1.Effect of Actinidia chinensis planch polysaccharide on the growth and apoptosis, and p-p38 expression in human gastric cancer SGC-7901 cells.
Wen-Ying SONG ; Guan-Hua XU ; Guang-Ji ZHANG
Chinese Journal of Integrated Traditional and Western Medicine 2014;34(3):329-333
OBJECTIVETo investigate the effect of Actinidia chinensis Planch polysaccharide (ACPS) on the growth and apoptosis of human gastric cancer SGC-7901 cells, and to explore the effect of SGC-7901 cells on p-p38 expression.
METHODSThe inhibition rates at different concentrations of ACPS on SGC-7901 cells at 24, 48, and 72 h were detected using CCK-8 method. Apoptosis ratios in SGC-7901 were determined by flow cytometry after 48-h treatment of different concentrations of ACPS. The expression of pro-caspase-9, PARP, and p-p38 in SGC-7901 cells after treated by different concentrations of ACPS was detected using Western blot. The expression of pro-caspase-9, PARP, and p-p38 was detected after SGC-7901 cells were pre-treated by p38 specific inhibitor.
RESULTSCompared with the control group, the optical density of SGC-7901 cells decreased after treated by 1, 2.5, 5, and 10 mg/mL ACPS (P < 0.05). Meanwhile, the longer the acting time, the lower the optic density (P < 0.01). IC50 was 7.43 mg/mL at 24 h; 3.88 mg/mL at 48 h, and 1.32 mg/mL at 72 h respectively. ACPS suppressed the protein expression of pro-caspase-9 (P < 0.01) and up-regulated the expression of PARP (89KD) (both P < 0.01). Further study showed that the protein expression of p-p38 was up-regulated in SGC-7901 cells treated by ACPS of different concentrations at 24 h (P < 0.05). The expression of phosphorylation p38 and the ACPS induced apoptosis of SGC-7901 cells could be inhibited after treated by specific inhibitor for 2 h.
CONCLUSIONSACPS could inhibit the growth of SGC-7901 cells and induce apoptosis. The underlying mechanism of inducing apoptosis was partially due to activating the p38MAPK path and further activating Caspase9 and PARP, finally leading to cell death.
Actinidia ; chemistry ; Apoptosis ; drug effects ; Caspase 9 ; metabolism ; Cell Line, Tumor ; Cell Proliferation ; drug effects ; Humans ; Poly (ADP-Ribose) Polymerase-1 ; Poly(ADP-ribose) Polymerases ; metabolism ; Polysaccharides ; pharmacology ; Stomach Neoplasms ; metabolism ; pathology ; p38 Mitogen-Activated Protein Kinases ; metabolism
2.New Mini Dental Implant Attachments versus O-ring Attachment after Cyclic Aging: Analysis of Retention Strength and Gap Space
Fatalla A ABDALBSEET ; SONG KE ; CAO YING-GUANG
Journal of Huazhong University of Science and Technology (Medical Sciences) 2017;37(3):419-424
Overdenture as a treatment modality for both partially and fully edentulous patients is costeffective and less expensive.The purpose of the present study was to examine the newly fabricated attachments by comparing them with conventional O-ring attachment in vitro in terms of retention force and cyclic aging resistance.A total of 150 samples were prepared and divided into five groups according to the materials used (O-ring attachment,Deflex M10 XR,Deflex Classic SR,Deflex Acrilato FD,and flexible acrylic resin).The retention force of different attachments was measured by a mini dental implant after three subsequent aging (0,63,and 126) cycles in the circumstances similar to the oral environment.The gap space between the head of the implant and the inner surface of the attachments was detected.Two-way analysis of variance (ANOVA) analysis with multiple comparisons test was applied for statistical analysis.The results showed that Deflex M10 XR had the highest retention force and the lowest gap space after cyclic aging;in addition,by comparing the relative force reduction,the lowest values were obtained in the O-ring attachment and the highest values in the flexible acrylic resin attachment.The retention force measured after cyclic aging for the Deflex M10 XR attachment was greatly improved when compared with the O-ring attachment and other types of attachment materials;in addition,the Deflex M10 XR attachment exhibited the minimum gap space between the inner surface and the mini dental implant head.In conclusion,Deflex M10 XR has the ability to withstand weathering conditions and retains its durable and retentive properties after aging when compared with other attachments.
