1.Dynamic contrast-enhanced MRI and diffusion weighted imaging in evaluating the early response to chemotherapy in non-small cell lung cancer
Xiaoping HE ; Zhongchang MIAO ; Guangjun BIAN ; Dehua WANG ; Shunbin JIANG ; Yongli FENG
Chinese Journal of Radiology 2016;50(10):746-751
Objective To investigate the value of dynamic contrast-enhanced(DCE)-MRI and DWI for the early assessment of curative effects in NSCLC. Methods Forty patients from September 2012 to September 2014 with NSCLC proven by pathology were examined with DCE-MRI and DWI, at one week before the first chemotherapy and one month after treatment. DCE parameters (MER, slope, WR) and ADC values of the tumors were calculated on the workstation. According to the changes of the tumor-size after treatment, all patients were divided into two groups: good response group and poor response group. Pretreatment parameters were compared between the two groups with independent-samples t test, and parameter changes before and after treatment were compared with paired-samples t Test. ROC curve of tumor response characteristic was analyzed. Pearson correlation coefficient was used to study the correlation between post-treatment parameter changes and tumor size reduction. Results Pretreatment ADC, MER and slope value were (1.15 ± 0.09) × 10-3 mm2/s, 1.13 ± 0.28, (3.76 ± 1.27)% in the good response group(15 patients), and were (1.34±0.33)×10-3mm2/s, 0.78±0.16, (2.63±0.58)%in poor response group(25 patients), respectively. There was significant difference between tumors in two groups(t=2.329, 3.152, 4.556,P=0.027, 0.032, 0.009), the lower ADC value and the higher MER/slope value was observed in the good response group. The change rates of ADC after one month treatment in the two groups were (20.43±6.40)%, (2.98±1.65)%(t=3.485,P=0.009), and slope change were (-61.80±19.21)%, (-30.80±11.16)%(t=3.280, P=0.020). Both the rising rate of ADC and decreasing rate of slope value were significant higher in good response group than the poor response group. The ROC curve was used to analyze the change rate of ADC and slope after tumors treatment, the area under the ROC curve in ADC was largest(Az=0.790), the diagnosis efficiency was highest. We found significant positive correlation between ADC, MER, slope change rate and tumor maximum diameter reduction rate after chemotherapy(r=0.637, 0.396, 0.532,P<0.05). Conclusions DCE parameters and ADC values possess important clinical value to evaluate the early effect of chemotherapy in NSCLC. ADC value is more sensitive to early lung cancer response.
2.Practice of SHDC in strengthening disciplines development of public hospitals
Peiyong ZHENG ; Rong ZHAO ; Guangjun YU ; Jiahong YANG ; Li YANG ; Ping HE ; Ning ZHENG ; Jiechun GAO
Chinese Journal of Hospital Administration 2015;(8):593-595
By means of joint research of new advanced technology project,joint development and application of appropriate health technology project,comprehensive prevention and control of chronic diseases between municipal hospitals and community clinics project and research supporting platform project,Shanghai Hospital Development Center has effectively improved the clinical science and technology innovation capability, promoted the development of medical disciplines and talents and improved the discipline influence of such hospitals.
3.Development and application of information sharing platform of municipal public hospitals
Ping HE ; Jiechun GAO ; Guangjun YU ; Rong ZHAO ; Jiahong YANG ; Peiyong ZHENG ; Li YANG ; Jianping CHEN
Chinese Journal of Hospital Administration 2015;(8):596-598
This paper introduced the design ideas and general information of Shanghai in building theHospital-Link Project.Thanks to innovative information technology and service model,it achieved real-time connectivity and clinical information sharing between the 38 municipal hospitals,which enables the general reform of such hospitals citywide.
