1.Research on piezoelectric protein sensor array for rapid detecting HIV(1+2) antibody.
Ying WEN ; Guiqiu SHAN ; Jinhui PU ; Zhongming LIU
Journal of Biomedical Engineering 2009;26(4):883-885
To research piezoelectric immunosensor array for rapid detecting HIV(1+2), piezoelectric immunosensor array matrix was designed. HIV(1+2)C1 antigen was immobilized onto the silver electrodes of quartz-crystal microbalance, which was modified with adsorption and cross-linked method. In the clean air flow and monitoring environment, standard quality control and clinical serum sample were detected. The linear range for the measurement of HIV(1+2) was 0.01-0.2 NCU/ml. The sensitivity, specificity and accuracy of HIV(1+2) piezoelectric protein sensor array were 91.7%, 93.3% and 92.7% respectively.
Biosensing Techniques
;
instrumentation
;
methods
;
Electrodes
;
HIV
;
isolation & purification
;
HIV Antibodies
;
blood
;
Humans
;
Immunoassay
;
methods
;
Protein Array Analysis
;
instrumentation
;
methods
;
Quartz
;
Reproducibility of Results
;
Sensitivity and Specificity
2.Review on platelet-rich plasma preparation and its quality evaluation
Shaowen LI ; Zhanhong ZHU ; Nan YU ; Zhigang LU ; Yongzheng PENG ; Guiqiu SHAN
Chinese Journal of Blood Transfusion 2022;35(10):1085-1091
Platelet-rich plasma (PRP) currently has been widely used in various medical fields, such as tissue regeneration, wound healing, scar repair, skin and hair regeneration etc..PRP is rich in platelets, growth factors and other blood components, which can effectively promote tissue repair and healing. However, there is no optimal preparation method and unified standard of composition ratio for PRP, so its clinical application value has not been satisfactorily interpreted yet. In this paper, the preparation and quality standard of PRP were reviewed to provide basis for standardization of RPP in clinical application.
3.Clinical observation of autologous platelet-rich plasma eye drops in the treatment of dry eye syndrome
Yan BAI ; Jing LI ; Guiqiu SHAN ; Yeshan LIU ; Yingzhi LIU
Chinese Journal of Blood Transfusion 2024;37(9):1003-1007
【Objective】 To explore the effect of autologous platelet-rich plasma(PRP) in the treatment of dry eye syndrome. 【Methods】 A total of 64 patients with dry eye treated in the Ophthalmology Department of Jingdong Sino-American Hospital of Hebei Province from March to November 2023 were randomly selected for the study. The patients were divided into observation group and control group according to the random number table method, with 32 cases and 64 eyes in each group. The control group was treated with artificial tears of polyvinyl alcohol without preservatives, and the observation group was treated with PRP eye drops. The clinical efficacy and adverse reactions of the two groups were compared. Overall efficacy, duration of symptom resolution, ocular surface disease index (OSDI), tear film break up time (TBUT), schirmer's test(St) and corneal fluorescein staining (CFS) results of the two groups were observed and compared in 4 weeks. 【Results】 After 4 weeks of treatment, the total effective rate of observation group was 96.88%(31/32), which was significantly higher than that of control group 84.38%(27/32), with statistical significance (P<0.05). After treatment, the St, TBUT, CFS, OSDI and lacrimal river height in observation group were significantly superior to control group, with statistical significance (P<0.05). The disappearance time of dryness, visual fatigue and foreign body sensation in the observation group was shorter than that in the control group, and the difference was statistically significant (P<0.05). The incidence of adverse reactions in the observation group was 46.875%(15/32), and there was no significant difference between the observation group and the control group. 【Conclusion】 Autologous PRP is an effective and safe choice for the treatment of dry eye syndrome, which is worthy of further study and confirmation.
