1.Acquiring laparoscopic skill for colorectal surgery: based on the experience of a colorectal surgeon.
Yi XIAO ; Xi-yu SUN ; Bei-zhan NIU ; Yi ZHENG ; Guang-bing XIONG ; Zhi-xuan XUAN ; Guan-nan ZHANG ; Jiao-lin ZHOU ; Bin WU ; Guo-le LIN ; Hui-zhong QIU
Chinese Journal of Surgery 2012;50(12):1063-1067
OBJECTIVELaparoscopic colorectal surgery is a skill-dependent procedure. The present study aims to analyze the learning curve of a properly trained surgeon, with basic laparoscopic techniques, to become skillful in performing laparoscopic colorectal operations.
METHODSA series of non-selective, consecutive 189 cases of laparoscopic colorectal surgery were accomplished, from December 2009 to February 2012, by one surgeon with years of skilled technique in laparoscopic cholecystectomy, rich experience in assisting laparoscopic colorectal surgery, and experience of approximately 180 procedures of gastric and colorectal surgery annually. 170 out of 189 procedures were radical operations for colorectal neoplasma, including right colectomies in 28 cases, left colectomies in 5 cases, sigmoidectomies in 28 cases, high Dixon procedures in 45 cases, low Dixon (total mesorectal excision, TME) procedures in 41 cases and Miles procedure in 23 cases. 19 other patients underwent combined procedures for multi-primary tumors or inflammatory enteritis. All these procedures were analyzed according to time span (the earlier half and later half) in respect to length of surgery, intraoperative blood loss, number of lymph nodes retrieved, intraoperative events and postoperative complications.
RESULTSFor radical right colectomy, the D2 dissection conducted in the earlier phase (n = 8) had the similar length of surgery, more blood loss and less LN retrieval, compared with the D3 dissection conducted in recent phase (n = 20). The earlier performed high Dixon procedures (n = 22) consumed longer time than the later procedures (n = 23) consumed, but with similar blood loss and LN retrieval. Low Dixon (TME) procedures showed significant differences in length of surgery and blood loss relative to time span. Recently performed simoidectomy and Miles procedures showed a trend of shorter time consumed compared with earlier performed procedures. Conversion ratio to open surgery was 1.05%. Adverse effects occurred in 8 cases of surgeries, including intestinal injury (3/189), insufficient distal margin (2/189), intraoperative bleeding (2/189) and vaginal injury (1/76). There was no operative death. Chief complications included urinary retention 5.82%, ileus 4.76%, anastomotic leak 4.24%, perineal infection 23.08% (6/26), wound dehiscence 2.65%, gastrointestinal bleeding 1.59%, peritoneal infection 1.06%. Surgery for distal rectum tended to have more complications, such as urinary retention, anastomotic leak and perineal infection. The later performed low Dixon procedures produced insignificantly fewer anastomotic leaks than those in the earlier phase.
CONCLUSIONSFor a trained surgeon with basic laparoscopic techniques, there are at least 15 - 25 cases of different procedures needed for him/her to become skilled to perform laparoscopic surgery. The learning curve should also depend on the annual number of colorectal surgeries.
Aged ; Colonic Diseases ; surgery ; Colorectal Neoplasms ; surgery ; Colorectal Surgery ; methods ; Female ; Humans ; Laparoscopy ; methods ; Learning Curve ; Male ; Middle Aged ; Postoperative Complications ; epidemiology ; Treatment Outcome
2. Homeostasis imbalance of metal ions in Alzheimer's disease
Ya-Nan LIU ; Fen-Xi NIU ; Yue LIU ; Jun GUAN ; Fang FANG
Chinese Pharmacological Bulletin 2022;38(1):9-12
Alzheimer's disease is an age-related neurodegenerative disease, and its pathogenesis has not been fully elucidated.In recent years the role of metal ions in the development and de-velopment of Alzheimer's disease has been brought into foeus.This paper reviews the homeostasis imbalance of metal ions, in- eluding the essential metal ions for human body such as Fe~ + / Fe3+ , CuV Cu2 + , Zn2 + , Mg2 + , as well as non-essential metal ions such as Al '+ and Hg"+ , involved in the pathogenesis of AI), aiming to provide research clues for anti-AD dnig targeting metal ions.