4.CT and MRI characteristics of hepatic epithelial angiomyolipoma
Xinguan YANG ; Guangjun LIU ; Minli HE ; Yufang HU ; Qiuyun TONG ; Weijia QU
Journal of Practical Radiology 2017;33(10):1545-1548
Objective To explore the CT and MRI characteristics of hepatic epithelioid angiomyolipomas (H EA)in order to improve recognition and diagnostic accuracy of the disease.Methods The CT and MR imaging data of 8 patients with HEA proved by pathology were analyzed retrospectively.Among these patients,4 cases underwent plain and enhanced CT scans,2 plain and enhanced MRI scans and 2 both CT and MRI scans.Results In the 8 cases,7 were female.All lesions were solitary and well-defined,with maximum diameters ranging from 42 mm to 68 mm.6 leions on plain CT displayed slightly low density,of which 1 showed fat density and other 2 showed patchy cystic areas.MRI showed 4 masses with slight hypointensity on T1 WI,slight hyperintensity or hyperintensity on T2 WI,of which one demonstrated decreased signal on out-phase of T1 WI.On enhanced MR images,7 masses were significantly inhomogeneous in arterial phase,5 showed "fast wash-in and slow wash-out",2 "fast wash-in and wash-out"and 1 "slow wash-in and wash-out".6 showed"central vascular sign"in arterial phase and 2 displayed incomplete pseudocapsule in the portal venous and delayed phases.Conclusion Inhomogeneous enhancement in arterial phase,central vascular sign,fast wash-in and slow wash-out enhancement and no pseudocapsule are imaging features of HEA,which can help to improve the diagnostic accuracy.Its diagnosis still depends on histopathology and immunohistochemistry.
5.Feasibility study of guiding catheter passing through spasmodic vess els during percutaneous coronary intervention via radial artery access by the aid of PCI guiding wire and balloon
Zhuhua NI ; Lefeng WANG ; Xinchun YANG ; Hongshi WANG ; Li XU ; Weiming LI ; Kun XIA ; Yu LIU ; Jifang HE ; Yonghui CHI ; Dapeng ZHANG ; Junping DENG ; Yimin WANG ; Guangjun LIU ; Xiaoliang ZHANG ; Jianhong ZHAO ; Jiqiang ZHANG ; Jiasheng LIU ; Shuying QI
Chinese Journal of Interventional Cardiology 2016;24(6):320-325
Objective To explore the safety and feasibility of guiding catheter passing through spasmodic vessels in patients undergoing percutaneous coronary intervention (PCI) via radial artery access by the aid of PCI guiding wire and balloon .Methods The clinical data of 33 coronary artery disease (CAD) patients undergoing PCI via radial artery access with radial artery or (and) brachial artery spasm ( group A ) were retrospectively analyzed .Among all these patients , guiding catheters were delivered through the spasmodic vessels successfully by the aid of PCI guiding wires and balloons .The clinical data of other 38 CAD patients having PCI during the same period performed by other operators via radial artery or ( and ) brachial artery approach and experienced vessel spasm were anlysed as the control ( group B ) .All patients in group B received conventional anti-spasm management during PCI .All vessel spasm was identified by angiography.For patients in group A , a diameter of 0.014 inch guiding wire was chosen to pass through the spasmodic vessel segment carefully and gently .The diameter of balloon should be chosen according to the diameter of guiding catheter .A balloon diameter of 2.0 mm and 2.5 mm was corresponded to 6F and 7F guiding catheter respectively .The balloon was advanced to the tip of guiding catheter , keeping a half in catheter and a half in vessel followed by inflating the balloon with a pressure of 8 atm.The balloon was kept inflated the guiding catheter was pushed in vitro carefully and slowly until the catheter passed through the spasmodic vessel segment .Then the balloon was deflated and pulled out together with PCI guiding wire . Exchanged a diameter of 0.035 inch wire and completed the positioning of guiding catheter .After finishing the PCI, radial or ( and) brachial angiography was performed again to observe if spasm disappeared and to determine if there any contrast medium exudation .For patients in group B , routine approach was applied including administration of nitroglycerine , diltiazem or nitroprusside etc . to relieve vessel spasm. Results The location of vessel spasm was similar in group A and group B ( P=0.150 ) , and the incidence rate of spasm in brachial artery was higher than that in radial artery in both groups .The chance of guiding catheter crossing the spasmodic vessel segment was significantly higher in group A than in group B ( 100%vs.39.5%, P=0.00).In patients whose guiding catheter could pass through the spasmodic vessel segment successfully , time spent in group A was shorter than in group B ( P=0.000 ) .The patient number which time spent was less than five minutes , five to 15 minutes and more than 15 minutes was 30 and 2 ( 90.1%vs.13.3%) , 3 and 7 ( 9.9% vs.46.7%) and 0 and 6 ( 0% vs.40.0%) in group A and in group B respectively.The incidence of forearm hematoma was lower in group A than in group B without statistical difference [6.1%(2/33) vs.18.4%(7/38), P =0.113].Conclusions It is safe and feasible for passing guiding catheter through spasmodic vessels during PCI via radial artery access by the aid of PCI guiding wire and balloon .