4.Effect of temperature on the preparation of platelet-rich plasma
Yubin XU ; Guangya LIU ; Juan YANG ; Yu ZHANG ; Mou ZHOU ; Guiqiu SHAN
Chinese Journal of Blood Transfusion 2022;35(1):78-81
【Objective】 To discuss the effect of temperature on the quality of platelet-rich plasma (PRP) prepared manually. 【Methods】 A total of 120 peripheral blood samples (60 mL/ person) were collected from healthy voluntary blood donors in the Blood Center of General Hospital of Southern Theater Command from May 10, 2010 to September 10, 2010. Each whole blood sample (60mL/ person) was randomly divided into 3 aliquots(20 mL each), totaling 360 aliquots, then divided into 9 groups (A
5.Influencing factors of clinical efficacy of autologous platelet-rich plasma in the treatment of androgenetic alopecia
Guangya LIU ; Yubing XU ; Zhanhong ZHU ; Li CHEN ; Bo ZHENG ; Mou ZHOU ; Guiqiu SHAN
Chinese Journal of Blood Transfusion 2022;35(12):1243-1247
【Objective】 To analyze the influencing factors of clinical efficacy of autologous platelet-rich plasma in the treatment of androgenetic alopecia. 【Methods】 From January, 2019 to December, 2021, 151 outpatients with androgenetic alopecia were treated in our hospital. All patients were treated with autologous PRP injection once a month and planned to received injection for 4-6 occasions. According to the hair growth before and after treatment, the treatment results were evaluated. The influencing factors in the treatment results were grouped and analyzed, including the treatment numbers (divided into 1-6 occasions), the grade of alopecia(three grades: mild, moderate and severe alopecia) and the Plt concentration in PRP[five grades(×109/L): extremely low concentration (<800), low concentration (801-1 000) and medium concentration (1 001-1 200), high concentration(1 201-1 500)and extremely high concentration(>1 501)]. 【Results】 The correlation coefficient between the number of treatments and the effective rate was pearson=0.986, P<0.001, showing a positive correlation. There was a statistical difference in the total number of treatments between groups (P<0.01). As to the severity of alopecia: The effective rates of mild and moderate alopecia patients (66.67%, 56.95%) were higher than those of severe alopecia patients (35%). The difference between groups was statistically significant (P<0.01). As to the concentration of Plt in PRP: The concentration of Plt directly affected the therapeutic effect. When the Plt count was (1 200-1 500)×109/L, the effect was optimal, reaching 68.12%, which was significantly higher than the other four groups(P<0.01). The treatment numbers, alopecia grade and Plt concentration in PRP were all related to the effectiveness of treatment (P<0.05). When the OR value of treatment numbers and Plt concentration was >1, the effective rate increased by 2.619 times and 2.033 times, respectively, as treatment numbers and Plt concentration increased. When the OR value of the grade of alopecia was 0.338 (0<0.338<1), the effective rate decreased with the increase of alopecia severity; For each grade increased, the effective rate would be compromised by 0.338. 【Conclusion】 When PRP is applied to treat AGA patients, the clinical therapeutic effect will be better in patients who received more treatments, PRP with higher Plt count, and be in the early degree of hair loss. Whether the higher the concentration of Plt in PRP, the better the therapeutic effect will be, remains to be further verified.