3.Progress of transcatheter aortic valve replacement in 2023
Mo-Yang WANG ; Zheng ZHOU ; Guan-Nan NIU ; Yang CHEN ; De-Jing FENG ; Xiang-Ming HU ; Wen-Ce SHI ; Yong-Jian WU
Chinese Journal of Interventional Cardiology 2024;32(1):14-19
Transcatheter aortic valve replacement(TAVR)has become one of the effective methods for treating patients with aortic valve disease.With the continuous maturity of technology,innovation of instruments and increasing experience,the indications for TAVR has been expanded.Following international trends,the number of TAVR in China has steadily increased with each passing year.In 2023,the long-term follow-up results of TAVR in low-risk AS patients further confirm the long-term benefits of TAVR.The relevant research on TAVR for patients with aortic regurgitation and patients with bicuspid aortic stenosis provide evidence support for the expansion of TAVR indications.At the same time,the development of valve devices and new technological innovations are emerging in an endless stream,and the new concept of full life cycle management is increasingly being valued.Especially in China,the development of local devices is progressing rapidly,and multiple devices have entered the clinical research stage.The clinical manifestations and research results are worth pursuing.
4.Application for a Bridge Therapy of Percutaneous Balloon Aortic Valvuloplasty in the Era of Transcatheter Aortic Valve Replacement: A Single Center Experience
Mo-Yang WANG ; Guang-Yuan SONG ; Han-Jun PEI ; Yuan WANG ; Qian ZHANG ; Guan-Nan NIU ; Zheng ZHOU ; Hao ZHANG ; Wen-Jia ZHANG ; Jian-De WANG ; Bin LV ; Yong-Jian WU ; Shu-Bin QIAO ; Yue-Jin YANG ; Run-Lin GAO
Chinese Circulation Journal 2018;33(4):336-340
Objectives: To explore the clinical experience for a bridge therapy of percutaneous balloon aortic valvuloplasty (PBAV) in treating the patients with severe aortic stenosis (AS). Methods: A total of 37 patients with severe AS who were not suitable for surgical valvular replacement received PBAV in our hospital from 2011-03 to 2017-03 were retrospectively studied. The patient's mean age was (74±12) years, their clinical and anatomical features, efficacy and safety of operation were observed and the outcomes were evaluated by follow-up study. Results: Patients presented the high surgical risk and worse cardiac function, 50% of them had bicuspid leaflet morphology with severe calcification [HU850=(856.0±658.2) mm3]. Balloon size was chosen by the intra-operative supra-annular diameters; at 7 days after operation, aortic valve orifice area (AVOA) was increased from (0.37±0.10) cm2to (0.87±1.10) cm2, the mean trans-aortic valve gradient pressure decreased form (55.1±22.9) mmHg to (44.8±17.8) mmHg, P<0.001 and LVEF elevated form(35.8±14.3)% to(41.0±12.2)%,P<0.001.There were 4 patients died in hospital,1 received permanent pacemaker and 1 developed severe aortic valve regurgitation. The patients were followed-up for (16.5±11.1)months after operation, 13/37 (35.1%) patients were in transition to surgical or transcatheter aortic valve replacement (TAVR). Conclusions: PBAV may have good early clinical efficacy in severe AS patients who were not suitable for surgical valvular replacement and TAVR; PBAV could be expected to become a bridge therapy, smaller supra-annular diameter was safe and effective for patients having bicuspid leaflet with severe calcification.
5.Clinical Features and Prognostic Risk Factors of Choroid Plexus Tumors in Children.
