1.A meibomian gland massage mechanism for upper and lower eyelids based on anti-phase rolling and enveloping movement.
Jianhuan ZHANG ; Yuan ZHOU ; Gonghao XU ; Xiong MA ; Yanping CHEN ; Wei LI
Chinese Journal of Medical Instrumentation 2014;38(4):255-273
During the course of meibomian gland dysfunction (MGD) treatment, meibomian gland massage is an effective auxiliary method. Based on an extrusion method using anti-phase massage rollers and a theory on envelope plane, a massage mechanism was proposed in this paper for the defect of the traditional mechanical assist massage structure to discharge obstruction of Meibomian gland more smoothly and to enlarge massage coverage. Meanwhile, for the case that the power of motor was significantly limited by size, an evaluation, about the input, output and loss, was carried out to initially verify the feasibility of the designed mechanism.
Eyelid Diseases
;
therapy
;
Humans
;
Massage
;
instrumentation
;
Meibomian Glands
2.A Meibomian Gland Massage Mechanism for Upper and Lower Eyelids Based on Anti-phase Rolling and Enveloping Movement
Jianhuan ZHANG ; Yuan ZHOU ; Gonghao XU ; Xiong MA ; Yanping CHEN ; Wei LI
Chinese Journal of Medical Instrumentation 2014;(4):255-258,273
During the course of meibomian gland dysfunction (MGD) treatment, meibomian gland massage is an effective auxiliary method. Based on an extrusion method using anti-phase massage rolers and a theory on envelope plane, a massage mechanism was proposed in this paper for the defect of the traditional mechanical assist massage structure to discharge obstruction of Meibomian gland more smoothly and to enlarge massage coverage. Meanwhile, for the case that the power of motor was signifi cantly limited by size, an evaluation, about the input, output and loss, was carried out to initialy verify the feasibility of the designed mechanism.
3.5.0T MR for cardiac imaging:Comparison with 3.0T MR
Lan LAN ; Naili YE ; Huijuan HU ; Wenbo SUN ; Rongqing SUN ; Gonghao LING ; Tingyi DU ; Xuan LI ; Xiaopeng SONG ; Haibo XU
Chinese Journal of Medical Imaging Technology 2024;40(5):661-665
Objective To observe the feasibility of 5.0T MR for cardiac imaging.Methods Three patients with heart diseases and 17 healthy volunteers were prospectively enrolled.Cardiac MR(CMR)cine sequence and black blood sequence imaging were performed using 5.0T and 3.0T MR scanner,respectively.The image quality and artifacts degrees were compared between 5.0T and 3.0T CMR images,and the consistency of left ventricular parameters obtained using 5.0T and 3.0T scanners was analyzed.Results No significant difference of image quality nor artifacts degrees was found between 5.0T and 3.0T CMR images(all P>0.05).The left ventricular end diastolic volume(EDV),end systolic volume(ESV),ejection fraction(EF),stroke volume(SV)and end diastolic mass(EDM)derived from cine images acquired at different fields were in a good agreement(all ICC>0.75,all P<0.001).Conclusion 5.0T MR could be used for cardiac imaging,with image quality of cine and black blood sequences comparable to that of 3.0T MR.