4.Changing Characteristics of Myocardial Movement in Patients with Dilated Cardiomyopathy Identified by Three-dimensional Speckle Tracking Echocardiography
Hui LIU ; Ying LI ; Weidong REN ; Kaiwei LIU ; Guang SONG ; Wenjing BI ; Yiting ZHAO
Journal of China Medical University 2016;45(8):704-707
Objective To investigate the changing characteristics of myocardial movement in patients with dilated cardiomyopathy by three?di?mensional speckle tracking echocardiography(3D?STE). Methods The peak systolic global longitudinal train(GLS),global radial strain(GRS), global circumferential stain(GCS)and global area strain(GAS)of left ventricle were measured by 3D?STE technology in 69 patients with dilated cardiomyopathy. According to the left ventricular ejection fraction(LVEF),all patients were divided into group A(35%≤LVEF<50%)and group B (LVEF<35%). The differences of measurements were compared between two groups. The correlation between global myocardial strain in all direc?tions and left ventricular ejection fraction was analyzed. Results The GLS,GRS,GCS and GAS were significantly higher in group A than those in group B(P<0.01). The GLS,GRS,GCS and GAS were correlated with LVEF in group A(r=-0.871,0.610,-0.423,-0.797;P<0.05).The GCS,GRS and GAS were correlated with LVEF in group B(r=-0.517,0.368,-0.438;P<0.05). There was no significant correlation between GLS and LVEF in group B. Conclusion 3D?STE technology can be applied to evaluate the change of the myocardial movement. GLS is a promis?ing marker of the prognosis in patients with DCM.
5.Therapeutic effects of smecta or smectite powder on rats with paraquat toxication
Yin-Song JIANG ; Yu-Ying MA ; Zhan-Qing WANG ; Guang-Jun LI
World Journal of Emergency Medicine 2013;4(2):144-150
BACKGROUND: The plasma concentration of paraquat is closely related to the prognosis of patients with paraquat toxication, and the most common cause of death from paraquat poisoning is multiple organ failure (MOF). This study aimed to evaluate therapeutic effect of smecta on the plasma concentrations of paraquat and multi-organ injury induced by paraquat intoxication in rats. METHODS: A total of 76 healthy adult SD rats were randomly divided into group A (control group, n=6), group B (poisoned group, n=30) and group C (smecta-treated group, n=30). Rats in groups B and C were treated intragastrically with PQ at 50 mg/kg, and rats in group A was treated intragastrically with saline (1 mL). Rats in group C were given intragastrically smecta at 400 mg/kg 10 minutes after administration of PQ, while rats in other two groups were treated intragastrically with 1 mL saline at the same time. Live rats in groups B and C were sacrificed at 2, 6, 24, 48, 72 hours after administration of PQ for the determination of paraquat plasma concentrations and for HE staining of the lung, stomach and jejunum. The rats were executed at the end of trial by the same way in group A. RESULTS: The plasma concentration of paraquat (ng/mL) ranged from 440.314±49.776 to 4320.6150±413.947. Distinctive pathological changes were seen in the lung, stomach and jejunum in group B. Lung injuries deteriorated gradually, edema, leukocyte infiltration, pneumorrhagia, incrassated septa and lung consolidation were observed. Abruption of mucosa, hyperemic gastric mucosa and leukocyte infiltration were obvious in the stomach. The hemorrhage of jejunum mucosa, the abruption of villus, the gland damage with the addition of inflammatory cell infiltration were found. Compared to group B, the plasma concentration of paraquat reduced (P<0.01) and the pathological changes mentioned above were obviously alleviated in group C (P<0.05, P<0.01). CONCLUSION: Smecta reduced the plasma concentration of paraquat and alleviated pathologic injury of rats with PQ poisoning.
