non-communicable diseases (chronic diseases) in China is increasing, which has become a major public health problem. The number of sub-health people is even more and rising. The thought of treating disease before its onset emphasizes taking precautions against disease and preventing change after disease onset, which is one of the core contents of traditional Chinese medicine (TCM) theory. According to the theory of TCM, health as a dynamic balance of yin and yang and diseases can be prevented and treated by maintaining this balance. The "state adjustment" strategy suggests to treat diseases by adjusting the state of exuberance or decline based on recognizing and distinguishing "state", which has important guiding significance for developing and evaluating the healthcare food produced with Chinese medicinal materials. Healthcare food plays a vital role in health promotion, chronic disease prevention, and quality of life improvement. At present, the healthcare food produced with Chinese medicinal materials in China generally lacks TCM guidance and fails to fully reflect the advantages of TCM. In this study, the development strategy, functional claims, evaluation methods, and existing problems of healthcare food were discussed. Furthermore, with diabetes as an example, the "state adjustment" strategy was introduced into product development and evaluation to provide ideas for promoting the rapid growth of healthcare food with TCM characteristics.
4.Feasibility of acceptance of multiple accelerators using Elekta AGL standard procedures
Liang ZHAO ; Guiyuan LI ; Xiaohong WAN ; Xinyuan CHEN ; Kuo MEN ; Jianrong DAI ; Yuan TIAN
Chinese Journal of Radiation Oncology 2024;33(3):244-249
Objective:To verify the feasibility of using Elekta accelerated go live (AGL) standard process for the acceptance of multiple accelerators.Methods:The beams of three accelerators were adjusted by PTW Beamscan three-dimensional water tank to reach the AGL standard. Dose verification was performed for three accelerators that met AGL standards. A simple field test example from Cancer Hospital Chinese Academy of Medical Sciences was used to compare the MapCheck 3 surface dose measurement results with the surface dose calculated by the same accelerator model. Images of 10 patients including head and neck, esophagus, breast, lung and rectum were randomly selected. volumetric-modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) treatment techniques were used for planning design, and the measured dose of ArcCheck was compared with the planned dose calculated by the same accelerator model. One-way ANOVA was used to statistically analyze the passing rates of two-dimensional and three-dimensional dose verification.Results:The 6 MV X-ray percentage depth dose at 10 cm underwater (PDD 10) of three accelerators was 67.45%, 67.36%, 67.47%, and the maximum deviation between the three accelerators was 0.11%. The 6 MV flattenting filter free (FFF) mode X-ray PDD 10 was 67.33%, 67.20%, 67.20%, and the maximum deviation between the three accelerators was 0.13%. All required discrete point doses on each energy 30 cm×30 cm Profile spindle of the three accelerator X-rays deviated less than ±1% from the standard data. Absolute γ analysis was performed on the results of MapCheck 3 two-dimensional dose matrix validation. Under the 10% threshold of 2 mm/3% standard, the average passing rate of the test cases in Cancer Hospital Chinese Academy of Medical Sciences was above 99%, and the difference was not statistically significant ( P>0.05). Absolute γ analysis was performed on the ArcCheck verification results. Under the 10% threshold, the pass rate of 2 mm/3% was all above 95%, the maximum average passing rate of the three accelerators with different energy and different treatment techniques was 0.28% (6 MV, VMAT), 0.19%(6 MV FFF, VMAT), 0.56% (6 MV, IMRT) and 0.05% (6 MV FFF, IMRT), and the difference was not statistically significant ( P>0.05). Conclusion:Compared with traditional accelerator acceptance process, the acceptance time of each accelerator is shortened by 4-6 weeks by using the AGL standard process, and the radiotherapy plan of patients can be interchangeably executed among different accelerators.
5.Optimization of simulated localizable CT scanning parameters for pediatric body radiotherapy
Guiyuan LI ; Xinyuan CHEN ; Liang ZHAO ; Xiaohong WANG ; Yuan TIAN ; Jianrong DAI ; Junlin YI
Chinese Journal of Medical Physics 2024;41(5):534-540
Objective On the premise of meeting the image quality requirements of simulated location for pediatric radiotherapy,the simulated localizable CT parameters are optimized through phantom scanning to reduce the radiation dose.Methods CatPhan700 phantom was used to simulate the child's body,Philip 24-row large-aperture spiral simulated localizable CT was performed,and the CT images were obtained by scanning the phantom at different mAs and tube voltages.The mAs range was set at 60-400 mAs,the scanning was performed every 20 mAs interval,and the kV was set at 80,100,and 120 kV.Image evaluation was carried out using parameters such as image noise(N10 and mean SD),uniformity,low contrast resolution,high contrast resolution,and the stabilities of HU values of Air,Acrylic,50%bone,LDPE,20%bone,Teflon,Polystyrene,DelrinTM,Lung,PMP and Water.The CTDIVol and DLP automatically calculated by the simulated localizable CT system were read to evaluate the radiation dose.Results At 100 kV,as mAs increased,both CTDI and DLP showed upward trends,and the fitting results were linear correlated,with slopes of 0.034 5 and 0.932 4.Image noise was decreased nonlinearly with the increasing mAs.When mAs increased from 60 to 140 mAs,N10 decreased from 0.25%to 0.14%,and SD reduced from 3.74 HU to 2.54 HU.When mAs reached 180 mAs or higher,N10 fluctuated between 0.1%and 0.12%,the mean SD fluctuated between 2.0 and 2.5 HU,and the downward trends obviously slowed down.When mAs increased from 60 to 200 mAs,the low contrast resolution of the image dropped from 0.53 to 0.29.The image uniformity,high contrast resolution and HU values of different substances were less affected by mAs.The image quality of 100 kV and 200 mAs scanning was close to that of 120 kV scanning,but the image quality of 80 kV scanning failed to meet the clinical requirements.Conclusion In order to reduce the radiation dose as much as possible,the mAs should be set at 200 mAs when the tube voltage is set at 100 kV for a simulated cylinder with a diameter of 20 cm.In the actual simulation scanning for pediatric radiotherapy,the scanning parameters should be fine-tuned according to the phantom results and the actual physical characteristics of children to satisfy the optimization principle for radiation protection.