1.Grade quality standard development of Lycium barbarum fruits from Ningxia genuine producing area
Zhong-lian YU ; Xue-ping LI ; Li YANG ; Zheng-tao WANG ; Wen-jing LIU ; Rui WANG ; Yan-hong SHI
Acta Pharmaceutica Sinica 2024;59(5):1399-1407
An integrated evaluation model based on the combination of traditional trait identification and modern chemical analysis was used for the identification of key indexes of grade classification and the establishment of grade quality standard of
2.Effect of Xuanfuhua decoction on a mouse model of nonalcoholic steatohepatitis induced by high-fat, high-fructose, and high-cholesterol diet
Yijing XIN ; Yiyun CHEN ; Hailin YANG ; Yunhui ZHUO ; Dingqi ZHANG ; Fengfeng ZHOU
Journal of Clinical Hepatology 2023;39(6):1340-1350
Objective To investigate the intervention effect of Xuanfuhua decoction on mice with nonalcoholic steatohepatitis (NASH) induced by high-fat, high-fructose, and high-cholesterol diet. Methods A total of 32 male C57/BL6J mice were randomly divided into normal group, model group, Xuanfuhua decoction group, and obeticholic acid group, with 8 mice in each group. Since week 24 of modeling using high-fat, high-fructose, and high-cholesterol diet, each group was given the corresponding drug for intervention at a dose of 14.19 g/kg by gavage for the Xuanfuhua decoction group and 10 mg/kg by gavage for the obeticholic acid group and a volume of 20 mL/kg for gavage, once a day for 6 consecutive weeks. HE staining, oil red O staining, Sirius Red staining, and Masson staining were used to observe the pathological changes, lipid deposition, and collagen deposition of liver tissue; related kits were used to measure the serum levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), total cholesterol (TC), triglyceride (TG), low-density lipoprotein cholesterol (LDL-C), and glucose, as well as the content of TG and hydroxyproline (Hyp) in liver tissue; quantitative real-time PCR was used to measure the expression of genes associated with lipid metabolism, inflammation, and fibrosis in liver tissue; immunohistochemical staining was used to observe the positive expression of F4/80 and α-SMA in liver tissue. A one-way analysis of variance was used for comparison of continuous data between multiple groups, and the least significant difference t -test was used for further comparison between two groups. Results Compared with the normal group, the model group had significant increases in body weight, liver wet weight, and serum levels of AST, ALT, TC, TG, LDL-C and glucose (all P < 0.01). HE staining showed hepatocyte steatosis, a large number of fat vacuoles, hepatocyte ballooning degeneration, and inflammatory cell infiltration in liver tissue of the mice in the model group, and the model group had a significant increase in NAFLD activity score (NAS) compared with the normal group ( P < 0.01). Oil red O staining showed the deposition of a large number of red lipid droplets with different sizes in hepatocytes of the mice in the model group, and compared with the normal group, the model group had significant increases in the area percentage of oil red O staining and the content of TG in the liver ( P < 0.01). Sirius Red staining and Masson staining showed significant collagen fiber hyperplasia in the perisinusoidal area, the central vein, and the portal area in the model group, and the model group had a significant increase in the content of Hyp in liver tissue compared with the normal group ( P < 0.05). Compared with the model group, the Xuanfuhua decoction group had significant reductions in the serum levels of AST, ALT, TC, TG, LDL-C, and glucose (all P < 0.05), significant improvements in hepatic steatosis, inflammatory infiltration, lipid droplet deposition, and collagen fiber hyperplasia, and significant reductions in NAS score, area percentage of oil red O staining, and content of TG and Hyp in the liver (all P < 0.05). Compared with the normal group, the model group had significant increases in the mRNA expression levels of lipid metabolism-related genes (SREBP-1c, FASN, SCD-1, PPAR-γ, and CD36), inflammation-related genes (F4/80, TNF-α, CCL2, and CD11b), and the fibrosis-related gene α-SMA (all P < 0.05), and immunohistochemical staining showed significant increases in the positive expression of F4/80 and α-SMA ( P < 0.01). Compared with the model group, the Xuanfuhua decoction group had significant reductions in the mRNA expression levels of SREBP-1c, FASN, SCD-1, PPAR-γ, CD36, F4/80, TNF-α, CCL2, CD11b, and α-SMA in liver tissue (all P < 0.05), and immunohistochemical staining showed significant reductions in the positive expression of F4/80 and α-SMA ( P < 0.01). Conclusion Xuanfuhua decoction has a good intervention effect on mice with NASH induced by high fat, high fructose, and high-cholesterol diet and can significantly inhibit hepatic lipid deposition, inflammatory response, and liver fibrosis.