6.Biomechanical Evaluation of Nano-Zirconia Coatings on Ti-6Al-7Nb Implant Screws in Rabbit Tibias
I.Hamad THEKRA ; Fatalla A ABDALBSEET ; Waheed Subhi AMER ; G.M.Azzawi ZENA ; Ying-Guang CAO ; Ke SONG
Journal of Huazhong University of Science and Technology (Medical Sciences) 2018;38(3):530-537
The clinical success of dental implants can be improved by achieving optimum implant properties,such as their biomechanical and surface characteristics.Nano-structured coatings can play an important role in improving the implant surface.The purpose of the present study was to determine the most appropriate conditions for electrophoretic deposition (EPD) of nano-zirconia coatings on Ti-6Al-7Nb substrates and to evaluate the structural and biomechanical characteristics of these deposited coatings on the dental implants.EPD was used with different applied voltages and time periods to obtain a uniform layer of nano-zirconia on Ti-6Al-7Nb samples.The coated samples were weighed and the thickness of the product layer was measured.Surface analysis was performed by using optical microscopical examination,scanning electron microscope and X-ray diffraction phase analysis.For in vivo examination,48 screw-designed implants (24 uncoated and 24 nano-zirconia coated) were implanted in both tibiae of 12 white New Zealand rabbits and evaluated biomechanically after 4-and 12-week healing intervals.Results revealed that the use of different conditions for EPD affected the final coating film properties.Increasing the applied voltage and coating time period increased the deposited nano-zirconia film thickness and weight.By selecting the appropriate coating conditions,and analyzing scanning electron microscopical examination and XRD patterns,this technique could produce a thin and continuous nano-zirconia layer with a uniform thickness of the Ti-6Al-7Nb samples.Mechanically,the nano-zirconia-coated implants showed a highly statistically significant difference in removal torque values,while histologically these coated implants enhanced and promoted osseointegration after 4 and 12 weeks of healing,compared with the uncoated ones.In conclusion,EPD is an effective technique for providing a high quality nano-zirconia coating film on dental implant surfaces.Moreover,the osseointegration of these coated dental implants is improved compared with that of uncoated ones.
7.Genetical diagnosis of multiple affected tissues in a patient with McCune-Albrtght syndrome
Ji ZHOU ; Li-Hao SUN ; Bin CUI ; Huai-Dong SONG ; Xiao-Ying LI ; Guang NING ; Jian-Min LIU
Chinese Journal of Endocrinology and Metabolism 1986;0(03):-
Objective To identify the gene mutation of G protein?-subunit (Gsct) in multiple affected tissues of a patient with McCune-Albright syndrome.Methods The peripheral blood,bone tissue,lesion skin and pleura samples of the patient were collected.Genomic DNA was isolated from these samples,and PCR and direct sequencing were performed.Results The peripheral blood and bone tissue of the patient showed a mutation R201C in Gs?gene.No mutation was detected in the skin and pleura samples of the patient.Conclusion The gene diagnosis confirms that the patient has a classical R201C mutation in Gs?gene and multiple tissues are affected.The mutation occurs early in embryogenesis and clinical features can be polymorphic.
8.Detective Significance of Cerebral Electrical Admittance Plethysmogram in Newborns with Asphyxia
ke-ying, ZHOU ; jin-zhi, SONG ; jing-zhi, LI ; hui, LUO ; xue-chang, XIAO ; zhi-guang, LI ; ben-qing, WU
Journal of Applied Clinical Pediatrics 2006;0(20):-
Objective To study hemodynamics of cerebral blood flow in newborns with asphyxia.Method Bilateral cerebral electrical admittance plethysmogram(BCEAP) was used to explore characteristics of cerebral blood flow in 20 healthy newborns and 20 newborns with asphyxia respectively from first to fourth day after birth.Results Both the ratio of Hs to b-S(Hs/ b-S) and index of admittance differential loop(ADL) Ⅰ+Ⅱ decreased significantly in newborns with asphyxia compared to normal control from first to fourth day after birth(P
9.Evaluation of visual quality after phakic posterior chamber intraocular lens and iris-claw phakic intraocular lens Implantation for high myopia
Hong-liang, GUO ; Guang-ying, ZHENG ; Song-tian, WANG ; Jie, WANG ; Rui-na, WANG ; Jian-guo, ZHAO ; Li-jun, ZHAO
Chinese Journal of Experimental Ophthalmology 2011;29(5):423-426