6.Study on the repair effect of lyophilized platelet lysate products on articular cartilage injury model of rat
Guangya LIU ; Yubing XU ; Yu ZHANG ; Zhanhong ZHU ; Mou ZHOU ; Wei ZHANG ; Guiqiu SHAN
Chinese Journal of Blood Transfusion 2022;35(4):392-395
【Objective】 To discuss the repair effect of lyophilized platelet lysate (PL) products on articular cartilage injury model of rats. 【Methods】 A total of 25 SD rats were injected with typeⅡcollagenase at the right knuckle articular cavity respectively on day 1, 3 and 5 of experiment, and the modeling conditions were observed 14 days after the last injection of collagenase. The SD rats with successful modeling were randomly divided into three groups, and were injected with lyophilized PL [Group A, 1 mL/(mouse·time)], PL [Group B, 1 mL/(mouse·time)], and normal saline[Group C, 1 mL/(mouse·time)]. The above three substances were injected with corresponding drugs on day 0, 7, 14 and 21 of experiment based on the grouping conditions, and the changes of knee joint diameters of the rats from the three groups were observed and compared. On day 14 and 28, one rat in each group was randomly killed and two knuckle articular cavities of each were taken for tissue sampling, using hematoxylin-eosin staining (HE) and immunohistochemistry. 【Results】 After 14 days of modeling by injection of type Ⅱ collagenase, the proportion of successful modeling in rats was 84% (21/25), with the knee joint diameter (mm) before and after modeling at 12.84±1.14 vs 14.11±1.17(P<0.01). On day 14, 21 and 28, groups A and B were superior to group C in the knee joint diameter and activity improvement (P<0.05), with 13.33±1.16 vs 13.37±1.08 vs 14.21±1.08, 13.10±1.09 vs 13.01±1.04 vs 14.09±1.09 and 12.38±1.08 vs 12.51±1.03 vs 14.01±1.07, respectively. Histological observation showed that group A and B were superior to group C in the production and arrangement of chondrocytes and the positive expression of type Ⅱ collagen, and there was no significant difference between group A and group B. 【Conclusion】 The lyophilized PL has similar therapeutic effect to PL in the treatment and repair of articular cartilage injury, and is worthy of clinical application.
7.Application of autologous platelet-rich plasma in the treatment of postoperative bone nonunion for long bone shaft fractures during and after operation
Yubing XU ; Guangya LIU ; Xuqiong CHEN ; Zhanhong ZHU ; Mou ZHOU ; Wei ZHANG ; Guiqiu SHAN
Chinese Journal of Blood Transfusion 2022;35(3):254-257
【Objective】 To explore the clinical effects of autologous platelet-rich plasma (PRP) in the treatment of postoperative bone nonunion for long bone shaft fractures during operation and after operation. 【Methods】 A total of 34 patients with postoperative bone nonunion for long bone shaft fracture, who were admitted and cured in the Orthopedics Department of our hospital from January 2019 to June 2020, were selected. They were randomly divided into the experimental group(n=17) and control group(n=17). Individuals in the control were treated with autologous iliac bone alone., while the experimental group were treated with autologous iliac bone graft plus autologous PRP during and after operation. After surgery, the autogenous PRP was accurately injected with ultrasound guidance every 7 days (5 mL/person, 4 occasions in total). The clinical healing time of the fracture, the grading of callus formation and the functional rehabilitation level of limbs on the affected side at different time were observed in both groups. 【Results】 All 34 patients were followed up. In the experimental group and the control group, the clinical healing time (month) of the fracture was (5.03±1.24) vs (6.91±1.41), P<0.05. The healing rate of the fracture for 6 months and 9 months was 94%(16/17)vs 59%(10/17)and 94%(16/17)vs 82%(14/17), respectively (P<0.05). The grading of callus formation within 3, 6 and 9 months was (2.11±0.69) vs (1.53±0.80), (3.06±0.90) vs (2.59±0.87) and (3.82±0.73) vs (3.35±0.86), respectively (P<0.05). The acceptance rate of functional rehabilitation of limbs on the affected side was 82.35%(14/17)vs 76.47%(13/17), P<0.05. 【Conclusion】 The application of autologous PRP in the treatment of postoperative bone nonunion for long bone shaft fractures during operation and after operation can achieve good clinical treatment.