Wen-Jian-Long ZHOU ; Xi WANG ; Jia-Yi PENG ; Shun-Chang MA ; Dai-Nan ZHANG ; Xiu-Dong GUAN ; Jin-Fu DIAO ; Jian-Xing NIU ; Chun-De LI ; Wang JIA
Chinese Medical Journal 2018;131(24):2938-2946
Background:
Decision-making concerning the treatment of choroid plexus tumor (CPT) in pediatric patients remains a topic of considerable debate. The aim of this work was to describe clinical features and prognostic risk factors of CPT in the pediatric population and to provide theoretical opinions regarding clinical decisions for CPT.
Methods:
The data of 96 patients with CPT and younger than 14 years were retrospectively analyzed. Clinical characteristics such as pathological type of CPTs, rate and severity of hydrocephalus, treatment and outcome, and recurrence were investigated. For categorical variables, the Pearson's Chi-square test was performed. The Mann-Whitney U-test was used for comparisons between nonnormally distributed parameters. Log-rank test was used for progression-free survival (PFS).
Results:
The study included 70 choroid plexus papilloma (CPP) cases, 17 atypical choroid plexus papilloma (aCPP) cases, and 9 choroid plexus carcinoma (CPC) cases. Compared with patients with CPP or aCPP, patients with CPC had a shorter disease course (median: CPP, 4 months; aCPP, 2 months; CPC, 1 month; H: 23.5, P < 0.001), higher rate of acute hydrocephalus (CPP, 27.1%; aCPP, 52.9%; CPC, 77.8%; χ = 10.9, P < 0.05), and lower incidence of cure rate (CPP, 85.7%; aCPP, 70.5%; CPC, 33.3%; χ = 13.5, P < 0.05). The severity of hydrocephalus with tumor in the lateral or third ventricle was significantly higher than that with tumors in the fourth ventricle (severe hydrocephalus: lateral ventricle, 51.7%; third ventricle, 47.0%; fourth ventricle, 11.1%; χ = 26.0, P < 0.001). Patients with gross total surgical resection had no better PFS than those with partial resection because of the use of adjuvant therapy in the latter (χ = 4.0, P > 0.05). Patients with CPC experienced shorter time for recurrence than those with CPP or aCPP (χ = 40.1, P < 0.0001).
Conclusions
Our results indicated that CPP in the fourth ventricle could trigger serious clinical symptoms at an early stage, requiring early intervention. Adjuvant treatment might be necessary for patients with partially resected CPP, aCPP, and CPC to achieve a favorable outcome.
Child
;
Child, Preschool
;
Choroid Plexus Neoplasms
;
mortality
;
pathology
;
surgery
;
Female
;
Humans
;
Hydrocephalus
;
etiology
;
Infant
;
Male
;
Neoplasm Metastasis
;
Neoplasm Recurrence, Local
;
Prognosis
;
Risk Factors
6.Differentiation Between Amyotrophic Lateral Sclerosis and Mimics Using Quantitative Analysis of Fsciculation with Muscle Ultrasound.
Jing FAN ; Yi LI ; Jing-Wen NIU ; Nan HU ; Yu-Zhou GUAN ; Li-Ying CUI ; Ming-Sheng LIU
Chinese Medical Sciences Journal 2023;38(4):265-272
Objective To determine the diagnostic accuracy of the intensity of fasciculation evaluated by muscle ultrasound in the differential diagnosis of amyotrophic lateral sclerosis (ALS). Methods We prospectively recruited patients who had ALS and neuropathy-radiculopathy attending Peking Union Medical College Hospital from 2017 to 2020. Healthy adults from a community were recruited as healthy controls. Muscle strength was assessed using the Medical Research Council (MRC) scale. At the first visit to the hospital, patients were assessed for maximal grade of fasciculations, total fasciculation score, and fasciculation grade in 16 muscle groups of bilateral upper and lower limbs using ultrasonography. The sensitivity and specificity of maximal grade of fasciculations, total fasciculation score, and fasciculation grade for the diagnosis of ALS were assessed by receiver operating characteristic analyses. Results The percentage of limb muscles with a maximal fasciculation grade higher than grade 2 in ALS patients and neuropathy-radiculopathy patients was 84.9% and 9.8%, respectively (χ2 = 172.436, P < 0.01). Of the 16 limb muscles detected, the total fasciculation score [median (interquartile range)] was 29 (15, 41) in ALS patients and 3 (0, 8) in neuropathy-radiculopathy patients (Z = 9.642, P < 0.001). Remarkable fasciculations were seen in ALS patients whose muscles with a MRC score ranging from 2 to 4, followed by patients with MRC score 5, and then in those with MRC score 0 and 1. The sensitivity and specificity of total fasciculation score for diagnosis of ALS were 80.6% and 93.4%, respectively (cut-off value 14). In patients with ALS, for muscles with MRC score 4 and 5, the percentage of muscles with fasciculation grades ≥ 3 was 42.3% and 24.1% respectively, while in neuropathy-radiculopathy patients, the percentage for muscles with MRC score 4 and 5 was only 1.7% and 0, respectively. Conclusion A combined analysis of fasciculation intensity and MRC score of the limb muscles may be helpful for differential diagnosis of ALS.