6.Feasibility study of optical surface imaging assisted postmastectomy radiotherapy set-up
Dashuang LUO ; Zhibin LI ; Xiangyu ZHANG ; Haiping HE ; Guangjun LI ; Sen BAI
Chinese Journal of Radiological Medicine and Protection 2022;42(11):871-876
Objective:To investigate the performance of optical surface imaging (OSI) in the postmastectomy radiotherapy setup and to assess the effects of 3D printed silicone bolus on OSI detection precision.Methods:A retrospective analysis was conducted for 16 patients treated with left-sided postmastectomy radiotherapy (PMRT) in West China Hopital, Sichuan University from January to April, 2021. The setup errors of 16 patients without bolus detected using OSI (OSI no-bolus, OSI n) were obtained before error correction was conducted using cone-beam CT (CBCT). The correlation between OSI n and CBCT was analyzed, and then the diagnostic efficacy of OSI was assessed using the receiver operating characteristic (ROC) curves. The setup errors of six patients with 3D printed silicone bolus detected using OSI (OSI bolus, OSI b) were obtained through off-line image registration, and then the detection precision of OSI n and OSI b in the translational directions was compared. Results:The setup errors in the case of OSI n were highly correlated with CBCT in the translational direction ( r ≥ 0.80), but were weakly correlated in the rotation direction ( r < 0.40). In the ROC analysis, the area under the curve (AUC) in the y direction was the lowest and was in the order of AUC 5 mm ≥AUC 3 mm > 0.75 for any translational direction. The difference in the detection precision between OSI n and OSI b was not statistically significant in the x and z directions ( P > 0.05), but was statistically significant in the y direction ( Z = -2.56, P = 0.01). In the y direction, the systematic error of detection precision in the case of OSI b was 3.11 mm higher than that in the case of OSI n, and the random error of detection precision in the case of OSI b was 1.9 mm higher than that in the case of OSI n. Conclusions:OSI cannot yet substitute CBCT in the postmastectomy radiotherapy setup, but its detection error is still within the clinically acceptable range. The performance of OSI-assisted setup is expected to be further improved by mitigating the interference of factors such as bolus in the imaging path through operational training.
7.A Review of Researches on Quality Evaluation and Management of Medical Big Data
Yuxuan FENG ; Tianrui HE ; Li SHEN ; Rui ZHENG ; Guangjun YU
Journal of Medical Informatics 2024;45(8):1-7
Purpose/Significance To summarize the common dimensions of data quality evaluation,and to expound the types and characteristics of medical big data quality evaluation and management methods,so as to provide references for medical big data quality e-valuation and management.Method/Process The paper reviews domestic and foreign medical big data quality related literature,and em-phatically analyzes medical big data quality evaluation dimensions,methods and management.Result/Conclusion Data quality standards are conducive to standardized management of medical big data.A scientific and reasonable medical big data quality evaluation system and a whole-process data quality management system in line with national conditions in China should be established and improved as soon as possible to promote the development and application of medical big data in our country.
