1.Relationship of Neural Protection and Expression of P-CREB and C-Jun in Hippocam pal of Neonatal Rats after Hypoxia-Ischemia Brain Damage and Reperfusion
guang-li, REN ; rui-xia, REN ; xue-fan, BAI ; ling, WANG ; mao-gui, WANG
Journal of Applied Clinical Pediatrics 1986;0(02):-
Objective To explore the survival mechanism of hippocampal ne urons after damage of hypoxia-ischemia and reperfusion of brain.Methods Seven days old SD rats(n=56) were randomly divided into hypoxia-ischemia br a in iniury(HIBD) group and sham group.The HIBD and reperfusion model was establis hed.The flowing of blood was de tected by multicolor Doppler.The p-CREB(phosphorylated c-AMP response element bi nding protein)and c-Jun were immunohistochemically evaluated in hippocampus.Thi onin staining was used to observe the apoptosis.Results The expression of p-CREB reache d the peak at 3,24 h postreperfusion in the right hippocampus of HIBD group,and then decreased to the normal level on the 7th day.In contral group the same reg ions showed basic immn-noreactivity.While c-Jun reached the peak at 6 h postreperfusion,then with a slightly decrease at 24 h;and at 48 h the other peak appeared,then with a gradual decline .On the 7th day the mumber of positive cells were still significanthy more than control group(P0.05).The sham animal showed very few apoptosis cells in the regio ns of hippocampus.Conclusions The persistent activation of CREB in the hippocampus regulates,the expression of c-Jun through the signal transductions and is involved in the course of neuron s′ survival and repair during the period of post hypoxia-ischemia reperfusion.I t is very important for the protection of the pyramidal hippocampal neurons on t he damaged side,especially for the sensitive region CA1. J Appl Clin Pediatr,2005,20(2):133-135
2.H(2)S and cellular proliferation and apoptosis.
Acta Physiologica Sinica 2007;59(2):133-140
Hydrogen sulfide (H(2)S) is among a family of endogenous molecules of gas, defined as gasotransmitters. In recent years, endogenous production of H(2)S and its physiological importance have been realized. Abnormal metabolism and functions of H(2)S contribute to or participate in the pathogenesis of many diseases. This article reviews recent discoveries on the roles of H(2)S in the regulation of cell proliferation and apoptosis. The molecular mechanisms for the cellular effects of H(2)S are also recapitulated, including changes in mitogen-activated protein kinase, cell cycle-related kinase, cell death-related gene and ion channels. A better understanding of H(2)S-regualted cell growth or death will pave way for future design of novel pharmacological and therapeutic interventions for various diseases.
Animals
;
Apoptosis
;
physiology
;
Cell Proliferation
;
Cyclin-Dependent Kinases
;
metabolism
;
Humans
;
Hydrogen Sulfide
;
metabolism
;
Mitogen-Activated Protein Kinases
;
metabolism
3.Design and analyze mathematical algorithms of intestinal absorption and metabolism of multicomponent drug.
Ling DONG ; Jia-Mei XIANG ; Yun WANG ; Rui-Guang WU ; Ming-Min TANG ; Mo-Han SUN
China Journal of Chinese Materia Medica 2014;39(23):4484-4488
Evaluation of the permeability mainly focuses on intestinal absorption in biopharmaceutics classification system (BCS). It is more complicated that the absorption and metabolism under multicomponent environment in biopharmaceutics classification system of Chinese materia medica (CMMBCS) compared with single component environment, which needs suitable mathematical models to be described. Therefore, with full consideration of existing single component mathematical algorithm combining with the characteristics of intestinal absorption and metabolism, we explored and designed a new mathematical algorithm of intestinal absorption and metabolism of multicomponent drug. Then we put forward a new coefficient, P (influence), the relative change rate of the single component's intestinal absorption and metabolism under multicomponent environment compared with single component environment, which described the influences of intestinal absorption and metabolism of the component under multicomponent environment. Moreover, P (influence) highlights the distinctive characteristics of multicomponent drug's intestinal absorption and metabolism, and lays the foundation for the construction of CMMBCS.