Adult
;
Humans
;
Amyotrophic Lateral Sclerosis/diagnostic imaging*
;
Fasciculation/diagnostic imaging*
;
Radiculopathy
;
Muscle, Skeletal/diagnostic imaging*
;
Ultrasonography/methods*
7.Feasibility of single-stage stent implantation following rotational atherectomy combined with TAVR.
Mo Yang WANG ; Guang Yuan SONG ; Guan Nan NIU ; Yun Qing YE ; Yu Bin WANG ; Tong LUO ; Si Yong TENG ; Yong Jian WU
Chinese Journal of Cardiology 2021;49(1):66-70
Objective: To explore the feasibility of the single-stage stent implantation following rotational atherectomy combined with transcatheter aortic valve replacement (TAVR) in treating patients with severe aortic stenosis(AS) and severe calcified coronary artery stenosis. Methods: Three patients who received single-stage stent implantation following rotational atherectomy combined with TAVR in Fuwai hospital from April to October 2019 were included in this retrospective analysis. Clinical and anatomical features (including echocardiography and aortic CT) of the patients were collected, efficacy and safety of this operation strategy were observed and 6 months follow up results were summarized. Results: Three patients (2 females, 66-80 years old) were included. The mean Society of Thoracic Surgeons (STS) risk score was 7.8%. The mean maximum velocity of aortic valve was 4.4 m/s, the mean transvalvular pressure gradient was 53.2 mmHg (1 mmHg=0.133 kPa), mean left ventricular ejection fraction (LVEF) was 48.6%. All three patients had severe calcified coronary artery stenosis: left anterior descending artery (LAD, n=2) and left main coronary artery (LM, n=1), requiring rotary grinding. The mean SYNTAX score was 20. All the procedures were performed through transfemoral access. After aortic valve crossing, all coronary lesions were successfully treated with stent implantation following rotational atherectomy, transfemoral TAVR was then immediately performed with a self-expandable Venus-A valve. One patient underwent"valve-in-valve"implantation due to the high-implantation position of the first valve. The procedures were completed without complications in all the three patients. The immediate effect was satisfactory. Echocardiography results showed that the mean maximum velocity of aortic valve was 2.1 m/s, mean gradient was 9.3 mmHg, and mean LVEF was 59% after the procedure. There was no death and revascularization during the 6 months follow-up. Conclusion: In patients with severe calcified coronary artery and severe AS with high risk of cardiac surgery, the single-stage stent implantation following rotational atherectomy combined with TAVR is feasible and results are satisfactory in this patient cohort.
8.Left ventricular guidewire pacing during transcatheter aortic valve replacement.