3.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
4.Establishment and evaluation of artificial intelligence image marking method for magnetically controlled capsule gastroscopy
Lijuan FENG ; Lin TIAN ; Qian ZOU ; Zhongming DAI ; Xiaojuan TIAN ; Gongli YANG ; Jingfeng DU ; Mengqi XIANG ; Yu MENG ; Long XU
Chinese Journal of Digestion 2022;42(1):14-18
Objective:To explore the marking method for magnetically controlled capsule gastroscopy (MCCG) pictures with artificial intelligence (AI), so as to improve the work efficiency of endoscopist and to reduce the blind area of AI image reading.Methods:According to the consensus of MCCG, 24 parts of stomach in 14 775 pictures of MCCG from 35 subjects in Shenzhen Zifu Medical Technology Co., Ltd received MCCG from March to August, 2020 were marked by ten gastroenterologists and one developer of MCCG with medical background, the marking shape included rectangles and polygons. Among the ten gastroenterologists, three were senior endoscopist (the total number of gastroenteroscopy operations over 80 000, chief physician or associate chief physician), four were medium seniority endoscopist (the total number of gastroenteroscopy operations between 10 000 and 80 000, associate chief physician), and three were junior endoscopist (the total number of gastroenteroscopy operations less than 10 000, attending physician). The pictures of the same subject were pre-marked by two selected senior endoscopists with blind method, and the standard of marking with most appropriate coincidence rate was determined. The qualified marked pictures were automatically learn with AI deep learning method, and the learning results were fed back. Chi square test was used for statistical analysis.Results:According to the pre-marked results, the standard of coincidence rate for rectangular marking area was set as 50.0% and that for polygon marking area was 70.0%. The first correction for qualified rate was 39.0% (5 762/14 775). A total of 9 013 pictures were corrected. After repeated training and correction for one to five times, all pictures were qualified marked. The marking qualified rate of senior endoscopist partners was higher than that of partners of different qualifications (48.7%, 1 200/2 466 vs. 19.0%, 825/4 337), and the difference was statistically significant ( χ2=659.20, P<0.001). There was no statistically significant difference in the marking qualified rate between the senior endoscopist partners and partners of senior endoscopist and capsule developer (48.7%, 1 200/2 466 vs. 49.6%, 1 496/3 019; P>0.05). Conclusions:Establishment of AI marking method for MCCG can provide technical support for AI non-blind area reading, and AI non-blind area monitoring during the operation of MCCG.
5.Naoxintong Capsule for Secondary Prevention of Ischemic Stroke: A Multicenter, Randomized, and Placebo-Controlled Trial.
Xiao-Fei YU ; Xu-Ying ZHU ; Can-Xing YUAN ; Dan-Hong WU ; Yu-Wu ZHAO ; Jia-Jun YANG ; Chang-de WANG ; Wei-Wen WU ; Xue-Yuan LIU ; Zhen-Guo LIU ; Zhi-Yu NIE ; Ben-Qiang DENG ; Huan BAO ; Long-Xuan LI ; Chun-Yan WANG ; Hong-Zhi ZHANG ; Jing-Si ZHANG ; Ji-Han HUANG ; Fan GONG ; Ming-Zhe WANG ; Yong-Mei GUO ; Yan SUN ; Ding-Fang CAI
Chinese journal of integrative medicine 2022;28(12):1063-1071
OBJECTIVE:
To examine whether the combination of Naoxintong Capsule with standard care could further reduce the recurrence of ischemic stroke without increasing the risk of severe bleeding.
METHODS:
A total of 23 Chinese medical centers participated in this trial. Adult patients with a history of ischemic stroke were randomly assigned in a 1:1 ratio using a block design to receive either Naoxintong Capsule (1.2 g orally, twice a day) or placebo in addition to standard care. The primary endpoint was recurrence of ischemic stroke within 2 years. Secondary outcomes included myocardial infarction, death due to recurrent ischemic stroke, and all-cause mortality. The safety of drugs was monitored. Results were analyzed using the intention-to-treat principle.