Algorithms
;
Drugs, Chinese Herbal
;
chemistry
;
pharmacokinetics
;
Humans
;
Intestinal Absorption
;
Intestines
;
chemistry
;
metabolism
;
Models, Theoretical
;
Solubility
4.Clinical evaluation of modified lateral approach to sciatic nerve block guided by ultrasound and nerve stimulator for foot surgery
Guang YANG ; Rui XIANG ; Wencan WANG ; Chenzhu YIN ; Jin ZHANG ; Lan ZHANG
Chinese Journal of Anesthesiology 2014;34(7):836-838
Objective To evaluate the feasibility of modified lateral approach to sciatic nerve block guided by ultrasound and nerve stimulator for foot surgery.Methods Sixty-two patients of both sexes,aged 18-60 yr,with body mass index < 30 kg/m2,of ASA physical status Ⅰ-Ⅲ,scheduled for elective foot surgery,were included in the study.Anesthesia was induced with iv propofol 2-4 mg/kg and sufentanil 0.2-0.4 μg/kg.The laryngeal mask airway was inserted and the patients were mechanically ventilated.Sevoflurane was inhaled continuously.Modified lateral approach to sciatic nerve block was performed with 0.3 % ropivacaine 30 ml under the guidance of the ultrasound combined with nerve stimulator.Rocuronium 0.6 mg/kg and propofol 1-2 mg· kg-1 · h-1 were administered after completion of sciatic nerve block.Additional sufentanil 0.10-0.15 μg/kg was intravenously injected immediately after skin incision and rocuronium 0.15 mg/kg was injected intravenously at 1 h intervals.The depth of puncture and time for puncture and success rate of puncture were recorded.Sensory block was assessed after the patients regained consciousness completely.Nerve injury,hematoma at the puncture site and infection within 72 h after surgery were recorded.Results The time for puncture was (40 ± 17) s.The depth of puncture was (5.8 ± 0.7) cm.The success rate of puncture at first attempt was 77 %.The rate of complete sensory block was 100%.The post-operative follow-up showed that no patients developed nerve injury,hematoma or infection.Conclusion Modified lateral approach to sciatic nerve block guided by ultrasound and nerve stimulator is safe and effective for foot surgery.
5.Prevention and cure of the first web contracture after hand crush injury in early stage
Yongjun RUI ; Haifeng SHI ; Quanrong ZHANG ; Zheng CHEN ; Guang CHEN ; Xiao ZHOU ; Jun WANG
Chinese Journal of Microsurgery 2010;33(2):101-103,后插四
Objective To introduce the therapeutic measure of preventing the first web contracture after hand crush injury in early stage. Methods Three types were divided according to the traumatic condition in 57 cases: closed injury, open injury and with blood vessel of thumb or fingers injury, and used different method such as closing injury postpone, opening the first web by kischner wire or mini-external fixation splint and covered by local or island flap to cure each type in primary and early stage, after 6 months, measured the width and angle of the first web. Results Forty-one cases were followed-up after 3 months - 2 years,abduction and opposition of the thumbs were fine, the average of width and angle of the first web were (5.89 ± 0.58)cm and (87.85 ± 6.03)°. Conclusion The key points of preventing the first web contracture after crush injury are opening the first web that being covered by local flap and to use splint in primary stage.
