1.EXAMINATING THE SPERM ANTIGEN IN SEMINAL FLUID AND SEMINAL STAIN USING ELISA METHOD
Yaqing DUAN ; Jinghua XU ; Xiaofeng WANG ; Guanshi ZHANG ; Yuxin LI
Chinese Journal of Forensic Medicine 1988;0(04):-
The sperm antigens were examined using the method of ELISA and specific monoclonal antiboby against human sperm.The results of ELISA method of 10 fresh seminal fluid samples and 15 seminal stains showed 100% positive rate. Even diluted the fresh seminal fluid to 10~6 times of seminal stains extract to 51?0~5 times,both were positive also.However,it was negtive for testing other specimens such as saliva stains,urine stains,colostrum stains,sweat stains, vaginal secretion stains and human seminal stains after vesoligation. The result certificate that using specific antibody to the sperm,the ELISA method is high sensitive and specific for the sperm antigen assay.
2.Design and mechanical properties of biodegradable polymeric stent.
Yu CHEN ; Guanshi WANG ; Chong CHEN ; Anqiang SUN ; Wentao FENG ; Wentao JIANG
Journal of Biomedical Engineering 2020;37(6):967-973
Biodegradable stents (BDSs) are the milestone in percutaneous coronary intervention(PCI). Biodegradable polymeric stents have received widespread attention due to their good biocompatibility, moderate degradation rate and degradation products without toxicity or side effects. However, due to the defects in mechanical properties of polymer materials, the clinical application of polymeric BDS has been affected. In this paper, the BDS geometric configuration design was analyzed to improve the radial strength, flexibility and reduce the shrinkage rate of biodegradable polymeric stents. And from the aspects of numerical simulation, in vitro experiment and animal experiment, the configuration design and mechanical properties of biodegradable polymeric stents were introduced in detail in order to provide further references for the development of biodegradable polymeric stents.
Absorbable Implants
;
Animals
;
Percutaneous Coronary Intervention
;
Polymers
;
Prosthesis Design
;
Stents
3.Finite element method simulating bursting process of multi-chamber flexible package infusion bag.
Huaijun YUE ; Guanshi WANG ; Wentao JIANG ; Hongbo TAN ; Wenjun LIU ; Zhongqiang ZHU ; Lin ZHU
Journal of Biomedical Engineering 2021;38(3):556-562
This study aims to overcome the shortcomings such as low efficiency, high cost and difficult to carry out multi-parameter research, which limited the optimization of infusion bag configuration and manufacture technique by experiment method. We put forward a fluid cavity based finite element method, and it could be used to simulate the stress distribution and deformation process of infusion bag under external load. In this paper, numerical models of infusion bag with different sizes was built, and the fluid-solid coupling deformation process was calculated using the fluid cavity method in software ABAQUS subject to the same boundary conditions with the burst test. The peeling strength which was obtained from the peeling adhesion test was used as failure criterion. The calculated resultant force which makes the computed peeling stress reach the peeling strength was compared with experiment data, and the stress distribution was analyzed compared with the rupture process of burst test. The results showed that considering the errors caused by the difference of weak welding and eccentric load, the flow cavity based finite element method can accurately model the stress distribution and deformation process of infusion bag. It could be useful for the optimization of multi chamber infusion bag configuration and manufacture technique, leading to cost reduction and study efficiency improvement.
Finite Element Analysis
;
Software
;
Stress, Mechanical
4.Numerical study on the effect of the geometry size of multi-chamber infusion bag on its bursting force.
Zidong FAN ; Guanshi WANG ; Huaijun YUE ; Wentao JIANG ; Zhenting DU ; Hongbo TAN ; Wenjun LIU
Journal of Biomedical Engineering 2021;38(4):716-721
This study explored the variation of bursting force of multi-chamber infusion bag with different geometry size, providing guidance for its optimal design. Models of single-chamber infusion bag with different size were established. The finite element based on fluid cavity method was adopted to calculate the fluid-solid coupling deformation process of infusion bag to obtain corresponding critical bursting force. As a result, we proposed an empirical formula predicting the critical bursting force of one chamber infusion bag with specified geometry size. Besides, a theoretical analysis, which determines the force condition of three chamber infusion bag when falling from high altitude, was conducted. The proportion of force loaded on different chamber was gained. The results indicated that critical bursting force is positively related to the length and width of the chamber, and negatively related to the height of the chamber. While the infusion bag falling, the impact force loaded on each chamber is proportional to the total liquid within it. To raise the critical bursting force of in fusion bag, a greater length and width corresponding to reduced height are recommended considering the volume of liquid needed to be filled in.