RESULTS:
A total of 2,200 patients were enrolled from March 2015 to March 2016, of whom 143 and 158 in the Naoxintong and placebo groups were lost to follow-up, respectively. Compared with the placebo group, the recurrence rate of ischemic stroke within 2 years was significantly lower in the Naoxintong group [6.5% vs. 9.5%, hazard ratio (HR): 0.665, 95% confidence interval (CI): 0.492-0.899, P=0.008]. The two groups showed no significant differences in the secondary outcomes and safety, including rates of severe hemorrhage, cerebral hemorrhage and subarachnoid hemorrhage (P>0.05).
CONCLUSION
The combination of Naoxintong Capsule with standard care reduced the 2-year stroke recurrence rate in patients with ischemic stroke without increasing the risk of severe hemorrhage in high-risk patients. (Trial registration No. NCT02334969).
Adult
;
Humans
;
Secondary Prevention/methods*
;
Ischemic Stroke
;
Stroke/prevention & control*
;
Cerebral Hemorrhage/complications*
;
Double-Blind Method
;
Platelet Aggregation Inhibitors
6.Oncologic outcomes of early stage cervical cancer performed operation by different laparoscopic surgical procedures: analysis of clinical data from mutiple centers
Kaijian LING ; Yanzhou WANG ; Hui ZHANG ; Xuyin ZHANG ; Junjun YANG ; Chengyan LUO ; Bin SONG ; Wenxi ZHANG ; Li DENG ; Gongli CHEN ; Yudi LI ; Qunying HU ; Yong CHEN ; Xin WANG ; Jun ZHANG ; Jingxin DING ; Tong REN ; Shan KANG ; Keqin HUA ; Yang XIANG ; Wenjun CHENG ; Zhiqing LIANG
Chinese Journal of Obstetrics and Gynecology 2020;55(9):617-623
Objective:To evaluate the oncologic outcomes of different laparoscopic radical hysterectomy.Methods:From January 2011 to December 2014, the laparoscopic operation cases of cervical cancer at stage Ⅰb1, Ⅰb2, Ⅱa1 and Ⅱa2, including the histologic subtypes of squamous-cell carcinoma, adenocarcinoma and adenosquamous carcinoma, were collected in five clinical centers. The data were divided into two groups according to the surgical procedures, that is, modified laparoscopic-vaginal radical hysterectomy (mLVRH) and total laparoscopic radical hysterectomy (TLRH). The overall survival rate (OS), disease-free survival rate (DFS) at 5 years were retrospectively analyzed in this study.Results:There were 674 cases in total, including 377 cases of mLVRH, 297 cases of TLRH. (1) The OS at 5 years: the mLVRH was 96.1% and the TLRH was 92.0%, and the mLVRH was higher than that of TLRH ( P=0.010). Stratify analysis, including stage of disease (Ⅰb1 and Ⅱa1), histologic subtypes (squamous-cell carcinoma, adenocarcinoma), lymph node metastasis, revealed that, ① Stage of disease: in stage Ⅰb1, the OS at five years of mLVRH was higher than that in TLRH group (98.6% vs 93.6%, P=0.012). In stage Ⅱa1, there was significant difference between the two groups, the OS at five years of mLVRH and TLRH were 93.6% and 77.6% ( P=0.007). ② Histologic subtypes: for the OS at five years of squamous-cell carcinoma, mLVRH and TLRH were 96.1% and 92.3%, and there was significant difference ( P=0.046); for adenocarcinoma, the OS at five years were 91.0% and 88.6%, and there was no difference between two groups ( P=0.230). ③ Lymph node metastasis: the mLVRH and TLRH with lymph node metastasis, the OS at five years were 98.6% and 96.4%; the mLVRH and TLRH without lymph node metastasis, the OS at five years were 89.3% and 80.8%. There were no significant differences between the two groups,respectively ( P=0.156, P=0.093). (2) The DFS at 5 years: there was no significant difference between mLVRH and TLRH (94.1% vs 90.9%, P=0.220). Stratify analysis for stage of disease, the mLVRH group was higher than that in the TLRH group in stage Ⅰb1 (97.0% vs 92.8%, P=0.039). However, for stage Ⅱa1, there was no significant difference between mLVRH and TLRH group (88.2% vs 75.8%, P=0.074). Conclusions:The results of this retrospective study indicated that different laparoscopy surgical procedures had diverse oncologic outcomes. The OS at 5 years of the mLVRH is superior to the TLRH. The DFS at 5 years in Ⅰb1 stage, the mLVRH is higher than the TLRH. Therefore, the modified laparoscopy is still an alternative surgery for early cervical cancer patients when following the principle of no-tumor-exposure.