6.Posterior reversible encephalopathy syndrome:diagnosis with CT and MRI
Guang-Bin WANG ; Rui-Qin SHAN ; Bin ZHAO ; Lee C Chiu ; Hao SHI ;
Chinese Journal of Radiology 2001;0(09):-
Objective To evaluate the role of CT and MR/in the diagnosis of posterior reversible encephalopathy syndrome(PRES).Methods Eight women with PRES(6 pregnant women,1 case after chemotherapy,and 1 patient with hypertension)were enrolled in our study.All of them had MR imaging (T_1WI,T_2WI,FLAIR,DWI),and five cases underwent post-contrast T_1WI and three dimensional contrast enhanced MR angiography(3D CEMRA).Two cases also had CT scan.Results MRV in all 8 patients showed no evidence of stenosis,dilation,or thrombosis in cranial veins and sinuses.MRI demonstrated multiple lesions located in bilateral parieto-occipital lobes(8 cases),bilateral basal ganglia(2 cases),and bilateral frontal lobes(4 cases).The lesions were prominent within white matter,some of them involved gray matter(3 cases).Lesions appeared as hyperintense signals on FLAIR and T_2-weighted images, isointense or mildly hypointense signals on T_1-weighted images,normal or decreased intensity on DWI,and isointensity or hyperintensity on apparent diffusion coefficient(ADC)maps.Post-contrast T_1WI showed mild reversible enhancement and 3D CEMFdisplayed numerous reversible“grape-like”enhancements in terminal arterial branches along the middle cerebral artery(MCA),anterior cerebral artery(ACA)and posterior cerebral artery(PCA).Follow-up scan showed decreased abnormal signals.Conclusion Lesions of PRES are usually located in parieto-occipital lobes,especially in white matter,but they can also be seen in frontal lobes and basal ganglia bilaterally.Post-contrast T_1WI and 3D enhanced MRA can provide useful information in the manifestation of reversible enhancement.MRI has advantages to display lesion in PRES,
7.Clinical use of AO three-dimensionally preformed titanium mesh plates for orbital fractures
Ming, CHEN ; Guang-Rui, CHAI ; Meng, WANG ; Lu, LIU ; He-Ming, LI ; He, ZHANG
International Eye Science 2015;(1):112-116
Abstract?AlM:To evaluate the accuracy and practicability of three - dimensionally preformed Arbeitsgemeinschaft Osteosynthese AO titanium mesh plates for orbital fractures.?METHODS:Forty-seven patients with isolated blow-out orbital fractures were included in this study. Fracture locations were as follows: floor/medial wall ( n = 26, 55%), medial wall ( n = 12, 26%), and floor ( n = 9, 19%) . The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures with temporary dissection of inferior oblique muscle. A three -dimensionally preformed AO titanium mesh plate was selected according to the size of the defect previously measured on the preoperative computed tomographic scan examination and fixed at the inferior orbital rim with 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative computed tomography ( CT) scan. The practicability of clinical use of AO three - dimensionally preformed titanium mesh plates was assessed on the preoperative and postoperative clinical data.?RESULTS: Postoperative orbital CT scan showed an anatomic three- dimensional placement of the orbital mesh plates in all of the patients. All patients had a successful treatment outcome without clinical complications. 40 patients ( 87%) had a successful enophthalmos correction. 25 patients ( 86%) had a successful recovery from diplopia.?CONCLUSlON: Three- dimensionally preformed AO titanium mesh plates for orbital fracture reconstruction results in an accurate anatomic restoration of the bony orbital contour with a high rate of success to correctenophthalmos and diplopia.
8.Reconstruction of rabbit knee joint cartilage defect using tissues engineering method
Hongfeng JIANG ; Wei WEI ; Yun-Chuan XIE ; Rong-Rui LI ; Rao-Sheng ZHAI ; Ri-Guang WANG ;
Chinese Journal of Microsurgery 2000;0(03):-
Objective To estimate curative effect of reconstruction of rabbit knee joint cartilage defect with the homogeneitic tissue engineered cartilages.Methods The chondrocytes were isolated and collected from articular cartilages of eight New Zealand white rabbits.The tissue engineered cartilages after culturing chondrocytes and atelocollogen for two days.Cartilage defects were created in both keen joint of twenty-six rab- bits.Complexes of chodrocytes and atelocollagen was grafted into the defect of left knee joint at once as experi- mental group,and no implantation were served as control.General and histological examination were respec- tively performed in both group at four weeks and eight weeks after surgery.Results After implantation,the defects were filled with cartilaginous tissue in experiment group,while there were only tissue in control group. Histologically,defective areas were filled with chondrocytes in experiment group,but only fibroblast in control group.Conclusion The implantation of the tissue engineered cartilages contenting with chondrocytes and atelocollogen can effectively improve reconstruction of rabbit knee joint.