Guang Yuan SONG ; Xin Min LIU ; Si Yong TENG ; Tong LUO ; Mo Yang WANG ; Yu Bin WANG ; Zheng ZHOU ; Guan Nan NIU ; Jie QIAN ; Yong Jian WU
Chinese Journal of Cardiology 2021;49(5):461-466
Objective: To investigate the safety and efficacy of left ventricular guidewire pacing during transcatheter aortic valve replacement (TAVR). Methods: This is a retrospective study. Thirteen patients, who underwent TAVR with left ventricular guidewire pacing from October 2019 to December 2019 in Fuwai Hospital, were included. Clinical data and operational procedure data of the patients were collected. Changes in blood pressure and electrocardiogram were observed during operations. Ascending aorta angiography was performed to evaluate the regurgitation of aortic valve after valve implantion. The incidence of major adverse cardiac events during hospitalization and at 3-months after discharge was recorded. Results: There were 7 male and 6 female patients in this cohort,and age was (73.8±8.3) years old. Among the 13 patients, 9 were tricuspid aortic valves, 3 were bicuspid aortic valves, and 1 was degenerated bioprosthetic surgical aortic valve. TAVR were successfully performed in all of the 13 cases using pacing through the left ventricular guidewire. During balloon dilation, the blood pressure decreased to below 60 mmHg (1 mmHg=0.133 kPa) after 180 beats/min pacing, and the valve release process was smooth and the position was stable. The results of aortography showed that there was no regurgitation in 7 cases, mild regurgitation in 5 cases and moderate regurgitation in 1 case. Three patients required temporary pacing during the procedure due to complete heart block, among whom 1 patient was implanted with permanent pacemaker during hospitalization, and the other 2 patients recovered within 24 hours after operation. In another case, there was no significant change of electrocardiogram during the operation, and complete heart block occurred 10 days after the operation, and treated with permanent pacemaker. The other 10 patients began to carry out bedside activities and rehabilitation training 24 hours after operation. There was no death, myocardial infarction, stroke and other major adverse cardiac events during hospitalization and at 3-month follow-up after discharge. Conclusion: Left ventricular guidewire pacing is a safe and effective strategy for TAVR.
Aged
;
Aged, 80 and over
;
Aortic Valve/surgery*
;
Aortic Valve Stenosis/surgery*
;
Female
;
Heart Valve Prosthesis
;
Humans
;
Male
;
Retrospective Studies
;
Risk Factors
;
Transcatheter Aortic Valve Replacement
;
Treatment Outcome
9.Single center experience of transcatheter aortic valve replacement with a simplified operative protocol.
Guang Yuan SONG ; Yue Wu ZHAO ; Guo Yong DU ; Yang CHEN ; Mo Yang WANG ; Si Yong TENG ; Tong LUO ; Zheng ZHOU ; Guan Nan NIU ; Zhen Yan ZHAO ; Zhi Nan LU ; Yong Jian WU
Chinese Journal of Cardiology 2022;50(6):563-569
Objective: To summarize the single center experience of transcatheter aortic valve replacement (TAVR) with a simplified operative protocol. Methods: Consecutive patients who underwent transfemoral TAVR (TF-TAVR) from July 2020 to December 2020 in Fuwai Hospital were retrospectively analyzed. We compared the baseline characteristic, procedure information, 30-day follow-up outcomes of the patients who underwent TF-TAVR without the simplified operative protocol (routine group) or with the simplified operative protocol (simplified protocol group). Results: 93 patients were collected, 42 patients belonging to routine group, 51 patients belonging to simplified protocol group. In simplified protocol group, there were 51 patients planned to use ultrasound-guided femoral access puncture, procedure was successful in all 51 patients (100%). There were 49 patients planned to use the radial artery as the secondary access, procedure was successful in 45 patients (92%). There were 48 patients planned to use the strategy of avoidance of urinary catheter, this strategy was achieved in 35 patients (73%). There were 12 patients planned to use the left ventricular guidewire to pace, procedure was successful in 11 patients (92%). There were no differences in baseline characteristics, major clinical endpoints and 30-day follow-up outcomes between the two groups. Meanwhile, the procedure time ((62.5±17.9)min vs. (78.3±16.7)min, P<0.001), operation room time ((133.7±25.1)min vs. (159.2±42.6)min, P<0.001), X-ray exposure time ((17.2±6.5)min vs. (20.2±7.7)min, P=0.027) were significantly shorten in simplified protocol group compared with the routine group. Conclusion: Our study results indicate that the simplified operative protocol of TF-TAVR is as effective and safe as the routine operative protocol, meanwhile using the simplified operative protocol can significantly increase the operative efficiency of TF-TAVR.