7.Effects on Elbow Stability of the Terrible Triad Using Medial Collateral Ligament Repair and Ulnar Coronoid Process Fixation
Xinbin FAN ; Chao SONG ; Zhihong DING ; Liang WU ; Wenchao ZHOU ; Gang FENG ; Yue LIU ; Dece KONG ; Tieyi YANG ; Yan ZHANG
Journal of Medical Biomechanics 2020;35(5):E540-E545
Objective To investigate the effect of medial collateral ligament (MCL) repair and coronoid process fracture fixation on stability of the Terrible Triad of the elbow. Methods CT and MRI scan images of elbow joints from one healthy 28-year-old male volunteer were used to establish three elbow models. Model A: normal model. Model B: repair of coronoid process fractures, without MCL repair. Model C: repair of MCL, without repair of ulnar coronoid processes. Longitudinal loads were applied on the three models to analyze the displacement and stress distributions of the elbow joint under different working conditions and compare the stability of the elbow joint. Results The displacement and stress distributions of the three models were similar. The maximum displacement and maximum stress of the articular surface were located at the ulna pulley notch, while the minimum displacement was located at the coronoid process and its medial side. The minimum stress was located at the lower lateral side of the coronoid process. There were no statistical differences in the maximum displacement and stress among the three models (P>0.05). Conclusions When the lateral column is stable, the effect of repairing the MCL and fixing the fracture block of ulnar coronoid process is similar.
8.Efficacy and Safety of Different Dosages of Oxycodone Plus Acetaminophen for Relieving Acute Pain after Oral Operation:A Systematic Review
Jingping XIAO ; Guojun WANG ; Hengli LUO ; Ting YANG ; Gongli HU
Herald of Medicine 2016;(2):192-196
Objective To assess the efficacy and safety of different dosages of oxycodone plus acetaminophen for treating acute pain after oral surgery,in order to provide a reasonable dosage of combination in clinic. Methods Randomized controlled trials ( RCTs ) on effect of combination of oxycodone plus acetaminophen on pain relief after oral operation were searched from the following data-bases:PubMed,EMbase,MEDLINE ( Ovid) ,the Cochrane Library,CNKI,and WANFANG from the date of their establishment to January 2015. The data of RCTs meeting the inclusive criteria were extracted according to Cochrane methods by two reviewers independently,and after the quality was evaluated and cross-checked,meta-analyses were conducted using RevMan 5.2 software. Results A total of 11 studies in 10 literatures involving 1 028 patients were included and were designated to 3 different dosage groups (5 mg/325 mg,10 mg/650 mg,10 mg/1 000 mg,respectively). The results of Meta-analyses showed that pain remission rate was significantly higher in the 3 different dosages of oxycodone plus acetaminophen groups than in the placebo group (RR5 mg/325 mg=3.35,95%CI [1.74,6.45],I2=38%,P=0.000 3;RR10 mg/650 mg=6.88,95%CI [4.00,11.83],I2=0%,P<0.000 01;RR10 mg/1 000 mg=4.94,95%CI [3.23,7.56],I2=81%,P=0.005). In additional,the RR of oxycodone 10 mg/acetaminophen 650 mg and placebo groups for pain remission rate was higher than that of the other 2 dosages groups,moreover,more studies were enrolled and its low heterogeneity led to high reliability. Usage rate of remedial painkillers was significally lower in oxycodone plus acetaminophen groups than in the placebo group (RR5mg/325mg=0.71,95%CI [0.60, 0.85],P<0.000 01;RR10mg/650mg=0.50,95%CI [0.41,0.61],P<0.000 01;RR10mg/1000mg=0.77,95%CI [0.66,0.90],P=0.001) ,In addition, the RRs of usage rate in oxycodone 10 mg/acetaminophen 650 mg and placebo groups were significantly lower than the other 2 dosages groups. Incidence rates of adverse effects were similar in the 3 different dosages groups and higher than that of the placebo group. However,the adverse events were generally described as mild to moderate in severity and rarely led to drug withdrawal according to all reports in the studies ( only one event ) . Conclusion The present study showed that combination of oxycodone plus acetaminophen can provide better analgesia in acute pain after oral surgery with high safety. In addition,combination of oxycodone 10 mg plus paracetamol 650 mg may be better for acute pain relief after oral surgery.