8.Observation of therapeutic effect of autologous platelet-rich plasma on joint injury
Fang LIN ; Mou ZHOU ; Yubing XU ; ; Zhanhong ZHU ; Yu SUN ; Wendan LI ; Guiqiu SHAN
Chinese Journal of Blood Transfusion 2021;34(7):685-687
【Objective】 To study the therapeutic effect of autologous platelet-rich plasma(PRP) on joint injury. 【Methods】 Selected patients with joint injury treated in the Department of Transfusion Medicine of General Hospital of Southern Theatre Command of PLA from 2019 to 2020 were enrolled as the research objects, including 5 patients with shoulder joint injury, 34 patients with knee joint injury and 9 patients with ankle joint injury. All patients were treated with PRP injection at the injury site. The functional score and VAS score before and after treatment were compared. 【Results】 After 6 months of treatment, the CMS score and VAS of 5 patients with shoulder joint injury after treatment were (83.00±5.39) and (1.60±0.40), better than those before treatment (60.00±7.58)and (4.20±0.49)(P<0.05); The Lysholm knee score and VAS of 34 patients with knee joint injury after treatment were (80.73±2.43) and (2.07±0.24), better than those before treatment(50.30±2.96) and (4.28±0.33) (P<0.05); The AOFAS Ankle Hindfoot Scale and VAS of 9 patients with ankle joint injury after treatment were (68.44±4.59) and (2.56±0.53), better than those before treatment (42.67±4.57) and (4.89±0.63) (P<0.05). 【Conclusion】 For common joint injury sites, the clinical effect of using PRP injection is significant, which can effectively relieve pain and improve motor function, which is worthy of clinical application.
9.Comparison of effects of different anticoagulants on the release of growth factor and injection pain of platelet-rich plasma in SD rats
Li CHEN ; Guangya LIU ; Yubing XU ; Zhanhong ZHU ; Yanhui LI ; Guiqiu SHAN ; Mou ZHOU
Chinese Journal of Blood Transfusion 2023;36(8):660-664
【Objective】 To investigate the effects of different anticoagulants on platelet-rich plasma(PRP) release content of growth factor and injection pain. 【Methods】 A total of 15 voluntary blood donors were selected, with each blood donor using four kinds of anticoagulant tubes with EDTA-K
10.Preparation and preliminary evaluation of sodium alginate/agarose/carboxymethyl chitosan spray film dressing carrying platelet rich plasma for wound repair
Yubing XU ; Zhanhong ZHU ; Guangya LIU ; Li CHEN ; Zijing ZHU ; Mou ZHOU ; Guiqiu SHAN
Chinese Journal of Blood Transfusion 2023;36(2):136-140
【Objective】 To develop a spray-on membrane dressing for wound repair containing platelet rich plasma (PRP) sodium alginate (SA)/agarose(AG)/carboxymethyl chitosan (CMCS). 【Methods】 SA/AG/ CMCS were mixed in different proportions to prepare biodegradable quick setting spray (BQSS) by blending film method, and the film-forming time, moisture retention and compression resistance of the prepared BQSS were tested. Then PRP and BQSS were mixed in the proportion of 3∶7, 4∶6, 5∶5, 6∶4 and 7∶3 to prepare PRP-BQSS spray film dressings. The film-forming time, moisture retention, compressive strength, porosity and slow-release effect of growth factors of PRP-BQSS spray film dressings were studied. 【Results】 In the preparation of BQSS compound spray film solution, when SA, AG, CMCS and sterile distilled water were 0.6∶0.6∶0.6∶98.2g, the film-forming time (7.73±0.31) s, moisture retention (75. 54±3.03) % and compression resistance (791.00±68.02) g of the spray-film dressing were the best. The basic properties of PRP-BQSS spray-on film dressings and the release of growth factors show that PRP-BQSS spray-on film dressings can exist in different forms, and with the decrease of PRP concentration percentage, its film-forming time, moisturizing performance and compressive strength showed an upward trend. When the PRP content is 30%, the porosity of the dressing is the highest, about(84.34±0.90)%. The release of platelet-derived growth factor-AA(PDGF-AA), platelet factor-4(PF-4) and transforming growth factor beta (TGF-β) was in a slow upward trend, and the release of the three growth factors was higher than that of PRP group in 48 hours. 【Conclusion】 The preparation method of PRP-BQSS spray film dressing designed in this study is simple and mild, and can form a film quickly, with good biological properties and better growth factor inhibition and sustained-release effect.