9.Evaluation of visual quality after phakic posterior chamber intraocular lens and iris-claw phakic intraocular lens Implantation for high myopia
Hong-liang, GUO ; Guang-ying, ZHENG ; Song-tian, WANG ; Jie, WANG ; Rui-na, WANG ; Jian-guo, ZHAO ; Li-jun, ZHAO
Chinese Journal of Experimental Ophthalmology 2011;29(5):423-426
Background High myopia can be corrected using laser therapy and intraocular lens(IOL)implantation.IOL implantation is more suitable than laser therapy for high myopia if the patients suffer from thinner cornea.Objective This clinical trail was to assess and compare the visual quality following phakic iris-claw intraocular lens (IOL) and implantable contact lens(ICL) implantation for high myopia.MethodsIris-claw phakic intraocular lens was implanted in 17 eyes of 10 patients with high myopia,and age-,refractive-matched 17 eyes of 9 patients were in implantable contact lens (ICL) implantation group.Uncorrected visual acuity,best correct visual acuity,contrast sensitivity under the 3,6,12 and 18 c/d spatial frequencies,wave-front aberrations,including RMS3,RMS4 and RMSh,were examined in 6 months after operation.Written informed consent was obtained from each patient before surgery.Results There were no significant difference in uncorrected visual acuity,best correct visual acuity between two groups(t=0.489,P>0.05;t=0.853,P>0.05).Non-glare CS under the 3 c/d,6 c/d,12 c/d and 18 c/d spatial frequencies were insignificantly different between two groups ( t = 0. 906, P > 0.05 ; t = 0. 103, P > 0. 05 ; t =0. 694 ,P>0. 05 ; t = 1. 583, P>0. 05), and the similar outcomes were found in glare CS ( t = 0. 323, P>0.05, t =0.041 ,P>0. 05, t = 0.024, P>0. 05; t = 0. 363, P>0.05) in postoperative 6 months. RMS3 and RMSh were significantly elevated in PIOL group compared with ICL group ( t = 11.40, P< 0. 05 ; t = 11.35, P < 0.05), but no evident difference was found in RMS4 between two groups( t = 0. 24,P>0. 05). Conclusion Both PIOL and ICL implantation for high myopia can achieve an equal visual acuity. But clinical outcomes of ICL implantation is much better than PIOL group. A long-term effect should be observed for the further evaluation.
10.Clinical evaluation of visual quality following implantation of posterior chamber phakic intraocular corrective lens for high myopia
Song-tian, WANG ; Guang-ying, ZHENG ; Zhi-gang, LI ; jie, WANG ; Li-jun, ZHAO ; Rui-na, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(10):926-930
Background Implantation of phakic posterior chamber intraocular corrective lens(ICL)is a new choice for correction of high myopia.Different from laser assisted in situ keratomileusis,implantation of phakic posterior chamber ICL will allow the good imaging quality because it remaines the matched relationship between cornea and lens.But its visual quality after operation is concerned by patient and ophthalmologists.ObjectiveThis study was to observe the effectiveness of implantation of posterior chamber phakic ICL on visual quality in patients with high myopia.Methods Eighty-four high myopia eyes of 42 patients accepted implantation of posterior chamber phakic ICL and follow-up of 6-month duration.The visual acuity,refractive status,wavefront,contrast sensitivity and accommodation were examined and compared before and after surgery.This clinical study complied with Declaration of Helsinki.The written informed consent was obtained from each patient before operation.Results A prospective observational trial design was used.The uncorrected visual acuity and best corrected visual acuity after operation were better than preoperative ones in all of the patients.The eye numbers of > 0.3 were increased after operation in comparison with before operation with a stable result among 1 day,1 month and 6 months after surgery (x2 =10.70,P>0.05).Spherical equivalent refraction was(-15.38 ± 1.03)D before surgery and(+0.55 ±0.06)at 1 day,(-1.22±0.09)D at 1 month and(-0.68 ± 0.06)D after 6 months,showing a significant difference among them(F=16 559.90,P<0.05).Total aberrations and higher-order aberrations were 11.00±0.25 and 0.43 ±0.05 before surgery,the wavefront aberrations were 2.21 ± 0.56 and 0.47±0.04 at 6 months after surgery with significant difference(t =1.65,P =0.10).Each spatial frequency contrast sensitivity and glare sensitivity on photopic and seotopie conditions in postoperation were higher compared with the preoperative(P<0.05).The accommodation in 1 month and 6 months after surgery was greater than that of preoperative in the patients <-16 D(preoperation:2.75 ± 1.20 ; postoperation 1 month:5.75 ± 1.44,postoperation 6 months:6.00 ± 1.52)(P< 0.05),however,in the >-16 D group,no considerably change in accommodation was seen after surgery(F=1597.70,P<0.05).No significant difference was found in accommodation between before and after surgery in >-16 D group(F=2.67,P>0.05).Conclusions Visual quality of high myopia is obviously improved after implantation of posterior chamber phakic ICL,but its long-term outcome is need to further study.