Background High myopia can be corrected using laser therapy and intraocular lens(IOL)implantation.IOL implantation is more suitable than laser therapy for high myopia if the patients suffer from thinner cornea.Objective This clinical trail was to assess and compare the visual quality following phakic iris-claw intraocular lens (IOL) and implantable contact lens(ICL) implantation for high myopia.MethodsIris-claw phakic intraocular lens was implanted in 17 eyes of 10 patients with high myopia,and age-,refractive-matched 17 eyes of 9 patients were in implantable contact lens (ICL) implantation group.Uncorrected visual acuity,best correct visual acuity,contrast sensitivity under the 3,6,12 and 18 c/d spatial frequencies,wave-front aberrations,including RMS3,RMS4 and RMSh,were examined in 6 months after operation.Written informed consent was obtained from each patient before surgery.Results There were no significant difference in uncorrected visual acuity,best correct visual acuity between two groups(t=0.489,P>0.05;t=0.853,P>0.05).Non-glare CS under the 3 c/d,6 c/d,12 c/d and 18 c/d spatial frequencies were insignificantly different between two groups ( t = 0. 906, P > 0.05 ; t = 0. 103, P > 0. 05 ; t =0. 694 ,P>0. 05 ; t = 1. 583, P>0. 05), and the similar outcomes were found in glare CS ( t = 0. 323, P>0.05, t =0.041 ,P>0. 05, t = 0.024, P>0. 05; t = 0. 363, P>0.05) in postoperative 6 months. RMS3 and RMSh were significantly elevated in PIOL group compared with ICL group ( t = 11.40, P< 0. 05 ; t = 11.35, P < 0.05), but no evident difference was found in RMS4 between two groups( t = 0. 24,P>0. 05). Conclusion Both PIOL and ICL implantation for high myopia can achieve an equal visual acuity. But clinical outcomes of ICL implantation is much better than PIOL group. A long-term effect should be observed for the further evaluation.
10.Clinical evaluation of visual quality following implantation of posterior chamber phakic intraocular corrective lens for high myopia
Song-tian, WANG ; Guang-ying, ZHENG ; Zhi-gang, LI ; jie, WANG ; Li-jun, ZHAO ; Rui-na, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(10):926-930
Background Implantation of phakic posterior chamber intraocular corrective lens(ICL)is a new choice for correction of high myopia.Different from laser assisted in situ keratomileusis,implantation of phakic posterior chamber ICL will allow the good imaging quality because it remaines the matched relationship between cornea and lens.But its visual quality after operation is concerned by patient and ophthalmologists.ObjectiveThis study was to observe the effectiveness of implantation of posterior chamber phakic ICL on visual quality in patients with high myopia.Methods Eighty-four high myopia eyes of 42 patients accepted implantation of posterior chamber phakic ICL and follow-up of 6-month duration.The visual acuity,refractive status,wavefront,contrast sensitivity and accommodation were examined and compared before and after surgery.This clinical study complied with Declaration of Helsinki.The written informed consent was obtained from each patient before operation.Results A prospective observational trial design was used.The uncorrected visual acuity and best corrected visual acuity after operation were better than preoperative ones in all of the patients.The eye numbers of > 0.3 were increased after operation in comparison with before operation with a stable result among 1 day,1 month and 6 months after surgery (x2 =10.70,P>0.05).Spherical equivalent refraction was(-15.38 ± 1.03)D before surgery and(+0.55 ±0.06)at 1 day,(-1.22±0.09)D at 1 month and(-0.68 ± 0.06)D after 6 months,showing a significant difference among them(F=16 559.90,P<0.05).Total aberrations and higher-order aberrations were 11.00±0.25 and 0.43 ±0.05 before surgery,the wavefront aberrations were 2.21 ± 0.56 and 0.47±0.04 at 6 months after surgery with significant difference(t =1.65,P =0.10).Each spatial frequency contrast sensitivity and glare sensitivity on photopic and seotopie conditions in postoperation were higher compared with the preoperative(P<0.05).The accommodation in 1 month and 6 months after surgery was greater than that of preoperative in the patients <-16 D(preoperation:2.75 ± 1.20 ; postoperation 1 month:5.75 ± 1.44,postoperation 6 months:6.00 ± 1.52)(P< 0.05),however,in the >-16 D group,no considerably change in accommodation was seen after surgery(F=1597.70,P<0.05).No significant difference was found in accommodation between before and after surgery in >-16 D group(F=2.67,P>0.05).Conclusions Visual quality of high myopia is obviously improved after implantation of posterior chamber phakic ICL,but its long-term outcome is need to further study.