9.Effectivity and safety of oxycodone plus acetaminophen for postoperative acute pain relief:a Meta-analysis
Jingping XIAO ; Guojun WANG ; Hengli LUO ; Ting YANG ; Gongli HU
Chongqing Medicine 2015;(30):4239-4243
Objective To assess the effectivity and safety of oxycodone plus acetaminophen for postoperative acute pain re‐lief .Methods Randomized controlled trials (RCT ) on combination of oxycodone plus acetaminophen treating postoperative pain re‐lief were searched from the following data‐bases as PubMed ,EMbase ,MEDLINE(Ovid) ,the Cochrane Library ,CNKI and WAN‐FANG from the date of their establishment to September 2014 .The data of RCT meeting the inclusive criteria were extracted ac‐cording to Cochrane methods by two reviewers independently ,and after the quality was evaluated and cross checked ,meta analyses were conducted using RevMan 5 .2 sotware .Results A total of 18 studies involving 2 213 patients were included .The results of Meta‐analyses showed that compared with placebo group or the equal dosage oxycodone alone group ,the combinations of oxycodone plus acetaminophen were more effective in postoperative pain relief (P<0 .01) .However ,there are no significant difference in the effective between the combinations of oxycodone plus acetaminophen and the higher dosage oxycodone alone group or the acetamin‐ophen alone group for postoperative pain relief (P>0 .05) .Adverse events occurred more frequently with combination therapy than placebo or acetaminophen alone group ,but were generally described as mild to moderate in severity and rarely led to withdrawal . There are no significant difference in the adverse events between the combination of oxycodone plus acetaminophen and the oxyc‐odone alone group .Conclusion The present study showed that combination of oxycodone plus acetaminophen is effective and high safe in postoperative acute pain relief .
10.Finite element analysis on three internal fixations for posterolateral tibial plateau fracture under different loads
Yan ZHANG ; Xing-bin FAN ; Xu LIANG ; Tie-yi YANG ; Wei-guang YE ; Jin SHAO ; Lu-lu GONG
Journal of Medical Biomechanics 2015;30(1):E062-E067
Objective To investigate the differences in biomechanical properties of 3 internal fixation patterns(the lateral plate and screw group, the rear plate and screw group, and the front and rear lag screw group) for treating posterolateral tibial plateau fracture under different axial loads. Methods Based on CT data of the tibial plateau, the entity model of 1/2 and 1/4 posterolateral tibial plateau fracture with 3 internal fixations were established and meshed to analyze force status of the fracture models with 3 internal fixations under different axial loads. ResultsUnder the axial load of 1 kN, for the 1/2 posterolateral tibial plateau fracture model, the displacements of the fracture fragments in the lateral plate and screw group, the rear plate and screw group, and the front and rear lag screw were 552.082, 67.964, 54.085 μm, respectively, and the stresses on the fixation device were 306.745, 231.844, 73.047 MPa, respectively. For the 1/4 posterolateral tibial plateau fracture model, the displacements in the three groups above were 416.072, 302.107, 150.639 μm, respectively, and the stresses on the fixation device were 306.673, 208.467, 73.607 MPa, respectively. Both the displacements of the fracture fragments and the stresses on the fixation device increased correspondingly under the axial load of 1.5 kN, and the trend of the data was similar to that under the axial load of 1 kN. Conclusions The results from the fracture models with 3 internal fixation patterns show that the front and rear lag screw group has a superior biomechanical stability under two different axial loads, and the similar mechanical properties can be achieved in the rear plate and screw group. Therefore, the front and rear lag screws will be preferred to treat posterolateral tibial plateau fracture with less obvious displacement in clinic.

Result Analysis
Print
Save
E-mail