8.HFACS-based human factors analysis of radiotherapy safety incidents and exploration of incident chains
Haiping HE ; Xudong PENG ; Dashuang LUO ; Qing XIAO ; Guangjun LI ; Sen BAI
Chinese Journal of Radiological Medicine and Protection 2024;44(5):386-392
Objective:To analyze human factors in radiotherapy safety incidents and identify their correction for the purpose of mining the latent incident chains.Methods:A total of 60 radiotherapy safety incidents were included in the Radiation Oncology Incident Learning System (ROILS) for cause identification and frequency statistics using the Human Factors Analysis and Classification System (HFACS). Latent class analysis (LCA) was performed for the result to correlate the incident causes.Results:Incidents in the protocol design stage were the most common, accounting for 35%. Adverse organizational climate, inadequate supervision, and personnel factors were the primary causes of incidents at each level of the HFACS, accounting for 4.66%, 15.68%, and 16.20%, respectively. Three latent incident chains were identified through LCA, comprising two originating from organizational climate issues and one from organizational process issues, which were passed down via various human factors or " loopholes"Conclusions:HFACS assists in tracing the human factors at all levels that lead to radiotherapy safety incidents. The high-frequency causes and three latent chains of radiotherapy incidents found in this study can provide a guide for the development of targeted safety and defense measures.
9.Dosimetric effects of cardiac-respiratory motion on cardiac stereotactic body radiotherapy
Haiping HE ; Guangyu WANG ; Qing XIAO ; Dashuang LUO ; Weige WEI ; Jing LI ; Guangjun LI ; Sen BAI
Chinese Journal of Radiological Medicine and Protection 2024;44(10):835-840
Objective:To investigate the dosimetric effects of complex cardiac-respiratory motion in cardiac stereotactic body radiotherapy (CSBRT).Methods:A cardiac motion phantom was employed to simulate patient-specific cardiac-respiratory motion in 10 cases. The measured doses obtained under the phantom motion state were compared with the calculated doses in radiotherapy treatment planning for clinical patients. Moreover, 18 groups of design-based cardiac-respiratory motion were simulated. The radiation doses under the phantom motion state were measured using radiochromic films and compared with those under the resting state.Results:In the patient-specific cardiac-respiratory motion group, the gamma passing rate (GPR) under the 3%/2 mm standard between the measured and the calculated doses was 90.0% ± 7.0%. The correlation coefficient of the respiratory motion amplitude in the superior-inferior (SI) dimension with the GPR was -0.86 ( P=0.01). In the design-based cardiac-respiratory motion groups, the increase in the amplitude of cardiac-respiratory motion reduced the consistency between the dynamic dose and the static reference dose. Especially, the increase in the respiratory motion amplitude produced the most pronounced effect, reducing the width of the 90% isodose line in the respiratory motion direction, with a mean slope of -1.6. Additionally, the increase in the penumbra corresponds to a mean slope of 1.4. Conclusions:The respiratory motion amplitude serves as a primary factor influencing the dose accuracy of CBSRT. The characteristics and dosimetric effects of cardiac-respiratory motion are patient-specific, thus necessitating the assessment of cardiac-respiratory motion characteristics before CBSRT to individualize the application of motion management techniques for enhanced treatment accuracy.
10.Party for killing: the social behaviors in Cryptococcus neoformans.
Hao DING ; Guangjun HE ; Linqi WANG
Chinese Journal of Biotechnology 2017;33(9):1555-1566
Fungal pathogens represent an important group of human pathogenic microbes that lead to an unacceptably severe global burden especially due to exceptionally high mortality. For many fungal pathogens, they are widespread saprophytes and human host is not the exclusive niche for their proliferation. Their exceptional capability to survive and thrive within infected host likely stems from their sophisticated strategies in adaptation to diverse biotic and abiotic stressors from natural niches or predators. Among these 'environmental pathogens', Cryptococcus neoformans as a model organism claims the lives of more than half a million annually. Some recent studies indicate that cryptococcal survival both inside and outside of hosts can be coordinated by a combination of social behaviors. In this review, we describe and discuss the social behaviors employed by C. neoformans and address their significant impact on biofilm formation, sexual reproduction and pathogenicity.