Aortic Valve
;
Aortic Valve Stenosis/surgery*
;
Femoral Artery/surgery*
;
Humans
;
Retrospective Studies
;
Risk Factors
;
Time Factors
;
Transcatheter Aortic Valve Replacement/methods*
;
Treatment Outcome
10.Initial clinical experience of left bundle branch pacing after transcatheter aortic valve implantation.
Tian Jie FENG ; Guang Yuan SONG ; Jie ZHAO ; Yang CHEN ; Guan Nan NIU ; Zheng ZHOU ; Zhen Yan ZHAO ; Mo Yang WANG ; Yong Gang SUI ; Ke Ping CHEN ; Wei HUA ; Yong Jian WU
Chinese Journal of Cardiology 2022;50(2):142-149
Objective: To investigate the efficacy and safety of left bundle branch pacing(LBBP) in patients after transcatheter aortic valve implantation (TAVI). Methods: This is a retrospective study. A total of 35 patients underwent TAVI and received pacemaker implantation from January 2018 to December 2020 in Beijing Fuwai Hospital were enrolled. Patients were divided into LBBP group (n=12) and right ventricular apex pacing (RVAP) group (n=23) according to the pacing position. The success rate of operation in LBBP group was calculated, and the occurrence of complications were observed, and the parameters of pacemaker were measured on the 3rd day and 1, 3 and 6 months after operation. The N-terminal pro-B-type natriuretic peptide (NT-proBNP), echocardiographic and ECG indexes were compared between the two groups on the 3rd day and 1, 3, and 6 months after pacemaker implantation. Result: A total of 35 patients were included, The age was (76.4±7.7) years, including 19 males (54.3%). The procedure time ((86.58±17.10)min vs. (68.74±9.18)min, P<0.001) and fluoroscopy duration ((20.08±4.44)min vs. (17.00±2.26)min, P<0.001) were significantly longer in LBBP group compared with RVAP group. The operation success rate of LBBP group was 11/12. There was no serious operation related complications such as pneumothorax, hemothorax, electrode dislocation, infection, and lower limb bleeding. The patients were followed up for 7.43 (5.21, 9.84) months. The programmed parameters of pacemaker were in the ideal range and stable during follow-up. At 3 and 6 months after operation, the left ventricular ejection fraction in LBBP group was higher than that in RVAP Group (at 3 months: (60.75±2.89)% vs. (57.35±3.33)%, P=0.004; at 6 months: (63.17±3.33)% vs. (56.17±3.97)%, P<0.001), NT-proBNP values was lower in LBBP group than that in RVAP Group (at 3 months: 822 (607, 1 150)ng/L vs. 1 052 (902, 1 536)ng/L, P=0.006; at 6 months: 440 (330,679)ng/L vs. 783 (588, 1 023)ng/L, P=0.001). At 1, 3 and 6 months after operation, the QRS duration was shorter in LBBP group than that in RVAP group (1 month: 99 (97, 107)ms vs. 126(124, 130)ms, P<0.001; 3 months: 98(96, 105)ms vs. 129(128, 133)ms, P<0.001; 6 months: 96(94, 104)ms vs. 130(128, 132)ms, P<0.001). Conclusions: For patients with permanent pacemaker indications after TAVI, LBBP is feasible, safe and reliable. It could improve the cardiac function in the short term, the long-term effect of LBBP needs to be further observed.
Aged
;
Aged, 80 and over
;
Bundle of His
;
Cardiac Pacing, Artificial/methods*
;
Electrocardiography/methods*
;
Fluoroscopy
;
Humans
;
Male
;
Retrospective Studies
;
Stroke Volume
;
Transcatheter Aortic Valve Replacement/adverse effects*
;
Treatment Outcome
;
Ventricular Function, Left